• Title/Summary/Keyword: ATR-FTIR

Search Result 151, Processing Time 0.037 seconds

Phosphate Adsorption-Desorption of Kaolinite KGa-2 (Source Clay) (카올리나이트 KGa-2 (표준 점토)의 인산염 흡착-탈착 특성)

  • Cho, Hyen-Goo;Choi, Jae-Ho;Moon, Dong-Hyuk;Kim, Soo-Oh;Do, Jin-Youn
    • Journal of the Mineralogical Society of Korea
    • /
    • v.21 no.2
    • /
    • pp.117-127
    • /
    • 2008
  • The characteristics of phosphate adsorption-desorption on kaolinite was studied by batch adsorption experiments and detailed adsorbed state of phosphate on kaolinite surface was investigated using ATR-FTIR (Attenuated Total Reflectance-Fourier Transform Infrared) spectroscopy. The phosphorous contents were measured using UV-VIS-IR spectrophotometer with 820 nm wavelength. The adsorbed P was generally increased with increasing pH value in the range of pH 4 to pH 9, however it is not distinct. Moreover the adsorbed P was significantly changed with different initial phosphate concentration. The adsorption isotherms were well fitted with the Langmuir equation, Temkin equation, and Freundlich equation in descending order. The maximum Langmuir adsorption capacity of kaolinite KGa-2 is 232.5 ($204.1{\sim}256.5$) mg/kg and has very higher value than that of kaolinite KGa-1b. Most of adsorbed phosphate on kaolinite were not easily desorbed to aqueous solution, but might fixed on kaolinite surface. However it needs further research about the exact desorption experiment. It was impossible to recognize phosphorous adsorption bands on kaolinite in ATR-FTIR spectrum from kaolinite bands themselves, because the absorption peaks of phosphorous have very similar positions with those of kaolinite, and the intensities of the former were very weak in comparison with those of the latter.

Nanoparticle의 분산 안정도에 따른 ATR-FTIR 분석법을 이용한 증착소재 흡착특성연구

  • Kim, Jong-Ho;Park, Jae-Seo;shahzad, Rauf;Lee, Chang-Hui;Sin, Jae-Su;Gang, Sang-U
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2016.02a
    • /
    • pp.113-113
    • /
    • 2016
  • 반도체 산업이 발전하고 기술이 향상됨에 따라 미세화되고 복잡한 구조의 소자가 개발되고 있으며, 2차원 소재 등 다양하고 새로운 소재들이 발견 및 연구되고 있다. 새로운 소재 또는 기술을 이용한 고품질 소자를 개발하기 위해서는 우수한 특성(높은 순도, 우수한 분해 및 반응 특성)을 지닌 증착소재의 개발 및 평가가 선행되어야 한다. 기존의 증착소재의 기본 물성을 측정하는 방법인 단순 기상 Fourier transform infrared spectroscopy(FT-IR) 분석법은 실제 공정에서의 증착경향을 대변하기 어렵다는 단점이 있다. 이러한 단점을 보완하기 위해 개조된 attenuated total reflection (ATR) 액세서리를 이용하여 실제 공정에서의 증착경향을 대변하고자 하였다. 본 연구에서는 반도체 증착소재의 분해 및 표면 흡착 특성을 분석하기 위해 ATR-FTIR 분석법을 이용하여 수행하였으며, 분산안정도에 따른 nanoparticle을 ATR의 크리스탈 표면에 분포시켜 hexamethyldisilazane(HMDS) source의 흡착 효율을 향상시키는 연구를 수행하였다. Nanoparticle의 분산안정도를 높이기 위하여 suspension 상태에서 pH, sonication, 분산제를 이용하였으며, nanoparticle을 ATR crystal 표면에 분포하여 분석한 결과, 분산안정도에 따라 HMDS의 흡착효율이 달라짐을 확인하였다.

