• 제목/요약/키워드: AHU

검색결과 59건 처리시간 0.025초

Preoperative Levels of Matrix Metalloproteinase-7 and -9 and Tissue Inhibitor of Matrix Metalloproteinase-1 Relation to Pathologic Parameters in Bladder Carcinoma Patients

  • Gunes, Mustafa;Kemik, Ahu Serap;Pirincci, Necip;Gecit, Ilhan;Taken, Kerem;Yuksel, Mehmet Bilgehan;Kaba, Mehmet;Eryilmaz, Recep
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제14권2호
    • /
    • pp.873-876
    • /
    • 2013
  • Our aim was to test the hypothesis that preoperative serum levels of matrix metalloproteinase-7 (MMP-7) and -9 (MMP-9) and tissue inhibitor of matrix metalloproteinase (TIMP-1) levels correlate with pathological features. Serum levels of MMP-7, and MMP-9 and TIMP-1 were determined in 90 bladder cancer patients and 40 healthy controls using an enzyme linked immunosorbent assay. Preoperative serum MMP-7 and MMP-9 levels were significantly higher in cancer patients than control groups (p<0.001). In contast, serum TIMP-1 levels were lower (p<0.001). Alteration in MMP-7, and MMP-9, and TIMP-1 production may contribute to tumor angiogenesis and be associated with clinic-pathological features.

BEMS 데이터의 통계적 분석에 기반한 공조기 최적 예냉운전 모델 개발 (Developing Optimal Pre-Cooling Model Based on Statistical Analysis of BEMS Data in Air Handling Unit)

  • 최선규;곽노열;구상헌
    • 설비공학논문집
    • /
    • 제26권10호
    • /
    • pp.467-473
    • /
    • 2014
  • Since the operating conditions of HVAC systems are different from those for which they are designed, on-going commissioning is required to optimize the energy consumed and the environment in the building. This study presents a methodology to analyze operational data and its applications. A predicted operation model is to be produced through a statistical data analysis using multiple regressions in SPSS. In this model, the dependent variable is the pre-cooling time, and the independent variables include the power output of the supply air inverter during pre-cooling, the supply air set temperature during pre-cooling, the indoor temperature-indoor set temperature just before pre-cooling, supply heat capacity, and the lowest outdoor air temperature during non-cooling/non-heating hours. The correlation coefficient R2 of the multiple regression model between the pre-cooling hour and the internal/external factors is of 0.612, and this could be used to provide information related to energy conservation and operating guidance.

빙축열을 이용한 저온공조시스템 운전 특성 연구 (Study on operation characteristics of the cold air distribution systems with an ice storage tank)

  • 염한길;박병규;고득용
    • 설비공학논문집
    • /
    • 제11권3호
    • /
    • pp.301-312
    • /
    • 1999
  • Experiments were carried out to evaluate performance of the cold air distribution systems with an ice storage tank in test room. Cold air distribution systems provide primary air for comfort conditioning or process cooling at coil discharge temperatures$4^{\circ}C$ to$11^{\circ}C$. The application of a cold air distribution system allows for the downsizing of air distribution equipment and central plant equipment when ice storage tank is used. The benefit of a cold air distribution system include a decrease in the floor-to-floor height, increase floor space, reduced building capital costs, reduced energy use and demand. The use of cold air distribution can result in the most cost effective system and is currently being implemented world wise as the new standard in air conditioning systems. In this study, the cold air distribution system is compared with the general ice storage system. Under the same cooling load conditions, experimental results show that the supply air volume of cold air distribution system decrease 38%, and decrease 45% flow rate of brine for the general ice storage system.

  • PDF

항진균성항생물질 griseofulvin 유도체인 6'-phenylgriseofulvin의 합성과 항균활성 (Synthesis and biological activity of 6'-phenylgriseofulvin as analogs of antibiotic griseofulvin)

  • 고병섭;절곡륭지;산하공평
    • Applied Biological Chemistry
    • /
    • 제35권5호
    • /
    • pp.395-398
    • /
    • 1992
  • Griseofulvin의 구조활성상관연구에서 6'-methyl기와 4'-oxo기가 생물활성에 있어서 중요한 인자라는 것이 예견되어, 6'-methyl기(基)를 phenyl기(基)로 치환한 6'-phenylgriseofulvin을 diels-alder부가환화로 합성하고 Botrytis allii 및 B. cinerea에 대한 항균활성을 paper disc 법으로 연구하였다. 6'-Phenylgriseofulvin은 $25\;{\mu}g/disc$에서 높은 항균활성을 나타냈다.

