• Title/Summary/Keyword: ARCH EFFECT

Search Result 365, Processing Time 0.024 seconds

Effect of the Arch Support on the Strength of the Abductor Hallucis During the Toe Spread Out Exercise in Standing Position in Individuals With Pes Planus

  • Jeon, In-cheol;Kim, Ki-song
    • Physical Therapy Korea
    • /
    • v.27 no.3
    • /
    • pp.206-211
    • /
    • 2020
  • Background: The longitudinal arch is important for individuals with pes planus. The toe spread out exercise (TSO) has been widely used to continuously support the longitudinal arch by increasing the abductor hallucis (AbdH) muscle activation. However, the AbdH muscle is commonly lack of the sufficient activation during the TSO especially in individuals with pes planus. Objects: This study was performed to investigate the effect of arch support on the muscle activity and strength of the AbdH during TSO in standing position in individuals with pes planus. Methods: Twenty subjects with pes planus between 20 and 30 years of age participated in this study. The muscle activity and strength of the AbdH were measured using surface EMG system and the Smart KEMA tensiometer system. The AbdH muscle was evaluated during TSO between individuals with and without longitudinal arch support in standing position. The longitudinal arch was supported by using the insole. The paired t-test was used. The level of statistical significance was set at α = 0.05. Results: The muscle activity and strength of the AbdH during TSO with arch support in standing position was significantly greater than that without arch support. Conclusion: The muscle activity and strength of the AbdH during TSO in standing position can be influenced by the longitudinal arch support in individuals with pes planus. The AbdH strengthening during TSO in standing with arch support can be recommended especially in individuals with pes planus in the clinical settings.

Determination of the restoration effect on the structural behavior of masonry arch bridges

  • Altunisik, A.C.;Bayraktar, A.;Genc, A.F.
    • Smart Structures and Systems
    • /
    • v.16 no.1
    • /
    • pp.101-139
    • /
    • 2015
  • In this paper, it is aimed to investigate the restoration effect on the structural behavior of masonry arch bridges. Dandalaz masonry arch bridge located on the 4km east of Karacasu town of Aydin, Turkey is selected as a numerical example. The construction year of the bridge is not fully known, but the bridge is dated back to 15th century. Considering the current situation, it can be easily seen that the structural elements such as arch, side walls and timber blocks are heavily damaged and the bridge is unserviceable. Firstly finite element model of the bridge is constituted to reflect the current situation (before restoration) using building survey drawings. After, restoration project is explained and finite element model is reconstituted (after restoration). The structural responses of the bridge are obtained before and after restoration under dead load, live load and dynamic earthquake loads. For both conditions, maximum displacements, maximum-minimum principal stresses and maximum-minimum elastic strains are given with detail using contours diagrams and compared with each other to determine the restoration effect. From the study, it can be seen that the maximum internal forces are consisted under dynamic loads before and after restoration. Also, the restoration projects and studies have important and positive effects on the structural response of the bridge to transfer these structures to future.

Case study on stability performance of asymmetric steel arch bridge with inclined arch ribs

  • Hu, Xinke;Xie, Xu;Tang, Zhanzhan;Shen, Yonggang;Wu, Pu;Song, Lianfeng
    • Steel and Composite Structures
    • /
    • v.18 no.1
    • /
    • pp.273-288
    • /
    • 2015
  • As one of the most common failure types of arch bridges, stability is one of the critical aspects for the design of arch bridges. Using 3D finite element model in ABAQUS, this paper has studied the stability performance of an arch bridge with inclined arch ribs and hangers, and the analysis also took the effects of geometrical and material nonlinearity into account. The impact of local buckling and residual stress of steel plates on global stability and the applicability of fiber model in stability analysis for steel arch bridges were also investigated. The results demonstrate an excellent stability of the arch bridge because of the transverse constraint provided by transversely-inclined hangers. The distortion of cross section, local buckling and residual stress of ribs has an insignificant effect on the stability of the structure, and the accurate ultimate strength may be obtained from a fiber model analysis. This study also shows that the yielding of the arch ribs has a significant impact on the ultimate capacity of the structure, and the bearing capacity may also be approximately estimated by the initial yield strength of the arch rib.

Effect of the volumetric dimensions of a complete arch on the accuracy of scanners

  • Kim, Min-Kyu;Son, KeunBaDa;Yu, Beom-Young;Lee, Kyu-Bok
    • The Journal of Advanced Prosthodontics
    • /
    • v.12 no.6
    • /
    • pp.361-368
    • /
    • 2020
  • PURPOSE. The present study aimed to evaluate the accuracy of a desktop scanner and intraoral scanners based on the volumetric dimensions of a complete arch. MATERIALS AND METHODS. Seven reference models were fabricated based on the volumetric dimensions of complete arch (70%, 80%, 90%, 100%, 110%, 120%, and 130%). The reference models were digitized using an industrial scanner (Solutionix C500; MEDIT) for the fabrication of a computer-aided design (CAD) reference model (CRM). The reference models were digitized using three intraoral scanners (CS3600, Trios3, and i500) and one desktop scanner (E1) to fabricate a CAD test model (CTM). CRM and CTM were then superimposed using inspection software, and 3D analysis was conducted. For statistical analysis, one-way analysis of variance was used to verify the difference in accuracy based on the volumetric dimensions of the complete arch and the accuracy based on the scanners, and the differences among the groups were analyzed using the Tukey HSD test as a post-hoc test (α=.05). RESULTS. The three different scanners showed a significant difference in accuracy based on the volumetric dimensions of the complete arch (P<.05), but the desktop scanner did not show a significant difference in accuracy based on the volumetric dimensions of the complete arch (P=.808). CONCLUSION. The accuracy of the intraoral scanners was dependent on the volumetric dimensions of the complete arch, but the volumetric dimensions of the complete arch had no effect on the accuracy of the desktop scanner. Additionally, depending on the type of intraoral scanners, the accuracy differed according to the volumetric dimensions of the complete arch.

