• 제목/요약/키워드: ACL

검색결과 460건 처리시간 0.026초

ARQ를 고려한 블루투스 무선 링크의 성능 분석 (Performance Evaluation of Bluetooth Radio Link with ARQ Protocol)

  • 박홍성;정명순
    • 산업기술연구
    • /
    • 제21권A호
    • /
    • pp.59-64
    • /
    • 2001
  • This paper analyzes the performance of the several types of ACL(Asynchronous ConnectionLess) packets used in Bluetooth according to a BER(Bit Error Rate) and a packet length and proposes an optimal packet type and an optimal size of the packet being able to be used under the given BER. This paper proposes how to obtain the optimal packet type and the optimal size of the packet maximizing the performance measure under the given BER. In addition, this paper shows that the optimal type and size of the packet maximizing the throughput are different from those maximizing the mean transmission time. This occurs because the Bluetooth uses not only one type of packet but also various types of packets.

  • PDF

다양한 변형률 에너지 함수를 사용한 전방 및 후방 십자 인대의 모델링에 관한 연구 (A study on modelling for ACL and PCL using various strain energy functions)

  • 임준택;최덕기;김영은
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2008년도 추계학술대회A
    • /
    • pp.658-663
    • /
    • 2008
  • The mechanical study on the anterior and posterior cruciate ligament(ACL, PCL) is of importance because the recent increase of outdoor and indoor activities is directly related to causing sport injuries on the knee joints. Constitutive models for many biological tissues have been known as hyperelasticitic models. The elastic behavior of ACL and PCL may be described by the free energy function which accounts for the matrix and the collagen fibers. This paper addresses a comparison of different types of the free energy function to the existing results.

  • PDF

A Comparative Study of Operation Characteristics of Active Clamp Forward Converter Based on Loss analysis

  • Oh, Deog-Jin;Kim, Hee-Jun
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 1998년도 Proceedings ICPE 98 1998 International Conference on Power Electronics
    • /
    • pp.636-641
    • /
    • 1998
  • In this paper, operation characteristics of the Zero-voltage-Switching(ZVS) mode and Non-Zero-Voltage-Switching (NZVS) mode of the active clamp (ACL) forward converter are compared through the loss analysis. The losses of semiconductor devices, transformer and passive elements of the converter are analyzed and compared for each type of operation mode. In order to verify the validity of the analysis, we have built a 50W ACL forward converter and measured the losses of the converter. From the experiment it is known that the ACL forward converter shows nearly same loss distribution for both of operation modes

  • PDF

손실해석을 통한 능동 클램프 포워드 컨버터의 동작 특성비교 (A Comparative Study of Operation characteristics of Active Clamp Forward Converter Based on Loss Analysis)

  • 오덕진;김희준;김창선
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 하계학술대회 논문집 F
    • /
    • pp.2039-2041
    • /
    • 1998
  • In this paper, Operation characteristics of the active clamp(ACL) zero-voltage-switching(ZVS) forward converter(FC) and active clamp hard- switching(HS) forward converter are compared with respect to loss analysis. The losses of semiconductor (including conduction losses and switching losses), transformer(containing the core loss and copper loss) and parasitic element of passive element (capacitor, inductor) are measured and compared for each type. For an experiment we have built 50W ACL ZVS-FC and ACL HS-FC, in which the switching frequency is 200kHz, and test it. The experimental results show that both types of operation have nearly same characteristics.

  • PDF

IGBT를 이용한 전동차용 보조전원장치의 소음 저감에 관한 연구 (A Study on Noise Reduction for Auxiliary Power Supply of railway Vehicle Using IGBT)

  • 노애숙;김주범;배기훈;최종묵
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 1998년도 창립기념 춘계학술대회 논문집
    • /
    • pp.280-286
    • /
    • 1998
  • In recent years, the interest in noise increases gradually and the low noise level becomes one of the important performances in electrical equipment for railway vehicle. In the auxiliary power supply, most of the noise is made by the current ripple of alternating current reactor(ACL) which filters the output voltage. And this current ripple results from the voltage harmonics across the ACL. So the noise can be reduced by eliminating the voltage harmonics across the ACL. This paper shows harmonic eliminating technique which is making gating signals of upper and lower inverter have a phase difference in the 12-step inverter type auxiliary power supply. This technique was proved by testing on the developed 180KVA auxiliary power supply using IGBT.

