• 제목/요약/키워드: ACFs

검색결과 749건 처리시간 0.028초

Heavy Metal Adsorption of Anodically Treated Activated Carbon Fibers in Aqueous Solution

  • Park, Soo-Jin;Kim, Young-Mi
    • Carbon letters
    • /
    • 제4권1호
    • /
    • pp.21-23
    • /
    • 2003
  • In this work, the effect of anodic oxidation treatment on Cr(VI) ion adsorption behaviors of activated carbon fibers (ACFs) was investigated. The aqueous solutions of 10 wt% $H_3PO_4$ and $NH_4OH$ were used for acidic and basic electrolytes, respectively. Surface characteristics and textural properties of ACFs were determined by XPS and $N_2$ adsorption at 77 K. The heavy metal adsorption of ACFs was conducted by ICP. As a result, the adsorption amount of the anodized ACFs was improved in order of B-ACFs > A-ACFs > pristine-ACFs. In case of the anodized treated ACFs, the specific surface area was decreased due to the pore blocking or pore destroying by acidic electrolyte. However, the anodic oxidation led to an increase of the Cr(VI) adsorption, which can be attributed to an increase of oxygen-containing functional groups, such as, carboxylic, lactonic, and phenolic groups. It was clearly found that the Cr(VI) adsorption was largely influenced by the surface functional groups, in spite of the reduced specific surface area of the ACFs.

  • PDF

Preparation and Application of ACFs Derived from the Petroleum Pitch and the Organometallic Compounds

  • Hong, Ik-Pyo;Ha, Baik-Hyon
    • Carbon letters
    • /
    • 제3권3호
    • /
    • pp.146-151
    • /
    • 2002
  • Activated carbon fibers were prepared from the petroleum isotropic pitch and organometallic compounds. The metalsvwere dispersed uniformly in the ACFs. The specific surface area and pore size distributions of metal containing ACFsvwere measured. The mesopores of ACFs were developed by Co, Ni, and Mn metals addition and the catalytic reactivityvof ACFs'SOx removal was increased by adding Ni and Pd metals. It was found that the mesopores did not work forvthe improvement of catalytic reactivity of ACFs' SOx removal with the blank experiment using the metal removedvACFs.

  • PDF

전해 구리 도금된 활성탄소섬유에 의한 NO의 촉매 환원반응 메커니즘 연구 (NO Adsorption and Catalytic Reduction Mechanism of Electrolytically Copper-plated Activated Carbon Fibers)

  • 박수진;장유신
    • Korean Chemical Engineering Research
    • /
    • 제40권6호
    • /
    • pp.664-668
    • /
    • 2002
  • 본 연구에서는 전해 도금되어진 활성탄소섬유(activated carbon fibers; ACFs)가 NO 환원거동에 미치는 영향에 대하여 고찰해보았다. 전해도금 시간이 증가함에 따라 탄소표면의 구리의 양은 점차 증가하였으나, 활성탄소섬유의 흡착 특성인 잘 발달된 비표면적 등의 기공구조는 약간씩 감소하는 경향을 보였다. 본 실험 결과, ACFs 및 ACFs/Cu 촉매 표면에서 $500^{\circ}C$로 NO를 반응시켰을 때 NO가 $N_2$$O_2$로 환원되는 것을 확인하였다. 특히, ACFs/Cu 촉매를 사용한 반응에서는 촉매반응 중 발생하는 산소를 촉매표면에서 잡아주는 역할을 하는 것으로 관찰되었다. 이는 NO환원에 있어서 ACFs와 ACFs/Cu 촉매 사이에 다른 기작이 있다는 것을 보여주는 것으로 생각되어진다.

