• Title/Summary/Keyword: ADC map

Search Result 33, Processing Time 0.034 seconds

Evaluation of the Usefulness of PROPELLER (periodically rotated overlapping parallel lines with enhanced reconstruction) Technique to Reduce the Magnetic susceptibility artifact (Magnetic susceptibility artifact를 줄이기 위한 PROPELLER 확산강조영상기법의 유용성에 대한 평가)

  • Cho, Jae-Hwan
    • Journal of Digital Contents Society
    • /
    • v.11 no.1
    • /
    • pp.73-78
    • /
    • 2010
  • This study attempted to examine whether the propeller diffusion weighted image method may remove magnetic susceptibility artifacts caused by metallic materials. A comparison of occurrence rates of magnetic susceptibility artifacts in the four regions, both temporal lobes, pons, and orbit, between b = 0 and b = 1,000 s/mm2 images was made after obtaining echo-planar diffusion weighted image, propeller diffusion weighted image, and ADC map images, respectively, from a total of 20 patients who had MRI shots taken of their brain and were found to be with retained metallic foreign bodies within their teeth using a 3.0T MR scanner. In the case of echo-planar diffusion weighted image technique, the presence of metallic materials may bring in some limits on accurate diagnosis due to magnetic susceptibility artifacts, while the propeller diffusion weighted image technique where magnetic susceptibility artifacts decrease is expected to be more useful in ensuring accurate diagnosis in the clinical context.

Transient Splenial Lesions in the Splenium of Corpus Callosum in Seven Patients: MR Findings and Clinical Correlations (뇌량 팽대의 일과성 병변: 7명의 환자에서의 자기공명 영상소견과 임상 양상의 연관성)

  • Park, Ju Young;Lee, In Ho;Song, Chang June;Hwang, Hee Youn
    • Investigative Magnetic Resonance Imaging
    • /
    • v.17 no.1
    • /
    • pp.1-7
    • /
    • 2013
  • Purpose : The purpose of this study is to correlate the imaging findings and the clinical findings in patients with transient splenial lesions (TSL). Materials and Methods: Total of 7 patients (M: F = 4: 3; age range 11 - 38 years, mean age 25.5 years) were studied between November 2006 and April 2011. The MRI findings and clinical findings in all patients were retrospectively reviewed. The location, MR signal intensity, restricted diffusion, enhancement pattern and reversibility from the follow up images were reviewed. Clinical features were reviewed with respect to the presented symptoms, signs, treatment and outcome. Results: The lesions were located in the splenium of corpus callosum in all patients. All lesions showed high signal intensity on diffusion weighted imaging (DWI), and six patients showed restricted diffusion on the apparent diffusion coefficient (ADC) map. ADC map was not available in one patient. All lesions (n = 7) showed high signal intensity on the T2 weighted image (T2WI). Five of the patients (71.4%) with follow up images (range 7 - 34 days) showed complete resolution of focal high signal intensity on DWI, with recovery of ADC values as well as T2WI. After contrast media administration, none of the lesions showed any enhancements. All lesions with various etiologies including TB medication were developed in younger age patients and showed reversibility after the acceptable period of minimum 7 days with conservative treatment. Conclusion: All TSL showed nonspecific imaging findings, including restricted diffusion on DWI and ADC map on the initial images. However, reversibility of the lesions and the young age preference can be a characteristic finding of TSL with acceptable period of minimum 7 days. In addition, to keep it in mind that various etiologies including TB medication may cause TSL, is important for radiologists as well as clinicians.

The Principles of Diffusion MR

  • 장용민
    • Proceedings of the KSMRM Conference
    • /
    • 2003.10a
    • /
    • pp.49-53
    • /
    • 2003
  • 확산텐서영상(Diffusion Tensor Imaging)의 개념은 1980년대 중반 확산강조영상(Diffusion Weighted Imaging)의 개념이 도입되면서 거의 동시에 도입되었지만 MR 장비의 기계적 한계등으로 인해 최근에야 임상적으로 사용되기 시작했다. 확산텐서영상(DTI)과 확산강조영상(DWI)의 방법론적인 차이점은 단순히 확산강조영상의 경우 세 개의 다른방향 (X-, Y-, Z-축)으로 확산측정용 경사자장을 가하는 반면 확산텐서영상의 경우 이보다 많은 방향 (최소한 6 방향)으로 확산측정용 경사자장을 가한다는 점이다. 이러한 차이로부터 금방 알 수 있는 점은 확산강조영상은 확산텐서영상의 일부라는 점이다. 즉, 확산텐서영상의 경우 더 많은 방향으로 확산측정용 경사자장을 가했으므로 더 많은 정보를 획득할 수 있고 이중 세 개의 방향 (주로 X,Y,Z)에 대한 정보만을 이용하게 되면 확산강조영상이다. 이러한 이유로 확산텐서영상을 획득하면 확산강조영상에서 얻게 되는 방향별 확산강조영상, 등방성(isotropic) 확산강조영상, ADC (Apparent Diffusion Coefficient) map등도 기본적으로 얻게 되므로 추가로 확산강조영상을 획득할 필요가 없다. 본 강의에서는 이러한 확산(텐서)영상의 물리적 원리를 복잡한 수학적 설명보다는 개념 위주로 설명해 보고자 한다.

