• Title/Summary/Keyword: Abel Inversion

Search Result 16, Processing Time 0.031 seconds

Experimental Study on Combustion Instability Mechanism in a Lean Premixed Model Gas Turbine Combustor using OH Chemiluminescence Images (희박 예혼합 모형 가스터빈 연소기의 OH 자발광을 이용한 연소불안정성에 대한 실험적 연구)

  • Lee Jae Ho;Lee Jong Ho;Chang Young June;Jeon Chung Hwan
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • v.y2005m4
    • /
    • pp.259-264
    • /
    • 2005
  • Measurements of heat release are very important for controling combustion instabilities, which are closely connected with combustion instabilities. $OH^{\ast}$ images were acquired through a ICCD in this study, which were in use as indicating index of the reacting region, global and local heat release rate in the lean premixed combustion. The objectives of this study are to see the effect of equivalence ratio on global heat release rate and local Rayleigh index distribution. The local Rayleigh index distribution was acquired by information from central section of flame. This information was from the line-of-sight images which were inverted by the Abel de-convolution. In each condition, the mean value of heat release increased exponentially with equivalence for a periodic time. Local Rayleigh index distribution cleary showed the region of amplifying or damping the combustion instability as the equivalence ratio increased. This could provide an insight on the region of combustion instability and the structure of flames on the equivalence ratio.

  • PDF

Experimental Study on Heat Release in a Lean Premixed Dump Combustor Using OH Chemiluminescence Images (희박 예혼합 덤프 연소기에서 OH 자발광을 이용한 열 방출에 관한 실험적 연구)

  • Moon, Gun-Feel;Lee, Jong-Ho;Jeon, Chung-Hwan;Chang, Young-June
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.28 no.11
    • /
    • pp.1368-1375
    • /
    • 2004
  • Measurements of OH chemiluminescence in an atmospheric pressure, laboratory-scale dump combustor at equivalence ratios ranging from 0.63 to 0.89 were reported. The signal from the first electronically excited state of OH to ground state was detected through a band-pass filter with an ICCD. The objectives of this study are two: One is to see the effects of equivalence ratio on global heat release rate and local Rayleigh index distribution. To get the local Rayleigh index distribution, the line-of-sight images were inverted by tomographic method, such as Abel do-convolution. Another aim is to investigate the validity of using OH chemiluminescence acquired with an ICCD as a qualitative measure of local heat release. For constant inlet velocity and temperature, the overall intensities of OH emission acquired at different equivalence ratio showed periodic and higher value at high equivalence ratio. OH intensity averaged over one period of pressure increased exponentially with equivalence ratio. Local Rayleigh index distribution clearly showed the region of amplifying or damping the combustion instability as equivalence ratio increased. It could provide an information/insights on active control such as secondary fuel injection. Finally, local heat release rate derived from reconstructed OH images were presented fur typical locations.

Actinometry에 의한 CF4플라즈마에서의 F라디칼의 공간분포

  • Lee, U-Hyeon;Jeong, Jae-Cheol;Kim, Dong-Hyeon;Kim, Hyeok;Hwang, Gi-Ung
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2011.02a
    • /
    • pp.217-217
    • /
    • 2011
  • 플라즈마를 이용하는 식각 및 증착등의 반도체공정에 있어서 최근에는 기판의 크기가 점차 증가하는 추세에 있다. 이러한 대면적 플라즈마 발생장치 내에서 플라즈마 밀도와 라디칼 농도의 공간적인 특성을 이해하는 것에 대한 중요성이 더해지고 있다. 이를 위해 Langmuir probe와 같은 전기적 접근법에 의한 진단방법이나 광학적 접근법에 의한 진단방법에 대한 연구가 이루어 졌다. 전기적 접근법에 의한 플라즈마의 진단방법은 원리가 간단하고 정확도가 높다는 장점이 있지만 진단 장치에 의한 플라즈마의 간섭이 크고 식각가스의 경우 진단이 어렵다는 단점이 있다. 그에 비해 광학적 진단방법은 플라즈마에 간섭이 많지 않은 방법으로 알려져 있고 레이저 형광법(LIF), 원적외선 레이저 흡수 분광법(IR laser Absorption Spectroscopy), 광량측정법(Actinometry)등이 있다. 이 중 레이저 형광법, 원적외선 레이저 흡수 분광법의 경우, 진단장치가 매우 복잡하고 가격이 비싸다는 단점을 가지고 있다. 반면 광량측정법의 경우 다른 광학적 접근법에 의한 진단방법에 비해 원리와 실험장치가 간단하고 공간적인 라디칼 분포의 진단이 쉽다는 점에서 장점을 가지고 있다. Actinometry는 Ar과 같은 불활성 기체를 작은 비율을 넣어서 여기 된 불활성 기체의 파장세기와 여기 된 측정 라디칼의 파장세기의 비교를 통해 상대밀도를 측정하는 방법이다. 이 측정 방법에 Abel's inversion equation을 적용함으로 해서 대면적 M-ICP(Magnetized - Induced Coupled Plasma)에서 식각가스인 $CF_4$플라즈마에서 F 라디칼 농도의 공간적인 분포를 측정하고 분석하였다. 또한 플라즈마의 압력, 소스 전력 값과 기판 전력 값등의 조건의 변화에 따라 F 라디칼 농도의 분포가 어떻게 달라지는지에 대해 측정 분석하여 다루었다.

