• Title/Summary/Keyword: ATS-539 다목적 초음파팬텀

Search Result 3, Processing Time 0.015 seconds

Evaluation of Image Quality using ATS-539 Phantom and SNR in the Ultrasonographic Equipment (ATS-539 다목적 팬텀과 SNR을 이용한 초음파 영상평가)

  • Kim, Min-Ju;Lee, Jin-Soo;Ko, Seong-Jin;Kang, Se-Sik;Kim, Jung-Hoon;Kim, Dong-Hyun;Kim, Changsoo
    • The Journal of the Korea Contents Association
    • /
    • v.13 no.8
    • /
    • pp.284-291
    • /
    • 2013
  • The importance of ultrasound examination in the field of medical imaging has been emphasized and the interest in sonographic image evaluation is growing. However image evaluations by the non-standardized criteria and methods, so establishment of legal provisions and objective evaluation criteria are needed. In this study, we used SNR to find out more quantitative way and supplement the limitations of the existing phantom image evaluation. The results of acquired 8 images using ATS-539 multipurpose phantom were compared in SNR of sensitivity and gray-scale dynamic range. In the result of the experiment, excellent equipment of existing phantom images are G1, S1 and G2 in regular sequence. In SNR of sensitivity, G1, S1 and G2 and in SNR of gray-scale dynamic range, S1 G1 and G2 in order. In the conclusion, all the experiment results did not show big difference and regular pattern neither. Therefore, the new evaluation measures should be used with the existing phantom image evaluation method for more objective and quantitative evaluation of the ultrasound imaging device.

Evaluation of Quantitative Image Quality using Frequency and Parameters in the Ultrasound Image (초음파영상에서 주파수와 파라미터를 이용한 정량적 영상평가)

  • Kim, Changsoo;Kang, Se Sik;Kim, Junghoon
    • Journal of the Korean Society of Radiology
    • /
    • v.10 no.4
    • /
    • pp.247-253
    • /
    • 2016
  • Ultrasound devices diagnose many disease, which is widely used, can not be standardized quantitative evaluated in order to evaluate sonography image of quality. Therefore, in this papers, aims to get correct image in order to accurate diagnosis by figuring out the appropriate parameter based on each target by measuring distortion which results in the analyzation of the sensitivity of SNR and the histogram of signal by manipulating parameter of 8 mm target in ATS-539 multipurpose phantom. Equipment using Acuson sequoia 512, convex probe and utilizes multi-objective phantom. experiment method is that first you put the phantom on the flat and acquire 85 sheets of image, changing frequency(2,3,4 MHz, harmonic 3, 4, 4.5 MHz), Focus(2, 4, 6 unit), and Dynamic Range(58, 68, 78, 88, 98) for a 8 mm structure. through the Image J program. The sensitivity angle of 8mm target through Image J program is gauged by each separate target SNR and the distorted angle subtract and measure Histogram of background from Histogram of signal and take top 40% from the given result value above. According to parameter variation we found out proper parameter by acquiring SNR of sensitivity and distortion data for aspect of transition. The more this findings have Focus, the lower distortion value and at 4 MHz frequency this result have high SNR and low distortion value. Dynamic Range got an appropriate image on 88 and 98. It is considered on the basis of the experimental data, the probability of disease diagnosis will get higher.

A Study on Effectiveness of Designed Composite Filter with Noise Reduction in Ultrasound Image for Diffuse Liver Disease (미만성 간질환의 초음파 영상에서 노이즈 감소를 위한 복합필터의 설계 및 유용성에 관한 연구)

  • Lee, Jin-Soo;Kim, Changsoo;Im, In-Chul;Yang, Sung-Hee
    • Journal of the Korean Society of Radiology
    • /
    • v.11 no.2
    • /
    • pp.69-77
    • /
    • 2017
  • This paper proposes a composite filter for noise reduction of image. To improve the image quality by reducing the noise in the liver ultrasound image, we tried to help the accurate image analysis. In the experiment, the top seven composite filters were selected by combining the Gaussian blur filter, the sharpening filter, and the median filter using the ATS-539 ultrasonic phantom, and applied to the ultrasound image in which this was done. As a result, it was found that the values of SNR, CNR and MSR all increased when the top seven composite filters were applied. In addition, PSNR of more than 30 dB, close to SSIM 1 showed that the image loss rate is small. Therefore, the appropriate application of the proposed composite filter in this research will be useful for accurate video reading and analysis.