• Title/Summary/Keyword: AO type-C fracture

Search Result 15, Processing Time 0.031 seconds

Results of Arthroscopic-assisted Minimally Invasive Removal of a Lateral Periarticular Plate used for the Treatment of AO Type-C Distal Femoral Fractures (AO C-형 원위 대퇴골 골절의 치료로 삽입된 관외측 금속판의 절경 보조하 최소 침습적 제거의 결과)

  • Kim, Young-Mo;Lee, June-Kyu;Yang, Jae-Hoon;Kim, Bo-Kun;Lee, Won-Gu
    • Journal of the Korean Arthroscopy Society
    • /
    • v.13 no.1
    • /
    • pp.46-52
    • /
    • 2009
  • Purpose: To evaluate the usefulness of minimally invasive arthroscopy-assisted plate removal of a laterally inserted periarticular distal femur plate used for the treatment of AO type-C distal femur fractures. Materials and Methods: From October 2002 to November 2005, we evaluated 17 patients whose plates were removed through minimally invasive arthroscopy-assisted plate-removal technique and 15 patients who got their plates removed through conventional method without using arthroscopy, 32 patients in total. All these patients included in this study initially underwent open reduction and internal fixation of the distal femoral fractures with a lateral plate, and complained of continued pain over the lateral femoral condyle after the fracture fixation. The average age was 42.6 (ranges: 20~66) and initial fracture types included 16 cases of C1, 11 cases of C2, and 5 cases of C3 following AO/ASIF classification guidelines. Measured outcomes included: associated intra-articular pathologies, time needed to return to activities of daily living, patients' overall satisfaction, complications following the removal of hardware, and pain before and 6 months after the operation. Results: The distal-most end of the plate was placed in the knee joint in all cases and damage of the lateral articular capsule was found in 23 cases. Continuous wound discharge after surgery was found in one case who underwent arthroscopy-assisted plate removal, and it was treated by irrigation and re-suture. Average time needed to return to activities of daily living was 7 days in arthroscopy assisted group and 7.6 days in conventionally removed group. Fourteen patients (82.4%) who underwent arthroscopyassisted plate-removal reported above 'fair' satisfaction and the Visual analog scale pain score decreased from 4.9 to 1.9, six months after the plate removal. Thirteen patients(86.7%) who underwent conventional plate removal reported above 'fair' satisfaction and the Visual analog scale pain score decreased from 5.2 to 2.5, six months after the operation. Conclusion: Through minimally invasive arthroscopic-assisted plate removal, intrarticular pathology of the knee joint was able to be simultaneously identified and treated at the time of hardware removal. Damage of lateral capsule of the knee joint caused by the inserted plate for the treatment of type C distal femoral fracture was very frequently found and following the plate removal, patients experienced an improvement in pain score. We therefore recommend routine lateral distal femoral plate removal if the bony union is attained in such cases as type C distal femoral fractures whose distal most end of the plates are located in the joint.

  • PDF

Ulnar Nerve Injury Caused by the Incomplete Insertion of a Screw Head after Internal Fixation with Dual Locking Plates in AO/OTA Type C2 Distal Humerus Fractures

  • Shin, Jae-Hyuk;Kwon, Whan-Jin;Hyun, Yoon-Suk
    • Clinics in Shoulder and Elbow
    • /
    • v.20 no.4
    • /
    • pp.236-239
    • /
    • 2017
  • After dual plating with a locking compression plate for comminuted intraarticular fractures of the distal humerus, the incidence of ulnar nerve injury after surgery has been reported to be up to 38%. This can be reduced by an anterior transposition of the ulnar nerve but some surgeons believe that extensive handling of the nerve with transposition can increase the risk of an ulnar nerve dysfunction. This paper reports ulnar nerve injuries caused by the incomplete insertion of a screw head in dual plating without an anterior ulnar nerve transposition for AO/OTA type C2 distal humerus fractures. When an anatomical locking plate is applied to a distal humeral fracture, locking screws around the ulnar nerve should be inserted fully without protrusion of the screw because an incompletely inserted screw can cause irritation or injury to the ulnar nerve because the screw head in the locking system usually has a slightly sharp edge because screw head has threads. If the change in insertion angle and resulting protruded head of the screw are unavoidable for firm fixation of fracture, the anterior transposition of the ulnar nerve is recommended over a soft tissue shield.

