• Title/Summary/Keyword: ASES

Search Result 168, Processing Time 0.026 seconds

The Influence of Clinical Symptoms and Self-Efficacy on Function in Women With Osteoarthritis (골관절염 여성의 임상적 특성 및 자기효능감이 기능수행에 미치는 영향)

  • Jung, Kyong-Ah;Lee, Wan-Hee
    • Physical Therapy Korea
    • /
    • v.14 no.1
    • /
    • pp.55-63
    • /
    • 2007
  • This study was designed to examine the relationship between clinical symptoms, self-efficacy, and performance of women with osteoarthritis. It is a survey study of 60 women who were diagnosed as osteoarthritis and given medical treatments from September, 2005 to October, 2005 in hospital 'H' located in Yongin-si. For clinical symptoms, radiographs of the subjects' knees were taken and evaluated the pathology grade by the Kellgren-Lawrence grade. Pain and stiffness was measured by the measure of WOMAC (Western Ontario and McMaster Universities Osteoarthritis Index), and functional reach test was measured in order to examine balancing abilities. Self-efficacy was measured by a tool which has revised the ASES (Arthritis Self-Efficacy Scale), and performance was measured by recording the difficulty of the WOMAC measurements themselves, and the time taken for 20 m walking, going up and down 9 stairs, and 5 sit-down and stand-up repetitions. The resulting differences in the other variables according to performance and the relationship between performance with variables are the following. First, an increase in pain in women with osteoarthritis led to decreased functional ability. Second, an increase in stiffness in women with osteoarthritis led to a decrease in functional ability. Third, a decrease in balance in women with osteoarthritis led to a decrease in functional ability. Fourth, a decrease in self-efficacy in women with osteoarthritis led to a decrease in functional ability. Fifth, the variables for estimating the performance by self-report were pain and self-efficacy. The variables for estimating the performance by recording the time taken was balance and self-efficacy. As a result factors such as pain, balance and self-efficacy in women with osteoarthritis were closely related to performance. Based on the results, it seems that physical therapy programs to decrease pain and to increase the balance in women with osteoarthritis, and psychological approaches to increasing self-efficacy are needed. I hope that the results of this study will be useful data for clinical management and intervention for women with osteoarthritis.

  • PDF

The Anti-allergic Effects of Kum-Hwang-San on Acute Cutaneous Dise ases in Experimental Animal Models (實驗動物모델에서 金黃散의 急性 皮膚 疾患에 對한 抗알레르기 效果)

  • Lee, Kwan-soon;Kim, Jong-han;Hwang, Choong-yeon;Lim, Gyu-sang
    • The Journal of Korean Medicine Ophthalmology and Otolaryngology and Dermatology
    • /
    • v.11 no.1
    • /
    • pp.40-53
    • /
    • 1998
  • Mast cells play an important role in the pathophysiologlcal changes observed in acute cutaneous and inflammatory diseases In order to see whether Kum-Hwang-San has an influence on mast cell- mediated immediate cutaneous reactions, the author has undertaken an animal study. Ears of mice were treated with a compound 48/80 solution topically at 30 min after the cutaneous application of Kum-Hwang-San. At each point, an ear swelling response was measured with a digimatic thickness micrometer. Ear swelling response induced by compound 48/80 was significantly suppressed dose-dependently by Kum-Hwang-San 30 min before topical application as compared with that in nonapplicated control mice, and the value returned to normal levels by 120 min. Compound 48/80- induced mast cell degranulation by Kum-Hwang-San was also remarkably decreased in accordance with the suppression in ear swelling response. Kum-Hwang-San dose-dependently inhibited histamine release from the rat peritoneal mast cells activated by compound 48/80. Another way to test acute cutaneous reaction is to induce passive cutaneous anaphylactic reaction. Kum-Hwang-San significantly inhibited passive cutaneous anaphylactic reaction activated by anti-dinitrophenyl IgE on both topical application and intradermal injection. Kum-Hwang-San also inhibited histamine release from the rat peritoneal mast cells induced by anti-DNP IgE. This study provides evidence that Kum-Hwang-San will be beneficial in the treatment of acute cutaneous diseases.

