• Title/Summary/Keyword: AE Parameters

Search Result 419, Processing Time 0.029 seconds

Study on the Real-Time Leak Monitoring Technique for Power Plant Valves (발전용 밸브누설 실시간 감시기술 연구)

  • Lee, S.G.
    • Journal of Power System Engineering
    • /
    • v.11 no.1
    • /
    • pp.39-44
    • /
    • 2007
  • The purpose of this study is to verify availability of the acoustic emission in-situ monitoring method to the internal leak and operating conditions of the major valves at nuclear power plants. In this study, acoustic emission tests are performed when the pressurized temperature water and steam flowed through glove valve(main steam dump valve) and check valve(main steam outlet pump check valve) on the normal size of 12 and 18". The valve internal leak monitoring system for practical field was designed. The acoustic emission method was applied to the valves at the site, and the background noise was measured for the abnormal plant condition. To improve the reliability, a judgment of leak on the system was used various factors which are AE parameters, trend analysis, frequency analysis, voltage analysis and amplitude analysis of acoustic signal emitted from the valve operating condition internal leak.

  • PDF

Development of 7-Year-Old Korean Child Model for Computational Dosimetry

  • Lee, Ae-Kyoung;Byun, Jin-Kyu;Park, Jin-Seo;Choi, Hyung-Do;Yun, Jae-Hoon
    • ETRI Journal
    • /
    • v.31 no.2
    • /
    • pp.237-239
    • /
    • 2009
  • A whole-body voxel model of a 7-year-old male volunteer was developed from 384 axial magnetic resonance images (MRIs). The MRIs were acquired with intervals of 3 mm for the entire body in a body coil. In order to reduce the MRI acquisition time for the child, the repetition and echo times under T1 weighted image were chosen to be 566 ms and 8 ms, respectively. The MRIs were classified according to 30 types of tissues with known electrical parameters. The developed voxel model was adjusted to the physical average of 7-year-old Korean boys. The body weight of the adjusted model, calculated with the mass tissue densities, is within a 6% difference from the 50th percentile weight.

  • PDF

Photoactivity of $TiO_2$-coated Bead for Organic Contaminants in Photocatalytic System (광촉매 시스템을 이용한 $TiO_2$ 코팅비드의 광분해 활성)

  • Park, Seong-Ae;Do, Young-Woong;Ha, Jin-Wook
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.8 no.6
    • /
    • pp.1579-1582
    • /
    • 2007
  • The purpose of this study is to compare degrading performance of organic contaminants in aqueous solution using photocatalyst and find an optimal condition for decomposing non-degradable matters. The parameters of this research is light intensity and state of photocatalytic material within reactor. The results showed that Type 3 (terms of plastic beads : $500^{\circ}C$, 3hr) has the greatest reactivity.

  • PDF

A Review of Power and Sample Size Estimation in Genomewide Association Studies (유전체 연관 연구에서의 검정력 및 연구대상수 계산 고찰)

  • Park, Ae-Kyung;Kim, Ho
    • Journal of Preventive Medicine and Public Health
    • /
    • v.40 no.2
    • /
    • pp.114-121
    • /
    • 2007
  • Power and sample size estimation is one of the crucially important steps in planning a genetic association study to achieve the ultimate goal, identifying candidate genes for disease susceptibility, by designing the study in such a way as to maximize the success possibility and minimize the cost. Here we review the optimal two-stage genotyping designs for genomewide association studies recently investigated by Wang et al(2006). We review two mathematical frameworks most commonly used to compute power in genetic association studies prior to the main study: Monte-Carlo and non-central chi-square estimates. Statistical powers are computed by these two approaches for case-control genotypic tests under one-stage direct association study design. Then we discuss how the linkage-disequilibrium strength affects power and sample size, and how to use empirically-derived distributions of important parameters for power calculations. We provide useful information on publicly available softwares developed to compute power and sample size for various study designs.