  • PDF

Effects of Partial Premixing on Flame Structure and NOx Emission Characteristics in an Unstable Gas Turbine Combustor (불안정 가스 터빈 연소기에서 부분 예혼합이 화염구조와 NOx 배출 특성에 미치는 영향)

  • Lee Jae-Ho;Lee Jong-Ho;Kim See-Hyun;Chang Young-June;Jeon Chung-Hwan
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2005.11a
    • /
    • pp.437-444
    • /
    • 2005
  • Experiments were carried out in an atmospheric pressure, lab-scale gas turbine combustor to see the effect of partial premixing on unstable flame structure and Nox emission characteristics. The swirl angle is 45 deg., fuel-air mixing degrees were varied 0, 50 and 100% respectively at equivalence ratio ranging from 0.53 to 0.79. The evolution of phased-locked OH chemiluminescence images were acquired with an ICCD. NOx emission characteristics were also investigated at each experimental condition. The effect of the fuel-air mixing degree on the flame structure was obtained from phase-locked $OH^*$ images. And it was obtained from local heat release characteristics that the information about the region which the combustion instability was amplified or damped. It also could be confirmed that $\sigma$ has greatly influence on NOx emission characteristics at lean regimes. It would be expected that it could provide invaluable data for understanding the mechanism of combustion instability.

  • PDF

반도체 공정 플라즈마의 밀도 균일성 분석을 위한 공간 분해 발광 분광기

  • O, Chang-Hun;Ryu, Hun-Cheol;Lee, Hyeong-U;Kim, Se-Yeon;Lee, Heon-Jeong;Han, Jae-Won
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2010.02a
    • /
    • pp.412-412
    • /
    • 2010
  • 플라즈마는 미세 전기 소자 제작에 있어 박막의 증착, 식각, 세정등 여러 가지 공정에서 널리 사용되고 있다. 미세 소자의 선폭의 감소와 높은 생산성을 위한 웨이퍼 면적의 대형화가 진행됨에 따라 플라즈마의 균일도는 공정 수율 향상의 관점에서 중요한 요소로 그것의 계측과 공정 중 실시간 감시에 필요성이 부각되고 있다. 플라즈마에 존재하는 라디칼의 밀도, 이온의 밀도, 전자 온도 등의 웨이퍼 상에서의 공간 분포와 공정 결과물과의 상관관계에 대한 연구는 현재까지 다양하게 진행 되었으며 특히, 라디칼의 공간 분포가 공정 결과물의 균일도와 큰 상관 관계가 있는 것으로 알려져 있다. 라디칼의 농도 분포를 계측은 레이저 유도 형광법, 발광 분광법, 흡수 분광법 등을 통하여 이루어져 왔으며, 특히 발광 분광법의 경우 계측의 민감성, 편의성등을 이유로 가장 널리 사용되고 있다. 그러나 현재 까지 진행된 발광 분광법을 이용한 라디칼의 공간 분포 계측은 그 자체로 공간 분포를 계측하는 것이 아닌 플라즈마 밀도의 축 대칭성을 가정하여 Abel inversion을 적용하거나, 광섬유를 플라즈마에 직접 삽입하는 방식을 사용하기 때문에 실제 반도체 제작공정을 비롯한 미세소자 공정 플라즈마의 라디칼 밀도 분포를 실시간, 비 접촉 방식으로 계측 하는데 한계가 있다. 본 연구에서는 반도체 공정 플라즈마의 밀도 균일성 분석을 위한 공간 분해 발광 분광기를 제안한다. 기존의 발광 분광법과 비교하여 공간 분해능 향상을 위하여 직렬로 설치된 다수의 렌즈, 개구, 그리고 핀홀을 이용하였다. 공간 분해 발광 분광기의 공간 분해능을 계산하였으며, 실험을 통하여 검증 하였다. 또, HDP CVD를 이용한 $SiO_2$ 박막 증착 공정에서 산소 라디칼의 농도와 증착된 박막의 두께 분포의 상관 관계를 계측 함으로써 공간 분해 발광 분광기의 플라즈마 공정 적용 가능성 입증 하였다.

  • PDF

Experimental Study on Dilution Effect of Exhaust Gas in SNG Combustion on a Model Gas Turbine (가스터빈에서 SNG 연료 조성에 대한 희석제의 배기배출물 저감효과에 대한 실험적 연구)

  • Joo, Seongpil;Yoon, Jisu;Kim, Jeongjin;Kim, Seongheon;Yoon, Youngbin
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.44 no.7
    • /
    • pp.603-610
    • /
    • 2016
  • This paper describes experimental results about emission and NOx reduction of dilution effect (Nitrogen and carbon dioxide) about various fuel compositions of synthetic natural gas (SNG). Combustion experiment was performed to investigate the combustion characteristics for SNG with various hydrogen ratio in SNG, heat input and equivalence ratio in a partially premixed model gas turbine combustor. NOx emission was similar to each hydrogen ratio and flame characteristics was investigated from OH chemiluminescence images. There was a singularity of CO emission in stoichiometric condition and it can be identified using OH chemiluminescence intensity. In addition, dilution effect was studied in using nitrogen and carbon dioxide as diluent to reduce the NOx emission. Carbon dioxide diluent was more effective to NOx reduction than nitrogen diluent because of its high diluent specific heat and its heat capacity.