• Title/Summary/Keyword: AIR 모델

Search Result 2,267, Processing Time 0.029 seconds

Prediction Model Design by Concentration Type for Improving PM10 Prediction Performance (PM10 예측 성능 향상을 위한 농도별 예측 모델 설계)

  • Kyoung-Woo Cho;Yong-jin Jung;Chang-Heon Oh
    • Journal of Advanced Navigation Technology
    • /
    • v.25 no.6
    • /
    • pp.576-581
    • /
    • 2021
  • Compared to a low concentration, a high concentration clearly entails limitations in terms of predictive performance owing to differences in its frequency and environment of occurrence. To resolve this problem, in this study, an artificial intelligence neural network algorithm was used to classify low and high concentrations; furthermore, two prediction models trained using the characteristics of the classified concentration types were used for prediction. To this end, we constructed training datasets using weather and air pollutant data collected over a decade in the Cheonan region. We designed a DNN-based classification model to classify low and high concentrations; further, we designed low- and high-concentration prediction models to reflect characteristics by concentration type based on the low and high concentrations classified through the classification model. According to the results of the performance assessment of the prediction model by concentration type, the low- and high-concentration prediction accuracies were 90.38% and 96.37%, respectively.

Thermal Design of a Cooling Coil for Building Air Conditioning (건물 공조용 냉수 코일의 열 설계)

  • Kim, Nae-Hyun;Byun, Ho-Won
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.10
    • /
    • pp.6445-6452
    • /
    • 2015
  • The surface of the cooling coil becomes dry, wet or partially wet depending on the operating condition. Thus, a proper design of the cooling coil should include a heat transfer analysis on dry, wet or partially wet surfaces. In this study, an elementary model, which analyzes the cooling on an elementaty basis, is proposed. Comparison of the predictions of the model with experimental data of the cooling coil revealed that heat transfer rates were predicted within 10.1%, airside pressure drop within 11.1% and sensible heat ratio within 5.7%. The model was used to investigate the effect of water circuitory on cooling coil performance.

A Quantitative Analysis on the Extinguishing Mechanism of Laminar Diffusion Flames by $CO_2$ ($CO_2$에 의한 층류 확산화염의 소화기구에 관한 정량적 분석)

  • Mun, Sun-Yeo;Hwang, Cheol-Hong;Oh, Chang-Bo;Park, Won-Hee
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2011.11a
    • /
    • pp.378-381
    • /
    • 2011
  • 대표적 가스계 소화약제인 $CO_2$의 소화기구(Extinguishing mechanism)를 재조명하기 위하여, $CH_4$/air 저 신장율 대향류 확산화염을 대상으로 $CO_2$가 소화에 미치는 영향에 대한 수치해석이 수행되었다. 부력이 지배적인 화염의 소화현상은 복사 열손실에 의해 큰 영향을 받기 때문에, 소화농도 예측에 대한 복사모델의 성능평가가 우선적으로 이루어졌다. 주요 결과로서, 공기류에 첨가된 $CO_2$의 소화농도는 복사모델이 고려되지 않은 경우 과다 예측되는 반면에, 간략화된 광학적으로 얇은 근사(Optically thin approximation) 모델과 비교적 높은 정확도를 갖는 좁은 밴드(Statistical narrow band) 모델은 실험의 오차범위 내에서 큰 차이를 보이지 않았다. $CO_2$가 소화에 미치는 순수 희석효과, 희석에 의한 복사효과, 화학적 효과 및 열적효과를 정량적으로 분석하기 위하여 가상의 소화약제의 개념을 도입하였다. 이를 통해 화염의 총괄신장율에 따른 $CO_2$ 소화효과에 대한 구체적인 이해가 시도되었다.

  • PDF

Security Architecture and Model in Aeronautical Communication Network (항공통신 네트워크에서 보안구조 및 모델)

  • Hong, Jin-Keun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.10 no.1
    • /
    • pp.122-127
    • /
    • 2009
  • In this paper, it is reviewed security architecture and proposed security model about secure aeronautical system, which is considering in the cynical research topics out of aeronautical traffic system. The reviewed contents is treated about security model fur domestic aeronautical system with international security technology trends in the basis of security technology related aeronautical services. In the security framework of aeronautical communication network, it is analyzed data link security technology between air and ground communication, and security architecture in according to aeronautical system, and presented security architecture of U information HUB model. The security architecture of U-information HUB includes the internetworking scope of airline, airport network, airplane network, and related government agency, etc.

Integrated Flight Simulation Program for Multicopter Drones by Using Acausal and Object-Oriented Language Modelica (비인과, 객체지향적 언어 모델리카를 이용한 멀티콥터형 드론의 통합 비행 시뮬레이션 프로그램)

  • Jin, Jaehyun
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.45 no.5
    • /
    • pp.437-446
    • /
    • 2017
  • An integrated flight simulation program for multicopter drones is presented. The program includes rigid body dynamics, propeller thrust, battery energy, control, and air. Using this program, users can monitor and analyze the states of drones along flight trajectories. As a programming language, Modelica has been chosen, that specializes in simulation program development. Modelica enables users to develop simulation programs efficiently due to acausal and object oriented properties. For missions including horizontal and vertical maneuvers, many dynamical states of drones have been analyzed with simulation results.

