• 제목/요약/키워드: AGC(Automatic Generation Control) system

검색결과 23건 처리시간 0.026초

AGC 운용에 있어서의 원격 On-line 최대 증감발율 취득 기법 (Remote On-line Determination of the Load Rate Limit of Generation in AGC)

  • 권순만;전동훈;문원용;김석주
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 추계학술대회 논문집 학회본부 A
    • /
    • pp.119-121
    • /
    • 2000
  • The possibility of a remote on-line determination of the maximum load rates that are basically set at generation plants is investigated in automatic generation control (AGC) system. Energy management system (EMS) generates a test input to a remote power plant to get the samples of the generator output. Then from the samples it can be attempted to determine an approximate value of the load rate limit set by the operator. It is shown in computer simulation that in actual power plants the limit can be approximately determined from the input-output characteristics of the plants for a unit-step input.

  • PDF

3GPP LTE FDD/TDD 듀얼 모드 하향 링크 수신기의 초기 셀 탐색을 위한 개선된 AGC 구조 및 P-SCH 검출 기법 (An Enhanced AGC Structure and P-SCH Detection Method for Initial Cell Search in 3GPP LTE FDD/TDD Dual Mode Downlink Receiver)

  • 정명진;장준희;최형진
    • 한국통신학회논문지
    • /
    • 제35권3C호
    • /
    • pp.302-313
    • /
    • 2010
  • 본 논문에서는 3GPP(3rd Generation Partnership Project) LTE(Long Term Evolution) FDD(Frequency Division Duplexing)/TDD(Time Division Duplexing) 듀얼 모드 하향 링크 수신기의 초기 셀 탐색 (Initial Cell Search)을 위한 개선된 AGC (Automatic Gain Control) 구조 및 P-SCH (Primary Synchronization Channel) 검출 기법을 제안한다. 주파수 분할을 통하여 양방향 송수신되는 FDD 모드와 달리 TDD 모드에서는 상향링크(Uplink) 구간과 하향링크 구간이 시분할로 전송되기 때문에 일반적인 AGC 구조를 고려 시 TDD 모드에서는 AGC variation의 증가로 인한 P-SCH 검출 성능 열화를 유발하게 된다. 또한 주파수 옵셋 및 다중 경로 페이딩의 영향 역시 P-SCH 상관 과정에서의 상관 특성을 왜곡시켜 P-SCH 검출 성능 열화를 유발하게 된다. 따라서, 본 논문에서는 FDD 모드에서뿐 아니라, TDD 모드에서도 안정적인 동작을 보장함으로써 AGC 동작에 의한 P-SCH 검출 성능 열화를 최소화할 수 있는 AGC 구조를 제안하며, 또한 주파수 옵셋이 존재하는 환경 및 다중 경로 페이딩 환경에서의 상관 특성 열화로 인한 P-SCH 검출 성능 열화를 최소하기 위한 개선된 P-SCH 검출 기법도 제안한다. 다양한 환경에서 제안된 AGC 구조와 P-SCH 검출 기법의 성능 검증을 통해 제안된 방식이 FDD/TDD 듀얼 모드 하향 링크 수신기에서 안정적인 AGC 동작 및 P-SCH 검출 성능의 보장이 가능함을 입증하였다.

원격 급전소에서 발전소 출력을 제어하기 위한 시스템 연구 (A study on the remote MW control of a steam turbine)

  • 김종안;신윤오
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 B
    • /
    • pp.734-736
    • /
    • 1999
  • The electricity demand has been in the trend of increase for the past 30 years except last year due to economic crisis. The central electrical power dispatch center anticipates each and every hour's electricity demand and dispatch every power plant's output(MW) taking into account of the costs, frequency regulation abilities, locations, reliabilities and so on. to meet the demand as quickly as possible. The large portion of the power plants' output is contolled automatically by the AGC(Automatic Generation Control) function which is a part of the EMS(Energy Manage System) computer in the dispatch center. To receive the electrical power dispatch signal from the EMS, a power plant should have a remote MW control feature in the turbine control system or unit master control system. We investigated the AGC function and a power plant's remote MW control configuration.