  • PDF

Proximal Approach of Ultrasound-guided Suprascapular Nerve Block: Comparison with Subacromial Steroid Injection

  • Bae, Kyu Hwan;Kim, Han Hoon;Lim, Tae Kang
    • Clinics in Shoulder and Elbow
    • /
    • v.22 no.4
    • /
    • pp.210-215
    • /
    • 2019
  • Background: This study was undertaken to evaluate early clinical outcomes of ultrasound-guided suprascapular nerve block (SSNB) using a proximal approach, as compared with subacromial steroid injection (SA). Methods: This retrospective study included a consecutive series of 40 patients of SSNB and 20 patients receiving SA, from August 2017 to August 2018. The visual analogue scale (VAS), American Shoulder Elbow Surgeon's score (ASES), University of California, Los Angeles score (UCLA), the 36 health survey questionnaire mental component summary (SF36-MCS), physical component summary (PCS), and range of motion (forward elevation, external rotation, and internal rotation) were assessed for clinical evaluations. Results: Compared with the baseline, VAS, and ranges of motion in the SSNB group significantly improved at the 4-week follow-up (VAS scores improved from $6.7{\pm}1.6$ to $4.3{\pm}2.4$, p<0.001; all ranges of motion p<0.05), while other variables showed no statistically significant differences. All clinical variables were significantly improved in the SA group (p<0.05). However, all clinical scores at the 4-week follow-up showed no significant difference between groups. Conclusions: Ultrasound-guided SSNB using proximal approach provides significant pain relief at 4-weeks after treatment, with statistically significant difference when compared with SA, suggesting that SSNB using proximal approach is a potentially useful option in managing shoulder pain. However, in the current study, it was less effective in improving shoulder function and health-related quality of life, compared with SA.

A modified method of augmented distal clavicle fracture osteosynthesis with a Fibertape coracoclavicular cerclage

  • Wu, ChengHan;Teo, Timothy Wei Wen;Wee, Andy Teck Huat;Toon, Dong Hao
    • Clinics in Shoulder and Elbow
    • /
    • v.25 no.3
    • /
    • pp.230-235
    • /
    • 2022
  • Background: Unstable distal clavicles experience high non-union rates, prompting surgeons to recommend surgery for more predictable outcomes. There is a lack of consensus on the optimal method of surgical fixation, with an array of techniques described in the literature. We describe an alternative method of fixation involving the use of a distal clavicular anatomical locking plate with Fibertape cerclage augmentation in our series of patients. Methods: Nine patients (8 males and 1 female), with a mean age of 36 years, who sustained unstable fracture of the distal clavicle in our institution were treated with our described technique. Postoperative range of motion, functional and pain scores, and time to radiographic union were measured over a mean follow-up period of 10 months. Incidences of postoperative complications were also recorded. Results: At the last patient consult, the mean visual analog scale score was 0.88±0.35, with a mean Disabilities of the Arm, Shoulder, and Hand (DASH) score of 1.46±0.87 and American Shoulder and Elbow Surgeons (ASES) score of 94.1±3.57. The mean range of motion achieved was forward flexion at 173°±10.6°, abduction at 173°±10.6°, and external rotation at 74.4°±10.5°. All patients achieved internal rotation at a vertebral height of at least L2 with radiographical union at a mean of 10 weeks. No removal of implants was required. Conclusions: Our described technique of augmented fixation of the distal clavicle is effective, produces good clinical outcomes, and has minimal complications.

Arthroscopic Treatment of Metallic Suture Anchor Failures after Bankart Repair (Bankart 수술 후 발생한 금속 봉합 나사못 합병증의 관절경적 치료)

