• Title/Summary/Keyword: ACFs

Search Result 749, Processing Time 0.02 seconds

The new frontier: utilizing ChatGPT to expand craniofacial research

  • Andi Zhang;Ethan Dimock;Rohun Gupta;Kevin Chen
    • Archives of Craniofacial Surgery
    • /
    • v.25 no.3
    • /
    • pp.116-122
    • /
    • 2024
  • Background: Due to the importance of evidence-based research in plastic surgery, the authors of this study aimed to assess the accuracy of ChatGPT in generating novel systematic review ideas within the field of craniofacial surgery. Methods: ChatGPT was prompted to generate 20 novel systematic review ideas for 10 different subcategories within the field of craniofacial surgery. For each topic, the chatbot was told to give 10 "general" and 10 "specific" ideas that were related to the concept. In order to determine the accuracy of ChatGPT, a literature review was conducted using PubMed, CINAHL, Embase, and Cochrane. Results: In total, 200 total systematic review research ideas were generated by ChatGPT. We found that the algorithm had an overall 57.5% accuracy at identifying novel systematic review ideas. ChatGPT was found to be 39% accurate for general topics and 76% accurate for specific topics. Conclusion: Craniofacial surgeons should use ChatGPT as a tool. We found that ChatGPT provided more precise answers with specific research questions than with general questions and helped narrow down the search scope, leading to a more relevant and accurate response. Beyond research purposes, ChatGPT can augment patient consultations, improve healthcare equity, and assist in clinical decision-making. With rapid advancements in artificial intelligence (AI), it is important for plastic surgeons to consider using AI in their clinical practice to improve patient-centered outcomes.

Comparison of local flaps versus skin grafts as reconstruction methods for defects in the medial canthal region

  • Min Hak Lee;Hoon Soo Kim;Yong Chan Bae
    • Archives of Craniofacial Surgery
    • /
    • v.25 no.3
    • /
    • pp.133-140
    • /
    • 2024
  • Background: The medial canthal region features a complex three-dimensional and internal anatomical structure. When reconstructing a defect in this area, it is crucial to consider both functional and aesthetic aspects, which presents significant challenges. Generally, local flaps are preferred for reconstruction; however, skin grafts can be used when local flaps are not feasible. Therefore, we conducted a comparative analysis of surgical outcomes skin grafts when local flaps were not feasible, to determine which surgical method is more effective for medial canthal region reconstruction. Methods: Twenty-five patients who underwent medial canthal region reconstruction using skin grafts or local flaps from 2002 to 2021 were enrolled. Patient information was obtained from medical records. Five plastic surgeons evaluated the surgical outcomes based on general appearance, color, contour, and symmetry. Results: Skin grafts were used in eight patients and local flaps were used in 13. Combined reconstructions were employed in four cases. Minor complications arose in four cases but improved with conservative treatment. No major complications were reported. Recurrence of the skin cancer was noted in two cases. All categories showed higher scores for the local flap compared to both skin graft and combined reconstruction; however, the differences were not statistically significant respectively. Conclusion: The choice of appropriate surgical methods for reconstructing defects in the medial canthal region depends on various factors, including the patient's overall health, the size and depth of the defect, and the degree of involvement of surrounding structures. When a local flap is not feasible, a skin graft may provide favorable surgical outcomes. Therefore, a skin graft can serve as a viable alternative for reconstructing the medial canthal region.

The nasoalveolar molding technique versus DynaCleft nasal elevator application in infants with unilateral cleft lip and palate

  • Abdallah Bahaa;Nada El-Bagoury;Noura Khaled;Sameera Mohamed;Ahmed Bahaa;Ahmed Mohamed Ibrahim;Khaled Mohamad Taha;Mohsena Ahmad Abdarrazik
    • Archives of Craniofacial Surgery
    • /
    • v.25 no.3
    • /
    • pp.123-132
    • /
    • 2024
  • Background: The introduction of presurgical nasoalveolar molding represented a significant departure from traditional molding methods. Developed by Grayson and colleagues in 1993, this technique combines an intraoral molding device with a nasal molding stent. This study aimed to compare the Grayson nasoalveolar molding appliance versus DynaCleft appliance as two methods of presurgical nasoalveolar molding. Methods: A single-blinded, randomized, parallel-arm clinical trial was conducted. Sixteen infants with complete unilateral cleft lip and palate were enrolled and divided into two groups of eight. Group 1 was treated with a modified Grayson nasoalveolar molding appliance that included a nasal stent, while group 2 was treated with DynaCleft elastic adhesive tape and an external nasal elevator. Standardized digital photographs of each infant were taken at baseline and post-treatment using a professional camera. Nine extraoral anthropometric measurements were obtained from each image using image measurement software. Results: The modified Grayson nasoalveolar appliance demonstrated a more significant improvement compared to DynaCleft in terms of alar length projection (on both sides), columella angle, and nasal tip projection. Symmetry ratios also showed enhancement, with significant improvements observed in nasal width, nasal basal width, and alar length projection (p< 0.05). Conclusion: Both the modified Grayson nasoalveolar appliance and DynaCleft appear to be effective presurgical infant orthopedics treatment options, demonstrating improvements in nasolabial aesthetics. The modified Grayson appliance, equipped with a nasal stent, improved nasal symmetry more effectively than DynaCleft, resulting in a straighter columella and a more medially positioned nasal tip.