  • PDF

Probabilistic Load Flow for Power Systems with Wind Power Considering the Multi-time Scale Dispatching Strategy

  • Qin, Chao;Yu, Yixin;Zeng, Yuan
    • Journal of Electrical Engineering and Technology
    • /
    • 제13권4호
    • /
    • pp.1494-1503
    • /
    • 2018
  • This paper proposes a novel probabilistic load flow model for power systems integrated with large-scale wind power, which considers the multi-time scale dispatching features. The ramp limitations of the units and the steady-state security constraints of the network have been comprehensively considered for the entire duration of the study period; thus, the coupling of the system operation states at different time sections has been taken into account. For each time section, the automatic generation control (AGC) strategy is considered, and all variations associated with the wind power and loads are compensated by all AGC units. Cumulants and the Gram-Charlier expansion are used to solve the proposed model. The effectiveness of the proposed method is validated using the modified IEEE RTS 24-bus system and the modified IEEE 118-bus system.

자동발전제어(AGC) 운용기선에 관한 연구 (A study on Improvement of Automatic Generation Control Related Systems for New Energy Management System)

  • 전동훈;추진부;윤용범;김성학;이진수;김국헌;권순만
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 A
    • /
    • pp.357-359
    • /
    • 2000
  • This paper is to introduce the R&D project called "Improvement of Automatic Gene-ration Control Related Systems for New Energy Management system". The principal objective of this project is to demonstrate AGC operation capabilities that are suitable to new EMS environment and to show the validity of Set-Point Control Method. A number of developments and enhancements have been made to the generator's Remote Terminal Unit in which new ASTC is being developed and installed. The so-called ACC Signal Transfer Card(ASTC) will include RTU's Set-Point Control capabilities. It is expected that over next few months both RTU & DCS software modifications will be given and a relatively new Set-Point Control Method will be chosen instead of those from more conventional method, pulse control method.

  • PDF

터빈-발전기 조속기의 동특성 시험시스템 개발에 관한 연구 (A study on the Turbine-Generator Governor Dynamic Characteristic Testing System)

  • 최형주;이흥호
    • 전기학회논문지
    • /
    • 제61권10호
    • /
    • pp.1399-1411
    • /
    • 2012
  • The grid frequency is controlled cooperatively by the governor of the Turbine-Generator and the automatic generation controller(AGC) of the KPX(Korea Power Exchange). It is a basic requirement that the reliability of the governor is verified to enhance the power system stability but it is not easy to confirm the response characteristics of the governor because all generators are operated in the grid system that has the constant voltage and frequency. Therefore, it is necessary to study a new test method in order to examine the governor dynamic characteristic in the similar fault conditions. A study has shown that it is verified to simulate the turbine-generator power control system, the governor response characteristic under limited conditions and contribution of AGC with the gas turbine generator simulation model as well as demonstrate the dynamic response of the governor with the developed governor dynamic characteristic tester based on digital controller while the turbine-generator is connected to the grid system. This tester is constructed by the built-in functions of the turbine-generator main controller. In this treatise, the theoretical background, development method and the results of both simulations and demonstrations are described as another way to verify the turbine-generator governor dynamic characteristics.

주파수조정용 ESS의 성능검증 및 경제성평가 알고리즘에 관한 연구 (A Study on The Performance Verification and Economic Evaluation of ESS for Frequency Regulation Application)

  • 이주광;최성식;강민관;노대석
    • 한국산학기술학회논문지
    • /
    • 제18권5호
    • /
    • pp.738-744
    • /
    • 2017
  • 최근 신재생에너지의 확대 보급과 더불어 전기저장장치(ESS, Energy Storage System)가 활발하게 도입되고 있다. 하지만 현재 전기저장장치에 대한 도입효과와 경제성 및 계통에 미치는 영향에 대한 구체적인 평가방법이 없어 효과적인 도입운용이 어려운 실정이다. 특히 주파수조정용 ESS에 대한 국제적인 기술표준 및 제도가 마련되지 않아, 이의 설치에 따른 전기품질, 계통영향, 기여도 등은 물론 편익 산정에 대한 종합적인 연구가 필요한 실정이다. 따라서 본 논문에서는 주파수조정용 ESS의 성능검증 방안을 마련하기 위하여, 기존발전기의 주파수조정 성능평가 방법인 미국 PJM의 AGC(Automatic Generation Control, 발전기 자동발전제어) 성능 평가방식을 분석하여, 주파수조정용 ESS의 성능평가 알고리즘을 제안하였고, 고가발전기의 정산금과 화력발전기의 정산금을 이용하여 500MW급의 주파수조정용 ESS의 도입에 따른 편익을 산정할 수 있는 경제성 평가 알고리즘을 제시하였다. 제안한 알고리즘의 유용성을 확인하기 위하여, 실 계통 데이터를 바탕으로 시뮬레이션을 수행한 결과, 전기저장장치가 기존의 발전기에 비하여 아주 우수한 성능을 가지고 있음을 확인하였고, 500MW 도입시 연간 약 3,457~4,296억의 편익이 발생함을 확인하였다.

