• Title/Summary/Keyword: ALIQUAT 336

Search Result 46, Processing Time 0.016 seconds

Treatment of ground waters in a hollow-fibre liquid membrane contactor for removal of ions

  • Hossain, Md. M.
    • Membrane and Water Treatment
    • /
    • v.4 no.2
    • /
    • pp.95-108
    • /
    • 2013
  • Metal ions exist in seawater, groundwater and industrial wastewaters. These source waters can be recycled if their concentrations are reduced. A number of processes can be applied for this purpose. Liquid-liquid extraction is one of the promising methods. In this paper, experimental results are presented on the removal of Cr(VI) using Aliquat-336, a reactive carrier, in sunflower oil (a non-toxic solvent). The performance of this new system is compared with those of kerosene (a toxic solvent). The extent of removal of Cr(VI) from samples with high and low concentrations are presented. The process was upgraded to a bench-scale module that can selectively remove about 50-90% Cr(VI) from samples of groundwater. Thus this process can produce water within the acceptable range for recycling and for use in secondary purposes such as irrigation.

Perchlorate Ion-Selective PVC Membrane Electrode Based on the Quaternary Ammonium Salts (제4급 암모늄염을 이용한 과염소산 이온선택성 PVC막 전극)

  • 안형환;김용렬;강현춘;이한섭;이병철;강안수
    • Membrane Journal
    • /
    • v.3 no.3
    • /
    • pp.126-135
    • /
    • 1993
  • Perchlorate ion-selective PVC membrane electrode responsive to $10^{-6}M$ was developed by incorporating the ion-pair complex of perchlorate with the quaternary ammonium salts as a active material. The effect of chemical structure, the content of active material, the kinds of plasticizers, and the membrane thickness on the electrode characteristics such as the linear response range and Nernstian slope of the electrode were studied. With the results, the useful pH range and the selectivity coefficients to various interfering anions were compared and investigated. It was obtained that the effect of the chemical structure of an active material on the electrode characteristics was improved with increasing the alkyl chain length of the quarternary ammonium salts in the ascending order of Aliquat 336P, TOAP, TDAP, and TDDAP. The electrode characteristics was improved with the decrease of the active material content below the optimum membrane composition, and DBP was the best as a plasticizer. The optimum membrane composition was 9.09wt% of TDDAP, 30.3wt% of PVC, and 60.6wt% of ptasticizer(DBP). And the optimum membrane thickness was0.45mm at this composition. Under the above condition, thelinear response ranger was $10^{-1}~1.2 {\times} 10^{-6}M$, and the detection limit was $5.1{\times}10^{-7}M$ with the Nernstian slope of 57mV/decade of activity of perchlorate ion. The electrode potential was stable within the pH range from 4 to 11. The selectivity coefficient was as shown below : $SCN^->I^->NO_3^->Br^->ClO_3^->F^->Cl^->SO_4^{2-}$

  • PDF

Recovery of the Vanadium and Tungsten from Spent SCR Catalyst Leach Solutions by Hydrometallurgical Methods (SCR 폐촉매 침출액으로부터 습식제련법에 의한 바나듐, 텅스텐의 회수)

  • Choi, In-Hyeok;Moon, Gyeonghye;Jeon, Jong-Hyuk;Lee, Jin-Young;Jyothi, Rajesh Kumar
    • Resources Recycling
    • /
    • v.29 no.2
    • /
    • pp.62-68
    • /
    • 2020
  • In new millennium, wide-reaching demands for selective catalytic reduction (SCR) catalyst have been increased gradually in new millennium. SCR catalyst can prevent the NOx emission to protect the environment. In SCR catalyst the main composition of the catalyst is typically TiO2 (70~80%), WO3 (7~10%), V2O5 (~1%) and others. When the SCR catalysts are used up and disposed to landfills, it is problematic that those should exist in the landfill site permanently due to their extremely low degradability. A new advanced technology needs to be developed primarily to protect environment and then recover the valuable metals. Hydrometallurgical techniques such as leaching and liquid-liquid extraction was designed and developed for the spent SCR catalyst processing. In a first stage, V and W selectively leached from spent SCR catalyst, then both the metals were processed by liquid-liquid extraction process. Various commercial extractants such as D2EHPA, PC 88A, TBP, Cyanex 272, Aliquat 336 were tested for selective extraction of title metals. Scrubbing and stripping studies were tested and optimized for vanadium and tungsten extraction and possible separation. 3rd phase studies were optimized by using iso-decanol reagent.

