• Title/Summary/Keyword: APDC

Search Result 27, Processing Time 0.032 seconds

Organic Precipitate Flotation of Trace Metallic Elements with Ammonium Pyrrolidinedithiocarbamate (II). Application of Solvent Sublation for Determination of Trace Cd, Co, Cu and Ni in Water Samples

  • 김영상;정용준;최희선
    • Bulletin of the Korean Chemical Society
    • /
    • v.19 no.1
    • /
    • pp.50-56
    • /
    • 1998
  • A solvent sublation was studied for the determination of trace Cd, Co, Cu and Ni in water samples. Ammonium pyrrolidine dithiocarbamate (APDC) was used as a complexing agent. Experimental conditions such as pH of solution, amounts of APDC, the type and amount of surfactant, the type of solvent, etc. were optimized for the effective sublation of analytes. After metal-PDC complexes were formed in sample solutions of pH 2.5, the precipitate-type complexes were floated in a flotation cell with an aid of sodium lauryl sulfate as a surfactant and by bubbling with nitrogen gas. The precipitates were dissolved and separated into the surface layer of methyl iso-butyl ketone (MIBK). The analytes preconcentrated were determined by a graphite furnace atomic absorption spectrophotometry (GF-AAS). Extractability of each element was 88% for Cd(Ⅱ), 86% for Co(Ⅱ), 95% for Cu(Ⅱ) and 76% for Ni(Ⅱ), respectively. And this procedure was applied to the analysis of real samples. From the recoveries of more than 92%, it was concluded that this method could be simple and applicable for the determination of trace elements in various water samples of a large volume.

Spectrophotometric Determination of Nickel (Ⅱ) in Tween80 Micellar Medium (Tween80 미셀 용액에서 Ni(Ⅱ)의 분광광도법 정량)

  • Lee, Seung-Kwon;Choi, Hee-Seon
    • Journal of the Korean Chemical Society
    • /
    • v.44 no.3
    • /
    • pp.207-211
    • /
    • 2000
  • We have studied on the determination of Ni(II) using APDC as a complexing agent in Tween80 micellar medium. The absorption spectrum of Ni(PDC)$_2$ complex in Tween80 medium was better defined and more sensitive than that in chloroform Ni(PDC)$_2$ complex was very stable at pH 7.0 and up to 100 minutes, and could be quantitatively chelated when APDC was added to over 10 times moles of Ni(II). The optimum concentration of Tween80 was 0.1%. The calibration curve of Ni(PDC)$_2$ complex with good linearity(R$^2$=0.9955) was obtained in 0.1% Tween80 medium. The detection limit and the determination limit were 0.09 ${\mu}g$/mL and 0.28 ${\mu}g$/mL, respectively. This technique was applied to the analysis of Suwon stream water samples, and about l00% of recoveries were obtained from the spiked samples. Although the formation of Ni(PDC)$_2$ complex was interfered by various metal ions, this technique could be applied to the practical determination of Ni(II).

  • PDF

Studies on Partition and Extraction Equilibria of Metal-Dithiocarbamate Complexes(II). Metal Complexes of Ammonium Pyrrolidine Dithiocarbamate (Dithiocarbamate 금속착물의 분배 및 추출평형(제2보). Ammonium Pyrrolidine Dithiocarbamate의 금속착물)

