• Title/Summary/Keyword: ADU

Search Result 63, Processing Time 0.021 seconds

A study on Changes in ADL Functioning of Residents in Taejon City (가정간호환자의 일상생활작동수행능력 변화에 대한 연구)

  • Choi, Myoung-Han
    • Journal of Korean Academic Society of Home Health Care Nursing
    • /
    • v.4
    • /
    • pp.53-64
    • /
    • 1997
  • This study was done to investigate the ADL differences between before and after home care. For this survey, the Barthel index, an ADU(activities of daily living) assessment, and general history questions were asked. Functional performance, i.e. ADL, was studied in a population a total of 56 men and women aged 65 and older from the city of Taejon. Among the independent subjects, women, 73 years of age and older, married status, 1-2 times taking home care per month, the case answering 'Quite' about satisfactory of home care, elderly dwelling with others and who have helper and spouse, elderly having a snack regularly, are statistically significant. Also ADL differences were found in grooming, getting in and out chair, getting on and off toilet, walking 500 meters on the level. Further studies should evaluate the activities of daily living to predict important disability-related outcomes.

  • PDF

Curing characteristics of the Photocurable Resin for Fabrication of Micro-structures with overhang shape (돌출 형상을 가진 마이크로 구조물 가공을 위한 광경화성 수지의 경화 특성)

  • Jeoung M.G.;Choi J.W.;Ha Y.M.;Lee S.H.;Kim H.C.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2006.05a
    • /
    • pp.491-492
    • /
    • 2006
  • In the microstereolithography which can make 3-D microstructures, curing depth is different according to exposure energy. Curing depth has to be controlled to fabricate complex 3-D microstructures with overhang shape. It becomes increases when the exposure energy increases. And photocurable resin is cured when the exposure energy is bigger than critical energy. So optimal exposure energy has to be found to fabricate overhang structures without being gel. To make thinner layer, UV absorber is used and exposure pattern is changed. In this paper, we find curing characteristics according to exposure energy, and fabricate microstructures with overhang shape.

  • PDF

Development of the Alarm Monitoring System for KNPEC-2 (원자력교육원 2호기 시뮬레이터 경보감시계통 개발)

  • 홍진혁
    • Proceedings of the Korea Society for Simulation Conference
    • /
    • 1999.10a
    • /
    • pp.156-162
    • /
    • 1999
  • 원자력교육원 2회기 기준발전소인 영광 1호기 발전소의 디지털 경보설비 (IAS : Intelligent Annunciator System) 는 MPU, SSU, ACU 및 ADU로 구성되어 있으며, 특히 MPU에서는 SSU 로부터 수신된 Scan Data를 해석하고 경보를 저장하고, 경보의 내용을 프린터 및 CRT를 비롯하여 다양한 형태로 병렬출력이 가능하도록 하고 있다. 본 논문에서는 전력연구원에서 수행중인 '원자력 교육원 시뮬레이터 성능개선' 과제의 일부로 IAS의 구조와 이를 시뮬레이터 주컴퓨터 (Host Computer)상의 다이나믹 모델과 연동시켜 구현하는 방법론을 다루고 있다. 특히, 시뮬레이터에 대한 규제기관의 인허가가 중요한 현안으로 대두될 전망임에 따라 ANSI/ANS-3.5, Regulatory Guide 1.149 등 규제요건에서 제시하는 성능기준 및 검사기준을 만족하도록 설계함으로 향후 규제기관에 대한 인허가 획득에서 대비할 예정이다.

  • PDF

The Design and Implementation of RapidPLUS Based Virtual Prototyping for Multimedia Player (멀티미디어 플레이어를 위한 RapidPLUS 기반 가상 프로토타이핑 설계 및 구현)

  • Adu, Emmanuel;Ahn, SungSoon;Lee, Jeong B.;Choi, SungHee
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2010.04a
    • /
    • pp.64-67
    • /
    • 2010
  • 프로토타이핑 시스템 설계에서 프로토타이핑은 실제 모델과 같은 초기 모형을 뜻하는 것으로 개발 초기에 시스템의 모형을 간단히 만들어 사용자에게 제시하여 사용자로 하여금 실제 작동시켜 기능의 추가, 변경 내지 삭제를 요구하도록 하여 시스템을 점차적으로 개선시켜 나가도록 하는 방식을 말한다. 가상 프로토타이핑은 임베디드 소프트웨어 개발 초기단계에서 사용자 혹은 의뢰자의 요구사항들을 효과적으로 추출할 수 있도록 고안된 시스템 요구 및 제약조건 추출 방법론이다. 본 논문에서는 가상 프로토타이핑 기법을 이용하여 멀티미디어 플레이어의 다양한 기능을 시뮬레이션 할 수 있는 가상 프로토타입을 설계 및 구현한다.