  • PDF

블루투스 Synchronous Connection Oriented Link를 사용한 네트워크 제어 시스템 (Bluetooth Synchronous Connection Oriented Link Usage in Networked Control Systems)

  • ;박정일
    • 제어로봇시스템학회논문지
    • /
    • 제18권8호
    • /
    • pp.731-737
    • /
    • 2012
  • In this paper the usage of Bluetooth in networked control systems is described. ACL links and commonly used serial port profile built on top of ACL links are analyzed and their problems such as unpredictable latency are discovered. SCO link packet scheduling, latency estimation and setup procedure are examined. SCO link is suggested as proper link for NCS, due to its low latency and low variance. Smith predictor use for latency compensation is described and its impact on control performance is estimated. A number of experiments on DC motor position control are performed and control performance of system utilizing SCO link with and without Smith predictor is proved to be higher than control performance of system utilizing ACL link.

Effect of nano-composite materials on repair of ligament injury in sports detoxification

  • Lu, Chunxia;Lu, Gang;Dong, Weixin;Liu, Xia
    • Advances in nano research
    • /
    • 제13권3호
    • /
    • pp.247-257
    • /
    • 2022
  • Extraordinary properties of nanocomposites make them a primary replacement for many conventional materials. Anterior cruciate ligament (ACL) reconstruction, which is a frequent surgery in sport activities, is one of the fields in which nanocomposites could be utilized. In the present study, the mechanical properties of different porous scaffolds made from graphene nano-composites are presented ad load bearing capacity of these materials is calculated using finite element method. The numerical results are further compared with experimental published data. In addition, several geometrical and material parameters are analyzed to find the best configuration of nanocomposite scaffolds in reconstruction of ACL. Moreover, coating of detoxification chemicals are extremely easier on the nano-structured materials than conventional one. Detoxification potential of nano-composites in the injured body are also discussed in detail. The results indicated that nano-composite could be successfully used in place of auto- and allografts and also instead of conventional metallic screws in reconstruction of ACL.

전방 십자 인대 재 재건술 단기 추시 결과 (Revision of Failed ACL Reconstruction - Early Result -)

  • 안진환;조용진;이용석;신성기
    • 대한관절경학회지
    • /
    • 제7권2호
    • /
    • pp.169-175
    • /
    • 2003
  • 목적 : 실패한 전방십자인대 재건술후 시행한 전방십자인대 재 재건술의 단기추시 결과를 평가하고자 하였다. 대상 및 방법 : 1997년 8월부터 2002년 2월까지 실패한 전방십자인대 재건술에 대하여 재 재건술을 시술 받았던 18예를 대상으로 하였으며, 재건술후 재 재건술까지의 평균기간은 39$(7\~120)$개월 이었으며, 동종이식건 14예$(78\%)$, 자가이식건 4예$(22\%)$를 관절경을 이용하여 전방십자인대 재 재건술을 시술하였다. 주 증상으로는 불안정성이 16예$(89\%)$로 가장 많았고, 전방십자인대 재건술을 한번 시행받았던 경우가 16예$(89\%)$, 두번 시행받았던 경우가 2예$(11\%)$였다. 술전, 술후 및 추시관찰시 Lachman test, pivot shift test, KT 2000 및 방사선학적으로 전방십자인대의 안정성을 평가하였으며, Lysholm score 및 HSS score를 비교 분석하였고 환자의 주관적 만족도를 조사하였다. 결과 : 평균 추시관찰 기간은 27$(12\~60)$개월이었으며, 술전 Lachman test 및 pivot shift test는 전예에서 양성의 소견을 보였으나 술후 대부분의 예에서 음성으로 나타났으며, KT 2000은 술전 7.75$(3.5\~12.5)$mm에서 술후 최종추시시 2.36$(1.0\~6.0)$mm로 안정되었다. Lysholm score 및 HSS score는 각각 술전 72.6$(66\~77)$점, 72.5$(68\~78)$점에서 술후 최종추시 시 89.2$(80\~92)$점, 88.2$(81\~92)$점으로 향상되었다. 환자의 대부분은 수술결과에 만족$(89\%)$하고 있었다. 전방십자인대 재건술의 실패원인으로는 대퇴터널의 부정위치가 11예$(61\%)$로 가장 많았다. 결론 : 실패한 전방십자인대 재건술의 치료로 적절한 이식건을 이용하여 관절경적 전방십자인대 재 재건술을 시술함으로서 주관적 및 객관적으로 비교적 안정적인 슬관절을 얻을 수 있었으나, 일차 전방십자인대 재건술의 가장 많은 실패의 원인이 수술 수기의 오류임을 감안한다면 정확한 수술 수기로 전방십자인대 재건술을 시술하는 것이 중요할것으로 사료된다.