Effect of Active Foot Arch Support on Lower Extremity Electromyographic Activity during Squat Exercise in Persons with Pronated Foot (회내족 대상자의 스쿼트 동안 능동적 족궁 지지가 하지근육의 근전도 활성도에 미치는 영향)

  • Nam, Ki-Seok;Park, Ji-Won
    • The Journal of Korean Physical Therapy
    • /
    • v.22 no.5
    • /
    • pp.57-61
    • /
    • 2010
  • Purpose: The purpose of this study was to identify the effect of active foot arch support on the muscles of lower extremity electromyographic activity during squat exercise in persons with pronated foot. Methods: The study subjects were 16 persons with pronated foot. They have no history of surgery in lower extremity and trunk and limitation of range of motion or pain when performing squat exercise. Each subject was measured the navicular drop (ND) to determine the pronated foot. And then the subjects were asked to perform three repetitions of a $90^{\circ}$ knee flexion squat in both conditions which are 1) preferred squat and 2) squat with active foot arch support. Results: Paired t-test revealed that squat with active foot arch support produced significantly greater EMG activities in abductor hallucis (p=0.00), proneus longus (p=0.03) and gluteus medius (p=0.04) than preferred squat. But the EMG activities of tibialis anterior, vastus medialis oblique and vastus lateralis were not showed significantly different between the both squat conditions. Conclusion: The findings of this study suggest that active foot arch support during squat increase the activities of lower extremity muscles which are the abductor hallucis, proneus longus and gluteus medius. Also, the abductor hallucis which is one of the planter intrinsic muscle and peroneus longus play a role in support of the foot arch and active foot arch support induced the increase of the activity of gluteus medius. Therefore active foot arch support can change the lower extremity biomechanics as well as passive foot support such as foot orthotics and taping.

A Study on the Effect of Arch Support for Improvement of Muscle Activity (운동효과 증진을 위한 Arch Support 효과에 관한 연구)

  • Lee, Chang-Min;Kim, Jin-Hoon;Oh, Yeon-Ju;Kim, Dae-Woong
    • Journal of the Ergonomics Society of Korea
    • /
    • v.27 no.3
    • /
    • pp.71-79
    • /
    • 2008
  • Walking shoes for walking and jogging have been used to enjoy lots of leisure time. Functional shoes such as walking shoes have special functions to improve body motility by changing of shoe shapes. The walking shoes could improve the motility by structural transformation of outsole as increase degrees of heel and toe. The study on insoles has not been conducted enough on the contrary of the study of outsole. The purpose of this study is to perform ergonomics analysis whether the Arch Supported insoles have an improving effect of muscle activities or not. Experiments were performed with 6 subjects who are health and haven't experienced any diseases past. EMG(Electromyography) and Foot Pressures were measured repeatedly for 5 seconds at 0 hour, after 1 hour and after 2 hours of walking. Insoles used for experiment are normal insole, insole inserted Arch Support and pad. The electrodes for EMG measurement were set on waist (erector spinae), and thigh (vastus lateralis), calf (gastrocnemius). Evaluations of EMG were analyzed by shift of MF (Median Frequency) and MPF (Mean Power Frequency). Foot Pressure was analyzed by mean pressure of feet and change of walking time. As results, Arch Support insole had larger frequency shift value than that of normal insole. Frequency shift between Arch Support insoles and normal insole showed significant difference on 95% confidence interval. And insole 1 has the highest value of frequency shift. For results of foot pressure, Arch Support insoles show continuous decreasing tendency when comparing with normal insoles by changing of times. Also, insole 1 has the highest decreasing value of foot pressure. Therefore, this study presented that the Arch Support insole can promote muscle activities and improves comfort for a prolonged walking.

