• Title/Summary/Keyword: ADPI

Search Result 14, Processing Time 0.027 seconds

ADPI Characteristics of a Line-Diffuser (라인-디퓨저의 ADPI특성에 관한 연구)

  • Lee, Jae-Heon;Cho, Young-Jin;Kang, Seok-Youn;Oh, Myung-Do
    • Proceedings of the KSME Conference
    • /
    • 2001.11b
    • /
    • pp.958-964
    • /
    • 2001
  • It is difficult to apply a conventional selection guide for diffusers when the diffuser is installed in a perimeter zone, because the ADPI(Air Diffusion Performance Index) vs. T/L(Throw/Length) curve listed in conventional guide does not consider the perimetric heating load. The objective of this study is to evaluate the effect of the perimetric heating load on the ADPI and to propose a selection guide for proper diffuser when perimetric heating load exists. The velocity and temperature distributions and the ADPI value are obtained numerically with various heat load ratios and air flow rates. The ADPI values by numerical result were compared with existing experimental data to verify the method for evaluation of ADPI proposed in present study. In case of a high side wall diffuser, the ADPI decreased with increases of the flow rate on every heat load ratio of present study except 0.75. Also, the ADPI vs. T/L curves have been proposed for the heat load ratios of 0.25, 0.5, 0.75 to guarantee comport thermal environment when diffusers are installed in perimeter zone.

  • PDF

ADPI Characteristics of Line Diffuser in a Room with Perimetric Heating Load (측벽 부하가 존재하는 공간에 설치된 라인 디퓨져의 ADPI 특성에 관한 연구)

  • Cho Young-Jin;Kang Seok-Youn;Moon Jong -Sun;Lee Jae-Heon
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.16 no.12
    • /
    • pp.1204-1211
    • /
    • 2004
  • It is difficult to apply a conventional selection guide for diffusers when the diffuser is installed in a perimeter zone, because the air diffusion performance index (ADPI) vs. throw/length (T/L) ratio curve listed in conventional guide does not consider the perimetric heating load through the walls. The objective of this study is to evaluate the effect of the perimetric heating load on the ADPI and propose a selection guide for a proper line diffuser when perimetric heating load exists. The velocity and temperature distributions and the ADPI values are obtained numerically with various heat load ratios and air flow rates. The velocity and temperature distributions and the ADPI values are analyzed by CFD in case of various heat load ratios and air flow rates. Also, ADPI was calculated by those results. The ADPI values by numerical results are compared with an existing experimental data to verify the method for the evaluation of ADPI proposed in a present study. In case of a line diffuser installed at the high side wall, the ADPI decreases according to the increases of the flow rate on every heat load ratio of the present study except 0.75. The ADPI vs. T/L ratio curves have been proposed for the heat load ratios of 0.25, 0.5, 0.75 to guarantee the comport thermal environment when diffusers are installed in perimeter zone.

Computer Simulation on the Thermal Environment by the Diffusion temperature and Diffusion Angle of Ceiling Type Air Conditioner in Classroom (교실에서의 천장형 냉난방기의 취출온도 및 취출각도에 따른 열환경 시뮬레이션)

  • Park, Hyo-Soon;Park, Seung-Ik;Lee, Sang-Hyeok;Lee, Kam-Gyu
    • The Journal of Sustainable Design and Educational Environment Research
    • /
    • v.4 no.4
    • /
    • pp.1-18
    • /
    • 2004
  • Research has been carried out to study thermal environment in a classroom under three kinds of air diffusion temperature and six kinds of air diffusion direction for ceiling type air conditioner. The velocity and temperature distributions of air in the room calculated by 3-dimensional numerical method(PHOENICS), This present study was also conducted to calculate the Air Diffusion Performance Index(ADPI) for cooling conditions and Predicted Percentage of Dissatisfied(PPD) for heating conditions. This analysis shows that the optimum angle of ceiling type air conditioner's diffusion is $15{\sim}30^{\circ}$ for cooling mode and about $15{\sim}45^{\circ}$ for heating mode in these calculating conditions. And also analysis has been carried out to evaluate thermal comfort of vertical and horizontal cross section of classroom.

  • PDF

Comparison of the PMV and ADPI according to Adapted Height of Ceiling-type System Air-conditioner in Large space (천정형 정풍량 시스템에어컨의 적용높이에 따른 실내온열환경 특성)

  • Sung, Sang-Chul;Kim, Hyouk-Soon;Chin, Sim-Won;Oh, Myung-Do
    • Proceedings of the SAREK Conference
    • /
    • 2009.06a
    • /
    • pp.590-595
    • /
    • 2009
  • PMV and ADPI were numerically investigated in a large space of various ceiling height with air-conditioning systems of two type. The numerical results showed that it is small that the growth of cooling load according to ceiling height rise in a large space without windows. In case of system air-conditioner of duct type embedded in the ceiling, the air mixing effect in indoor is superior to a case installed 4way cassette type in it. For controling thermal comfort at indoor, a system air-conditioner of duct type embedded in the ceiling is little influenced according to ceiling height rise in a large space considered.

  • PDF

A Study on The Performance of Ventilation and Thermal Environment for a Combined Type Diffuser in a Residential Space (거주공간에 대한 급·배기 일체형 디퓨저의 환기 및 온열환경 유지성능에 대한 연구)

  • Lim, Seok-Young;Chang, Hyun-Jae
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.29 no.2
    • /
    • pp.74-81
    • /
    • 2017
  • In this study, the combined-type diffuser developed by the Authors, in a previous study, was applied to a residential space. The performance of a ventilation and thermal environment, created by the use of a combined-type diffuser was compared to the pan-type diffuser widely used in apartment houses. In cooling conditions, because of the relatively high air flow rate of ceiling cassette-type air conditioners, the characteristics of airflow distribution in a room were governed by the air conditioner's airflow. In heating conditions, because of the low air flow rate of the diffuser, the characteristics of airflow distribution were governed by the buoyancy effect created by cold external walls and a hot floor. In terms of the Air Diffusion Performance Index (ADPI), which is a thermal environmental index, the result of a combined-type diffuser was greater than a pan-type diffuser in both of cooling and heating conditions. Consequently, the combined-type diffuser showed equal or superior ventilation and thermal environment performance compared to a pan-type diffuser.

