• Title/Summary/Keyword: Abdomen CT

Search Result 203, Processing Time 0.024 seconds

Evaluation 4D-CT Simulation used of Motion Organ and Tumor for Respiratory Gated Radiation Therapy (호흡동조방사선치료를 위한 4D-CT simulation을 이용한 동적장기와 종양 움직임 평가)

  • Kim, Seung-Chul;Kim, Min-A
    • The Journal of the Korea Contents Association
    • /
    • v.15 no.9
    • /
    • pp.395-402
    • /
    • 2015
  • when the radiation therapy of chest and abdomen, evaluation of the tumor motion and the data was used to minimize damage to normal tissues by separating the tumor and normal tissue and maximize tumor therapeutic effect. Lung and liver cancer each 20 patients based on the 50% top phase using 4D-CT simulation and Light speed-16 of shooting equipment 30 ~ 70 % gating phase interval and 0 ~90 % movement in the full phase interval was measured. If the full phase 0 ~ 90% with gating phase 30~70% of tumors in the liver and lung is shown the biggest difference compared to the motion and the size of the GTV was the largest difference in the I(inferior), full phase 0~90% degree of tumor motion only when a relatively large, gating phase to 30~70% of the tumor when the movement has been found that the reduced average 7.1mm. In the 4D-CT simulation comparing the motion value when the full phase 0~90 % and gating phase 30~70 % when the motion value, twice in the gating phase 30~70 % more than full phase 0~90 % showed a small movement value. The exposure to normal tissues, based on the results obtained from the 4D-CT simulation can be significantly alleviated, After treatment will reduce pain and disability in patients with radiation is expected to be able to effective treatment.

Deep Learning-Based Computed Tomography Image Standardization to Improve Generalizability of Deep Learning-Based Hepatic Segmentation

  • Seul Bi Lee;Youngtaek Hong;Yeon Jin Cho;Dawun Jeong;Jina Lee;Soon Ho Yoon;Seunghyun Lee;Young Hun Choi;Jung-Eun Cheon
    • Korean Journal of Radiology
    • /
    • v.24 no.4
    • /
    • pp.294-304
    • /
    • 2023
  • Objective: We aimed to investigate whether image standardization using deep learning-based computed tomography (CT) image conversion would improve the performance of deep learning-based automated hepatic segmentation across various reconstruction methods. Materials and Methods: We collected contrast-enhanced dual-energy CT of the abdomen that was obtained using various reconstruction methods, including filtered back projection, iterative reconstruction, optimum contrast, and monoenergetic images with 40, 60, and 80 keV. A deep learning based image conversion algorithm was developed to standardize the CT images using 142 CT examinations (128 for training and 14 for tuning). A separate set of 43 CT examinations from 42 patients (mean age, 10.1 years) was used as the test data. A commercial software program (MEDIP PRO v2.0.0.0, MEDICALIP Co. Ltd.) based on 2D U-NET was used to create liver segmentation masks with liver volume. The original 80 keV images were used as the ground truth. We used the paired t-test to compare the segmentation performance in the Dice similarity coefficient (DSC) and difference ratio of the liver volume relative to the ground truth volume before and after image standardization. The concordance correlation coefficient (CCC) was used to assess the agreement between the segmented liver volume and ground-truth volume. Results: The original CT images showed variable and poor segmentation performances. The standardized images achieved significantly higher DSCs for liver segmentation than the original images (DSC [original, 5.40%-91.27%] vs. [standardized, 93.16%-96.74%], all P < 0.001). The difference ratio of liver volume also decreased significantly after image conversion (original, 9.84%-91.37% vs. standardized, 1.99%-4.41%). In all protocols, CCCs improved after image conversion (original, -0.006-0.964 vs. standardized, 0.990-0.998). Conclusion: Deep learning-based CT image standardization can improve the performance of automated hepatic segmentation using CT images reconstructed using various methods. Deep learning-based CT image conversion may have the potential to improve the generalizability of the segmentation network.

