• 제목/요약/키워드: Abrasion Depth

검색결과 42건 처리시간 0.035초

포신 강선의 마모 깊이 측정을 위한 정전용량 방식의 MEMS 간극센서 (MEMS Capacitive Gap Sensor for Measuring Abrasion Depth of Gun Barrel Rifling)

  • 이석찬;이승섭;이창화
    • 대한기계학회논문집A
    • /
    • 제33권9호
    • /
    • pp.976-981
    • /
    • 2009
  • MEMS capacitive gap sensor is developed for measuring abrasion depth of gun barrel rifling. Measuring abrasion depth of gun barrel rifling is very important because it is related with exactness of firing and life of arms. The method using a gap sensor is not to hurt rifling. And it can measure abrasion depth through minimum shooting, because the developed gap sensor can measure from $1{\mu}m{\sim}12{\mu}m$ using Polydimethylsiloxane(PDMS) material and making a stretchable electrode on PDMS. And it's resolution is 1 ${\mu}m$ using capacitive method and MEMS technology.

Influence of Slip Angle on Abrasion Behavior of NR/BR Vulcanizates

  • Eunji Chae;Sung-Seen Choi
    • Elastomers and Composites
    • /
    • 제58권1호
    • /
    • pp.17-25
    • /
    • 2023
  • Abrasion tests of model tire tread compounds (NR and NR/BR blend compounds) were performed at different slip angles (1° and 7°) using a laboratory abrasion tester. The abrasion behavior was investigated by analyzing the worn surface and wear particles. The abrasion spacing formed on the specimen worn at the large slip angle of 7° was significantly narrower than that at the small slip angle of 1°, while the abrasion depth for the specimen worn at 7° was lower than that at 1°. The abrasion spacing and depth tended to be narrower and lower, respectively, as the BR content increased. The abrasion patterns were clearly visible on the outside of the specimen for the slip angle of 1° but not for 7°. The wear particles had a rough surface and there were numerous micro-bumps. It was found that the crosslink density affected the abrasion patterns and morphologies of the wear particles.

수종 치과용 석고의 마모저항도 및 표면조도에 관한 비교 연구 (A STUDY ON THE ABRASION RESISTANCE AND SURFACE ROUGHNESS OF THE DENTAL STONES)

  • 심혜원;이양진;조리라;정경호;김경남
    • 대한치과보철학회지
    • /
    • 제40권2호
    • /
    • pp.184-192
    • /
    • 2002
  • The purpose of this study was to investigate the abrasion resistance and surface roughness of conventional dental stones and improved dental stones and newly developed dental stones. Materials included in this study were several dental stones and newly developed dental stone; 2 type III. 6 type IV (including newly developed dental stone). 1 type V Ten specimens for each material, total ninety specimens were made. Each specimen was subjected to 50 complete cycle abrasion under constant load 0.42N at speed or 6mm per sec. The depth after abrasion test was measured for each specimen. Surface roughness before and after abrasion test was compared. The results were as follows ; 1. The resin containing die materials such as Tuff Rock and Resin Rock had superior abrasion resistance. 2. Type IV, V dental stone exhibited greater abrasion resistance than Type III dental stone. 3. The results or the surface roughness showed similar pattern with the abrasion resistance.

Scribing and cutting a sapphire wafer by laser-induced plasma-assisted ablation

  • Lee, Jong-Moo
    • 한국광학회:학술대회논문집
    • /
    • 한국광학회 2000년도 제11회 정기총회 및 00년 동계학술발표회 논문집
    • /
    • pp.224-225
    • /
    • 2000
  • Transparent and hard materials such as sapphire are used for many industrial applications as optical windows, hard materials on mechanical contact against abrasion, and substrate materials for opto-electronic semiconductor devices such as blue LED and blue LD etc. The materials should be cut along the proper shapes possible to be used for each application. In case of blue LED, the blue LED wafer should be cut to thousands of blue LED pieces at the final stage of the manufacturing process. The process of cutting the wafer is usually divided into two steps. The wafer is scribed along the proper shapes in the first step. It is inserted between transparent flexible sheets for easy handling. And then, it is broken and split in the next step. Harder materials such as diamonds are usually used to scribe the wafer, while it has a problem of low depth of scribing and abrasion of the harder material itself. The low depth of scribing can induce failure in breaking the wafer along the scribed line. It was also known that the expensive diamond tip should be replaced frequently for the abrasion. (omitted)

