• Title/Summary/Keyword: ANOM

Search Result 37, Processing Time 0.023 seconds

An Optimization for Flow Control Butterfly Valve using Grey Relational Analysis (회색 관계 분석을 이용한 유량 제어용 버터플라이밸브 형상 최적화)

  • Lee, Sang Beom;Lee, Dong Myung
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.26 no.6
    • /
    • pp.359-366
    • /
    • 2014
  • This paper considered optimization method of appending a shape on a disc in an attempt to improve core functions, which are inherent in flow characteristics. The paper also verifies the optimization method of appendage shape with a Class 150 200A Butterfly valve. Then the design of experiment (DOE) with an orthogonal array is performed to analyze the effect of form parameters by grey relational analysis and analysis of mean (ANOM). And this study sets flow coefficient as an object functions for optimization, and the conventional disc model and the optimal appendage shape on disc model are compared by computational fluid analysis. The paper concludes that an optimal appendage shape on disc model achieves wider usability by a wider operating range.

Approximate Multi-Objective Optimization of A Wall-mounted Monitor Bracket Arm Considering Strength Design Conditions (강도조건을 고려한 벽걸이 모니터 브라켓 암의 다중목적 근사최적설계)

  • Doh, Jaehyeok;Lee, Jongsoo
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.39 no.5
    • /
    • pp.535-541
    • /
    • 2015
  • In this study, an approximate multi-objective optimization of a wall-mounted monitor bracket arm was performed. The rotation angle of the bracket arm was determined considering the inplane degree of freedom. We then formulated an optimization problem on maximum stress and deflection. Analyses of mean and design parameters were conducted for sensitivity regarding performance with orthogonal array and response surface method (RSM). RSM models of objective and constraint functions were generated using central composite (CCD) and D-optimal design. The accuracy of approximate models was evaluated through $R^2$ value. The obtained optimal solutions by non-dominant sorting genetic algorithm (NSGA-II) were validated through the finite element analysis and we compared the obtained optimal solution by CCD and D-optimal design.

Sensitivity Analysis of Design Parameters for Quadruple Offset Butterfly Valve by Operating Torque (작동 토크를 평가 함수로 하는 사중편심 버터플라이밸브 설계 파라미터 민감도 분석)

  • Lee, Dong-Myung;Kim, Soo-Young
    • Journal of Ocean Engineering and Technology
    • /
    • v.28 no.2
    • /
    • pp.160-166
    • /
    • 2014
  • Because of industrial development, industrial facilities are becoming more complex and diversified. Plant industries are focused on productivity improvement, cost reduction, and product uniformity by simplifying production processes using automated control. Furthermore, plant industries require higher pressures and temperatures to improve energy efficiency. For this reason, the valves used in plants are operated under harsh conditions. Globe valves and gate valves are mainly used for high pressure these days. However, these valves have various problems, including low maintainability and high cost, due to structural problems. Therefore, butterfly and ball valve applications are increasing in industrial plants. This paper suggests a quadruple-offset butterfly valve that is applicable to bi-direction use, and the principle design parameters are suggested. The selected design parameters are an eccentric flange center line and shaft centerline(Offset 1), an eccentric seat centerline and disc shaft centerline(Offset 2), the angle between the flange centerline and seat wedge angle(Offset 3), the angle between the vertical direction of the disc shaft centerline and seat centerline(Offset 4), and the seat engagement angle. To analyze the interaction effect of the design parameters, ANOM and ANOVA were performed with an orthogonal array. The parameters were found to have effects in the following order: Offset 2, Offset 1, engagement angle, Offset 3, and Offset 4. The interaction between the parameters was insignificant.

Optimization of Lace Tube with Gray Theory and Design of Experiment (회색 관계 이론과 실험계획을 이용한 Lance Tube Nozzle 최적화)

  • Jeong, Ilkab;Lee, Dongmyung;Lee, Sangbeom;Lim, Jintaek
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.65 no.6
    • /
    • pp.1001-1006
    • /
    • 2016
  • As consumption of energy is increasing rapidly, energy saving is emphasized in nowadays. Thermal power plant occupies a large proportion in various type of power plant. Major causes of decreased power generation efficiency on thermal power stations is deposition of fly ash. Soot Blower is a facility to remove the ash which is deposited outside of tube by steam blowing on boiler. Residual stream which caused by lance tube in soot blower cannot be discharged steam effectively in lance tube causes reducing the thickness of lance tube. On the contrary, increasing discharge ratio of steam, lance tube cannot sustain proper pressure to remove ash on tube. This study suggests increasing discharge ratio of steam with proper pressure to remove ash on tube by optimization on shape of lance tube nozzle. To optimize shape of nozzle, discharge ratio and maximum blowing pressure on nozzle is selected as object functions. Diameter of nozzle, distance between nozzles, angle of nozzle and gap between nozzle is selected as design parameters. Then the design of experiment (DOE) with an orthogonal array is performed to analyze the effect of design parameters. And grey relational analysis and analysis of mean (ANOM) is performed to optimize shape of lance tube.