A Case of Complete Remission after Palliative Chemotherapy and Salvage Radiotherapy for Lymph Node Recurrence in Advanced Gastric Cancer (근치적 절제술 후 림프절 재발이 발생한 진행성 위암에 대한 고식적 치료 1례)

  • Jong Seok Joo;Hyun Yong Jeong;Hee Seok Moon;Jae Kyu Sung;Sun Hyung Kang
    • Journal of Digestive Cancer Research
    • /
    • v.3 no.2
    • /
    • pp.108-112
    • /
    • 2015
  • A 54-year-old male patient who was diagnosed with advanced gastric cancer underwent a distal gastrectomy, D2 lymph node dissection, and adjuvant chemoradiotherapy. After a year, in a follow-up PET-CT, lymph node metastases were observed in the neck and abdomen, and therefore, the patient underwent chemotherapy. After treatment, the follow-up PET-CT revealed a growth of the posterior neck lymph node. Thus, an excisional biopsy was performed, and the growth was diagnosed as metastatic adenocarcinoma. Therefore, the patient received chemotherapy with FOLFIRI. Another follow-up PET-CT after chemotherapy revealed a growth in the right inguinal lymph node, and the patient underwent salvage radiotherapy for this lesion. The PET-CT taken for the response evaluation showed no evidence of further metastasis of the lymph node. We hereby report a case of advanced gastric cancer with neck and inguinal lymph node recurrence showing complete remission after palliative chemotherapy and salvage radiotherapy.

  • PDF

Comparison of a Deep Learning-Based Reconstruction Algorithm with Filtered Back Projection and Iterative Reconstruction Algorithms for Pediatric Abdominopelvic CT

  • Wookon Son;MinWoo Kim;Jae-Yeon Hwang;Young-Woo Kim;Chankue Park;Ki Seok Choo;Tae Un Kim;Joo Yeon Jang
    • Korean Journal of Radiology
    • /
    • v.23 no.7
    • /
    • pp.752-762
    • /
    • 2022
  • Objective: To compare a deep learning-based reconstruction (DLR) algorithm for pediatric abdominopelvic computed tomography (CT) with filtered back projection (FBP) and iterative reconstruction (IR) algorithms. Materials and Methods: Post-contrast abdominopelvic CT scans obtained from 120 pediatric patients (mean age ± standard deviation, 8.7 ± 5.2 years; 60 males) between May 2020 and October 2020 were evaluated in this retrospective study. Images were reconstructed using FBP, a hybrid IR algorithm (ASiR-V) with blending factors of 50% and 100% (AV50 and AV100, respectively), and a DLR algorithm (TrueFidelity) with three strength levels (low, medium, and high). Noise power spectrum (NPS) and edge rise distance (ERD) were used to evaluate noise characteristics and spatial resolution, respectively. Image noise, edge definition, overall image quality, lesion detectability and conspicuity, and artifacts were qualitatively scored by two pediatric radiologists, and the scores of the two reviewers were averaged. A repeated-measures analysis of variance followed by the Bonferroni post-hoc test was used to compare NPS and ERD among the six reconstruction methods. The Friedman rank sum test followed by the Nemenyi-Wilcoxon-Wilcox all-pairs test was used to compare the results of the qualitative visual analysis among the six reconstruction methods. Results: The NPS noise magnitude of AV100 was significantly lower than that of the DLR, whereas the NPS peak of AV100 was significantly higher than that of the high- and medium-strength DLR (p < 0.001). The NPS average spatial frequencies were higher for DLR than for ASiR-V (p < 0.001). ERD was shorter with DLR than with ASiR-V and FBP (p < 0.001). Qualitative visual analysis revealed better overall image quality with high-strength DLR than with ASiR-V (p < 0.001). Conclusion: For pediatric abdominopelvic CT, the DLR algorithm may provide improved noise characteristics and better spatial resolution than the hybrid IR algorithm.

Comparative Analysis of Absorption Doses between Exposed and Unexposed Area on Major Organs During CT Scan (전산화 단층촬영시 주선속내 외의 주요장기 흡수선량 비교분석)

  • 사정호;서태석;최보영;정규회
    • Progress in Medical Physics
    • /
    • v.11 no.1
    • /
    • pp.59-71
    • /
    • 2000
  • It is possible to obtain a fast CT scan during breath holding with spiral technique. But the risk of radiation is increased due to detailed and repeated scans. However, the limitation of X-ray doses is not fully specified on CT, yet. Therefore, the purpose of the present study is to define the limitation of X-ray doses on CT The CT unit was somatom plus 4. Alderson Rando phantom, Solenoid water phantom, TLD, and reader were used. For determining adequate position and size of organs, the measurement of distance(${\pm}$2mm) from the midline of vertebral body was performed in 40 women(20~40 years). On the brain scan for 8:8(8mm slice thickness, 8mm/sec movement velocity of the table) and 10:10(10mm slice thickness, 10mm/sec movement velocity of the table) methods, the absorption doses of exposed area of the 10:10 were slightly higher than those of 8:8. The doses of unexposed uterus were negligible on the brain scan for both 8:8 and 10:10. On the chest scan for 8:8, 8:10(8mm slice thickness, 10mm/sec movement velocity of the table), 10:10, 10:12(10mm slice thickness, 12mm/sec movement velocity of the table) and 10:15(10mm slice thickness, 15mm/sec movement velocity of the table) methods, 8:8 method of the absorption doses of exposure area was the most highest and 10:15 method was the most lowest. The absorption doses of 8:10 method was relatively lower than those of the other methods. In conclusion, the 8:10 method is the most suitable to give a low radiation burden to patient without distorting image quality.