  • PDF

전방 십자 인대 파열후 자가 슬개건을 이용한 재건술군과 부분 손상후 보존적 치료군의 비교 (Comparison between Conservative Treatment of partial ACL Rupture and Reconstructive Surgery with BPTB Autograft in ACL Rupture)

  • 이동철;이수호;김동한
    • 대한정형외과스포츠의학회지
    • /
    • 제1권2호
    • /
    • pp.131-137
    • /
    • 2002
  • 목적: 전방십자인대부분파열후보존적치료군과완전파열후자가슬개건을이용한재건술군간의기능적평가, 활동도및전방안정성을비교평가하고자하였다.대상및방법: 전방십자인대손상으로진단되고관절경으로진단치료한38명의환자를대상으로2년이상추시하였으며전방십자인대50$\%$이하파열된부분손상군1 2명(평균연령: 38.3세), 완전파열후자가슬개건을이용한재건술군26명(평균연령: 25.3세)을대상으로하였다. 객관적인안정성은KT-2000 Arthrometer를이용하여15lb와20lb전방전위부하로측정하였으며,기능평가는Lysholm score, 활동도는Tegner activity score를이용하여분석하였다.결과: Lysholm의기능평가는부분손상군은88.5, 재건술군은89.3이었고, Tegner의활동도는부분손상군5.3, 재건술군5.1이었다( P<0.05 ) .전방안정성에서평균전방전위는20lb 부하하에부분손상군에서건측에비해1.7$\pm$1.4 mm, 재건술군에서는건측에비해2.3$\pm$1.9 mm였으며(P<0.05), 15lb 부하하에서는부분손상군은건측에비해1.2$\pm$1.0 mm, 재건술군에서는건측에비해1.4$\pm$1.5 mm였다(P<0.05). 합병증으로관절부종, 불안정성, 전방슬관절동통이었다. 불안정성은부분손상군에서흔한합병증이었다.결론: 양군에서임상결과들은비슷하였으며, Lysholm의기능평가는양호하였고, Tegner 활동도상태는양군에서평균적으로신체적인적당한활동(조깅, 규칙적인자전거타기)은유지되어50$\%$이하의부분손상군에대한보존적치료는양호한결과가나타난것으로사료되었다.

  • PDF

이중 다발 전방십자인대 재건술의 임상적 결과 및 이차적 관절경 소견 (Clinical Outcome and Arthroscopic Evaluation of Double-Bundle Anterior Cruciate Ligament Reconstruction)

  • 송은규;선종근;이경재;김형순
    • 대한정형외과스포츠의학회지
    • /
    • 제9권1호
    • /
    • pp.28-34
    • /
    • 2010
  • 목적: 본 연구는 이중 다발 전방십자인대 재건술 후의 단기 임상결과와 이차적 관절경 소견을 알아보았다. 대상 및 방법: 이중 다발 전방십자인대 재건술 후에 최소 24개월 이상 추시가 가능하였던 49 예(환자)를 대상으로 하였다. 임상적 결과로 Lysholm 슬관절 점수, Tegner 활동 점수, 도수 및 기계적 전방 안정성 검사를 시행하였다. 15 예에서 스테플 제거와 함께 이차적 관절경 수술을 시행하여, 재건된 전방십자인대의 파열 유무와 이식건의 주관적인 긴장 정도 및 활액막 형성 정도를 검사하였다. 결과: Lysholm 슬관절 및 Tegner 활동 점수는 각각 술전 67.4, 2.0에서 최종 추시에 96.1, 6.1로 호전되었다 (p<0.01). Lachman 및 pivot-shift 검사에서 39예, 36예가 정상범위로 호전되었다. 스트레스 방사선 검사의 양측 차이 정도는 10.8 mm 에서 3.3 mm로 의미있게 호전되었다 (p<0.01). 이차적 관절경 소견상 모든 환자에서 전내측 다발이 정상 및 정상에 가까운 소견이 관찰되었으나, 8예 (53.3%) 에서 후외측 다발의 부분 및 완전 파열이 관찰되었다. 결론: 이중 다발 전방십자인대 재건술이 임상적으로 슬관절의 회전 및 전, 후방 안정성을 복원하는 효과적인 수술법이라도, 이차적 관절경 수술을 시행한 증례의 몇 예에서 후 외측 다발의 파열이 관찰되었다.

  • PDF