Comparison of the Heat Treatment Intensity in Infant Formulae (조제분유의 열처리 정도 비교)

  • Park, Young-Hee;Hong, Youn-Ho
    • Korean Journal of Food Science and Technology
    • /
    • v.23 no.5
    • /
    • pp.627-632
    • /
    • 1991
  • The heat treatment indicators such as HMF contents, lactulose contents and whey protein denaturation rates were measured to refer to the heat treatment intensity of domestic market infant formulae. The HMF contents showed $21.0{\sim}43.9{\mu}mol/l:$ in the case of powder types, the HMF contents in enriched nutrient products(ii) were higher whereas in the case of liquid types they were packed in cans(i). The lactulose contents showed $2.5{\sim}11.4mg/100ml$ in the powder type and $27.0{\sim}164.8mg/100ml$ in the liquid type. There was much difference in the lactulose contents according to the product types. Compared with the ADPI standards, most of infant formulae were considered to be medium-heat class. The whey protein denaturation rates were $1.1{\sim}69.4%$ in the powder type and $37.4{\sim}71.3%$ in the liquid type.

  • PDF

A NUMERICAL INVESTIGATION OF INDOOR AIR QUALITY WITH CFD

  • Sin Vai Kuong;Sun Ho I
    • Journal of computational fluids engineering
    • /
    • v.10 no.1
    • /
    • pp.87-93
    • /
    • 2005
  • Macao, a city with three sides bounded by water, is hot and humid in weather in more than six months of a year. This uncomfortable weather induces the frequency of operating air-conditioners. Choice of location for installation of air-conditioner in a building will affect the performance of cooling effect and thermal comfort on the occupants, which in turn will affect the indoor air quality (IAQ) of the building. In the paper, investigation of distribution on carbon dioxide, room air temperature and velocity, as well as air diffusion performance index (ADPI) of a single bedroom in Macao is studied by using the computational fluid dynamics (CFD) software FLOVENT 3.2. Simulations of locating the air-conditioner at 4 different walls will be done and comparisons and analyses of the results will be performed to decide a proper location for the air-conditioner for obtaining good thermal comfort.

Air Distribution Performance According to the Gap Opening of a Temperature Controlled Diffuser (냉난방 온도감지 디퓨져의 간극변화에 따른 기류분포 특성)

  • Han Hwataik;Shin Min-Woo;Yom Chol-Min;Choi Sun-Ho
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.18 no.2
    • /
    • pp.180-185
    • /
    • 2006
  • This study has been conducted in order to develop a temperature-controlled round pan diffuser with variable-openings. Flow visualization was performed to investigate the airflow patterns according to gap openings. The velocity profiles were measured using an omni-directional anemometer for two cases, i.e. a horizontal and a vertical discharge conditions. Numerical simulation also confirms there is a narrow range of gap openings where a horizontal discharge shifts to a vertical discharge. The air distribution performance index increases abruptly when the air discharge shifts from vertical to horizontal direction.

Comparison of Indoor Thermal Environments in Winter depending on Supply Vent Configurations (급기구 형상에 따른 겨울철 실내 온열환경의 비교)

  • Han, Hwa-Taik;Jeong, Young-Kyun
    • Proceedings of the SAREK Conference
    • /
    • 2008.06a
    • /
    • pp.970-975
    • /
    • 2008
  • This study considers indoor thermal comfort in an ondol space by supply vent configurations to prevent cold draft in winter. A specially-designed vent cap has been investigated in comparison with a round pan-type vent and a simple opening without a cap. Numerical simulations have been conducted using CFD to analyze thermal comfort indices such as Predicted Mean Vote (PMV) and Effective Draft Temperature (EDT) as well as air distribution index i.e. Air Diffusion Performance Index (ADPI). Results show the new vent cap provides improved thermal comfort conditions especially near ondol heated floor, as the cold outdoor air spreads upwards along the vertical wall before reaching occupant region near floor. This paper includes discussions on the flow and comfort distributions created by the thermal jets from the vents.

  • PDF

Characteristic Evaluation of Line Diffusers for Air Quality Improvement of Laboratory (실험실 공기질 개선을 위한 라인디퓨져의 특성 평가)

  • Cho, Su-Hyen;Lee, Chul-Ku
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.17 no.6
    • /
    • pp.14-22
    • /
    • 2008
  • This study is aimed at suggesting a linear-type diffuser which is excellent in terms of range and elegance like existing diffusers in which amount and direction of wind can be freely controled, out of linear-type diffusers with the highest possibility to be adopted for living space of apartments whose height between floors is not so high and utilizing the linear-type diffuser in design. For the purpose, I examined necessary flow and noise properties of linear-type diffusers. Besides, I evaluated its ventilation capacity for persons in there by applying this in the actual living space. I evaluated features and air blast and found that in time of horizontal and vertical effusion, its T/L ratio is 1-1.5, similar to existing cardioid-type linear diffusers, while in time of slope effusion, it is similar to horizontal effusion in terms of range and it has medium figure in terms of pressure drop and effusion speed, indicating it can provide safe and pleasant indoor environment for persons in there in terms of ventilation.