ACF를 이용한 CCM (Compact Camera Module)용 COF(Chip-On-Flex) 실장 기술 및 신뢰성 연구 (A Study on the Assembly Process and Reliability of COF (Chip-On-Flex) Using ACFs (Anisotropic Conductive Films) for CCM (Compact Camera Module))

  • 정창규;백경욱
    • 마이크로전자및패키징학회지
    • /
    • 제15권2호
    • /
    • pp.7-15
    • /
    • 2008
  • 본 논문에서는 ACF를 이용한 CCM용 COF 어셈블리의 실장 기술을 연구하고 COF 어셈블리의 신뢰성 분석을 수행하였다. 열팽창계수, 모듈러스, 유리전이온도 등 경화 후 ACF의 열-기계적 물성들을 분석하였으며, ACF의 경화거동 결과를 바탕으로 COF 접합공정 온도 및 시간을 최적화하였으며, 도전입자의 변형 관찰 및 전기적 접촉 저항 측정을 통해 본딩 압력에 대한 최적화를 수행하였다. 또한 ACF 물질 특성이 COF어셈블리의 신뢰성에 미치는 영향을 알아보기 위해 열-싸이클 시험, 고온 유지 시험, 고온고습 시험을 수행하였다. 신뢰성 시험 수행 후 ACF를 이용한 COF 어셈블리의 신뢰성에 가장문제가 되고 있는 점은 열-싸이클 신뢰성 시험에서 나타난 ACF joint의 접촉 저항 증가 문제였고, 이는 ACF 자체의 열-기계적 물성과 밀접한 관계가 있음을 확인하였다.

  • PDF

Co-ACFs/TiO2 복합체의 제조 및 그의 메틸렌블루의 광분해 (Preparation of Co-ACFs/TiO2 composites and its photodegradation of methylene blue)

  • 오원춘;권호정;진명량;장봉군
    • 한국산학기술학회논문지
    • /
    • 제10권11호
    • /
    • pp.3031-3038
    • /
    • 2009
  • 코발트 적재된 활성탄소섬유(ACFs)는 이산화티탄($TiO_2$) 광촉매 반응을 촉진시키는 것을 발전되었다. Co-ACFs/$TiO_2$ 광촉매는 SEM, XRD, EDX 및 UV-vis 분광기를 사용하여 분석하였다. Co-ACFs/$TiO_2$ 광촉매에 대한 메틸렌불루(MB)의 분해 효과는 300분 반응해서 거의 100%를 도달하였다. 용액에 있는 MB 분자들은 ACFs의 흡착에 의해 $TiO_2$ 입자의 주위에 응축한다고 가정되었다. 그래서 이 광촉매 복합체는 MB 광분해에 대한 활성탄의 흡착성과 $TiO_2$의 광촉매 특성의 결합한 성능을 가지고 있다. 코발트가 전자 천이 효과를 가지고 있기 때문에 MB 용액의 광분해가 증가되는 것으로 판단된다.

Development of quantitative index evaluating anticancer or carcinogenic potential of diet: the anti-cancer food scoring system 1.0

  • Rim, Chai Hong
    • Nutrition Research and Practice
    • /
    • 제12권1호
    • /
    • pp.52-60
    • /
    • 2018
  • BACKGROUND/OBJECTIVE: Cancer is closely related to diet. One of the most reliable reports of the subject is the expert report from the World Cancer Research Fund & American Institute of Cancer Research (WCRF&AICR). However, majority of the studies including above were written with academic terms and in English. The aim of this study is to create a model, named Anti-Cancer Food Scoring System (ACFS), to provide a simple index of the anticancer potential of food. SUBJECTS/METHODS: We created ACFS codes of various food groups. The evidence of the ACFS codes was provided by the literature at a level comparable to that suggested in the WCRF&AICR report or from the WCRF&AICR report. The ACFS grade was calculated considering food group, cooking, and normalization. Application was performed for Koreans' 20 common meals, which encompass multinational recipes. RESULT: We calculated the ACFS grades of Koreans' 20 common meals. The results were not significantly different from the WCRF&AICR guidelines or information from the National Cancer Information Center of Korea. The grades were briefly interpreted as follows: grade S. ideal for cancer prevention; grade A. good for cancer prevention; grade B, might have anticancer potential; grade C, difficult to be regarded as preventive or carcinogenic; grade D, might against cancer prevention; grade E, probably against cancer prevention. CONCLUSIONS: The ACFS provides a simple index of anticancer potential of diets. This indicator can be useful for the people without expertise, and is effective in evaluating the diets including Asian foods. The ACFS can help design of future clinical or nutritional studies of cancer prevention.