Application of QuickBird Satellite Image to Storm Runoff Modeling

  • Kim, Sang-Ho;Lee, Mi-Seon;Park, Geun-Ae;Kim, Seong-Joon
    • Korean Journal of Remote Sensing
    • /
    • v.23 no.1
    • /
    • pp.15-20
    • /
    • 2007
  • This study is to apply QuickBird satellite image for the simulation of storm runoff in a small rural watershed. For a $1.05km^2$ watershed located in Goesan-Gun of Chungbuk Province, the land use from the QuickBird image was produced by on-screening digitising after ortho-rectifying using 2 m DEM. For 3 cases of land use, soil and elevation scale (1:5,000, 1:25,000 and 1:50,000), SCS-CN and the watershed physical parameters were prepared for the storm runoff model, HEC-HMS (Hydrologic Modelling System). The model was evaluated for each case and compared the simulated results with couple of selected storm events.

Hydrogen Bonding between Thioacetamide and Some N,N-dimethylalkylamides in Chloroform

  • Park, Hee-Suk;Choi, Jae-Young;Kim, Yong-Ae;Huh, Young-Duk;Yoon, Chang-Ju;Choi, Young-Sang
    • Bulletin of the Korean Chemical Society
    • /
    • v.11 no.5
    • /
    • pp.367-371
    • /
    • 1990
  • The near-IR spectra of thioacetamide were recorded for the investigation of hydrogen bonding between thioacetamide (TA) and N,N-dimethylalkylamides (DMF, DMA, DMP) in chloroform over the range of 5$^{\circ}C$ to 55$^{\circ}C$. The ${\nu}_{\alpha}$ + amide II combination band has been resolved into contributions from monomeric TA, 1:1 hydrogen bonded complex and 1:2 complex by the parameterized matrix modeling method. The association constants ($K_c$) of the complex have been obtained at various temperatures and used to determine the thermodynamic parameters for the hydrogen bonding by the usual Van't Hoff method. It was found that N,N-dimethylalkylamide forms less stable hydrogen bonded complex with TA in chloroform than in carbon tetrachloride.

A Case Report of Inter-expert Cooperation Strategy for Increasing Community Ambulation in Stroke Patient (뇌졸중 환자의 지역사회 보행능력 증진을 위한 동일 전문가 간 협력 사례)

  • Cho, Hyuk-Shin;Chung, Hyun-Ae
    • PNF and Movement
    • /
    • v.9 no.3
    • /
    • pp.41-48
    • /
    • 2011
  • Purpose : The purpose of this study was to describe the Inter-expert cooperation strategy for community ambulation in stroke patient. Methods : The data was collected by stroke patient. We applied the Inter-expert cooperation strategy for community ambulation to stroke patient. Parameters of result were collected for using the 10m walk test, 6 minute walk test and ICF assessment sheet. Results : Significant differences were observed the stroke patient for 10m walk test, 6 minute walk test and ICF assessment sheet. stroke patient improved all test. Conclusions : Inter-expert cooperation strategy applied community ambulation is very useful and effective. It is effective in clinical practice.

The Effect of Gaze Angle on Muscle Activity and Kinematic Variables during Treadmill Walking