MOBA based design of FOPID-SSSC for load frequency control of interconnected multi-area power systems

  • Falehi, Ali Darvish
    • Smart Structures and Systems
    • /
    • 제22권1호
    • /
    • pp.81-94
    • /
    • 2018
  • Automatic Generation Control (AGC) has functionally controlled the interchange power flow in order to suppress the dynamic oscillations of frequency and tie-line power deviations as a perturbation occurs in the interconnected multi-area power system. Furthermore, Flexible AC Transmission Systems (FACTS) can effectively assist AGC to more enhance the dynamic stability of power system. So, Static Synchronous Series Compensator (SSSC), one of the well-known FACTS devices, is here applied to accurately control and regulate the load frequency of multi-area multi-source interconnected power system. The research and efforts made in this regard have caused to introduce the Fractional Order Proportional Integral Derivative (FOPID) based SSSC, to alleviate both the most significant issues in multi-area interconnected power systems i.e., frequency and tie-line power deviations. Due to multi-objective nature of aforementioned problem, suppression of the frequency and tie-line power deviations is formularized in the form of a multi-object problem. Considering the high performance of Multi Objective Bees Algorithm (MOBA) in solution of the non-linear objectives, it has been utilized to appropriately unravel the optimization problem. To verify and validate the dynamic performance of self-defined FOPID-SSSC, it has been thoroughly evaluated in three different multi-area interconnected power systems. Meanwhile, the dynamic performance of FOPID-SSSC has been accurately compared with a conventional controller based SSSC while the power systems are affected by different Step Load Perturbations (SLPs). Eventually, the simulation results of all three power systems have transparently demonstrated the dynamic performance of FOPID-SSSC to significantly suppress the frequency and tie-line power deviations as compared to conventional controller based SSSC.

PID Control with Fuzzy Compensation for Electric Power Generation Unit

  • Kim, Seung-Cheol;Cho, Yong-Sung;Park, Jae-Hyung;Lim, Young-Do;Lee, Ihn-Yong
    • 한국지능시스템학회:학술대회논문집
    • /
    • 한국퍼지및지능시스템학회 2003년도 ISIS 2003
    • /
    • pp.326-329
    • /
    • 2003
  • Controller that is designed in this paper is form that apply PID controller about Fuzzy algorithm. Fuzzy Controller that using this paper is can speak that compensation style fuzzy controller as form to solidify action of PID controller for plant. This is not form that autotuning the each PID coefficient. We Apply and examined the response character to AGC(Automatic Generation Control) system using designed controller.

  • PDF

속응자원의 국내 및 북미 ISO/RTO 주파수조정예비력 서비스 제공에 따른 보상규칙 비교 분석 (Comparison of Compensation Rules for Fast Responding Resources Providing Frequency Regulation Service in Domestic and North American ISO/RTO Power Electricity Market)

  • 박대현;박용기;박종배;김발호;노재형
    • 전기학회논문지
    • /
    • 제67권5호
    • /
    • pp.617-625
    • /
    • 2018
  • Since FERC order 755 was published, each frequency regulation market rules of the North American ISO/RTO have been revised in many parts. In 2016, the domestic CBP market has also changed its market rules to allow ESS to participate in the frequency regulation reserve services(Governor Free and Automatic Generation Control). This paper compares and analyzes the changed North American ISP/RTO market and domestic CBP market rules. In particular, we compare PJM and CAISO frequency regulation market pricing mechanism and settlement rules with the settlement rules of the domestic CBP market and compare the factors of each market used to compensate the participating resources in terms of resource dependency and accuracy.