  • PDF

Complex analysis of rock cutting with consideration of rock-tool interaction using distinct element method (DEM)

  • Zhang, Guangzhe;Dang, Wengang;Herbst, Martin;Song, Zhengyang
    • Geomechanics and Engineering
    • /
    • 제20권5호
    • /
    • pp.421-432
    • /
    • 2020
  • Cutting of rocks is very common encountered in tunneling and mining during underground excavations. A deep understanding of rock-tool interaction can promote industrial applications significantly. In this paper, a distinct element method based approach, PFC3D, is adopted to simulate the rock cutting under different operation conditions (cutting velocity, depth of cut and rake angle) and with various tool geometries (tip angle, tip wear and tip shape). Simulation results showed that the cutting force and accumulated number of cracks increase with increasing cutting velocity, cut depth, tip angle and pick abrasion. The number of cracks and cutting force decrease with increasing negative rake angle and increase with increasing positive rake angle. The numerical approach can offer a better insight into the rock-tool interaction during the rock cutting process. The proposed numerical method can be used to assess the rock cuttability, to estimate the cutting performance, and to design the cutter head.

치은 퇴축과 치경부 마모의 임상적 변수에 관한 연구 (The Effects of Clinical Parameters on Gingival Recession and Cervical Abrasion)

  • 김은정;정진형;임성빈
    • Journal of Periodontal and Implant Science
    • /
    • 제31권1호
    • /
    • pp.243-258
    • /
    • 2001
  • Gingival recession is exposure of the root surface with apical shift in the position of gingiva. The incidence of gingival recession is 8% in children and 100% after the age of 50. Recession tends to be found in patients with healthy gingiva, but more frequentely found in patients with periodontal disease, and it often causes mucogingival defects. Buccal surface of premolar is the area not only for severe gingival recession and cervical abrasion, but also the area of numbers of buccal frenum and less keratinized gingiva. Threrfore, the goal of this study was to observe the patients with periodontitis and examine whether there are clinical relations between gingival recession and cervical abrasion of premolar and other factors related with the condition of periodontal health. Generally healthy 218 patients who had periodontitis, aged between 18 and 78, were examined for depth of periodontal poket, width of attached gingival, gingival recession, cervical abrasion, and frenum of mid-buccal surface of premolar at the Department of Periodontics in Dankook University Dental Hospital and following is the result. 1. The average gingival recession and cervical abrasion of premolar with periodontal disease was 0.76mm and 0.29mm and each has 43% and 14% of incidence. Also the width of attached gingiva of mid-buccal surface was 1.77mm. the average periodontal pocket depth is 2.0mm and 47% of frequently seen was narrow single shaped frenum, and the interdistance of the frenum was mostly over 4mm. 2. With statistical significance(P<0.05), the incidence of gingival recession increased with age and was related much more with female than male, the first premolar than the second premolar, and with narrow attached gingiva and frenum. 3. With statistical significance(p<0.05), the incidence of cervical abrasion increased with age and was related with the area of the first premolar and narrow attached gingiva, but the sexual and frenum differences were not statistically significant (p>0.05). 4. The severity of gingival recession increased with age and was more related with female than male, the first premolar than the second premolar. And the area of narrow attached gingiva and frenum showed more gingival recession and the distance of frenum was more highly related than shape, and they were statistically significant (p<0.05). 5. With statistical significance(p<0.05), the severity of cervical abrasion increase with age and was observed at the first premolar and narrow attached gingiva. But the sexual and frenum differences were not statistically significant (p>0.05).