Assessment of Visual Characteristics on Arch Bridge Using Landscape Simulation (경관시뮬레이션을 이용한 아치교량의 시각적 특성평가)

  • Jung, Sung-Gwan;Park, Young-Eun;Park, Kyung-Hun;You, Ju-Han;Kim, Kyung-Tae;Lee, Woo-Sung
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.35 no.4
    • /
    • pp.48-56
    • /
    • 2007
  • This study was to understand the component that affects the formative beauty and to present the direction of bridge design for improving the image of urban landscape to survey the visual effect and landscape Preference by the change of bridge type. The results of this study are as follows. In the results of image analysis by bridge types, the images of one-arch bridges are unique and interesting, whereas more than two successive arched bridge were harmonize, stable, consecutive and regular. In the case of the arch rib, braced-rib arch bridge was assessed that complicated, diverse and interesting more than solid-rib arch bridge. The results of factor analysis on the psychological factor were classified into three categories: orderliness, aesthetic and symbolism. In the results of analysis on psychological factors by bridge types, the orderliness and symbolism were different in the position of path, and the number of arches, too. In case of arch rib, symbolism was different. In the preference analysis, they showed a sensitive reaction in the background of building. In the results of the relativity preference and psychological factor, according to aesthetic, symbolism and orderliness, there was an effect on the background of building. And, there showed the high effect in order of aesthetic, orderliness and symbolism in the background of mountain and building. This study should be objective raw data of the arch bridge design for improving the urban landscape. In the future, aesthetic variables like colors or textures should be considered for more exact evaluation.

Study on bearing capacity of combined confined concrete arch in large-section tunnel

  • Jiang Bei;Xu Shuo;Wang Qi;Xin Zhong Xin;Wei Hua Yong;Ma Feng Lin
    • Steel and Composite Structures
    • /
    • v.51 no.2
    • /
    • pp.117-126
    • /
    • 2024
  • There are many challenges in the construction of large-section tunnels, such as extremely soft rock and fractured zones. In order to solve these problems, the confined concrete support technology is proposed to control the surrounding rocks. The large-scale laboratory test is carried out to clarify mechanical behaviours of the combined confined concrete and traditional I-steel arches. The test results show that the bearing capacity of combined confined concrete arch is 3217.5 kN, which is 3.12 times that of the combined I-steel arch. The optimum design method is proposed to select reasonable design parameters for confined concrete arch. The parametric finite element (FE) analysis is carried out to study the effect of the design factors via optimum design method. The steel pipe wall thickness and the longitudinal connection ring spacing have a significant effect on the bearing capacity of the combined confined concrete arch. Based on the above research, the confined concrete support technology is applied on site. The field monitoring results shows that the arch has an excellent control effect on the surrounding rock deformation. The results of this research provide a reference for the support design of surrounding rocks in large-section tunnels.

Effect of different arch widths on the accuracy of three intraoral scanners

  • Kaewbuasa, Narin;Ongthiemsak, Chakree
    • The Journal of Advanced Prosthodontics
    • /
    • v.13 no.4
    • /
    • pp.205-215
    • /
    • 2021
  • PURPOSE. The purpose of this study was to compare the accuracy of three intraoral scanner (IOS) systems with three different dental arch widths. MATERIALS AND METHODS. Three dental models with different intermolar widths (small, medium, and large) were attached to metal bars of different lengths (30, 40, and 50 mm). The bars were measured with a coordinate measuring machine and used as references. Three IOSs were compared: TRIOS 3 (TRI), True Definition (TD), and Dental Wings (DW). The relative length and angular deviation of both ends of the metal bars from the scan data set (n = 15) were calculated and analyzed. RESULTS. Comparing among scanners in terms of trueness, the relative length deviation of DW in the small (1.28%) and medium (1.08%) arches were significantly higher than TRI (0.46% and 0.48%) and TD (0.33% and 0.18%). The angular deviation of DW in the small (1.75°) and medium (1.83°) arches were also significantly greater than TRI (0.63° and 0.40°) and TD (0.55° and 0.89°). Comparing within scanner, the large arch of DW showed better accuracy than other arch sizes (P < .05). On the other hand, the larger arch of TD presented a greater tendency of angular deviation in terms of trueness. No significant differences were found in terms of trueness between the arch widths of TRI group. CONCLUSION. The different widths of the dental arches can affect the accuracy of some intraoral scanners in full arch scan.

Impact effect analysis for hangers of half-through arch bridge by vehicle-bridge coupling

  • Shao, Yuan;Sun, Zong-Guang;Chen, Yi-Fei;Li, Huan-Lan
    • Structural Monitoring and Maintenance
    • /
    • v.2 no.1
    • /
    • pp.65-75
    • /
    • 2015
  • Among the destruction instances of half-through arch bridges, the shorter hangers are more likely to be ruined. For a thorough investigation of the hanger system durability, we have studied vehicle impact effect on hangers with vehicle-bridge coupling method for a half-through concrete-filled-steel-tube arch bridge. A numerical method has been applied to simulate the variation of dynamic internal force (stress) in hangers under different vehicle speeds and road surface roughness. The characteristics and differences in impact effect among hangers with different length (position) are compared. The impact effect is further analyzed comprehensively based on the vehicle speed distribution model. Our results show that the dynamic internal force induced by moving vehicles inside the shorter hangers is significantly greater than that inside the longer ones. The largest difference of dynamic internal force among the hangers could be as high as 28%. Our results well explained a common phenomenon in several hanger damage accidents occurred in China. This work forms a basis for hanger system's fatigue analysis and service life evaluation. It also provides a reference to the design, management, maintenance, monitoring, and evaluation for this kind of bridge.