  • PDF

Comparison of Radiation Dose in the Measurement of MDCT Radiation Dose according to Correction of Temperatures and Pressure, and Calibration of Ionization Chamber (MDCT 선량측정에서 온도와 압력에 따른 보정과 Ionization Chamber의 Calibration 전후 선량의 비교평가)

  • Lee, Chang-Lae;Kim, Hee-Joung;Jeon, Seong-Su;Cho, Hyo-Min;Nam, So-Ra;Jung, Ji-Young;Lee, Young-Jin;Lee, Seung-Jae;Dong, Kyung-Rae
    • Progress in Medical Physics
    • /
    • v.19 no.1
    • /
    • pp.49-55
    • /
    • 2008
  • This study aims to conduct the comparative analysis of the radiation dose according to before and after the calibration of the ionization chamber used for measuring radiation dose in the MDCT, as well as of $CTDI_w$ according to temperature and pressure correction factors in the CT room. A comparative analysis was conducted based on the measured MDCT (GE light speed plus 4 slice, USA) data using head and body CT dosimetric phantom, and Model 2026C electrometer (RADICAL 2026C, USA) calibrated on March 21, 2007. As a result, the $CTDI_w$ value which reflected calibration factors, as well as correction factors of temperature and pressure, was found to be the range of $0.479{\sim}3.162mGy$ in effective radiation dose than the uncorrected values. Also, under the routine abdomen routine CT image acquisition conditions used in reference hospitals, patient effective dose was measured to indicate the difference of the maximum of 0.7 mSv between before and after the application of such factors. These results imply that the calibration of the ion chamber, and the correction of temperature and pressure of the CT room are crucial in measuring and calculating patient effective dose. Thus, to measure patient radiation dose accurately, the detailed information should be made available regarding not only the temperature and pressure of the CT room, but also the humidity and recombination factor, characteristics of X-ray beam quality, exposure conditions, scan region, and so forth.

  • PDF

Evaluation of Image Quality According to Presence or Absence of Upper limbs in Scan Field of View During CT Examinations (Including LUNG MAN) (CT 검사 시 스캔 범위 내 상지 유무에 따른 영상의 질 평가(LUNG MAN 포함))

  • Zhang, Yuying;Zheng, Haoyang;Jung, Kang-gyo;Cho, Yu-Jin;Cho, Pyong-Kon
    • Journal of radiological science and technology
    • /
    • v.40 no.4
    • /
    • pp.567-573
    • /
    • 2017
  • The purpose of this study was to evaluate whether or not there was artifact when the upper limb could not be lifted to the top of the head during multi-detector computed tomography(MDCT) scans of the chest and abdomen. Contrast radiography of the human and chest phantom was performed with 128channal MDCT. Under the same conditions(120 kVp, 110 mAs, standard algorithm)both hands lifted up and put down each time in the human experiment. In the chest phantom experiment, the radiography was carried out when the upper limb phantom was adjusted at a certain distance(0, 3, 7 cm) from the chest phantom. Subsequently, the values of Noise, CT number, SNR, and CNR were measured in the field of concern. The noise value of fat, rib, and muscle increased when the arm was lifted in humans(0.79, 47.8, 27%). Furthermore, when the upper limb was lowered, the noise value of muscle and lung increased in the phantom(31.2, 9.4%). In addition, the noise value of the muscles and lung decreased by 5, 25.12% and 5.6, 15.35% as the upper limb moved about 0,3,7cm away from the chest. When the chest and abdominal radiography were performed, in the case of the presence of other parts outside the inspection area, the probability of artifact was minimal while the distance was more than 3cm away from the upper limb to the chest and abdomen.