Comparison of pain relief in soft tissue tumor excision: anesthetic injection using an automatic digital injector versus conventional injection

  • Hye Gwang Mun;Bo Min Moon;Yu Jin Kim
    • Archives of Craniofacial Surgery
    • /
    • v.25 no.1
    • /
    • pp.17-21
    • /
    • 2024
  • Background: The pain caused by local anesthetic injection can lead to patient anxiety prior to surgery, potentially necessitating sedation or general anesthesia during the excision procedure. In this study, we aim to compare the pain relief efficacy and safety of using a digital automatic anesthetic injector for local anesthesia. Methods: Thirty-three patients undergoing excision of a benign soft tissue tumor under local anesthesia were prospectively enrolled from September 2021 to February 2022. A single-blind, randomized controlled study was conducted. Patients were divided into two groups by randomization: the experimental group with digital automatic anesthetic injector method (I-JECT group) and the control group with conventional injection method. Before surgery, the Amsterdam preoperative anxiety information scale was used to measure the patients' anxiety. After local anesthetic was administered, the Numeric Pain Rating Scale was used to measure the pain. The amount of anesthetic used was divided by the surface area of the lesion was recorded. Results: Seventeen were assigned to the conventional group and 16 to the I-JECT group. The mean Numeric Pain Rating Scale was 1.75 in the I-JECT group and 3.82 in conventional group. The injection pain was lower in the I-JECT group (p< 0.01). The mean Amsterdam preoperative anxiety information scale was 11.00 in the I-JECT group and 9.65 in conventional group. Patient's anxiety did not correlate to injection pain regardless of the method of injection (p= 0.47). The amount of local anesthetic used per 1 cm2 of tumor surface area was 0.74 mL/cm2 in the I-JECT group and 2.31 mL/cm2 in the conventional group. The normalization amount of local anesthetic was less in the I-JECT group (p< 0.01). There was no difference in the incidence of complications. Conclusion: The use of a digital automatic anesthetic injector has shown to reduce pain and the amount of local anesthetics without complication.

Orbital floor defect caused by invasive aspergillosis: a case report and literature review

  • Sang Woo Han;Min Woo Park;Sug Won Kim;Minseob Eom;Dong Hwan Kwon;Eun Jung Lee;Jiye Kim
    • Archives of Craniofacial Surgery
    • /
    • v.25 no.1
    • /
    • pp.27-30
    • /
    • 2024
  • Fungal sinusitis is relatively rare, but it has become more common in recent years. When fungal sinusitis invades the orbit, it can cause proptosis, chemosis, ophthalmoplegia, retroorbital pain, and vision impairment. We present a case of an extensive orbital floor defect due to invasive fungal sinusitis. A 62-year-old man with hypertension and a history of lung adenocarcinoma, presented with right-side facial pain and swelling. On admission, the serum glucose level was 347 mg/dL, and hemoglobin A1c was 11.4%. A computed tomography scan and a Waters' view X-ray showed right maxillary sinusitis with an orbital floor defect. On hospital day 3, functional endoscopic sinus surgery was performed by the otorhinolaryngology team, and an aspergilloma in necrotic inflammatory exudate obtained during exploration. On hospital day 7, orbital floor reconstruction with a Medpor Titan surgical implant was done. In principle, the management of invasive sino-orbital fungal infection often begins with surgical debridement and local irrigation with an antifungal agent. Exceptionally, in this case, debridement and immediate orbital floor reconstruction were performed to prevent enophthalmos caused by the extensive orbital floor defect. The patient underwent orbital floor reconstruction and received intravenous and oral voriconazole. Despite orbital invasion, there were no ophthalmic symptoms or sequelae.

