• Title/Summary/Keyword: AIR 모델

Search Result 2,267, Processing Time 0.031 seconds

Development Method of BIM Data Modeling Guide for Facility Management : Focusing on Building Mechanical System (시설물 유지관리를 위한 BIM 데이터 입력기준 개발방안 : 건축 기계설비를 중심으로)

  • Won, Ji-Sun;Cho, Geun-Ha;Ju, Ki-Beom
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.25 no.4
    • /
    • pp.216-224
    • /
    • 2013
  • Facility data is created throughout the design and construction phase. But the most facility managers bear significant costs that arise from the lack of interoperability with facility lifecycle. This paper is concerned with the way to collect facility data using BIM technology. The aim of this paper is to suggest BIM data modeling guide for the facility management using the information that need to be delivered from design and construction phase to operation and management phase. The BIM data modeling guide focus on the properties of mechanical equipment. It is to be hoped that this study will contribute to collect facility data from as-built BIM data and to build facility management system database without difficulty.

Quantitative Exposure Assessment of Indoor Radon Released from Groundwater (지하수로부터의 실내 라돈오염에 의한 정량적인 인체노출평가)

  • Yu, Dong-Han;Kim, Sang-Joon
    • Journal of Radiation Protection and Research
    • /
    • v.26 no.2
    • /
    • pp.79-86
    • /
    • 2001
  • This study presents the quantitative exposure assessment of indoor radon released from groundwater. Most of the Indoor radon comes directly from soil beneath the basement or foundation. Recently, radon in groundwater releases to indoor air whenever the water is used and contributes to the total inhalation risk from indoor air. This study first develops a mathematical model to describe the transfer and distribution of radon released from groundwater in a house. Then, daily human exposures through inhalation or such radon are estimated with the model for an male adult based on two sets of exposure scenarios. The results obtained from the study would help increase the understanding of risk assessment issues associated with the indoor radon released from groundwater.

  • PDF

A Numerical Study on Evaporation and Combustion of Liquid Spray (액체분무의 증발 및 연소에 관한 수치적 연구)

  • 정인철;이상용;백승욱
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.15 no.6
    • /
    • pp.2073-2082
    • /
    • 1991
  • The vaporization and combustion of liquid spray in a cylindrical shape combustor was studied numerically. Mixture of liquid drops and air was assumed to be ejected from the center-hole and assisting air from the concentric annulus with swirling. Eulerian-Lagrangian scheme was adopted for the two phase calculation, and the interactions between the phases were considered with the PSIC model. Also adopted were the infinite conductivity model for drop vaporization, the equation of Arrhenius and the eddy break-up model for reaction rate, and the k-epsilon model for turbulence calculations. Gas flow patterns, drop trajectories and contours of temperature and mass fractions of the gas species were predicted with swirl number, drop diameter, and equivalence ratio taken as parameters. Calculations show that the vaporization and the consequent combustion efficiency enhance with the increase of the swirl number and/or with the decrease of drop size, and the higher maximum temperature is attained with the higher equivalence ratio.

Adsorption Characteristics of Short Grain Rough Rice (단립종 벼의 수분흡습특성)

  • 김종순;고학균;송대빈
    • Journal of Biosystems Engineering
    • /
    • v.23 no.5
    • /
    • pp.465-472
    • /
    • 1998
  • In this study short gain rough rice(Chu-cheong) with initial moisture content of around 12%(w.b.) was exposed to 3 levels of relative humidity(70, 80 and 90%) and 3 levels of temperature(20, 25 and 3$0^{\circ}C$) of the air, in order to evaluate the adsorption characteristics of rough rice and the rate of cracked kernels which will serve as the basic data when developing the quality adjusting equipment. The result showed that the moisture content of rough rice increased rapidly during the early stages of moisture adsorption like other grains, and at least 70% of the adsorption occurred within the first 24 hours of exposure to the humid environment. Adsorption rate was more related to relative humidity than the temperature of air stream, and the higher the relative humidity, the higher the adsorption rate. And the Page's equation predicted best the adsorption process of this study. Experimental results for the crack generation during the adsorption process showed that the higher the relative humidity the more the cracked kernels, and that the temperature had little effect. An empirical equation was developed to predict the crack ratio for the conditions of this study, and Nishiyama model predicted better the crack generation than Hoerl model.

  • PDF

Development of the Calibration Method for the Boost Pressure and EGR Rate of a WGT Diesel Engine Using Mean Value Model (평균값 모델을 활용한 WGT 디젤엔진의 과급압력 및 EGR율 보정 방법 개발)

  • Chung, Jaewoo;Kim, Namho;Lim, Changhyun;Kim, Deokjin;Kim, Kiyong
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.24 no.3
    • /
    • pp.319-329
    • /
    • 2016
  • Globally, many researchers have been trying to improve the fuel economy of a vehicle for satisfying future $CO_2$ regulation and minimizing air pollution problem. For the same background, diesel engine and vehicle system optimization using simulation models have been key technologies for the improvement of vehicle system efficiency. Therefore, in this study, calibration method for the air breathing system of a WGT diesel engine using mean value model has been composed for efficient engine and vehicle optimization simulation researches. And virtual WGT performances have been calculated for a 2 cylinder downsized diesel engine system. From these researches, the calibration method for the boost pressure and EGR rate of a virtual diesel engine related with WGT performances could be composed and some of technical issue related with downsized diesel engine could be investigated.