  • Lee, Jong-Sun;Choi, Jong-Moon;Choi, Hee-Seon;Kim, Young-Sang
    • Analytical Science and Technology
    • /
    • v.8 no.3
    • /
    • pp.321-334
    • /
    • 1995
  • Basic studies for the effective extraction of ammonium pyrrolidine dithiocarbamate(APDC) complexes of Co(II), Ni(II) and Cu(II) into a solvent have been performed. The maximum distribution ratio was appeared (log D=1.3543) at pH 2.0 and the partition coefficient was 2.489 in the extraction of $4{\times}10^{-5}M$ APDC itself into chloroform. From the UV/visible spectra of metal-chelates in aqueous and organic solutions, the pH to form stable 1:2 metal-ligand complexes were Co(II):5.0, Ni(II):8.0 and Cu(II):8.0, respectively and only 1 minute was enough to be partitioned into the chloroform. Besides, the partition and extraction equilibria of the complexes were investigated by back-extracting $10.0{\mu}g/ml$ metal-chelates from the solvent into an aqueous solution beacuse of their slight solubilities in the aqueous solution. The distribution coefficients and extractabilities were as follows : at pH 6.5~8.5 of the aqueous solution, log D=2.834 : E(%)=99.9% for $Co(PDC)_2$, at pH 11, log D=5.699 E%=100 for $Ni( PDC)_2$, and at pH 6.0, log D=2.025 : E(%)=99.1% for $Cu(PDC)_2$. And the extraction and formation constants were log $K_{ex}=9.671$ : log ${\beta}_2=6.938$ for $Co(PDC)_2$, log $K_{ex}=9.646$ : log ${\beta}_2=7.071$ for $Ni( PDC)_2$, and log $K_{ex}=9.074$ : log ${\beta}_2=7.049$ for $Cu(PDC)_2$, respectively. From these results, an optimum extraction procedure can be constructed for the separative concentration of trace metallic ions, and the quantitative determination of them in advanced materials and environmental samples will be expected without any influence of sample matrixes.

  • PDF

Organic Precipitate Flotation of Trace Metallic Elements with Ammonium Pyrrolidinedithiocarbamate(Ⅰ). Determination of Bismuth, Cadmium, Cobalt and Lead in Water Samples by Coprecipitation-Flotation with Cu-pyrrolidinedithiocarbamate (Ammonium Pyrrolidinedithiocarbamate에 의한 극미량 금속원소의 유기침전 부선에 관한 연구(제1보) Cu-pyrrolidinedithiocarbamate 공침부선에 의한 물시료중 비스무트, 카드뮴, 코발트 및 납의 정량)

  • Jung, Yong June;Choi, Jong Moon;Choi, Hee Seon;Kim, Young Sang
    • Journal of the Korean Chemical Society
    • /
    • v.40 no.12
    • /
    • pp.724-732
    • /
    • 1996
  • The organic precipitate flotation using Cu(II)-pyrrolidinedithiocarbamate complex as a coprecipitant was studied for the preconcentration and determination of trace Cd, Pb, Bi and Co in several water samples. Experimental conditions such as pH of solution, amounts of Cu(II) and ammonium pyrrolidinedithiocarbamate(APDC), stirring time, the type and amount of surfactant, etc. were optimized for the effective flotation of analytes. After 3.0 mL of 1,000 ${\mu}g/mL$ Cu(II) solution was added to 1.00 L water sample, the pH of the solution was adjusted to 2.5 with HNO3 solution. Trace amounts of analytes were coprecipitated by adding 2.0% APDC solution. And the precipitates were flotated onto the surface of solution with the aid of nitrogen gas and sodium lauryl sulfate. The floats were collected from mother liquor, and filtered through the micropore glass filter by suction. The precipitates were dissolved with 4 mL conc. HNO3, and then diluted to 25.00 mL with deionized water. The analytes were determined by graphite furnace atomic absorption spectrophotometry. This flotation technique was applied to the analysis of some water samples, and the 90 to 120% of recoveries were obtained from the spiked samples, this procedure could be concluded to be simple and applicable for the trace element analysis in various kinds of water.

  • PDF

Spectrophotometric Determination of Cadmium and Copper with Ammonium Pyrrolodinedithiocarbamate in Nonionic Tween 80 Micellar Media

  • Lee, Seung Gwon;Choe, Hui Seon
    • Bulletin of the Korean Chemical Society
    • /
    • v.22 no.5
    • /
    • pp.463-466
    • /
    • 2001
  • The determination of Cd2+ and Cu2+ with ammonium pyrrolidinedithiocarbamate (APDC) in Tween 80 micellar media has been studied. The UV-visible spectrum of Cd(PDC)2 complex in Tween 80 media had more sensitivity tha n in chloroform. Although the UV-visible spectrum of the Cu(PDC)2 complex in Tween 80 media had somewhat less sensitivity than that in chloroform, absorbance data of Cu2+ were more reproducible in Tween 80 media. The Cd(PDC)2 and Cu(PDC)2 complexes were very stable at pH 7.0 for up to 100 minutes and could be quantitatively chelated if APDC were added to the sample solution more than 30 times the moles of Cd2+ and Cu2+ . The optimum concentration of Tween 80 was 0.1%. The calibration curves of Cd(PDC)2 and Cu(PDC)2 complexes with good linearity were obtained in 0.1% Tween 80 media. The detection limits of Cd2+ and Cu2+ were 0.0493 ㎍mL-1 and 0.0393 ㎍mL-1 , respectively. Recovery yields of Cd2+ and Cu2+ ions in the spiked real samples were almost 100%. Based on experimental results, this proposed method could be applied to the rapid and simple determination of Cd2+ and Cu2+ in real samples.