Treatment of Pilon Fracture using Articulated External Fixator with Hinge (경첩 운동이 가능한 외고정장치를 이용한 Pilon골절의 치료)

  • Park, In-Heon;Lee, Kee-Byung;Song, Kyung-Won;Lee, Jin-Young;Lee, Seung-Yong
    • Journal of Korean Foot and Ankle Society
    • /
    • v.1 no.1
    • /
    • pp.30-37
    • /
    • 1997
  • Pilon fracture is an intraarticular fracture of distal tibia. It is high energy injury with significantly associated soft tissue damage, bone comminution, and articular surface disruption. Until recently, this treatment has followed the AO principles, Because the risk of complications outweighs potential benefits, the principle of a Pilon fracture treatment are changing. Newer techniques using articulated external fixation minimize disturbance of the soft tissue envelope and have decreased these complications. Series of 5 patients with Pilon fracture were treated by articulated external fixator and followed up more than 12 monthes at the Department of orthopaedic surgery, Kang Dong Sacred Heart Hospital, College of medicine, Hallym University. The results were as follows: 1. The type of fracture were type C2(3 cases),type C3(2 cases) according to AO-$M{\ddot{u}}ller$ classification. 2. The clinical results according to functional criteria by Mast and Teipner were good in 4 cases and poor in 1 case, which is an old fracture. 3. Techniques utilizing articulated external fixator were associated with satisfactory results and appeared to significantly decrease the incidence of soft tissue complication, post-traumatic arthritis, osteoporosis, and fibrosis of ankle joint.

  • PDF

A Comparative Study of Interlocking IM Nailing and LCP Fixation through MIPPO Technique in the Treatment of Distal Metaphyseal Tibial Fracture (경골 원위부 골절 치료에서 최소 침습적 접근법을 통한 잠금 나사 금속판 고정술과 교합성 골수강 내 금속정 고정술의 비교 연구)

  • Lee, Chang-Soo;Suh, Jin-Soo;Kim, Ji-Hoon
    • Journal of Korean Foot and Ankle Society
    • /
    • v.12 no.1
    • /
    • pp.80-85
    • /
    • 2008
  • Purpose: To evaluate and compare the outcome between interlocking IM nailing and LCP fixation in the treatment of distal metaphyseal tibial fracture. Materials and Methods: From January 2000 to December 2007, 17 patient were treated by interlocking IM nail and 13 patient were treated by LCP fixation for distal metaphyseal tibial fracture. Results: According to AO classification, there were 2 type A1 fracture (12%), 6 type A2 fracture (36%), 3 type A3 fracture (18%), 4 type B1 fracture (24%), 1 type B3 fracture (6%), 1 type C1 fracture (6%) in interlocking IM nailing group and 1 type A2 fracture (7.7%), 2 type A3 fracture (15.4%), 3 type B1 fracture (23%), 3 type B2 fracture (23%), 3 type C1 fracture (23%), 1 type C2 fracture (7.7%) in LCP fixation group. The clinical functional outcome (according to AOFAS score) is 75.6 point in IM nailing group and 81.5 point in LCP fixation group. In IM nailing group, 65% of patient showed satisfactory result and In LCP fixation group, 77% of patient showed satisfactory result. Conclusion: There is no difference on clinical results between IM nailing and MIPPO (minimal invasive percutaneous plate osteosynthesis) group in the treatment of distal tibia fracture. But MIPPO group have higher subjective satisfactory score and less complication rate. The weakness of our study is a small case number and limited follow-up and we believe a better designed prospective study will be needed.