과산화수소 용액에 담지 된 활성탄소섬유의 전자선 조사에 따른 일산화질소 가스 감응 (NO Gas Sensing of ACFs Treated by E-beam Irradiation in H2O2 Solution)

  • 이상민;박미선;정민정;이영석
    • 한국수소및신에너지학회논문집
    • /
    • 제27권3호
    • /
    • pp.298-305
    • /
    • 2016
  • In this study, we treated pitch-based activated carbon fibers (ACFs) in hydrogen peroxide using electron beam (E-beam) irradiation to improve nitrogen monoxide (NO) sensing ability as an electrode material of gas sensor. The specific surface area of ACFs treated by E-beam irradiation with 400 kGy increased from $885m^2/g$ (pristine) to $1160m^2/g$ without any changes in structural property and functional group. The increase in specific surface area of the E-beam irradiated ACFs enhanced NO gas sensing properties such as response time and sensitivity. When the ACFs irradiated with 400 kGy, response time was remarkably reduced from 360 s to 210 s and sensitivity was increased by 4.5%, compared to the pristine ACFs. These results demonstrate convincingly that surface modification of ACFs using E-beam in hydrogen peroxide solution can enhance textural properties of ACFs and NO gas sensing ability of gas sensor at room temperature.

Antibacterial Activity of Activated Carbon Fibers Containing Silver Metal

  • Park, Soo-Jin;Kim, Byung-Joo;Ryu, Seung-Kon
    • Carbon letters
    • /
    • 제4권3호
    • /
    • pp.140-145
    • /
    • 2003
  • Antibacterial behaviors of PAN-based activated carbon fibers (ACFs) containing silver metal were investigated. The effects of surface and pore structures of the ACFs were studied by $N_2$/77 K adsorption and D-R plot as a function of silver loading content. The antibacterial activities were investigated by a dilution test against Staphylococcus aureus (S. aureus; gram positive) and Klebsiella pnemoniae (K. pnumoniae; gram negative). As experimental results, the ACFs showed some decreases in specific surface areas, micropore volumes, and total pore volume with an increase of silver content. However, the antibacterial activities of the ACFs were strongly increased against S. aureus as well as K. pnumoniae, which could be attributed to the presence of antibacterial metal in the ACFs system.

  • PDF

Preparation of Activated Carbon Fibers from Cost Effective Commercial Textile Grade Acrylic Fibers

  • Bikshapathi, Mekala;Verma, Nishith;Singh, Rohitashaw Kumar;Joshi, Harish Chandra;Srivastava, Anurag
    • Carbon letters
    • /
    • 제12권1호
    • /
    • pp.44-47
    • /
    • 2011
  • Activated carbon fibers (ACFs) were prepared from cost effective commercial textiles through stabilization, carbonization, and subsequently activation by carbon dioxide. ACFs were characterized for surface area and pore size distribution by physical adsorption of nitrogen at 77 K. ACFs were also examined for various surface characteristics by scanning electron microscopy, Fourier transform infrared spectroscopy, and CHNO elemental analyzer. The prepared ACFs exhibited good surface textural properties with well developed micro porous structure. With improvement in physical strength, the commercial textile grade acrylic precursor based ACFs developed in this study may have great utility as cost effective adsorbents in environmental remediation applications.

Influence of Nickel Electroplating on Hydrogen Chloride Removal of Activated Carbon Fibers

  • Park, Soo-Jin;Jin, Sung-Yeol;Ryu, Seung-Kon
    • Carbon letters
    • /
    • 제5권4호
    • /
    • pp.186-190
    • /
    • 2004
  • In this work, a nickel metal (Ni) electroplating on the activated carbon fiber (Ni/ACFs) surfaces was carried out to remove the toxic hydrogen chloride (HCl) gas. The surface properties of the treated ACFs were determined by using nitrogen adsorption isotherms at 77 K, SEM, and X-ray diffraction (XRD) measurements. HCl removal efficiency was confirmed by a gas-detecting tube technique. As a result, the nickel metal contents on the ACF surfaces were increased with increasing the plating time. And, it was found that the specific surface area or the micropore volume of the ACFs studied was slightly decreased as increasing the plating time. Whereas, it was revealed that the HCl removal efficiency containing nickel metal showed higher efficiency values than that of untreated ACFs. These results indicated that the presence of nickel metal on the ACF surfaces played an important role in improving the HCl removal over the Ni/ACFs, due to the catalytic reactions between nickel and chlorine.

  • PDF