아시아태평양 구강보건 현황

  • The Korean Dental Association
    • The Journal of the Korean dental association
    • /
    • v.40 no.5 s.396
    • /
    • pp.364-372
    • /
    • 2002
  • 지난 4월 3일부터 7일까지 개최된 제24차 APDC 서울총회 및 제44회 치협 종합학술대회에서는 아태연맹 산하에 있는 여러 위원회의 심포지엄도 개최됐다. 그중에서도 각국의 대표가 참석한 교육위원회 (APDF Education Committee : 위원장 오노 교수-일본동경의 · 치대)가 열려 아시아 각국의 구강보건 증진 프로그램 심포지엄을 갖고 각국의 치의학 현황 및 구강보건에 대해 토의했다. 교육위원회에 참석한 신승철 단국치대 예방치과 교수가 당일 발표된 아세아 태평양 8개국의 구강보건에 대해 취합하여 정리한 내용을 게재한다.

  • PDF

Determination of Cadmium, Copper, Lead, Nickel, and Zinc in Sediments by ID-ICP/MS (동위원소희석 질량분석법에 의한 저니토 중의 카드뮴, 구리, 납, 니켈, 아연의 정량)

  • Cho, Kyung-Haeng;Park, Chang-Joon;Suh, Jung-Kee;Han, Myoung-Sub
    • Analytical Science and Technology
    • /
    • v.13 no.3
    • /
    • pp.297-303
    • /
    • 2000
  • Isotope-dilution inductively coupled plasma mass spectrometry was used to determine trace amounts of Cd, Cu, Pb, Ni and Zn in sediment. Sediment samples were dissolved by microwave digestion with addition of mixed acid ($HNO_3$, HF and $HClO_4$). Lead was determined after separation of alkaline and alkaline earth metals by an ammonium pyrrolidenedithiocarbarmate (APDC) solvent extraction. The other elements were determined after separation of iron, tin and titanium by hydroxide precipitation. Recovery efficiency of the analyte elements was not satisfactory, but most of matrix elements causing the isobaric interference could be effectively eliminated by the separation. Good agreement was achieved with the certified values in the analysis of the two sediment reference materials.

  • PDF

Determination Of Dissolved Trace Metals In Sea Water By Atomic Absorption Spectrophotometry After Concentration By Fe (III) - APDC Coprecipitation

  • Lee, Dong-Soo;Lee, Soo-Hyung;Kwak, Hi-Sang;Lee, Kwang Woo
    • 한국해양학회지
    • /
    • v.15 no.1
    • /
    • pp.66-70
    • /
    • 1980
  • A method for the determination of dissolved species of Cd, Co, Cu, Ni, Pb and Zn in sea water by flame atomic absorption spectrophotometry (AAS) is described. Prior to analysis by AAS, these elements are concentrated by coprecipitation with iron pyrrolidinedithiocarbamate at pH 3 because of matrix effects and their low concentration levels in sea water. The detection limits are 0.01, 0.04, 0.02, 0.05, 0.08, and 0.03$\mu\textrm{g}$/l, and the relative standard deviations are 1.0, 2.4, 1.3, 2.9, 2.0 and 2.9% for Cd, Co, Cu, Ni, Pb and Zn, respectively. The method is shown to be satisfactory in terms of recovery and precision for the determination of these metals in sea water.