  • PDF

An Unusual Case of Japanese Encephalitis Involving Unilateral Deep Gray Matter and Temporal Lobe on Diffusion-Weighted MRI

  • Seok, Hee Young;Lee, Dong Hoon
    • Investigative Magnetic Resonance Imaging
    • /
    • v.20 no.4
    • /
    • pp.250-253
    • /
    • 2016
  • Acute Japanese encephalitis (JE) is an endemic viral infectious disease in various parts of Far East and Southeast Asian countries including Korea. Bilateral thalami are the most common involving sites in JE. Other areas including the basal ganglia, substantia nigra, red nucleus, pons, cerebral cortex and cerebellum may be also involved. We report an extremely unusual brain diffusion-weighted MR imaging (DWI) findings in a 53-year-old man with serologically proven JE involving unilateral deep gray matter and temporal lobe, which shows multifocal high signal intensities in left thalamus, left substantia nigra, left caudate nucleus and left medial temporal cortex on T2-weighted image and DWI with iso-intensity on apparent diffusion coefficient (ADC) map.

Quantitative Evaluation of the Corticospinal Tract Segmented by Using Co-registered Functional MRI and Diffusion Tensor Tractography (정상인에서 기능적 뇌 자기공명영상과 확산텐서영상 합성기법을 이용한 피질척수로의 위치에 따른 정량적 분석)

  • Jang, Sung-Ho;Hong, Ji-Heon;Byun, Woo-Mok;Hwang, Chang-Ho;Yang, Dong-Seok
    • Investigative Magnetic Resonance Imaging
    • /
    • v.13 no.1
    • /
    • pp.40-46
    • /
    • 2009
  • Purpose : The purpose of this study was to investigate the quantitative evaluation of the corticospinal tract (CST) at the multiple levels by using functional MRI (fMRI) co-registered to diffusion tensor tractography (DTT). Materials and Methods : Ten normal subjects without any history of neurological disorder participated in this study. fMRI was performed at 1.5 T MR scanner using hand grasp-release movement paradigm. DTT was performed by using DtiStudio on the basis of fiber assignment continuous tracking algorithm (FACT). The seed region of interest (ROI) was drawn in the area of maximum fMRI activation during the motor task of hand grasp-release movement on a 2-D fractional anisotropy (FA) color map, and the target ROI was drawn in the cortiocospinal portion of anterior lower pons. We have drawn five ROIs for the measurement of FA and apparent diffusion coefficient (ADC) along the corona radiata (CR) down to the medulla. Results : The contralateral primary sensorimotor cortex (SM1) was mainly found to be activated in all subjects. DTT showed that tracts originated from SM1 and ran to the medulla along the known pathway of the CST. In all subjects, FA values of the CST were higher at the level of the midbrain and posterior limb of internal capsule (PLIC) than the level of others. Conclusion : Our study showed that co-registered fMRI and DTT has elucidated the state of CST on 3-D and analyzed the quantitative values of FA and ADC at the multiple levels. We conclude that co-registered fMRI and DTT may be applied as a useful tool for clarifying and investigating the state of CST in the patients with brain injury.

  • PDF

Ex Vivo MR Diffusion Coefficient Measurement of Human Gastric Tissue (인체의 위 조직 시료에서 자기공명영상장치를 이용한 확산계수 측정에 대한 기초 연구)

  • Mun Chi-Woong;Choi, Ki-Sueng;Nana Roger;Hu, Xiaoping P.;Yang, Young-Il;Chang Hee-Kyung;Eun, Choong-Ki
    • Journal of Biomedical Engineering Research
    • /
    • v.27 no.5
    • /
    • pp.203-209
    • /
    • 2006
  • The aim of this study is to investigate the feasibility of ex vivo MR diffusion tensor imaging technique in order to observe the diffusion-contrast characteristics of human gastric tissues. On normal and pathologic gastric tissues, which have been fixed in a polycarbonate plastic tube filled with 10% formalin solution, laboratory made 3D diffusion tensor Turbo FLASH pulse sequence was used to obtain high resolution MR images with voxel size of $0.5{\times}0.5{\times}0.5mm^3\;using\;64{\times}32{\times}32mm^3$ field of view in conjunction with an acquisition matrix of $128{\times}64{\times}64$. Diffusion weighted- gradient pulses were employed with b values of 0 and $600s/mm^2$ in 6 orientations. The sequence was implemented on a clinical 3.0-T MRI scanner(Siemens, Erlangen, Germany) with a home-made quadrature-typed birdcage Tx/Rx rf coil for small specimen. Diffusion tensor values in each pixel were calculated using linear algebra and singular value decomposition(SVD) algorithm. Apparent diffusion coefficient(ADC) and fractional anisotropy(FA) map were also obtained from diffusion tensor data to compare pixel intensities between normal and abnormal gastric tissues. The processing software was developed by authors using Visual C++(Microsoft, WA, U.S.A.) and mathematical/statistical library of GNUwin32(Free Software Foundation). This study shows that 3D diffusion tensor Turbo FLASH sequence is useful to resolve fine micro-structures of gastric tissue and both ADC and FA values in normal gastric tissue are higher than those in abnormal tissue. Authors expect that this study also represents another possibility of gastric carcinoma detection by visualizing diffusion characteristics of proton spins in the gastric tissues.