  • PDF

공기조화기 장착용 축상유입식 싸이클론의 입자제거효율에 대한 실험적 연구 (Experimental Study on Particle Collection Efficiency of Axial-flow Cyclone in Air Handling Unit)

  • 김세영;권순박;박덕신;조영민;김진호;김명준;김태성
    • 한국대기환경학회지
    • /
    • 제27권3호
    • /
    • pp.272-280
    • /
    • 2011
  • A novel particle removal system for air handling unit (AHU) of subway station was evaluated experimentally. The novel system was designed in order to minimize the maintenance cost by applying axial-flow cyclones. The system consists of multiple cyclone units and dust trap. Based on our previous numerical study, it was found to be effective for removal $1\sim10{\mu}m$ sized dust particles. In this study, we manufactured the mock-up model and evaluated the model experimentally. Liquid and solid test particles were generated for evaluating collection efficiency of the system and the pressure drop was monitored. The collection efficiency was varied from 41.2% to 85.9% with increasing the sizes of particle from 1 to $6.5{\mu}m$ by particle count ratio of inlet and outlet. The pressure drop was maintained constant less than $20mmH_2O$. In addition, the collection efficiency was estimated by total mass for solid test particles. It was found that the collection efficiency was 65.7% by particle mass ratio of inlet and outlet. It shows that present system can replace current pre-filters used in subway HVAC system for removing particulate matters with minimal operational cost.

撒水濾床法에 依한 畜産廢水의 處理效果에 관한 연구 (Efficiency of Livestock Farming Wastewater Treatment by Trickling Filters)

  • Ahu, Soo Mi
    • 한국환경보건학회지
    • /
    • 제11권2호
    • /
    • pp.17-27
    • /
    • 1985
  • The objectives of this study is to examine efficiency of swinery wastewater treatment by trickling filters' pilot plant. The results of this study are as follows: 1. The characteristics of sample. The BOD$_5$ was from 2,450 to 2,880mg/l, COD(KMnO$_4$ acid method) was from 910 to 1,064mg/l, and SS was from 920 to 990mg/l. The pH of influent was from 7.3 to 7.6, and the temperature of water was from 17.0$\circ$C to 22.5$\circ$C. 2. For experiment by recirculation, the BODs removal efficiency is 65.2% at recirculation ratio (r)=0, and 70.7% at r=1. The ramoval efficiency of this study is higher than NRC formula of U.S.A.. The recirculation is not significant effect on removal efficiency. 3. For experiment by hydraulic load, the BOD$_5$ removal rate decreased from 73.1% at $3.1m^3/m^2\cdot d$ to 65.3% at $9.2m^3/m^2\cdot d$. The design formula of this study which shows the removal rate of soluble BOD is $Le/Li =10^{-0.24} D/Q^{0.24}$ (Q: hydraulic load, D: depth of filter). 4. For experiment by organic load, the BOD$_5$ removal rate is increased from 70.2% at $0.77kg/m^3\cdot d$ to 75.4% at $4.28kg/m^3\cdot d$. We can obtain the straight line y=0.749 x (y: removed BOD, x :applied BOD) by the least squares method. 5. We can know that trickling filters is strong with the hydraulic load and the organic matter shock load. Here, we can judge that trickling filters is a good method for the treatment of swinery wastewater which containing high concentrated organic matter.

  • PDF

Investigation of bacteremia after toothbrushing in orthodontic patients

  • Hussein, Emad Ahmad;Acar, Ahu;Dogan, Alev Aksoy;Kadir, Tanju;Caldemir, Seniz;Erverdi, Nejat
    • 대한치과교정학회지
    • /
    • 제39권3호
    • /
    • pp.177-184
    • /
    • 2009
  • Objective: The aim of this study was to investigate the occurrence rate of bacteremia following toothbrushing with toothpastes composed of several antibacterial agents and compare the results with the conventional oral hygiene maintaining methods in orthodontic patients. Methods: This clinical study included 100 adult orthodontic patients who were divided into 4 groups. Each group comprised of 25 patients, wearing fixed orthodontic appliances. In the first group, bacteremia was assessed after toothbrushing without using any toothpaste. In the second group, a 0.2% chlorhexidine gluconate mouthrinse was used before brushing with no toothpaste. In the third group, subjects brushed with a commonly used toothpaste which did not include an additional antimicrobial agent. The fourth experimental group used toothpaste which included tea tree oil, clove oil, peppermint oil and bisabolol as antimicrobial elements. Pre- and post-brushing blood samples were obtained using a strict aseptic technique. All samples were microbiologically evaluated using blood culture bottles. Results: Toothbrushing in orthodontic patients yielded to an increase in the occurrence rate of bacteremia when using normal toothpaste or no toothpaste at all. Conclusions: The use of chlorhexidine mouthwash before toothbrushing, and brushing with antimicrobial toothpaste did not show a statistically significant difference in preventing the occurrence of bacteremia (p > 0.05).