Electrolytic Decontamination of the Dismantled Metallic Wastes Contaminated with Uanium Compounds in Neutral Salt Solutions (중성염 용액 내에서 우라늄으로 오염된 금속성 해체폐기물의 전해제염)

  • 최왕규;이성렬;김계남;원휘준;정종헌;오원진
    • Proceedings of the Korean Radioactive Waste Society Conference
    • /
    • 2004.06a
    • /
    • pp.72-80
    • /
    • 2004
  • Electrolytic dissolution study was carried out to evaluate the applicability of electrochemical decontamination process using a neutral salt electrolyte as a decontamination technology for the recycle or self disposal with authorization of large amount of metallic wastes contaminated with uranium compounds generated by dismantling a retired uranium conversion plant using SUS-304 and Inconel-600 specimen as the main materials of internal system components of the plant. The effects of type of neutral salt as an electrolyte, current density, and concentration of electrolyte on the dissolution of the materials were evaluated. On the basis of the results obtained through the basic inactive experiments, electrochemical decontamination tests using the specimens contaminated with uranium compounds such as $UO_2$, AUC (ammonium uranyl carbonate) and ADU (ammonium diuranate) taken from an uranium conversion plant were peformed in $Na_2SO_4$ and $NaNO_3$ solution. It was verified that the electrochemical decontamination of the dismantled metallic wastes was quite successful in $Na_2SO_4$ and $NaNO_3$ neutral salt electrolyte by reducing $\beta$ radioactivities below the level of self disposal with authorization within 10 minutes regardless of the type of contaminants and the degree of contamination.

  • PDF

DESIGN AND DEVELOPMENT OF MULTI-PURPOSE CCD CAMERA SYSTEM WITH THERMOELECTRIC COOLING I. HARDWARE (열전냉각방식의 범용 CCD 카메라 시스템 개발 I. 하드웨어)

  • Kang, Y.W.;Byun, Y.I.;Rhee, J.H.;Oh, S.H.;Kim, D.K.
    • Journal of Astronomy and Space Sciences
    • /
    • v.24 no.4
    • /
    • pp.349-366
    • /
    • 2007
  • We designed and developed a multi-purpose CCD camera system for three kinds of CCDs; KAF-0401E($768{\times}512$), KAF-1602E($1536{\times}1024$), KAF-3200E($2184{\times}1472$) made by KODAK Co.. The system supports fast USB port as well as parallel port for data I/O and control signal. The packing is based on two stage circuit boards for size reduction and contains built-in filter wheel. Basic hardware components include clock pattern circuit, A/D conversion circuit, CCD data flow control circuit, and CCD temperature control unit. The CCD temperature can be controlled with accuracy of approximately $0.4^{\circ}C$ in the max. range of temperature, ${\Delta}33^{\circ}C$. This CCD camera system has with readout noise $6\;e^-$, and system gain $5\;e^-/ADU$. A total of 10 CCD camera systems were produced and our tests show that all of them show passable performance.

DEVELOPMENT OF CCD IMAGING SYSTEM USING THERMOELECTRIC COOLING METHOD (열전 냉각방식을 이용한 극미광 영상장비 개발)

  • Park, Young-Sik;Lee, Chung-Woo;Jin, Ho;Han, Won-Yong;Nam, Uk-Won;Lee, Yong-Sam
    • Journal of Astronomy and Space Sciences
    • /
    • v.17 no.1
    • /
    • pp.53-66
    • /
    • 2000
  • We developed low light CCD imaging system using thermoelectric cooling method collaboration with a company to design a commercial model. It consists of Kodak KAF-0401E(768$\times$512 pixels) CCD chip, thermoelectric module manufactured by Thermotek. This TEC system can reach an operative temperature of $-25^{\circ}C$. We employed an Uniblitz VS25s shutter and it has capability a minimum exposure time 80ms. The system components are an interface card using a Korea Astronomy Observatory (hereafter KAO) ISA bus controller, image acquisition with AD9816 chip, that is 12bit video processor. The performance test with this imaging system showed good operation within the initial specification of our design. It shows a dark current less than 0.4e-/pixel/sec at a temperature of $-10^{\circ}C$, a linearity 99.9$\pm$0.1%, gain 4.24e-/adu, and system noise is 25.3e-(rms). For low temperature CCD operation, we designed a TEC, which uses a one-stage peltier module and forced air heat exchanger. This TEC imaging system enables accurate photometry($\pm$0.01mag) even though the CCD is not at 'conventional' cryogenic temperatures(140k). The system can be a useful instrument for any other imaging applications. Finally, with this system, we obtained several images of astronomical objects for system performance tests.