Auricle reconstruction with autologous costal cartilage versus polyethylene implants in microtia patients: a meta-analysis

  • Yun Jung Kim;Kyunghyun Min;Kyunghyun Min;Tai Suk Roh;Hyun-Soo Zhang;In Sik Yun
    • Archives of Craniofacial Surgery
    • /
    • v.25 no.4
    • /
    • pp.179-186
    • /
    • 2024
  • Background: Auricle reconstruction is among the most challenging procedures in plastic and reconstructive surgery, and the choice of framework material is a critical decision for both surgeons and patients. This meta-analysis compared the outcomes of autologous auricle reconstruction using costal cartilage with those of alloplastic reconstruction using porous polyethylene implants. Methods: A literature review was conducted using the PubMed and Embase databases to retrieve articles published between January 2000 and June 2024. The outcomes analyzed included postoperative complications such as framework exposure, infection, skin necrosis, hematoma, and hypertrophic scars, as well as patient satisfaction. The proportions of reconstructive outcomes from each selected study were statistically analyzed using the "metaprop" function in R software. Results: Fourteen articles met our inclusion criteria. The group undergoing polyethylene implant reconstruction exhibited higher rates of framework exposure, infection, and skin necrosis, whereas the autologous reconstruction group experienced higher rates of hematoma and hypertrophic scars. Of all the complications, framework exposure was the only one to show a statistically significant difference between the two groups (p< 0.0001). In terms of patient satisfaction, those who underwent autologous cartilage reconstruction reported a higher rate of satisfaction, although this difference did not reach statistical significance in the meta-analysis (p= 0.076). Conclusion: There is no statistically significant difference in postoperative complications such as infection, hematoma, skin necrosis, and hypertrophic scars between auricle reconstructions using autologous costal cartilage and those using polyethylene implants. However, reconstructions with polyethylene implants show a significantly higher rate of framework exposure.

Three-dimensional computer navigation in the reconstruction of complex unilateral orbital fractures: evaluation and review of applications

  • Parampreet Singh Saini;Rajesh Kumar;Manu Saini;Tarush Gupta;Sunil Gaba;Ramesh Kumar Sharma
    • Archives of Craniofacial Surgery
    • /
    • v.25 no.4
    • /
    • pp.161-170
    • /
    • 2024
  • Background: The eyes are the central aesthetic unit of the face. Maxillofacial trauma can alter facial proportions and affect visual function with varying degrees of severity. Conventional approaches to reconstruction have numerous limitations, making the process challenging. The primary objective of this study was to evaluate the application of three-dimensional (3D) navigation in complex unilateral orbital reconstruction. Methods: A prospective cohort study was conducted over 19 months (January 2020 to July 2021), with consecutive enrollment of 12 patients who met the inclusion criteria. Each patient was followed for a minimum period of 6 months. The principal investigator carried out a comparative analysis of several factors, including fracture morphology, orbital volume, globe projection, diplopia, facial morphic changes, lid retraction, and infraorbital nerve hypoesthesia. Results: Nine patients had impure orbital fractures, while the remainder had pure fractures. The median orbital volume on the normal side (30.12 cm3; interquartile range [IQR], 28.45-30.64) was comparable to that of the reconstructed orbit (29.67 cm3; IQR, 27.92-31.52). Diplopia improved significantly (T(10)= 2.667, p= 0.02), although there was no statistically significant improvement in globe projection. Gross symmetry of facial landmarks was achieved, with comparable facial width-to-height ratio and palpebral fissure lengths. Two patients reported infraorbital hypoesthesia at presentation, which persisted at the 6-month follow-up. Additionally, five patients developed lower lid retraction (1-2 mm), and one experienced implant impingement at the infraorbital border. Conclusion: Our study provides level II evidence supporting the use of 3D navigation to improve surgical outcomes in complex orbital reconstruction.

Usability testing of a novel interlocking three-dimensional miniplate for mandibular angle fractures

  • Prasetyanugraheni Kreshanti;Aria Kekalih;Ahmad Jabir Rahyussalim;Sugeng Supriadi;Bambang Pontjo Priosoeryanto;Deni Noviana;Mendy Hatibie Oley;Chaula Luthfia Sukasah
    • Archives of Craniofacial Surgery
    • /
    • v.25 no.4
    • /
    • pp.171-178
    • /
    • 2024
  • Background: We developed a novel interlocking three-dimensional (3D) miniplate design with an adjustable configuration. As this device is new, surgeons must become familiar with its application. This study evaluated the usability and learning curves associated with the novel interlocking 3D miniplate for mandibular fracture fixation. Methods: The study participants, nine plastic surgeons, were asked to apply an interlocking 3D miniplate and a standard miniplate to polyurethane mandible models. The participants had completed the Basic Craniomaxillofacial Osteosynthesis course during residency and had operated on craniomaxillofacial fractures within the past 5 years. They were instructed to place the interlocking 3D miniplate three times and the standard miniplate once. We assessed the time required for implant placement, the comfort level of the surgeons, and the biomechanical stability of the plates. Biomechanical testing was conducted by subjecting the mandible to forces ranging from 10 to 90 N and the displacement was measured. Results: The results indicate increasing comfort with each attempt at placing the interlocking 3D miniplate, with a significant difference between the first and third attempts. Additionally, a reduction in application time was noted with repeated attempts, suggesting improved efficiency. Biomechanical tests showed comparable stability between the tested plates. Conclusion: Multiple attempts at applying the interlocking 3D miniplate resulted in increased comfort and reduced application time. These findings indicate that, despite its novelty, the interlocking 3D miniplate is relatively straightforward to apply and has a short learning curve. However, surgeons must have specific qualifications to ensure proper training and minimize errors during placement.

