• 제목/요약/키워드: Ablating

검색결과 14건 처리시간 0.022초

ABLATING AND CHARRING OF TWO DIMENSIONAL HEAT SHIELD MATERIALS

  • Shabani Mohammad Reza;Rahimian Mohammad Hassan
    • 한국전산유체공학회지
    • /
    • 제10권1호
    • /
    • pp.16-23
    • /
    • 2005
  • The objective of this research is to estimate two dimensional ablating and charring of heat shield materials in severe aero-thermal heat transfer. This estimation requires an accurate and rapid technique for its serious heat transfer with a moving boundary. Aerodynamic heating is obtained by an explicit relation which is a function of Mach number and air condition, while a fully implicit method is used for heat transfer calculations. Moving boundary is captured by FLIAR method which is a subgroup of VOF. Thickness of ablating and charring of heat shield, temperature of the moving surface and rate of radiation heat are calculated and compared with references. The results are in good agreement with other calculations.

열보호재료의 열 및 물질전달 현상에 관한 수치해석적 연구 (A Numerical Study of Heat and Mass Transfer Phenomena for Thermal Protection Material)

  • 김정훈;권창오;서정일;배철호;송동주
    • 대한기계학회논문집B
    • /
    • 제23권9호
    • /
    • pp.1201-1212
    • /
    • 1999
  • A numerical analysis is performed to predict the thermal response and ablation rate for charring or non-charring material which is designed to be used as thermal protection system (TPS). The numerical program composed of in-depth energy balance equation and the aerotherm chemical equilibrium (ACE) program. The ACE program calculates various thermochemical state from ablation products. The developed numerical program is verified by comparing the reported results from literature. The sensitivity tests for input parameters are performed. The thermal behavior of ablating material is mainly affected by density of ablating material, convective heat transfer coefficient and recovery enthalpy of flow field.

Laser Assisted Lift-Off Process as a Organic Patterning Methodology for Organic Thin-Film Transistors Fabrication

  • Kim, Sung-Jin;Ahn, Taek;Suh, Min-Chul;Mo, Yeon-Gon;Chung, Ho-Kyoon;Bae, Jin-Hyuk;Lee, Sin-Doo
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2006년도 6th International Meeting on Information Display
    • /
    • pp.1154-1157
    • /
    • 2006
  • Organic thin-film transistors (OTFTs) based on a semiconducting polymer have been fabricated using an organic patterning methodology. Laser assisted lift-off (LALO) technique, ablating selectively the hydrophobic layer by an excimer laser, was used for producing a semiconducting polymer channel in the OTFT with high resolution. The selective wettability of a semiconducting polymer, poly (9-9-dioctylfluorene-co-bithiophene) (F8T2), dissolved in a polar solvent was found to define precisely the pattering resolution of the active channel. It is demonstrated that in the F8T2 TFTs fabricated using the LALO technique and is applicable for the larger area display.

  • PDF

KrF 엑시머 레이저에 의한 ITO 박막의 어블레이션과 표면특성관찰 (The ablation of ITO thin films by KrF Eximer laser and its characteristics)

  • Lee, Kyoung-Cheol;Lee, Cheon
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2000년도 추계학술대회 논문집
    • /
    • pp.511-514
    • /
    • 2000
  • This work aimed to develop ITO (Indium Tin Oxide) thin films ablation with a KrF Eximer laser required for the application in flat panel display, especially patterning into small geometry on a large substrate area. The threshold fluence for ablating ITO on glass substrate is about 0.1 J/cm$^2$. And its value is much smaller than using third harmonic Nd:YAG laser. Through the optical microscope measurement the surface color of the damaged ITO is changed into dark brown and irradiated spot is completely isolated form the undamaged surroundings by laser light. The XPS analysis showed that the relative surface concentration of Sn and In were essentially unchanged (In :Sn=5:1) after irradiating Eximer laser. Using aluminium mask made by second harmonic Nd:YAG laser the ITO patterning is carried out.

  • PDF

3차원 레이저 스캐너를 이용한 인쇄롤 가공에 관한 연구 (Study on Printing Roll Manufacturing by using 3 Dimensional Laser Scanner)

  • 강희신;노지환;손현기
    • 한국레이저가공학회지
    • /
    • 제16권4호
    • /
    • pp.17-23
    • /
    • 2013
  • The research for the development of roll-to-roll printing process is actively underway on behalf of the existing semiconductor process. The roll-to-roll printing system can make the electronic devices to low-cost mass production. This study is performed for developing the manufacturing technology of the printing roll used in the printing process of electronic devices. The indirect laser engraving technology is used to create printable roll and the printable roll is made out of the chrome coated roll after coating copper and polymer on the surface of steel roll, ablating the polymer on the surface of roll and etching the roll. The 3 dimensional laser scanner and roll rotating systems are constructed and the system control program is developed. We have used the fiber laser of 100 W grade, the 3 dimensional laser scanner and the 3 axes moving stage system with a rotating axis. We have found the optimal conditions by performing the laser patterning experiments and can make the minimum line width of $24{\mu}m$ by using the developed 3 dimensional laser scanner system.