  • Shin, Sang-Jin;Jung, Jae-Hoon;Kim, Sung-Jae;Yoo, Jae-Doo
    • Journal of the Korean Arthroscopy Society
    • /
    • v.10 no.1
    • /
    • pp.70-76
    • /
    • 2006
  • Purpose: This study presents 5 patients who had metallic anchor protrusion on glenoid after Bankart repair in anterior shoulder instability and reviewed the cause, clinical feature and arthroscopic removal technique. Method and Materials: 5 male with average age of 22 years (range 19 to 25 years) were included. 4 patients had arthroscopic Bankart repair and 1 patient had open repair for anterior shoulder instability. They had protruded metallic suture anchors on glenoid and the protruded suture anchors were removed arthroscopically using larger suture anchor empty inserter. Results: 4 patients had painful clicking sound with motion of abduction and external rotation and 1 patient showed shoulder instability. The ROM showed normal except mild degrees loss of external rotation. The position of protruded metallic anchor was 2, 3 and 5 O'clock in three patients and 4 O'clock in 2 patients. In 2 patients, the metallic suture anchor was malpositioned about 5mm off on the medial side from the anterior glenoid edge. All had Outerbrige classification Grade II-III chondral damage on humeral head and 1 patient showed glenoid cartilage destruction. None had shoulder instability after 2 years of follow-up. Constant score was 65 preoperatively and 89 postoperatively. ASES score was 67 preoperatively and 88 postoperatively. Conclusion: Symptoms of protruded suture anchor are not combined with instability. Most of symptoms were revealed from the rehabilitation period and confused with postoperative pain. Prompt diagnosis and early arthroscopic removal or impaction of protruded metallic suture anchor is recommended because of serious glenohumeral cartilage destruction. This is easy and simple and reproducible method to remove protruded metallic suture anchor arthroscopically.

  • PDF

Extracorporeal Shock-wave Therapy after Multiple Drilling as a Treatment for Chronic Calcific Tendinitis - An Analysis of Outcome Following Different Levels of Energy (만성 석회화 건염에 대한 다발성 천공술 후 추가적으로 시행한 체외 충격파 치료의 에너지 수준에 따른 결과분석)

  • Noh, Gyu Cheol;Jang, Keun Jong
    • The Journal of Korean Orthopaedic Ultrasound Society
    • /
    • v.5 no.2
    • /
    • pp.66-74
    • /
    • 2012
  • Purpose: To compare the outcome of two methods of chronic calcific tendinitis (CCT) treatment, Multiple drilling alone versus combined drilling and extracorporeal shock-wave therapy (ESWT). Furthermore, to analyze the clinical and radiologic results of different energy level configurations of ESWT. Materials and Methods: Among the patients complaining shoulder pain who visited the clinic from June 2010 to August 2011, 98 were diagnosed with CCT of the supraspinatus and were divided into the following three groups. Multiple drilling alone (n=31), Multiple drilling followed by high-energy ESWT (n=31), Multiple drilling followed by low-energy ESWT (n=36). The study was conducted only with patients with chronic pain persisting longer than six months despite prolonged conservative therapy. Clinical evaluation was done before and after 12 weeks from treatment, in clinical terms using the ASES, KSS, CSS system reflecting performance and symptom improvement, and in radiologic terms by studying the change in size of the calcific nodules. Results: All of three groups showed effects for improvement of clinical function and decrease of calcification and clinical improvement was significantly high in comparison between the group fulfilled by only multiple needling (the third group) and the group fulfilled by additional ESWT (the first and second groups) and in the radiological evaluation, calcification size and the rate of calcification decrease showed significant improvement statistically. For the comparison among the groups, degree of clinical function improvement and rate of calcification decrease showed significant difference between high energy group (the first group) and multiple needling group (the third group) as well as low energy group (the second group) and multiple needling group (the third group). But, in comparison between high energy group (the first group) and low energy group (the second group), there was no significant difference for the degree of clinical function improvement and rate of calcification decrease. Conclusion: For the treatment of chronic calcific tendinitis, additional ESWT showed more superior effects on clinical function improvement and radiological improvement regardless of the energy standard rather than the exclusive fulfillment of needling. But, as the result of ESWT by the energy standard, there was no significant difference for the decrease of calcification and degree of clinical function improvement.

  • PDF

The results of arthroscopic repair according to the delamination of rotator cuff (회전근 개 판분리 파열에 따른 관절경하 회전근 개 봉합술의 결과)