  • PDF

Role of Peripheral Glutamate Receptors to Mechanical Hyperalgesia following Nerve Injury or Antidromic Stimulation of L5 Spinal Nerve in Rats with the Previous L5 Dorsal Rhizotomy (제5효후근을 절단한 백서에서 제5요척수신경의 신경손상이나 전기자극에 의한 기계적 과민통 생성에 있어서 말초 글루타민산 수용기의 역할)

  • Jang, Jun Ho;Nam, Taick Sang;Yoon, Duck Mi;Leem, Joong Woo;Paik, Gwang Se
    • The Korean Journal of Pain
    • /
    • v.19 no.1
    • /
    • pp.33-44
    • /
    • 2006
  • Background: Peripheral nerve injury leads to neuropathic pain, including mechanical hyperalgesia (MH). Nerve discharges produced by an injury to the primary afferents cause the release of glutamate from both central and peripheral terminals. While the role of centrally released glutamate in MH has been well studied, relatively little is known about its peripheral role. This study was carried out to determine if the peripherally conducting nerve impulses and peripheral glutamate receptors contribute to the generation of neuropathic pain. Methods: Rats that had previously received a left L5 dorsal rhizotomy were subjected to a spinal nerve lesion (SNL) or brief electrical stimulation (ES, 4 Hz pulses for 5 min) of the left L5 spinal nerve. The paw withdrawal threshold (PWT) to von Frey filaments was measured. The effects of an intraplantar (i.pl.) injection of a glutamate receptor (GluR) antagonist or agonist on the changes in the SNL- or ES-produced PWT was investigated. Results: SNL produced MH, as evidenced by decrease in the PWT, which lasted for more than 42 days. ES also produced MH lasting for 7 days. MK-801 (NMDAR antagonist), DL-AP3 (group-I mGluR antagonist), and APDC (group-II mGluR agonist) delayed the onset of MH when an i.pl. injection was given before SNL. The same application blocked the onset of ES-induced MH. NBQX (AMPA receptor antagonist) had no effect on either the SNL- or ES-induced onset of MH. When drugs were given after SNL or ES, MK-801 reversed the MH, whereas NBQX, DL-AP3, and APDC had no effect. Conclusions: Peripherally conducting impulses play an important role in the generation of neuropathic pain, which is mediated by the peripheral glutamate receptors.

Investigation on Harmful Trace Elements in Some Food Additives (식품첨가물중(食品添加物中) 유해미량금속(有害微量金屬) 함량(含量)에 관(關)하여)

  • Kirn, Jeung-Ok;Song, Jae-Chul;Young, Han-Chul;Ha, Yeung-Lae
    • Journal of Nutrition and Health
    • /
    • v.12 no.3
    • /
    • pp.25-32
    • /
    • 1979
  • In order to investigate harmful trace elements in ford additives used in food processing the contents of Copper, Lead, Cadmium, Chromium, Manganese, Nickel and Iron are determined by Atomic Absorption Spectrophotometer. These Elements are Extracted with APDC-MIBK extract method. Samples are collected from the food Industrial companies in Korea. Samples studied as shown in Table 1 are food colors(3-samples, Flavoring Agents(7-samples), Acidifiers(4-samples) Baking Powders(4-samples), Emulsifiers(2-samples), Thickeners(2-samples), Antioxidants(2-samples), Intensifiers(2-samples), Seasonings(3-samples), modifiers (10-samples) Most of the food additives contained comparatively a little small amount of harmful trace elements. However, the contents of harmful trace elements of Sodium Carbonate, Food Yellow No.5, Food Blue No.1, Food Red No.2 and Alkalies added in noodles are significantly higher than the other food additives. The obtained results are as follows ; 1) Sodium Carbonate contained Cadmium; 16.73 ug/g and Lead ; 61.55 ug/g. 2) Food Yellow No. 5 contained Cadmium: 1.67ug/g and Lead; 23.46 ug/g. 3) Food Blue No. 1 contained Cadmium; 1. 16 ug/g and Lead; 23.46 ug/g. 4) Food Red Ho. 1 contained Cadmium; 1.91 ug/g and Lead 23.08 ug./g. 5) Alkalies added in noodles contained Cadmium; 6. 11 ug/g and Lead; 53.85 ug/g.

  • PDF