  • PDF

Thermally induced three dimensional orientation change of oriented PTN films by temperature-controlled polarized FTIR-ATR (Temperature-controlled polarized FTIR-ATR를 이용한 배향된 PTN필름의 열에 의한 3차원적 배향구조 변화)

  • 양영일;김영호;이한섭
    • Proceedings of the Korean Fiber Society Conference
    • /
    • 2003.10b
    • /
    • pp.207-208
    • /
    • 2003
  • 일반적으로 결정성 고분자에 공정에 있어서 배향 및 결정화 거동은 두 가지 중요한 공정 프로세스로써 고분자의 모폴로지 및 결정구조형성에 매우 큰 영향을 미치며 최종적으로 고분자의 거시적인 물성에 영향을 준다. 고분자 물질의 물리적 특성을 정확하게 이해하여 최적의 물성을 나타내는 내부 구조를 제시하기 위하여서는 고분자 물질의 배양분석에 있어서 분자의 2차원적 배향 상태뿐만 아니라 전체적인 3차원 배향 상태에 관한 정보가 필수적이다. (중략)

  • PDF

Surface Treatment of Polypropylene using a Large Area Atmospheric Pressure Plasma-solution System (대면적 대기압 플라즈마-용액 시스템을 이용한 폴리프로필렌 표면 처리)

  • Tran, Chinh Quoc;Choi, Ho-Suk
    • Korean Chemical Engineering Research
    • /
    • v.49 no.3
    • /
    • pp.271-276
    • /
    • 2011
  • We investigated the possibility of introducing functional groups without damaging surface polymeric chains through the treatment of a polypropylene(PP) film immersed in liquid phase using an atmospheric pressure plasma with large area. The ionic liquid of 1-butyl-3-methylimidazolium tetrafluoroborate: $[BMIM]^{+}[BF_{4}]^{-}$- was successfully applied for generating stable plasmas in the plasma-solution system. We successfully treated the film surface using the plasma-solution system and confirmed various oxygen-containing functional groups formed on the surface of PP film. The surface free energy of PP film was increased with increasing plasma treatment time and power. It also showed a maximum value at the PP sample treated in the ionic liquid solution of 1.5 M. ATR-FTIR analyses revealed the increase of various carbonyl groups(1,726 $cm^{-1}$, 1,643 $cm^{-1}$) and OH groups$(3,100{\sim}3,500\;cm^{-1})$ after plasma treatment of PP film, and XPS also supported the ATR-FTIR result.

New FTIR-ATR method (Peak combination method) for 3-dimensional orientation of PTT polymers (새로운 FTIR-ATR 방법(Peak combination method)을 이용한 PTT 분자사슬의 3차원 배향 분석)

  • 박기호;이한섭
    • Proceedings of the Korean Fiber Society Conference
    • /
    • 2003.04a
    • /
    • pp.339-340
    • /
    • 2003
  • 섬유 고분자 물질의 물리적 성질은 물질의 화학적 구조뿐만 아니라 분자의 배향과 결정화도와 같은 내부 구조에 의해 크게 영향을 받는다. 적외선 분광법은 특정 segment의 배향과 conformation, 결정화도와 같은 내부 구조의 변화를 선택적으로 관찰할 수 있는 장점으로 인하여 섬유 고분자 물질의 연구에 널리 사용되고 있다. 특히 적외선 분광법의 한 방법인 ATR (Attenuated Total Reflection) 방법은 투과에 의한 방법으로는 관찰이 불가능한 fiber, fabric, coating, thick film과 같은 형태의 시료를 관찰 할 수 있는 특성이 있으며 무엇보다 가장 큰 장점은 시료의 Machine Direction (MD), Transverse Direction(TD), Normal Direction (ND)의 세 방향으로 필름의 3차원적 배향 분석이 가능하다는 점이다.$^{1)}$ (중략)

  • PDF

Conservation status assessment of archaeological bone from Fourier Transform Infrared Spectroscopy and histological Analysis (적외선 분광 분석과 조직 분석을 통한 출토 인골의 보존 상태 평가)

  • Lee, Jeongwon;Kim, Sue Hoon;Kim, Yun-Ji;Cho, Eun Min;Kang, Soyeong
    • 보존과학연구
    • /
    • s.35
    • /
    • pp.87-98
    • /
    • 2014
  • Fourier transform infrared spectroscopy(FTIR-ATR) was applied to chemical analysis for conservation status of 10 human bone remains from Joseon Dynasty. The result of crystallinity index (CI) is $4.25{\pm}0.78$, carbonate to carbonate ratio (C/C) is $0.91{\pm}0.04$ and cabonate content (C/P) is $0.19{\pm}0.06$. The higher histological index (HI) confirmed CI and C/P value was increased and C/C value was reduced. While C/C or C/P values analysis is possible. While DNA analysis can be extracted from the bone, C/C values are lower or C/P values are higher was found to the analysis is possible. Chemical assessment of FTIR and histological index consequence is expected to be applicable as a basis for comprehensive understanding of the conservation status excavated bones.

  • PDF