Anthropometric Analysis of Facial Foramina in Korean Population: A Three-Dimensional Computed Tomographic Study

  • Lim, Jung-Soo;Min, Kyung-Hee;Lee, Jong-Hun;Lee, Hye-Kyung;Hong, Sung-Hee
    • Archives of Craniofacial Surgery
    • /
    • v.17 no.1
    • /
    • pp.9-13
    • /
    • 2016
  • Background: Position of the facial foramina is important for regional block and for various maxillofacial surgical procedures. In this study, we report on anthropometry and morphology of these foramina using three-dimensional computed tomography (3D-CT) data. Methods: A retrospective review was performed for all patients who have undergone 3D-CT scan of the facial skeleton for reasons other than fracture or deformity of the facial skeleton. Anthropometry of the supraorbital, infraorbital, and mental foramina (SOF, IOF, MF) were described in relation to facial midline, inferior orbital margin, and inferior mandibular margin (FM, IOM, IMM). This data was analyzed according to sex and age. Additionally, infraorbital and mental foramen were classified into 5 positions based on the anatomic relationships to the nearest perpendicular dentition. Results: The review identified 137 patients meeting study criteria. Supraorbital foramina was more often in the shape of a foramen (62%) than that of a notch (38%). The supraorbital, infraorbital, and mental foramina were located 33.7 mm, 37.1 mm, and 33.7 mm away from the midline. The mean vertical distance between IOF and IOM was 13.4 mm. The mean distance between MF and IMM was 21.0 mm. The IOF and MF most commonly coincided with upper and lower second premolar dentition, respectively. Between the sex, the distance between MF and IMM was significantly higher for males than for female. In a correlation analysis, SOF-FM, IOF-FM and MF-FM values were significantly increased with age, but IOF-IOM values were significantly decreased with age. Conclusion: In the current study, we have reported anthropometric data concerning facial foramina in the Korean population, using a large-scale data analysis of three-dimensional computed tomography of facial skeletons. The correlations made respect to patient sex and age will provide help to operating surgeons when considering nerve blocks and periosteal dissections around the facial foramina.

Kirschner Wire Fixation for the Treatment of Comminuted Zygomatic Fractures

  • Kang, Dai-Hun;Jung, Dong-Woo;Kim, Yong-Ha;Kim, Tae-Gon;Lee, JunHo;Chung, Kyu Jin
    • Archives of Craniofacial Surgery
    • /
    • v.16 no.3
    • /
    • pp.119-124
    • /
    • 2015
  • Background: The Kirschner wire (K-wire) technique allows stable fixation of bone fragments without periosteal dissection, which often lead to bone segment scattering and loss. The authors used the K-wire fixation to simplify the treatment of laborious comminuted zygomatic bone fracture and report outcomes following the operation. Methods: A single-institution retrospective review was performed for all patients with comminuted zygomatic bone fractures between January 2010 and December 2013. In each patient, the zygoma was reduced and fixed with K-wire, which was drilled from the cheek bone and into the contralateral nasal cavity. For severely displaced fractures, the zygomaticofrontal suture was first fixated with a microplate and the K-wire was used to increase the stability of fixation. Each wire was removed approximately 4 weeks after surgery. Surgical outcomes were evaluated for malar eminence, cheek symmetry, K-wire site scar, and complications (based on a 4-point scale from 0 to 3, where 0 point is 'poor' and 3 points is 'excellent'). Results: The review identified 25 patients meeting inclusion criteria (21 men and 4 women). The mean age was 52 years (range, 15-73 years). The mean follow up duration was 6.2 months. The mean operation time was 21 minutes for K-wire alone (n=7) and 52 minutes for K-wire and plate fixation (n=18). Patients who had received K-wire only fixation had severe underlying diseases or accompanying injuries. The mean postoperative evaluation scores were 2.8 for malar contour and 2.7 for K-wire site scars. The mean patient satisfaction was 2.7. There was one case of inflammation due to the K-wire. Conclusion: The use of K-wire technique was associated with high patient satisfaction in our review. K-wire fixation technique is useful in patient who require reduction of zygomatic bone fractures in a short operating time.