Extraction of Moho Undulation of the Korean Peninsula from Gravity Anom-alies (중력이상을 이용한 한반도 모호면 추출에 관한 연구)

  • 김정우;조진동;김원균;민경덕;황재하;이윤수;박찬홍;권재현;황종선
    • Economic and Environmental Geology
    • /
    • v.36 no.3
    • /
    • pp.213-223
    • /
    • 2003
  • We estimated the Moho depth of Korean Peninsula from gravity anomalies and digital elevation model. The satellite radar altimetry-derived global free-air gravity model was used to ensure the homogeneity in both data and frequency domains of the original data. Two different methods were implemented to calculate the Moho depth; the wavenumber correlation analysis (Kim et al., 2000a) and the power spectrum analysis. The former method calculates depth-to-the-Moho by correlating topographic gravity effect with free-air gravity anomaly in the wavenumber domain under the assumption that the study area is not isostatically compensated. The latter one, on the other hand, considers the different density layers (i.e., Conrad and Moho), using complete Bouguer gravity anomaly in the Frequency domain of the Fourier transform. The correlation coefficient of the two Moho model is 0.53, and methodology and numerical error are mainly responsible for any mismatch between the two models. In order to integrate the two independentely-estimated models, we applied least-squares adjustment using the differenced depth. The resultant model has mean and standard deviation Moho depths of 32.0 km and 2.5 km with (min, max) depths of (20.3, 36.6) kms. Although this result does not include any topographic gravity effect, however, the validity of isostasy and the role of local stress field in the study area should be further studied.

Surgical Treatment of Coarctation of the Aorta (대동맥축착증의 외과적치료)

  • 성시찬;방정희
    • Journal of Chest Surgery
    • /
    • v.30 no.11
    • /
    • pp.1069-1076
    • /
    • 1997
  • There remains controversy regarding the appropriate surgical treatment for coarctation of the aorta because of relatively high rate of recoartation and high mortality in the cases associated with complex anomalies. We evaluated 31 consecutive patients who underwent surgical repair of coarctation of the aorta from May 1992 through June 1996. Nineteen patients(61.3%) were neonates and 26(83.9%) were under three months. Nine patients did not have major associated anom lies(Group I), 15 patients had ventricular septal defect(Group II), and 7 patients had major complex anomalies(Group III). 35.5% of the patients had arch hypoplasia. Surgical procedures performed were as follows: extended end-to-end anastomosis in 17 patients, combined resection-flap procedure in 7 patients, and subclavian flap aortoplasty in 7 patients. Residual coarctation occurred in 7(25%) of 28 patients; 2 after subclavian (lap aortoplasty(2/6, 33.3%), none after combillrd resection-flap procedure(0/7, 0%), and 5 after extended end-to-end anastomosis(5/15, 33.3%). Higher incidence of residual coarctation was noticed in the group with arch hypoplasia. The incidence of postoperative coarctation at a mean follow-up of 20.5 months in survivals was 12.0%(3/25); 2 cases after subclavian flap aortoplasty(2/6, 33.3%), none after combined resection-flap procedure(017, 0%), and one after endtoend anastomosis(1/12, 8.3%). The mortality rate related to coarctation repair was 9.7%(3 patients all in Group III). This study revealed that isolated coarctation of aorta and coarctation with ventricular septal di3fect(groups I & ll) can be repaired with low mortality, but repair of coarctation with complex anomaly had a high operative mortality Also the patients with arch hypoplasia had higher incidence of post-operative residual coarctation.

  • PDF

Surgical Treatment of Pulmonary Atresia with Intact Ventricular Septum -Effect of the size of tricuspid valve annulus on the surgical outcome- (영아기에 발견된 심실중격이 온전한 폐동맥 폐쇄증의 외과적 수술요법 술전 삼첨판륜 크기 가 수술 결과에 미치는 영향)

  • 이정렬;윤태진
    • Journal of Chest Surgery
    • /
    • v.29 no.10
    • /
    • pp.1081-1089
    • /
    • 1996
  • Pulmonary atresia with intact ventricular septum has continued to have a high surgical mortality and morbidity. This mAy attribute to the non-uniformity of the anomaly. We reviewed a total of 34 infants with pulmonary atresla and intact ventricular septum managed in this hospital between 1987 and 1995. Mean age and body weight were 57.2 (range, 3-208) days and 4.1 (range, B.3∼6.8) kg. The preoperative Z-value of the diameter of the tricuspid valve was less than -2 in 85.2% of patients and less than -4 in 33. 3% . It is well correlated w th right ventricular cavity size (n=27. r10.68, p< 0.05). Coronary artery-right ventricular fistulas were identified in 3 patients, and right ventricular dependency was suspected in 1 Over All hospital mortality was 23.5%(8/34), although it decreased to 16.6%(4124) in 1990s. Subsequent procedures were performed in 6 patients between 3 days and 58 months after Initial palliation : one bidirectional cavopulmonary shunt and 1 Fontan operation after systemic-pulmonary shunt, 3 transannular patch + atrial septal defect closure and 1 additional systemic-pulmonary shunt after polmonary valvectomy or valvotomy. Changes of Z-values of the diameter of tricuspid valve have been followed up in 11 patients between 1 and 66 months postoperatively. Z-values were increased In 5 out of 8 transannular right ventriculAr outflow tract enlargement group and in 1 out of 3 pulmonary valvectomy or valvotomy group. Our data suggest that tailoring a treatment to right ventricular cavity size and coronary anom lies may improve the surgical outcome. A Z-value of the tricuspid valve diameter could be used.

  • PDF