  • Ku, Jung Hoei;Cho, Hyung Lae;Park, Man Jun;Kim, Jeong Cheol
    • Journal of Korean Orthopaedic Sports Medicine
    • /
    • v.10 no.2
    • /
    • pp.61-68
    • /
    • 2011
  • Purpose: We evaluated the clinical outcome after arthroscopic repair in full thickness rotator cuff tears with and without delamination. Materials and Methods: From March 2006 to October 2008, we included 48 consecutive shoulders (31 males, 17 females; mean age 57.6 years; 45~68) who had arthroscopic double row repair for fullthickness tears of the rotator cuff. Mean rotator cuff tear size was 2.8 cm (range: 1.2~3.6) and the techniques of tendon-to-bone fixation varied according to the presence of delamination; separate row fixations of bursal and articular layer were used in delaminated tear. The mean follow-up was 26 months (range: 18~33) and functional and structural results were evaluated by American Shoulder and Elbow Surgeons (ASES), University of California at Los Angeles (UCLA) scale, isokinetic strength testing and magnetic resonance imaging (MRI) obtained mean 8 months (range:6~13) postoperatively. The patterns of delamination, age, sex, symptom duration, size of tear, satisfaction rate, retear rate ware compared and significance was set at p values < 0.05. Results: Postoperative functional shoulder score improved significantly in 44 shoulders (91.7%). Delamination was observed in 15 shoulders (31%) and it extended proximally and posteriorly in the majority of shoulders, and the articular layer was thicker (8/15, 53%) and more retracted (9/15, 60%) compared with the superficial bursal layer. Final follow up functional shoulder scores showed no differences between non-delaminated and delaminated tears and the presence of delamination had no correlations with sex, symptom duration, tear size and satisfaction rate, however, older age had more delaminated tears (p=0.041). Follow up MRI in 29 shoulders revealed that fourteen (48%) shoulders had complete healing; nine (31%), partial healing; six (21%), complete retear but the half of the retear group showed favorable clinical results. 79% (15/19) in non-delaminated tear and 80% (8/10) in delaminated tear were judged as healed tendon on MRI and double-layer double row repairs in delaminated tears resulted in nearly same rate of structural integrity of single-layer double row repairs (p=0.165). Conclusion: The incidence of delamination in our series was 31% and older age had more delaminated tears. Sex, symptom duration, preoperative size of the tear, functional results and satisfaction rate had no significant correlations with the presence of delamination. Nearly the same postoperative structural integrity was noted in both delaminated and non-delaminated tears.

  • PDF

The Preliminarily Result of Radiologic Disappearance of the Calcific Material on One Time Ultrasonographic Assisted Needling (견관절의 석회화 건염에서 초음파 유도하 1회 주사요법에 의한 방사선학적 조기 소멸 정도에 대한 예비보고)

  • Yoo, Jae-Chul;Shon, Min-Soo;Koh, Kyoung-Hwan;Lim, Tae-Kang;Lee, Yeong-Seok
    • The Journal of Korean Orthopaedic Ultrasound Society
    • /
    • v.5 no.1
    • /
    • pp.1-8
    • /
    • 2012
  • Purpose: The purpose of this study is to report the preliminarily result of the radiologic disappearance of the calcific material, regardless of the size, type or location, on one-time ultrasonographic (US) assisted needling for calcific tendinitis of the shoulder. Materials and Methods: From March to August 2011, 46 patients (47 shoulders) with symptomatic calcific tendinitis were treated by one-time US assisted needling. Initially, a diagnostic US was performed with patient to determine the locations, numbers and sizes of calcific deposits. After 1% lidocaine local anesthesia, the calcific material was punctured with an 18-gauge needle under US monitoring. If no calcific material was aspirated after 2 or 3 additional attempts, the deposits was performed multiple puncture to achieve decompression. And then all patients were performed subacromial corticosteroid injection. All patients were followed up 4 weeks after procedure. To assess the radiologic disappearance after one-time US assisted needling, simple radiographs of the treated shoulder were performed and size, dense, and morphology of the calcific deposits were compared with those in baseline radiographs. For clinical evaluations, visual analogue scale for pain and function (PVAS and FVAS), and American Shoulder and Elbow Surgeons (ASES) score were assessed. Results: There were 11 male and 35 female patients with the mean age of 53.8 years (28-71). The morphology of the calcific deposits were 31 type A and 16 type B by French Arthroscopic Society classification and mean size was $2.9{\pm}6.7$ mm before the procedure. At 4 weeks after the index procedure, the radiographic unchanged group was included in 10 cases and changed group was 37 cases. No intergroup difference for the clinical results after the procedure was evident, but group FAS classification before the procedure was significantly different (p=0.011). Conclusion: At 4 weeks after one-time US assisted needling for calcific tendinitis of the shoulder, the radiographic size- or dense-changed cases were showed in 79%, regardless of the size, type or location of the calcific material. But the radiographic nearly or complete disappearance were showed in only 21%.