  • PDF

Efficiency of Gas-Phase Ion Formation in Matrix-Assisted Laser Desorption Ionization with 2,5-Dihydroxybenzoic Acid as Matrix

  • Park, Kyung Man;Ahn, Sung Hee;Bae, Yong Jin;Kim, Myung Soo
    • Bulletin of the Korean Chemical Society
    • /
    • 제34권3호
    • /
    • pp.907-911
    • /
    • 2013
  • Numbers of matrix- and analyte-derived ions and their sum in matrix-assisted laser desorption ionization (MALDI) of a peptide were measured using 2,5-dihydroxybenzoic acid (DHB) as matrix. As for MALDI with ${\alpha}$-cyano-4-hydroxy cinnamic acid as matrix, the sum was independent of the peptide concentration in the solid sample, or was the same as that of pure DHB. This suggested that the matrix ion was the primary ion and that the peptide ion was generated by matrix-to-peptide proton transfer. Experimental ionization efficiencies of $10^{-5}-10^{-4}$ for peptides and $10^{-8}-10^{-7}$ for matrices are far smaller than $10^{-3}-10^{-1}$ for peptides and $10^{-5}-10^{-3}$ for matrices speculated by Hillenkamp and Karas. Number of gas-phase ions generated by MALDI was unaffected by laser wavelength or pulse energy. This suggests that the main role of photo-absorption in MALDI is not in generating ions via a multi-photon process but in ablating materials in a solid sample to the gas phase.

ITO Thin Film Ablation Using KrF Excimer Laser and its Characteristics

  • Lee, Kyoung-Chel;Lee, Cheon;Le, Yong-Feng
    • Transactions on Electrical and Electronic Materials
    • /
    • 제1권4호
    • /
    • pp.20-24
    • /
    • 2000
  • This study aimed to develop ITO(Indium Tim Oxide) tin films ablation with a pulsed type KrF excimer laser required for the electrode patterning application in flat panel display into small geometry on a large substrate are. The threshold fluence for ablating ITO on glass substrate is about 0.1 J/㎠. And its value is much smaller than that using 3 .sup rd/ harmonic Nd:YAG laser. Through the optical microscope measurement the surface color of the ablated ITO is changed into dark brown due to increase of surface roughness and transformation of chemical composition by the laser light. The laser-irradiated regions were all found to be electrically isolating from the original surroundings. The XPS analysis showed that the relative surface concentration of Sn and In was essentially unchanged (In:Sn=5:1)after irradiating the KrF excimer laser. Using Al foil made by 2$\^$nd/ harmonic Na:YAG laser, the various ITO patterning is carried out.

  • PDF

Treatment of Atrial Fibrillation in Elderly Patients with the Cox Maze Procedure Concurrently with Other Cardiac Operations

  • Kuh, Ja Hong;Song, Joon Young;Kim, Tae Youn;Kim, Jong Hun;Choi, Jong Bum
    • Journal of Chest Surgery
    • /
    • 제50권3호
    • /
    • pp.171-176
    • /
    • 2017
  • Background: In elderly patients who have atrial fibrillation (AF), surgical ablation of the arrhythmia during cardiac surgery may be challenging. Despite the reported advantages of ablating AF with the Cox maze procedure (CMP), the addition of the CMP may complicate other cardiac operations. We evaluated the effect of the CMP in elderly patients concurrent with other cardiac operations. Methods: From October 2007 to December 2015, we enrolled 27 patients aged >70 years who had AF and who underwent the CMP concurrently with other cardiac operations. The mean preoperative additive European System for Cardiac Operative Risk Evaluation score was $8{\pm}11$ (high risk). Results: Only 1 hospital death occurred (4%). The Kaplan-Meier method showed a high 5-year cumulative survival rate (92%). At mean follow‐up of 51 months, 23 patients (89%) had sinus rhythm conversion. The postoperative left atrial dimensions did not significantly differ between the 8 patients who had reduction plasty for giant left atrium ($53.4{\pm}7.5cm$) and the 19 patients who did not have reduction plasty ($48.7{\pm}5.7cm$). Conclusion: In patients aged >70 years, concurrent CMP may be associated with a high rate of sinus rhythm conversion without increased surgical risk, despite the added complexity of the main cardiac procedure.

레이저 이온화 이온트랩 질량분석법을 이용한 금속 및 세라믹 시료의 원소분석에 관한 연구 (Study on elemental analysis of metal and ceramic samples by using laser ablation ion trap mass spectrometry(LAITMS))

  • 송규석;박현국;차형기;이상천
    • 분석과학
    • /
    • 제15권1호
    • /
    • pp.7-14
    • /
    • 2002
  • 본 연구에서는 레이저 애블레이션 이온 트랩 질량분석법을 이용하여 금속 및 세라믹 시료들에 대한 원소분석을 수행하였고, 이때 이온화 장치로는 XeCI 엑시머 레이저를 사용하였고 검출장치로서 이온트랩 질량 분석기를 사용하였다. 시료는 트랩의 바깥에 장착하여 시료의 교환이 매우 쉽도록 하였고 고체시료의 분석에 있어서 매우 효과적임을 밝혔다. 헬륨기체의 압력이나 이온저장시간, 초기질량제한 RF 전압 등에 대한 기초 실험을 통하여 실험의 최적 조건을 구하였고 (헬륨 기체압력 $1{\times}10^{-4}$ Torr 이온 저장시간 100 ms 초기 질량 제한전압 $1150V_{p-p}$), 이 결과를 토대로 금속시료(구리, 몰리브데늄)와 세라믹 시료(알루미나 세라믹, 지르코니아 세라믹) 들에 대한 원소분석을 수행하였다.