Gingival crevicular fluid CSF-1 and IL-34 levels in patients with stage III grade C periodontitis and uncontrolled type 2 diabetes mellitus

  • Ahu Dikilitas;Fatih Karaaslan;Sehrazat Evirgen;Abdullah Seckin Ertugrul
    • Journal of Periodontal and Implant Science
    • /
    • 제52권6호
    • /
    • pp.455-465
    • /
    • 2022
  • Purpose: Periodontal diseases are inflammatory conditions that alter the host's response to microbial pathogens. Type 2 diabetes mellitus (T2DM) is a complex disease that affects the incidence and severity of periodontal diseases. This study investigated the gingival crevicular fluid (GCF) levels of colony-stimulating factor-1 (CSF-1) and interleukin-34 (IL-34) in patients with stage III grade C periodontitis (SIII-GC-P) and stage III grade C periodontitis with uncontrolled type 2 diabetes (SIII-GC-PD). Methods: In total, 72 individuals, including 24 periodontally healthy (PH), 24 SIII-GC-P, and 24 SIII-GC-PD patients, were recruited for this study. Periodontitis patients (stage III) had interdental attachment loss (AL) of 5 mm or more, probing depth (PD) of 6 mm or more, radiographic bone loss advancing to the middle or apical part of the root, and tooth loss (<5) due to periodontal disease. Radiographic bone loss in the teeth was also evaluated; grade C periodontitis was defined as a ratio of the percentage of root bone loss to age greater than 1.0. The plaque index (PI), gingival index (GI), presence of bleeding on probing (BOP), PD, and clinical AL were used for clinical periodontal assessments. GCF samples were obtained and analyzed using an enzyme-linked immunosorbent assay. Results: All clinical parameters-PD, AL, GI, BOP, and PI-were significantly higher in the SIII-GC-PD group than in the PH and SIII-GC-P groups for both the full mouth and each sampling site (P<0.05). The total IL-34 and CSF-1 levels were significantly higher in the SIII-GC-PD group than in the PH and SIII-GC-P groups (P<0.05), and there were significant differences between the periodontitis groups (P<0.05). Conclusions: These findings suggest that IL-34 and CSF-1 expression increases in patients with SIII-GC-PD. CSF-1 was associated with the inflammatory status of periodontal tissues and T2DM, while IL-34 was associated only with T2DM.

식생기반 바이오필터의 미세먼지, 이산화탄소 개선효과와 실내쾌적지수 분석 (Particulate Matter and CO2 Improvement Effects by Vegetation-based Bio-filters and the Indoor Comfort Index Analysis)

  • 김태한;최부헌;최나현;장은숙
    • 한국환경농학회지
    • /
    • 제37권4호
    • /
    • pp.268-276
    • /
    • 2018
  • 본 연구는 일반인에게 안전한 실내공기질 개선수단으로 인식되는 공기정화식물의 효율적 적용을 위해 실내공조에 요구되는 총풍량 확보가 가능한 식생기반 바이오필터 시스템을 제안하고자 했다. 시스템의 정량적 성능평가는 강의실형태의 실험실 체적 $332.73m^3$ 내 16명의 재실자 조건에서 목업단위 시스템의 공조 성능, 실내공기질 및 쾌적지표 개선효과에 대한 시계열 분석으로 진행되었다. 우선, 시스템 구동을 통해 총 $1,411.22m^3/h$의 유출 총풍량을 확보하여, 4.24 ACH의 환기율을 제공할 수 있었다. 실내온도는 $1.6^{\circ}C$, 흑구온도는 $1.0^{\circ}C$ 감소가 확인되었으며, 상대습도는 24.4% 상승한 최대 82.0%까지 증가하였다. 상대습도 급증에 따른 쾌적도 감소현상은 송풍기 구동에 따라 발생되는 실내기류로 상쇄되는 것으로 판단된다. 또한, 시스템 가동에 따른 공기질 개선지표 중 $PM_{10}$은 39.5% 감소한 평균 $22.11{\mu}g/m^3$을 기록하였다. 반면, $CO_2$는 최대 1,329 ppm까지 지속적으로 농도가 상승했는데, 이는 광도조건이 광보상점을 만족하지 못해 적용 식물과 재실자에서 방출되는 $CO_2$가 처리되지 못한 것으로 해석된다. 실내쾌적지표의 경우 PMV는 평균 83.6 % 감소된 -0.082, PPD는 평균 47.0% 감소된 5.41%에 수렴하여 식생기반 바이오필터 구동에 의해 높은 쾌적범위의 실내공간조성이 가능한 것으로 판단되었다. 본 연구의 한계는 소수 참여인원과 단기간 실험으로 인하여 시스템의 성능 규명이 제한적인 부분이었으며, 보다 장기간의 실험을 통해 바이오필터에 도입된 식생의 생육상태에 따른 압력손실 변화, 미세먼지 저감에 대한 구체적인 메커니즘 규명 등의 후속연구가 진행되어야 할 것이다.