  • PDF

Treatment of Distal Tibia Fracture using MIPPO Technique with Locking Compression Plate: Comparative Study of the Intraarticular Fracture and Extraarticular Fracture (잠김-압박 금속판을 사용하여 MIPPO 수기를 적용한 원위부 경골 골절의 치료: 관절내 골절과 관절외 골절의 비교)

  • Chung, Soo-Tae;Kim, Hyung-Soo;Cha, Seung-Do;Yoo, Jeong-Hyun;Park, Jai-Hyung;Kim, Joo-Hak;Jung, Jin-Ha
    • Journal of Korean Foot and Ankle Society
    • /
    • v.13 no.2
    • /
    • pp.162-168
    • /
    • 2009
  • Purpose: To evaluate the efficiency of the minimally invasive percutaneous plate osteosynthesis (MIPPO) with locking compression plate (LCP) for distal tibial metaphyseal intra-articular fracture compared with extra-articular fracture. Materials and Methods: From February 2006 to June 2008, 21 patients with distal tibia metaphyseal intra-articular fracture and 20 patients with extra-articular fracture were treated operatively by MIPPO technique with LCP and followed for at least one year. In the group with intra-articular fracture, mean age was 48.85 years old and a mean follow-up was 15 months. In the other group with extra-articular fracture, mean age was 52.35 years old and a mean follow-up was 14.5 months. The type of fracture was evaluated using the AO/OTA classification and open-fractures were according to the Gustilo-And gron classification. Radiologic evaluation with fracture healing and tibial alignment, clinical evaluation with Olerud and Molander ankle score and restriction of motion were done for treatment. Results: According to AO/OTA classification, There were 21 type A, 15 type B, 5 type C. Average union time of the intra-articular fracture (type B, C) was 18.7 weeks. Average union time of the extra-articular fracture (type A) was 17.1 weeks. All fractures were healed without malunion. There were no difference of mean restriction angle between intra-articular fracture (ankle dorsiflexion was 3.57 degree, plantar-flexion was 5.95 degree) and extra-articular fracture (ankle dorsiflexion was 3 degree, plantar-flexion was 3.75 degree). There were no difference of Olerud and Molander ankle score between them as a mean score of intra-articular and extra-articular was 89.25, 91.25 each other. As a complication, there were 3 case of skin necrosis, 8 case of discomfortable skin tenting by plate and 1 superficial infection, but could be healed by conservative care. Conclusion: MIPPO technique, combined articular reduction, with LCP of distal tibial metaphyseal fracture was a good method with high functional recovery.

  • PDF

The Analysis of the Treatment Outcomes of Proximal Humeral Fractures with Locking Plates

  • Lee, Kwang-Won;Hwang, Yoon-Sub;Kim, Choon-Myeon;Yang, Dae-Suk;Park, Tae-Soo
    • Clinics in Shoulder and Elbow
    • /
    • v.17 no.1
    • /
    • pp.10-17
    • /
    • 2014
  • Background: The aim of this study was to assess the clinical outcomes after treatment of proximal humeral fractures with locking plates, and to determine which factors influence the clinical and radiological outcomes. Methods: Fifty six patients who were treated with locking plates for proximal humeral fractures and had been followed for more than 1 year were enrolled in this study. We performed functional evaluation using the Constant score and analyzed radiographic results. The following factors that may potentially influence the clinical outcomes were assessed: age, gender, type of fracture, presence of medial metaphyseal comminution, bone mineral density, anatomical reduction, restoration of medial mechanical support, and postoperative complications. Results: The mean Constant score was 70.1 points at the final follow-up. Female gender, 4-part fractures, AO type-C fractures, and fractures with medial metaphyseal comminution were associated with a poor clinical outcome. On the other hand, restoration of medial mechanical support and accurate anatomical reduction had a positive influence on clinical outcomes. Postoperative complications resulted in 3 patients (intra-articular screw perforation: 1 patient, varus deformity with screw loosening: 1 patient, nonunion: 1 patient). Conclusions: When treating proximal humeral fractures with locking plate fixation, following factors: a female gender, Neer type 4-part fracture, AO type C fracture, and medial metaphyseal comminution are important risk factors that surgeons should take into consideration. Factors that contribute to better clinical outcomes of operative treatment for humeral fractures are accurate anatomical reduction and restoration of medial mechanical support.