Development of a Three-Dimensional Numerical Model of the Vertical Ground-Coupled Heat Exchanger Considering the Effects of the Thermal Capacity (내부 열용량을 고려한 수직 지중열교환기의 3차원 수치 모델 개발)

  • Kim, Eui-Jong
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.28 no.7
    • /
    • pp.293-298
    • /
    • 2016
  • A three-dimensional (3D) numerical model of the vertical ground-coupled heat exchanger is useful for analyzing the modern ground source heat pump system. Furthermore, a detailed description of the inner side of the exchanger allows to account for the effects of the thermal capacity. Thus, both methods are included in the proposed numerical model. For the ground portion, a FDM (Finite Difference Method) scheme has been applied using the Cartesian coordinate system. Cylindrical grids are applied for the borehole portion, and the U-tube configuration is adjusted at the grid, keeping the area and distance unchanged. Two sub-models are numerically coupled at each time-step using an iterative method for convergence. The model is validated by a reference 3D model under a continuous heat injection case. The results from a periodic heat injection input show that the proposed thermal capacity model reacts more slowly to the changes, resulting in lower borehole wall temperatures, when compared with a thermal resistance model. This implies that thermal capacity effects may be important factors for system controls.

The Application and Evaluation of Atmospheric Dispersion Models in Pusan Area - Based on TCM2, CDM2.0, ISCLT2 - (부산지역에서의 대기확산모델의 적용 및 평가 -TCM2, CDM2.0, ISCLT2 모델을 중심으로)

  • 방종선;김유근
    • Journal of Environmental Science International
    • /
    • v.5 no.6
    • /
    • pp.699-712
    • /
    • 1996
  • For the efficient control of atmospheric quality, it is so important to predict the influence accurately of which the air pollutant emitted into the atmosphere. Atmospheric dispersion model enables to simulate and grasp the atmospheric condition occurred due to the emission of pollutants. The result of model is largely affected by the amount of emission, the characteristics of physical and chemical process, meteorological input data, and the receptor which the concentration is calculated. The aim of this research, therefore, is to suggest more suitable model in Pusan area than other areas by performing TCM2, CDM2.0 and ISCLT2 models. As the basic work for executing the model, we computed the amount of emission of air pollutants in Pusan at 1992 and analyzed the occurrence frequency of atmospheric stability for recent decade(1985~19941, CDM2.0 showed the similar result relatively with observed value in the case of full year(1992), fall and winter, and ISCLT2 brought more suitable result in spring for Pusan area. As the result of this research, in future, it is necessary for us to develop the numerical model considering the topographical characteristics, to select the proper observation site and to increase the observation site for Pusan.

  • PDF

Visualization of Roll Torque Generating Flows in a SRM Submerged-Nozzle by Cold Air-flow Test (내삽노즐 고체로켓모터의 공기 유동모사시험을 통한 롤토크 발생유동 가시화)

  • Kim, Do-Hun;Lee, In-Chul;Lee, Yeol;Koo, Ja-Ye;Kang, Moon-Jung;Kim, Yoon-Gon
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.15 no.2
    • /
    • pp.29-35
    • /
    • 2011
  • The behaviors of combustion-induced internal flows of SRM equipped with fin-slot grain and submerged nozzle are very complex and diverse. Cold air-flow tests for 2D and 3D scale models of SRM have been done in order to specify the visualization method to analyze particular internal flow patterns such as roll-torque inducing flow. Swirl flow induced by asymmetric vortical tubes also has been visualized through employing various light source and recording directions.

지하공동 모델의 전기비저항 특성에 관한 실험적 연구

  • Park, Gap-Jin;Kim, Hyeon-Su;Kim, Hyeon-Seung;Song, Yeong-Su
    • 한국지구물리탐사학회:학술대회논문집
    • /
    • 2009.10a
    • /
    • pp.93-98
    • /
    • 2009
  • Comprehension of physical properties distribution of underground cavity must be made primarily to show the clear image of the state of the cavity. A physical scale model experiment is executed assuming that underground cavity in filled with air or water of different ratio. The state of cavity wall is considered wet. Cavity model is made of agar. As a experimental result, even if the cavity wall is wet, high air and water ratio cavity shows high anomaly.

  • PDF

Evaluation of Ground Effective Thermal Conductivity and Borehole Effective Thermal Resistance from Simple Line-Source Model (단순 선형열원 모델을 이용한 지중 유효 열전도도와 보어홀 유효 열저항 산정)

  • Sohn, Byong-Hu
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.19 no.7
    • /
    • pp.512-520
    • /
    • 2007
  • The design of a ground-source heat pump system includes specifications for a ground loop heat exchanger where the heat transfer rate depends on the effective thermal conductivity of the ground and the effective thermal resistance of the borehole. To evaluate these heat transfer properties, in-situ thermal response tests on four vertical test boreholes with different grouting materials were conducted by adding a monitored amount of heat to circulating water. The line-source method is applied to the temperature rise in an in-situ test and extended to also give an estimate of borehole effective thermal resistance. The effect of increasing thermal conductivity of the grouting materials from 0.818 to $1.104W/m^{\circ}C$ resulted in overall increases in effective thermal conductivity by 15.8 to 56.3% and reductions in effective thermal resistance by 13.0 to 31.1%.