Multi-slice Multi-echo Pulsed-gradient Spin-echo (MePGSE) Sequence for Diffusion Tensor Imaging MRI: A Preliminary Result (일회 영상으로 확산텐서 자기공명영상을 얻을 수 있는 다편-다에코 펄스 경사자장 스핀에코(MePGSE) 시퀀스의 초기 결과)

  • Jahng, Geon-Ho;Pickup, Stephen
    • Progress in Medical Physics
    • /
    • v.18 no.2
    • /
    • pp.65-72
    • /
    • 2007
  • An echo planar imaging (EPI)-based spin-echo sequence Is often used to obtain diffusion tensor imaging (DTI) data on most of the clinical MRI systems, However, this sequence is confounded with the susceptibility artifacts, especially on the temporal lobe in the human brain. Therefore, the objective of this study was to design a pulse sequence that relatively immunizes the susceptibility artifacts, but can map diffusion tensor components in a single-shot mode. A multi-slice multi-echo pulsed-gradient spin-echo (MePGSE) sequence with eight echoes wasdeveloped with selective refocusing pulses for all slices to map the full tensor. The first seven echoes in the train were diffusion-weighted allowing for the observation of diffusion in several different directions in a single experiment and the last echo was for crusher of the residual magnetization. All components of diffusion tensor were measured by a single shot experiment. The sequence was applied in diffusive phantoms. The preliminary experimental verification of the sequence was illustrated by measuring the apparent diffusion coefficient (ADC) for tap water and by measuring diffusion tensor components for watermelon. The ADC values in the series of the water phantom were reliable. The MePGSE sequence, therefore, may be useful in human brain studies.

  • PDF

Magnetic Resonance Imaging Features of Suspected Acute Spinal Cord Infarction in Two Cats (두 마리 고양이에서 발생한 급성 척수 경색의 자기 공명 영상학적 진단 증례)

  • Jung, Sun-Young;Kim, Bo-Eun;Ji, Seo-Yeoun;Yoon, Jung-Hee;Choi, Min-Cheol
    • Journal of Veterinary Clinics
    • /
    • v.30 no.4
    • /
    • pp.320-323
    • /
    • 2013
  • Spinal cord infarction is becoming recognized as an important cause of acute myelopathy in cats. Although the definitive diagnosis is confirmed through postmortem histopathologic examination, MR imaging features provide valuable informations for the diagnosis of spinal cord infarction. The aim of this report is to describe MR findings of acute spinal cord infarction in two cats and to evaluate usefulness of low field MRI (0.3Tesla) as a potential diagnostic tool of acute spinal cord infarction. A cat (unknown age, neutered male mixed breed cat) was referred one day after the acute onset of non-ambulatory spastic tetraparesis and the other cat (a 9-year-old, neutered female domestic short hair cat) was presented due to the acute onset of non-ambulatory paraparesis and one day later paraplegia. The lesions of the MR images were shown on the spinal cord parenchyma over C2 to C6 in case 1 and L2 to L5 in case 2. The MR images in these two cases were characterized by focal intramedullary lesions, mainly involving grey matter which were hyperintense T2 weighted and FLAIR images and hyperintense on DWI and hypointense on ADC map. The MR findings in both cases were highly suggestive of acute spinal cord infarctions, based upon previous reported small animal cases and human cases. In conclusion, based on MR features, together with the history and clinical examination findings, MRI modality can be used as an antemortem tool for the diagnosis of acute spinal cord infarction in cats.

Efficient Signature-Driven Self-Test for Differential Mixed-Signal Circuits

  • Kim, Byoungho
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.16 no.5
    • /
    • pp.713-718
    • /
    • 2016
  • Predicting precise specifications of differential mixed-signal circuits is a difficult problem, because analytically derived correlation between process variations and conventional specifications exhibits the limited prediction accuracy due to the phase unbalance, for most self-tests. This paper proposes an efficient prediction technique to provide accurate specifications of differential mixed-signal circuits in a system-on-chip (SoC) based on a nonlinear statistical nonlinear regression technique. A spectrally pure sinusoidal signal is applied to a differential DUT, and its output is fed into another differential DUT through a weighting circuitry in the loopback configuration. The weighting circuitry, which is employed from the previous work [3], efficiently produces different weights on the harmonics of the loopback responses, i.e., the signatures. The correlation models, which map the signatures to the conventional specifications, are built based on the statistical nonlinear regression technique, in order to predict accurate nonlinearities of individual DUTs. In production testing, once the efficient signatures are measured, and plugged into the obtained correlation models, the harmonic coefficients of DUTs are readily identified. This work provides a practical test solution to overcome the serious test issue of differential mixed-signal circuits; the low accuracy of analytically derived model is much lower by the errors from the unbalance. Hardware measurement results showed less than 1.0 dB of the prediction error, validating that this approach can be used as production test.