  • PDF

고크롬 롤의 수명과 마멸특성에 관한 연구 (A Study on the Wear Characteristics and Lifetime Of High Chromium Roll)

  • 김문경;김순경;전언찬
    • 한국정밀공학회지
    • /
    • 제14권2호
    • /
    • pp.58-65
    • /
    • 1997
  • Work rolls used in cold rolling mills must have outstanding wear resistance and very little plastic defor- mation. Thus, these rolls require a higher surface hardness and harding to a greater depth. To meet these requirements, the rolls, in general, have basic chemical composition of 0.7 to 1.0% carbon and 1.0 to 5.0% Cr(chromium), plus a small amounts of special elements, and are subjected to intensive water quenching and tempering at low temperature to provide a surface hardness of over 90 shore. This test results are as follows. Deflection and fracture load of 5% Cr material are than those of 3% Cr material and show flat curve from surface to subsurface. It will be clear that 5% Cr work roll has a superior resisti- bility against wear and abrasion comparing with 3% Cr work roll. The improvement of wear and abrasion in 5% Cr work roll will be achieved by the large amount of wpheroidal carbide. In grindability and polish, 5% Cr work roll will be a little inferior comparing with 3% Cr work roll.

  • PDF

시추비트의 마모도를 고려한 라운드 트립 발생 예측 시뮬레이터 개발 (Development of Round Trip Occurrence Simulator Considering Tooth Wear of Drill Bit)

  • 이승수;김광염;신휴성
    • 터널과지하공간
    • /
    • 제23권6호
    • /
    • pp.480-492
    • /
    • 2013
  • 비화산지대에서도 적용 가능한 인공저류층 생성방식의 지열발전기술의 등장으로 막대한 비용이 소요되는 대심도 시추공사를 효율적이고 경제적으로 수행하기 위한 연구개발의 필요성이 증대되고 있다. 그러나 시추공사는 수행과정에서 수많은 불확실한 사건이 발생하여 공기와 비용을 신뢰적으로 예측하기가 매우 어렵기 때문에 계획적이고 효율적으로 공사를 관리하기가 어려운 실정이다. 특히, 비트의 마모로 인해 이산적으로 발생하는 시추장비의 라운드 트립(round trip)은 심도가 깊어질수록 소요시간이 증가하여 공사 성능에 영향을 많이 끼치는 요소로서 발생시점과 깊이를 사전에 평가하여 최적화할 수 있는 기술이 필요하다. 본 연구에서는 비트의 마모상태를 총 8단계로 구분하여 마모단계별 라운드 트립이 발생되는 깊이와 시점을 분석할 수 있는 예측 알고리즘(TOSA)을 개발하였다. 시뮬레이션을 위한 단위구간을 분할할 수 있는 방법론을 제시하였으며, 구간별 시추속도 및 비트의 마모도 예측을 위한 방법으로 Bourgoyne and Young의 모델을 활용하였다. 마지막으로 사용자 편의성을 고려하여 개발된 알고리즘을 시스템화 하였다.

SM45C재의 PVD코팅과 필름에 의한 트라이볼러지 특성 (Variations in Tribological Characteristics of SM45C by PVD Coating and Thin Films)