Numerical Analysis of Natural Convection in Room Fire (화재실내 자연대류의 수치해석)

  • Jung Gil-Soon;Lee Seung-Man;Lee Byung-Kon
    • Fire Science and Engineering
    • /
    • v.19 no.4 s.60
    • /
    • pp.18-25
    • /
    • 2005
  • In this study, numerical analysis of two-dimensional unsteady natural convection of air in a square enclosure heated from below, was performed as a basic research of fire science. SIMPLE algorithm was used to the pressure term of momentum equations in the numerical analysis. The numerical analysis were studied for the two model cases and two heat conditions, respectively, which are different with insulation of enclosures and position of heat applied. Also, the ceiling temperatures of enclosure were measured to compare the accuracy of numerical analysis, and it is found that the temperature predicted by numerical analysis were agreed well with the measurements. Streamline and isotherm of the each model case were acquired for each time step.

Development of Prediction Models of Dressroom Surface Condensation - A nodal network model and a data-driven model - (드레스룸 표면 결로 발생 예측 모델 개발 - 노달 모델과 데이터 기반 모델 -)

  • Ju, Eun Ji;Lee, June Hae;Park, Cheol-Soo;Yeo, Myoung Souk
    • Journal of the Architectural Institute of Korea Structure & Construction
    • /
    • v.36 no.3
    • /
    • pp.169-176
    • /
    • 2020
  • The authors developed a nodal network model that simulates the flow of moist air and the thermal behavior of a target area. The nodal network model was enhanced using a parameter estimation technique based on the measured temperature, humidity, and schedule data. However, the nodal model is not good enough for predicting humidity of the target space, having 55.6% of CVRMSE. It is because re-evaporation effect could not be modeled due to uncertain factors in the field measurement. Hence, a data-driven model was introduced using an artificial neural network (ANN). It was found that the data-driven model is suitable for predicting the condensation compared to the nodal model satisfying ASHRAE Guideline with 3.36% of CVRMSE for temprature, relative humidity, and surface temperature on average. The model will be embedded in automated devices for real-time predictive control, to minimize the risk of surface condensation at dressroom in an apartment housing.

Air-sparging Technology for Remediation of Specific Aquifer Layer Using Surfactant (계면활성제를 이용한 오염대수층의 선택적 폭기기술)

  • Kim, Heon-Ki;Song, Young-Su;Kwon, Han-Joon
    • Journal of Soil and Groundwater Environment
    • /
    • v.13 no.6
    • /
    • pp.23-30
    • /
    • 2008
  • Air sparging technique has been used for remediation of VOC(volatile organic compound)-contaminated aquifer. The aim of this study was to develop an innovative air sparging technique that enhances the efficiency of air intrusion into a specific horizontal layer of aquifer where the contaminants exist with the help of water-soluble surfactant. A twodimensional physical box model, packed with homogeneous sand, was used for simulating the aquifer in this study. Aqueous solution of anionic surfactant (100 mg/L, sodium dodecylbenzene sulfonate) was used to suppress the surface tension of groundwater. Three sets of experiments were conducted: air sparging experiment without surfactant application, air sparging experiments for box model where the surfactant solution was applied right above the air injection point, and air sparging experiments with surfactant solution layer formed in the middle of the box. It was found that the sparging influence zone was expanded up to five times of that formed by sparging without surfactant application. The size of sparging influence zone was more sensitive to the air flow (injection) rate with surfactant application than that without surfactant. More importantly, injection of air into the target aquifer layer was successful with surfactant application. Findings in this study are expected to provide more options for designing remediation processes using air sparging.

Geoacoustic Model of Coastal Bottom Strata at Jeongdongjin in the Korean Continental Margin of the East Sea (동해 한국대륙주변부 정동진 연안 지층의 지음향 모델)

  • Ryang, Woo-Hun;Kim, Seong-Pil;Kim, Dae-Choul;Hahn, Jooyoung
    • Journal of the Korean earth science society
    • /
    • v.37 no.4
    • /
    • pp.200-210
    • /
    • 2016
  • Geoacoustic modeling is used to predict sound transmission through submarine bottom layers of sedimentary strata and acoustic basement. This study reconstructed four geoacoustic models for sediments of 50 m thick at the Jeongdongjin area in the western continental margin of the East Sea. Bottom models were based on the data of the highresolution air-gun seismic and subbottom profiles (SBP) with sediment cores. P-wave speed was measured by the pulse transmission technique, and the resonance frequency of piezoelectric transducers was maintained at 1MHz. Measurements of 42 P-wave speeds and 41 attenuations were fulfilled in three core sediments. For actual modeling, the P-wave speeds of the models were compensated to in situ depth below the sea floor using the Hamilton method. These geoacoustic models of coastal bottom strata will be used for geoacoustic and underwater acoustic experiments reflecting vertical and lateral variability of geoacoustic properties in the Jeongdongjin area of the East Sea.

Assessment of MARS Multi-dimensional Two-phase Turbulent Flow Models for the Nuclear System Analysis (발전소 계통해석을 위한 MARS 코드의 다차원 이상 난류 유동 모델 검증계산)

  • Lee S.M.;Lee U.C.;Bae S.W.;Chung B.D.
    • Journal of Energy Engineering
    • /
    • v.15 no.1 s.45
    • /
    • pp.1-7
    • /
    • 2006
  • The multi-dimensional two-phase flow models were developed for analyze the multi-dimensional behaviors or nuclear systems. To verify the simple turbulence model, The single phase mixing problem in a rectangular slab was calculated and compared with the commercial CFD code results. That result shows a good agreement with the CFD result. And the RPI Air-water experiments were simulated to assess the two-phase turbulence model in the multi-dimensional component. The first calculated distribution or void-fraction is highly dispersed and diffusive. It was revealed that the main reason is undesirable stratification force in a horizontal stratified flow regimes. Therefore the horizontally stratified flow regime is deleted because the stratified flow regime is not expected in multi-dimensional flow. With the modification of the flow regime, the predicted flow patterns and void fraction profiles are in good agreement with the measured data.