  • PDF

Development of Land Management Information System(LMIS) (토지관리정보체계 시스템구축방안 -시스템개발을 중심으로-)

  • 서창완;문은호;최병남;김대종
    • Spatial Information Research
    • /
    • v.9 no.1
    • /
    • pp.73-89
    • /
    • 2001
  • In the recent rapidly changing technology environment the computerization of administration business using GIS is driven or will be driven to give improved information services for the people by local government or central government with huge budget. Development of GIS for local governments is investigated with huge budge. Development of GIS for local governments is investigated to prevent local government from investing redundant money and to reuse the existing investment at this time. The purpose of this study is finding the development method of Land Management Information System (LMIS) to give service and share data in various computing environment of local governments. To do this, we have to develop LMIS as open system with interoperability and we explain it with a focus to framework of Open LMIS. According to recent trend of technology we developed Open LMIS for convenient maintenance with nationwide LMIS expansion at hand. This system was developed at the $\ulcorner$Land Management Information System Development$\lrcorner$project which was managed by Ministry of Construction and Transportation (MOCT). GIS application was based on OpenGIS CORBA specification for development of standard interface and RUP(Rational Unified Process) for development method and LML(Unified Modeling Language) for system design. Developed systems were land administration system for local government, spatial planning support system for regional government, and land policy support system for MOCT.

  • PDF

Implementation and Evaluation of Optimal Dose Control for Portable Detectors with SiPM (SiPM을 통한 휴대용 검출기의 최적 선량 제어에 대한 구현 및 평가)

  • Byung-Wuk Kang;Sun-Kook Yoo
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.7
    • /
    • pp.1139-1147
    • /
    • 2023
  • The purpose of this paper is to present and evaluate the performance of a method for controlling the dose for optimal image acquisition while minimizing patient exposure by applying a small-sized Photomultiplier(SiPM) sensor inside a portable detector. Portable detectors have the advantage of being able to quickly access the patient's location for rapid diagnosis, but this mobility comes with the challenge of dose control. This paper presents a method to identify the dose that can have the DQE and optimal image quality of the detector through image evaluation based on IEC62220-1-1, an international standard for X-ray imaging devices, and to identify the optimal dose by matching the ADU of the image and the output of the SiPM Sensor. The Skull AP image was acquired by implementing the detector manufacturer's reference dose. The optimal dose was 342.8 µGy, and the optimal controlled dose was 148.3 µGy, which is 57 % of the manufacturer's reference dose. The Chest AP image was 81.9 µGy and the optimal controlled dose was 27.9 µGy, which is a high dose reduction effect of 66 %. In addition, the two images were analyzed by five radiologists and found to have no clinically significant difference in anatomical delineation.

Work Pressure and Safety Behaviors among Health Workers in Ghana: The Moderating Role of Management Commitment to Safety

  • Amponsah-Tawaih, Kwesi;Adu, Michael Appiah
    • Safety and Health at Work
    • /
    • v.7 no.4
    • /
    • pp.340-346
    • /
    • 2016
  • Background: safety and healthy working environment has received numerous research attention over the years. Majority of these researches seem to have been conducted in the construction industry, with little attention in the health sector. Nonetheless, there are couple of studies conducted in Africa that suggest pressure in hospitals. Therefore the aim of the study was to examine how pressure influence safety behavior in the hospitals. With reference to the relevance of safety behavior in primary health care delivery, there was the need for the study. Method: Data was obtained from 422 public hospital employees. Respondents were assured that all information would be kept confidential to increase the response rate and acquire more accurate information. Collection of questionnaires from participants took four weeks (20 working days), after which the data was analyzed. Results: The result of the study showed that work pressure correlated negatively with safety behavior. General safety climate significantly correlated positively with safety behavior and negatively with work pressure, although the effect size for the latter was smaller. Hierarchical regression analysis showed management commitment to safety to moderate the relationship between work pressure and safety behavior. Conclusion: When employees perceive safety communication, safety systems and training to be positive, they seem to comply with safety rules and procedures than voluntarily participate in safety activities.