• Title/Summary/Keyword: AVF

Search Result 62, Processing Time 0.015 seconds

Sequential Pituitary Hormone Responses to Electroconvulsive Therapy (전기경련요법후 뇌하수체 호르몬의 순차적인 분비 반응)

  • Kim, Doh Kwan;Kim, Soo Jeong;Choi, Do Sun;Bok, Hae-Sook;Kim, Seungtai Peter
    • Korean Journal of Biological Psychiatry
    • /
    • v.3 no.2
    • /
    • pp.288-294
    • /
    • 1996
  • Background : Most studies of the pituitary hormonal responses to electroconvulsive therapy(ECT) have used limited blood sampling schedules. Little is known about the precise sequence of neuroendocrine events immediately following en ECT application. or about the regulation of the hormonal responses. Methods : Blood was sampled at three minute intervals from eleven patients(two schizophrenics and nine affective disorder patients) undergoing ECT. Each sample was immunologically assayed for arginine vasopressin(AVP), adrenocorticotropic hormone(ACTH), prolactin(PRL), and cortisol. Baseline hormone concentrations and several measures of response were determined for each hormone. The temporal and quantitative relationships among the hormonal responses were determined. Correlations were calculated between seizure duration and secretory responses. Results : All four hormones demonstrated significant secretory responses to ECT, with AVP increasing from 1.2 to 33.3pg/ml(P<0.001), ACTH from 5.4 to 32.3fmol/ml(P<0001). PRL from 21.8 to 102.2ng/ml(P<0.005) and cortisol from 20.1 to 31.1ug/dl(P<0.001). The three pituitary hormones showed consistent time courses of secretion with onset of responses by three minutes but clearly differing peak times of 3, 6, and 12-15 minutes for AVP, ACTH, and PRL, respectively. Cortisol began to rise after 6minutes and pecked between 20-30minutes. There ware no significant correlations between seizure duration and any of the secretory response measures. Conclusions : 1) The pituitary hormone response to ECT is sequential rather than synchronous 2) The AVP response was extremely rapid and more massive than those of any other hormones. 3) The ACTH response of this study was more rapid and mare robust than thai revealed by the mast of past studies. 4) The results strongly suggest that the pituitary hormones are released as a result of the seizure rather tho, the electrical stimulus. 5) The sequential pattern of responses suggests that neuroendocine feedback-regulatory mechanisms determine the response profile.

  • PDF

Evaluation of Patient Radiation Doses Using DAP Meter in Interventional Radiology Procedures (인터벤션 시술 시 면적선량계를 이용한 환자 방사선 선량 평가)

  • Kang, Byung-Sam;Yoon, Yong-Su
    • Journal of radiological science and technology
    • /
    • v.40 no.1
    • /
    • pp.27-34
    • /
    • 2017
  • The author investigated interventional radiology patient doses in several other countries, assessed accuracy of DAP meters embedded in intervention equipments in domestic country, conducted measurement of patient doses for 13 major interventional procedures with use of Dose Area Product(DAP) meters from 23 hospitals in Korea, and referred to 8,415 cases of domestic data related to interventional procedures by radiation exposure after evaluation the actual effectives of dose reduction variables through phantom test. Finally, dose reference level for major interventional procedures was suggested. In this study, guidelines for patient doses were $237.7Gy{\cdot}cm^2$ in TACE, $17.3Gy{\cdot}cm^2$ in AVF, $114.1Gy{\cdot}cm^2$ in LE PTA & STENT, $188.5Gy{\cdot}cm^2$ in TFCA, $383.5Gy{\cdot}cm^2$ in Aneurysm Coil, $64.6Gy{\cdot}cm^2$ in PTBD, $64.6Gy{\cdot}cm^2$ in Biliary Stent, $22.4Gy{\cdot}cm^2$ in PCN, $4.3Gy{\cdot}cm^2$ in Hickman, $2.8Gy{\cdot}cm^2$ in Chemo-port, $4.4Gy{\cdot}cm^2$ in Perm-Cather, $17.1Gy{\cdot}cm^2$ in PCD, and $357.9Gy{\cdot}cm^2$ in Vis, EMB. Dose referenece level acquired in this study is considered to be able to use as minimal guidelines for reducing patient dose in the interventional radiology procedures. For the changes and advances of materials and development of equipments and procedures in the interventional radiology procedures, further studies and monitorings are needed on dose reference level Korean DAP dose conversion factor for the domestic procedures.