  • 심현보;서창민;김종형;서민수
    • 한국해양공학회지
    • /
    • 제32권6호
    • /
    • pp.502-510
    • /
    • 2018
  • In order to accumulate data to lower the friction coefficient of a press mold, tribological tests were performed before and after coating SM45C with a PVC/PO film and plasma coating (CrN, concept). The ultrasonic nanocrystal surface modification (UNSM)-treated material had a nano-size surface texture, high surface hardness, and large and deep compressive residual stress formation. Even when the load was doubled, the small amount of abrasion, small weight of the abrasion, and width and depth of the abrasion did not increase as much as those of untreated materials. A comparison of the weight change before and after the tribological test with the CrN and the concept coating material and that of the untreated material showed that the wear loss of the concept coating material and P-UNSM treated material (that is, the UNSM treated material treated with the concept coating) showed a tendency to decrease by approximately 55-75%. Concept 100N had a lower friction coefficient of about 0.6, and P-UNSM-30-100N showed almost the same curve as concept 100N and had a low coefficient of friction of about 0.6. The concept multilayer coating had a thickness of $5.32{\mu}m$. In the beginning, the coefficient of friction decreased because of the plasma coating, but it started to increase from about 250-300 s. After about 350 s, the coefficient of friction tended to approach the friction coefficient of the SM45C base metal. The SGV-280F film-attached test specimen was slightly pushed back and forth, but the SM45C base material was not exposed due to abrasion. The friction coefficient was 0.22, which was the lowest, and the tribological property was the best in this study.

생불활성 질화물 이온도금된 티타늄 임프란트의 표면특성 및 생체적합성 (Surface characteristics and biocompatibility of bioinert nitrides ion plated titanium implant)

  • 장갑성;김흥중;박주철;김병옥;한경윤
    • Journal of Periodontal and Implant Science
    • /
    • 제29권1호
    • /
    • pp.209-231
    • /
    • 1999
  • Even though titanium(Ti) and its alloys are the most used dental implant materials, there are some problems that Ti wears easily and interferes normal osteogenesis due to the metal ions. Ti coated with bioactive ceramics such as hydroxyapatite has also such problems as the exfoliation or resorption of the coated layer, Recent studies on implant materials have been proceeding to improve physical properties of the implant substrate and biocompatibility of the implant surfaces. The purpose of the present study was to examine the physical property and bone tissue compatibility of bioinert nitrides ion plated Ti, Button type specimens(14mm in diameter, 2.32rrun in height) for the abrasion test and cytotoxicity test and thread type implants(3.75mm in diameter, 6mm in length) for the animal experiments were made from Ti(grade 2) and 316LVM stainless steel. Ti specimens were ion plated with TiN, ZrN by the low temperature arc vapor deposition, and the depth profile of the TiN/Ti, ZrN/Ti ion plated surface was examined by Auger Electron Spectroscopy. Three kind of button type specimens .of TiN/Ti, ZrN/Ti and Ti were used for abrasion test, and HEPAlClC7 cells and CCD cells were cultivated for 4 days with the specimens for cytotoxicity test. Thread type implants of TiN/Ti, ZrN/Ti, Ti, 316LVM were implanted on the femur of 6 adult dogs weighing 10kg-13kg. Two dogs were sacrified for histological examination after 45 days and 90 days, and four dogs were sacrified for the removal torque test of the implant') after 90 days. The removal torque force was measured by Autograph (Shimadzu Co., AGS-1000D series, Japan). Abrasion resistance of TiN/Ti was the highest, and that of ZrN/Ti and Ti were followed. The bioinert nitride ion plated Ti had much better abrasion resistance, compared with Ti, In the cytotoxicity test, the number of both cells were increased in all specimens, and there were no significant difference in cytotoxic reaction among all groups (p>0.1), In histological examination, 316LVM showed the soft tissue engagement in interface between the implant and bone, but the other materials after 45 days noted immature new bone formation in the medullary portion along the implant surface, and those after 90 days showed implant support by new bone formation in both the cortical and the medullary portion, The removal torque force of Tilv/Ti showed significantly higher than that of Ti(p(O,05). The difference in removal torque force between TiN/Ti and ZrN/Ti was not significant(p>0.05), and that of 316LVM was lowest among all groups(p<0.05). These results suggest that bioinert nitrides ion plated Ti can resolve the existing problems of Ti and bioactive ceramics, and it may be clinically applicable to human.

  • PDF