Characteristics of Wrist Injuries in Snowboarding (스노보드 손상 환자에 있어서 손목 손상의 특성)

  • Kim, Yeong Jun;Lee, Kang Hyun;Cha, Kyoung Chul;Kim, Hyun;Hwang, Sung Oh;Oh, Jin Rok
    • Journal of Trauma and Injury
    • /
    • v.22 no.1
    • /
    • pp.29-36
    • /
    • 2009
  • Purpose: The purpose of this study was to analyze the characteristics and severity of wrist injuries in snowboarding. Methods: December 2005 to February 2008, Snowboarders who experienced wrist injures were included in this study. On the basis of the medical records and radiographic evaluation, the severity of distal radius fracture was classified according to the Arbeitsgemeinschaft fur Osteosynthesefragen/Association for the Study of Internal Fixation (AO/ASIF) classification. Results: Most of the injured snowboarders were a either of the beginner (35 cases, 46.1%) or the intermediate (27 cases, 35.5%) level. The most common cause of injury in snowboarding was a slip down (60 cases, 78.9%). Comminuted and articular fractures classified as AO types A3, B, and C, which required surgical reduction, made up 42.3% of the distal radial fractures in snowboarders. When we analyzed the differences in severity between the educated and the non-educated groups, an A2 type injury in the AO classification was the most common type of injury in the educated group (20 cases, 38.5%), it means less severe fractures ocurred in the educated group (p=0.045). The most frequent injury mechanism of fractures was slip down (48 cases, 63.2%), and a slip down backwards was the dominant type of slip down (36 cases, 75.0%) (p=0.031). Conclusion: Among the snowboarders in this study who suffered self-down injury to the wrist, more fractures were associated with a backwards slip down than with a forward slip down due to over extension. For educated snowboarders the severity of fracture was lower than it was for uneducated snowboarders.

ILIZAROV FIXATION FOR THE TYPE C TIBIAL PLAFOND FRACTURES (C형 경골천정 골절에 대한 일리자로브 외고정술)

  • Cho, Hyoun-Oh;Kwak, Kyoung-Duck;Cho, Sung-Do;Kim, Byung-Yong;Oh, Jang-Ho
    • Journal of Korean Foot and Ankle Society
    • /
    • v.1 no.1
    • /
    • pp.51-58
    • /
    • 1997
  • The purpose of this study is to evalute the efficacy af the Ilizarov external fixation for the surgical treatment. of the tibial plafond fractures. We reviewed retrospectively fourteen cases of tibial plafond fractures with moderate to severe soft. tissue damage, which were fixed with Ilizarov external fixator. Using the AO Muler classification, there were four Type C1 fractures, six Type C2 and four Type C3. In most, of the cases, the ankles were operated on with other associated fractures within a few days after injury. We reduced the fracture indirectly by soft issue taxis and fixed externally across the ankle joint. using the circular external fixator with tensioned wires and ankle hinge. In cases of inadequate closed reduction, we applied limited open reduction and internal fixation. Range of motion exercise began immediately. Postoperative follow-up averaged fourteen months (ranges, 8-30 months). Overall clinical results rated good or excellent in 7 cases, fair in 4 and poor in 3. There were three cases of pin tract infection which were resolved with short-term antibiotics and local care; one delayed wound closure in a patient. whose fracture was associated with Type III open wound; one wound slough in a patient associated with Type II open wound, which was closed later by skin graft; and one osteoarthritis. From this review, we concluded that cross-ankle circular external fixation with tensioned wires with or without. limited open reduction is a reasonable alternative for the treatment of the tibial plafond fractures with severe soft tissue damage.