Effect of Work Improvement for Promotion of Outpatient Satisfaction on CT scan (CT 외래환자의 만족도 향상을 위한 업무개선 연구)

  • Han, Man-Seok;Lee, Seung-Youl;Lee, Myeong-Goo;Jeon, Min-Cheol;Cho, Jae-Hwan;Kim, Tae-Hyung
    • Journal of radiological science and technology
    • /
    • v.35 no.1
    • /
    • pp.45-50
    • /
    • 2012
  • Nowadays, most of the hospital serves "one stop service" for CT scan. The patients could be taken the CT scan in the day they register for scan. On the contrary to the time convenience, patients are not satisfied with long waiting time and unkindness of staff. The objective of this study is to improve the patient's satisfaction for the CT scan, by analyzing inconvenience factors and improving the service qualities. From April 1 to August 30 in 2011, we investigated the satisfaction of patients who did examined abdomen CT scan with contrast media. We analyzed the 89 questionnaires before and after the service improvements from them. The worker's kindness, the environment of CT room and understanding about CT scan were answered by questionnaire and the waiting time of a day CT scan was drawn by medical information statistics. Also, the period before improvement was from April to June and the period after improvement was from July to September. And these questionnaire was analyzed through SPSS V. 15.0. In this study, kindness of staff, environment of CT room, intelligibility for CT scan and waiting time was explored and analyzed by SPSS V.15.0. The score of kindness was improved by 32%, satisfaction level of the environment was improved by 52.54%. The understanding level about CT scan was improved by 52.36% and the wating time of a day CT was shortened by 21% through our service enhancement programs. Consequentially, it is considered that these efforts would contribute to increase the revenue of hospital.

A Case of Pulmonary and Retroperitoneal Lymphangioleiomyomatosis (폐와 후복강에 발생한 림프관평활근종증 1예)

  • Kwak, Nam-Ju;Park, Nam-Gu;Kim, He-Young;Choe, Gi-Won;Eom, Je-Ho;Kim, Dong-Un;Cho, Meong-Chan;Yun, Se-Jin;Kim, Sung-Taek;Lee, Sang-Do
    • Tuberculosis and Respiratory Diseases
    • /
    • v.42 no.4
    • /
    • pp.600-604
    • /
    • 1995
  • Lymphangioleiomyomatosis, a rare disease in women of childbearing age, is the result of benign nodular hypertrophy of the smooth muscle of the lypmhatics and other tissues of the abdomen and thorax. We report a 36-years-old woman with pulmonary and retroperitoneal lymphangioleiomyomat.osis who responded with hormone treatment. She developed vaginal pruritis and a pelvic ultraound was done given her significant past medical history. Ultrasound examination demonstrated a large mass in the right side of her pelvis. Therefore she was admitted to St. Michael's Hospital in Toronto for laparoscopy. Result of cytology was to be consistent with the diagnosis of retroperitoneal lymphangioleiomyomatosis. High resolution CT sacn of the thorax demonstrated multiple small cystic lesions, without associated nodularity compatible with a diagnosis of pulmonary lymphangioleiomyomatosis. She has been taking Provera tablets 100mg po tid since Dec. 15, 1993. We have given her a prescription for Depo provera 500mg IM monthly since she came back to Korea. and made arrangements for regular follow up monthly. We performed chest X-ray, CT of chest(high resolution), abdomen and pelvis, pulmonary function tests and arterial blood gas analysis. Chest X-ray and CT findings showed no significant change since July. 20, 1993.

  • PDF

Automatic Liver Segmentation of a Contrast Enhanced CT Image Using a Partial Histogram Threshold Algorithm (부분 히스토그램 문턱치 알고리즘을 사용한 조영증강 CT영상의 자동 간 분할)

  • Kyung-Sik Seo;Seung-Jin Park;Jong An Park
    • Journal of Biomedical Engineering Research
    • /
    • v.25 no.3
    • /
    • pp.189-194
    • /
    • 2004
  • Pixel values of contrast enhanced computed tomography (CE-CT) images are randomly changed. Also, the middle liver part has a problem to segregate the liver structure because of similar gray-level values of a pancreas in the abdomen. In this paper, an automatic liver segmentation method using a partial histogram threshold (PHT) algorithm is proposed for overcoming randomness of CE-CT images and removing the pancreas. After histogram transformation, adaptive multi-modal threshold is used to find the range of gray-level values of the liver structure. Also, the PHT algorithm is performed for removing the pancreas. Then, morphological filtering is processed for removing of unnecessary objects and smoothing of the boundary. Four CE-CT slices of eight patients were selected to evaluate the proposed method. As the average of normalized average area of the automatic segmented method II (ASM II) using the PHT and manual segmented method (MSM) are 0.1671 and 0.1711, these two method shows very small differences. Also, the average area error rate between the ASM II and MSM is 6.8339 %. From the results of experiments, the proposed method has similar performance as the MSM by medical Doctor.