The Polymer Membrane Electrode by Surfactants for Measuring Continuously Thiocyanate Ion in Wastewater (폐수중 티오시안산이온을 측정하기 위한 계면활성제를 이용한 고분자 막전극)

  • 최종석;안형환;강안수;우인성;황명환
    • Journal of the Korean Society of Safety
    • /
    • v.6 no.4
    • /
    • pp.13-20
    • /
    • 1991
  • Ion-selective electrode responsive to the thiocynate ion prepared by using the quaternary ammonium salts as a active material and PVC as a membrane matrix. The effect of chemical structure and composition of active material, and the membrane thickness on the linear response. the detection limit, and Nernstian slope of the electrode studied. Under the above optimum conditions of membrane, the effect of pH and the selectivity coefficients to various interfering anions were compared and investigated. It was concluded that the functions of thiocynate ion-selective electrode(ISE) were closely related to the chemical structure of the quaternary ammonium salts. The linear response, and the detection limit of the electrode potential increased with the increase of the carbon chain length of the alkyl group in the quaternary ammonium salts in the ascending order of Aliquat 336T, TOAT, TDAT, and TDDAT. The optimum membrane thickness was 0.3mm. The electrode characteristics was better with the decrease of the concentration of active material, and the best concentration was 3 weight percent. The membrane potential was independent of the pH variation in the region from pH 2 to 12. The order of the selectivity coefficients is as follows:Cl $O_4$$^{[-10]}$$I^{[-10]}$ >N $O_3$$^{[-10]}$ >B $r^{[-10]}$$F^{[-10]}$ >C $l^{[-10]}$ >O $A_{c}$ $^{[-10]}$ 〓S $O_4$$^{2-}$.

  • PDF

Separation and Determination of Cadmium in Blood Serum by Solvent Extraction and Atomic Absorption Spectrophotometry (용매추출과 원자흡수분광법에 의한 혈청시료중 카드뮴의 분리 및 정량)

  • Lee, Seok Ki;Joung, Chang Ung
    • Journal of the Korean Chemical Society
    • /
    • v.43 no.4
    • /
    • pp.401-406
    • /
    • 1999
  • Trace amount of cadmium was quantitatively extracted with 1% Aliquat 336-MIBK from 0.2M KSCN and 0.01M-HCl. Test tubes with a screw cap stopper were used for extraction in place of conventional separating funnels and organic solvents used were less dense than water. In this analysis, 22 times concentration effect was achieved with higher selectivity without interference. The detection limit of cadmium was 0.7ppb, therefore trace cadmium was easily analyzed by this method. The proposed method was applied to the determination of cadmium in blood serum and extraction mechanism was elucidated.

  • PDF

Fabrication of Perchlorate Ion Selective PVC Membrane Electrode (과염소산 이온선택성 PVC막전극 제작)

  • 우인성;안형환;강안수
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.11 no.4
    • /
    • pp.298-305
    • /
    • 1998
  • The PVC membrane electrode for measuring perchlorate ion was developed by incorporating various quaternary ammonium sallts. The effect of chemical structure, the content of active material, the kind of plasticizers, and the membrane thickness on the electrode characteristic such as the linear response range and Nernstian slope of the electrode were studied. It was obtained that the effect of the chemical structure of an active material on the electrode characteristics was improved with increasing the alkyl chain length of the quarternary ammonium salts in the ascending order of Aliquat 336P, TOAP, TDAP, and TDDAP. The optimum membrane composition was 9.09wt% of TDDAP, 30.3wt% of PVC, and 60.6wt% of plasticizer(DBP). And the optimum membrane thickness was 0.45mm at this composition. Under the above condition, the linear response range was $10^{-1}~1.2\times10^{-6}$M, and the detection limit was $5.1\times10^{-7}$M with the Nernstian slope of 57mV/decade of activity of perchlorate ion. The electrode potential was stable within the pH range from 4 to 11. The selectivity coefficient was as shown below: $SCN^->I^-NO_3^->Br^->ClO_3^->F^->Cl^->SO_4^{2-}$

  • PDF