  • PDF

Double Tension Band Osteosynthesis in Intra-articular Fractures of the Distal Humerus (AO type C) in Elderly Osteoporotic Patients (고령 환자의 상완골 원위부 AO-C형 골절에서 이중 강선 장력대 고정술)

  • Cheon, Sang Jin;Lee, Dong Ho;Goh, Tae Sik
    • Clinics in Shoulder and Elbow
    • /
    • v.16 no.1
    • /
    • pp.33-39
    • /
    • 2013
  • Purpose: The aim of this study is to evaluate the clinical result of intra-articular fractures of the distal humerus (AO type C) in elderly osteoporotic patients treated with double tension band osteosynthesis. Materials and Methods: From January 2006 to December 2010, 10 elderly osteoporotic patients(1 male, 9 females) with intra-articular fractures of the distal humerus (AO type C) were treated with double tension band osteosynthesis. The mean age of patients at the time of surgery was 74.6(66~84) years and the mean follow-up period was 39.2(20~74) months. The fracture union and complications were assessed and the functional result was evaluated by the rating system of Jupiter et al. and the Mayo elbow performance index. Results: Bone union was achieved in all patients with no secondary displacement. The mean time for union was 16.6(13~22) weeks. The average postoperative arc of elbow flexion was 119(100~140) degrees with a mean flexion contracture of 8.5(0~15) degrees. The recovery in two patients was rated as excellent, in 7 as good, and in 1 as fair in terms of the Mayo elbow performance index with average value of 82(70~90) points. Seven patients were rated as excellent, 1 as good, and 2 as fair in terms of the rating system of Jupiter et al. Changing tension band wiring was performed in one patient as skin irritation was noticed due to tension band knots. Heterotopic ossification developed in one patient but had no symptom. Conclusion: Double tension band osteosynthesis in intra-articular fractures of distal humerus (AO type C) in elderly osteoporotic patients can provide sufficient and secure stability to allow early rehabilitation.

Clinical and Radiological Results of Treating Unstable Distal Radial Fractures with a Domestically Developed Volar Locking Plate That Has the Characteristic of Double-Tiered Subchondral Support (불안정성 원위 요골 골절의 치료에 있어 한국형 이중 연골하지지고정 전방 금속판의 임상적 및 방사선학적 결과)

  • Lee, Chul-Hyung;Jung, Deukhee;An, Chung-Han;Jeong, Uitak
    • Journal of the Korean Orthopaedic Association
    • /
    • v.55 no.6
    • /
    • pp.495-502
    • /
    • 2020
  • Purpose: The aim of this study was to assess the effectiveness of domestically developed volar locking plate which has the concept of double-tiered subchondral support (DSS) in maintaining the reduction after distal radial fracture surgery. Materials and Methods: From July 2017 to December 2018, 54 patients were assessed. Plain radiographs were obtained immediately after surgery and at the last follow-up, and the radiographic parameters were measured in those images: radial length, radial inclination, volar tilt, ulnar variance, and distal dorsal cortical distance. The patients were subdivided into their age, type of fracture, and the position of the plate to evaluate the influence of each factors on the reduction maintenance. Results: Distal dorsal cortical distance in radiographs after the surgery was 5.91 mm (standard deviation, ±1.95 mm) on average. Significant differences in the radial length (p=0.038) and ulnar variance (p=0.001) were observed between immediately after surgery and at the last follow-up. When the parameters were evaluated by dividing the patients into subgroups according to the three specific factors, the ulnar variance showed a significant increase at the last follow-up when the patients were included 65-years-old or older. AO/OTA type C3 fracture, and Soong classification grade 0 plate position (p=0.007, p=0.012, p=0.046, respectively). Conclusion: Using the domestically developed DSS-type volar locking plate, significant reduction after distal radial fracture surgery could be maintained successfully. On the other hand, further study will be needed to determine about the reduction loss of the lunate facet identified in special cases that deal with fractures in elderly patients, unstable AO/OTA type C3 distal radial fractures, and Soong classification grade 0 plate position.