  • PDF

The Results of Arthroscopic Double-Row Rotator Cuff Repairs with Combined Knot-tying and Knotless Suture Anchors (매듭 결속과 비매듭 봉합나사를 이용한 관절경적 이열 회전근개 봉합술의 결과)

  • Ku, Jung-Hoei;Lee, Choon-Key;Cho, Hyung-Lae;Choi, Seung-Hyun
    • Journal of the Korean Arthroscopy Society
    • /
    • v.12 no.3
    • /
    • pp.172-179
    • /
    • 2008
  • Purpose: To evaluate the functional and structural results of arthroscopic double-row repair using combined knot-tying and knotless suture anchors in rotator cuff tears. Materials and Methods: From March 2006 to June 2007, twenty-one patients (15 males, 6 females; mean age 55.6 years; range 48 to 67) were included who underwent arthroscopic double-row repair for full-thickness tears of the rotator cuff following conservative treatment for a mean of 6.5 months (range 3 to 11). The tear size was carefully inspected arthroscopically and we found 2 small, 13 medium and 6 large-sized rotator cuff tears, with a mean tear size of 2.5cm(range 1.8 to 3.2). The repair constructs were consisted of horizontal mattress sutures using conventional knot-tying suture anchors medially and simple suture at the same level of medial row stitch with Bioknotless RC anchors (DePuy Mitek, Norwood, MA) as lateral row. Clinical and functional evaluations were made according to the range of motion, the ASES, UCLA scale and the isokinetic strength testing. Postoperative cuff integrity was determined through magnetic resonance imaging. The mean follow-up was 15 months (range 13 to 24). Results: The average clinical outcome scores and strength were all improved significantly at the time of the final follow-up (p < 0.01). Nineteen patients (90%) were satisfied with the result of the treatment. In 17 of 21 patients (81%) were judged to reveal healed tendon on magnetic resonance imaging at a mean of 7 months postoperatively. There were no significant functional differences according to the preoperative tear size (p<0.01), but large-sized tear shows less favorable structural results in 3 out of 6 cases(50%). Conclusion: Our results document the usefulness and variability of arthroscopic double-row rotator cuff repairs comparable to the results of the other types of double-row repairs.

  • PDF

The Use of Arthroscopic UU Stich for Rotator Cuff Tear and Clinical Results (회전근 개 파열의 관절경하 봉합에서 새로운 봉합 방법의 이용)

  • Ko, Sang-Hun;Shin, Seung-Myeong;Choi, Young-Jin;Cha, Jae-Ryong;Park, Han-Chang
    • Clinics in Shoulder and Elbow
    • /
    • v.14 no.1
    • /
    • pp.67-72
    • /
    • 2011
  • Purpose: There are various known methods for arthroscopic rotator cuff repair. The purpose of this retrospective study is to report on the clinical results and anatomical results of UU repair surgery, which is a new repair method. Materials and Methods: We enrolled 156 patients (88 men and 68 women) who underwent UU repair for rotator cuff tears from January 2009 to May 2010 in our hospital. Their average age was 55 years old (range: 38~75 years old) and the average follow-up period was 12 months (range: 6~23 months). For determining the results, we evaluated the VAS for pain, the daily living index (ADL) in the ASES scores, the UCLA and KSS scores, and all these tests were conducted at the first hospital visit and 6 months and 1 year after surgery and at the final follow-up. During the follow-up period, MRI was performed 3 and 6 months after surgery only in the patients who consented to MRI scans to confirm the presence of re-rupture. Results: The average scores of the VAS as a pain indicator decreased from 7.0 before surgery to 2.7 after surgery (p<0.05). The UCLA and KSS scores increased from 22.2 to 32.5 and from 83.7 to 91.5, and the changes was significant (p<0.05). For the active joint range of motion, the average forward flexion was improved from 125 to 175 degrees, the average lateral external rotation was improved from 38 to 58 degrees, and the average abduction was improved from 104 to 169 degrees. Out of a total of 156 patients, re-rupture was observed in 4 cases (3%) of 117 cases (75%) for which MRI was performed (with consent) between 3 and 6 months after surgery. Conclusion: UU repair surgery as arthroscopic repair of rotator cuff tear is a good repair method that shows excellent clinical results and a low re-rupture rate.