  • Kim, Bo-Suk;Jung, Jae-Hu;Chae, Woen-Sik
    • Korean Journal of Applied Biomechanics
    • /
    • v.27 no.1
    • /
    • pp.35-43
    • /
    • 2017
  • Objective: The purpose of this study was to determine how gaze angle affects muscle activity and kinematic variables during treadmill walking and to offer scientific information for effective and safe treadmill training environment. Method: Ten male subjects who have no musculoskeletal disorder were recruited. Eight pairs of surface electrodes were attached to the right side of the body to monitor the upper trapezius (UT), rectus abdominis (RA), erector spinae (ES), rectus femoris (RF), bicep femoris (BF), tibialis anterior (TA), medialis gastrocnemius (MG), and lateral gastrocnemius (LG). Two digital camcorders were used to obtain 3-D kinematics of the lower extremity. Each subject walked on a treadmill with a TV monitor at three different heights (eye level; EL, 20% above eye level; AE, 20% below eye level; BE) at speed of 5.0 km/h. For each trial being analyzed, five critical instants and four phases were identified from the video recording. For each dependent variable, one-way ANOVA with repeated measures was used to determine whether there were significant differences among three different conditions (p<.05). When a significant difference was found, post hoc analyses were performed using the contrast procedure. Results: This study found that average and peak IEMG values for EL were generally smaller than the corresponding values for AE and BE but the differences were not statically significant. There were also no significant changes in kinematic variables among three different gaze angles. Conclusion: Based on the results of this study, gaze angle does not affect muscle activity and kinematic variables during treadmill walking. However, it is interesting to note that walking with BE may increase the muscle activity of the trapezius and the lower extremity. Moreover, it may hinder proper dorsiflexion during landing phase. Thus, it seems to reasonable to suggest that inappropriate gaze angle should be avoided in treadmill walking. It is obvious that increased walking speed may cause a significant changes in biomechanical parameters used in this study. It is recommended that future studies be conducted which are similar to the present investigation but using different walking speed.

자기폭풍예보모델을 이용한 우주환경예보

  • 안병호
    • Information and Communications Magazine
    • /
    • v.15 no.9
    • /
    • pp.97-106
    • /
    • 1998
  • It is crucial to predict the variabilities of the near-earth space environment associated with the solar activity, which cause enormous socio-economic impacts on mankind. The geomagnetic storm prediction scheme adopted in this study is designed to predict such variabilities in terms of the geomagnetic indices, AE and Dst, the cross-polar cap potential difference, the energy dissipation rate over the polar ionosphere and associated temperature increase in the thermosphere. The prediction code consists of two parts; prediction of the solar wind and interplanetary magnetic field based upon actual flare observations and estimation of various electrodynamic quantities mentioned above from the solar wind-magnetosphere coupling function 'epsilon' which is derivable through the predicted solar wind parameters. As a test run, the magnetic storm that occurred in early November, 1993, is simulated and the results are compared with the solar wind and the interplanetary magnetic field measured by the Japanese satellite, Geotail, and the geomagnetic indices obtained from ground magnetic observatories. Although numerous aspects of the code are to be further improved, the comparison between the simulated results and the actual measurements encourages us to use this prediction scheme as the first appoximation in forecasting the disturbances of the near-earth space environment associated with solar flares.

  • PDF

Nondestructive Damage Sensitivity of Carbon Nanotube and Nanofiber/Epoxy Composites using Electro- Micromechanical Technique and Acoustic Emission (전기적-미세역학 시험법과 음향 방출을 이용한 탄소 나노튜브와 나노섬유 강화 에폭시 복합재료의 비파괴 손상 감지능)

  • 김대식;박종만;김태욱
    • Polymer(Korea)
    • /
    • v.28 no.4
    • /
    • pp.285-290
    • /
    • 2004
  • Nondestructive damage sensitivity of carbon nanotube(CNT) and nanofiber (CNF)/epoxy composites with their adding contents was investigated using electro-micromechanical technique. Carbon black (CB) was used only for the comparison with CNT and CNF. The fracture of carbon fiber was detected by acoustic emission (AE), which was correlated to the change in electrical resistance, ΔR under double-matrix composites (DMC) test. Stress sensing on carbon nanocomposites was performed by electro-pullout test under uniform cyclic loading. At the same volume fraction, the damage sensitivity for fiber fracture, matrix deformation and stress sensing were highest for CNT/epoxy composite, whereas for CB/epoxy composite they were the lowest among three carbon nanomaterials (CNMs). Damage sensitivity was correlated with morphological observation of carbon nanocomposites. Homogeneous dispersion among CNMs could be keying parameters for better damage monitoring. In this study, damage sensing of carbon nanocomposites could be evaluated well nondestructively by the electrical resistance measurement with AE.