• Title/Summary/Keyword: ACCURACY

Search Result 34,318, Processing Time 0.061 seconds

Birth and Infant Death Reporting System via Computer Network (출생 및 영아사망 신고체계 및 전산정보체계 개발)

  • Park, Jung-Han;Lee, Young-Sook;Rhee, Jung-Ae;Cho, Hyun;Chung, Young-Hae;Park, Soon-Woo;Jun, Hae-Ri
    • Health Policy and Management
    • /
    • v.8 no.2
    • /
    • pp.125-148
    • /
    • 1998
  • Accurate vital statistics are essential for a national health planning and evaluation. Among various vital statistics, birth and death rates, and infant and matemal mortality rates together with the causes of death are the very basic ones for above purposes as well as for the maternal and child health management. These statistics are based on the birth and death reports. It is required by law to report every birth and death within one month after its occurrence. However, in case of a neonatal death occurring prior to the birth report, most of the birth and death are not reported. Thus accurate infant and maternal mortality rates are not available yet in Korea. The main objective of this study is to develop a birth and infant death reporting system via computer network. We designed a new birth report form based on the current form and data from the analysis of medical record forms of 14 hospitals. A new form is basically addition of essential medical information to the current birth report form. Since a revision of the rules and regulations related wtih the birth report is necessary to use a new form, we kept the current from intact to make it acceptable to the government office for a field trial. We also developed computer programs for data input for birth and death reports at a medical faciltiy, data processing for production of maternal and child health indices at a health center, and management of maternal and child health services including immunization and postantal care at health center. The birth certificate and birth report can be printed out at a medical facility. The computer packages were programmed by Borland Delphi 3.0 and can be run under Windows 95 system. We proposed a new birth and death reporting system via computer network after a field trial for data input, transmission, and processing. The medical and demographic data o birth and death at medical facilities will be sent to health centers directly via computer network. The health center will retain the medical data for analysis and forward only the data for birth and death reports required by current regulations to the Dong, Up, or Myun Office. Once the birth or death is reported via computer network to the Dong Office, then the Dong Office will notify the baby's mother of the birth report and request to submit the baby's name by mail. When the baby's name its submitted. the Dong Office will forward the birth reports to the Common Court and Statistics Agency in the same way as the current system, Upon the completion of birth registration of the Common Court, the court will issue the birth certificate to mother which will be used in lieu of the family record. The advantages of proposed birth and death reporting system via computer network ar as follows ; I) The accuracy, timing, and completeness of reporting will be improved and more accurate maternal and child health indices can be obtained, ii) The maternal and child health services of health center will be obtained, iii) Epidemiologic data for pregnancy and birth can be obtained, iv) Manpower for birth and death reporting will be saved.

  • PDF

Simultaneous HPLC Determination of Marker Compounds for the Standardization of Hedyotis diffusa (백운풀의 지표성분 설정 및 품질표준화를 위한 정량 분석법)

  • Bang, Han-Yeol;Yang, Eun-Ju;Kim, Jeong-Ah;Song, Kyung-Sik
    • Journal of Life Science
    • /
    • v.23 no.8
    • /
    • pp.1025-1031
    • /
    • 2013
  • From a 95% ethanolic extract of H. diffusa, four marker compounds (HD1~HD4) were isolated, which were relatively unique and exist in comparably high contents. The structures of marker compounds were identified as digitolutein (1), 2-hydroxy-3-methylanthraquinone (2), (E/Z)-6-O-p-coumaroyl scandoside methyl ester (4:1 mixture) (3), and (E/Z)-6-O-p-methoxycinnamoyl scandoside methyl ester (4:1 mixture) (4), respectively, on the basis of $^{13}C$ and $^1H$-NMR analyses. The calibration curves of marker compounds showed high linearity, as their correlation coefficient ($R^2$) were in the range of 0.9991~0.9999. In addition, the limit of detection (LOD) and the limit of quantification (LOQ) were $0.03{\sim}0.07{\mu}g/ml$ and $0.099{\sim}0.231{\mu}g/ml$, respectively. The intra-day/inter-day precision and accuracy were 0.23~2.00%/0.25~1.16% and 94.60~108.44%/94.73-110.23%, respectively. The optimal HPLC conditions for the simultaneous quantification of HD1~HD4 were as follows: stationary phase; Merck Chromolith RP-18e ($100{\times}4.6mm$, $5{\mu}m$), column temp.; room temperature, UV detection at 280 nm, flow rate; 2.0 ml/min, injection volume; $10{\mu}l$, mobile phase; start with the mixture of 80% solvent A ($H_2O$ containing 0.5% acetic acid) and 20% solvent B (methanol containing 0.5% acetic acid) and gradually decrease solvent A to 40% in 9 min., then retain this condition to 18 min. Under the HPLC condition, the four marker compounds 1~4 were successfully separated without any interference of other constituents. The results obtained in this study are expected to be helpful for the development of nutraceutics and natural medicines and for the quality control of this plant.

Introduction of Denitrification Method for Nitrogen and Oxygen Stable Isotopes (δ15N-NO3 and δ18O-NO3) in Nitrate and Case Study for Tracing Nitrogen Source (탈질미생물을 이용한 질산성 질소의 산소 및 질소 동위원소 분석법 소개)

  • Lim, Bo-La;Kim, Min-Seob;Yoon, Suk-Hee;Park, Jaeseon;Park, Hyunwoo;Chung, Hyen-Mi;Choi, Jong-Woo
    • Korean Journal of Ecology and Environment
    • /
    • v.50 no.4
    • /
    • pp.459-469
    • /
    • 2017
  • Nitrogen (N) loading from domestic, agricultural and industrial sources can lead to excessive growth of macrophytes or phytoplankton in aquatic environment. Many studies have used stable isotope ratios to identify anthropogenic nitrogen in aquatic systems as a useful method for studying nitrogen cycle. In this study to evaluate the precision and accuracy of denitrification bacteria method (Pseudomonas chlororaphis ssp. Aureofaciens ($ATCC^{(R)}$ 13985)), three reference (IAEA-NO-3 (Potassium nitrate $KNO_3$), USGS34 (Potassium nitrate $KNO_3$), USGS35 (Sodium nitrate $KNO_3$)) were analyzed 5 times repeatedly. Measured the ${\delta}^{15}N-NO_3$ and ${\delta}^{18}O-NO_3$ values of IAEA-NO-3, USGS 34 and USGS35 were ${\delta}^{15}N:4.7{\pm}0.1$${\delta}^{18}O:25.6{\pm}0.5$‰, ${\delta}^{15}N:-1.8{\pm}0.1$${\delta}^{18}O:-27.8{\pm}0.4$‰, and ${\delta}^{15}N:2.7{\pm}0.2$${\delta}^{18}O:57.5{\pm}0.7$‰, respectively, which are within recommended values of analytical uncertainties. Also, we investigated isotope values of potential nitrogen source (soil, synthetic fertilizer and organic-animal manures) and temporal patterns of ${\delta}^{15}N-NO_3$ and ${\delta}^{18}O-NO_3$ values in river samples during from May to December. ${\delta}^{15}N-NO_3$ and ${\delta}^{18}O-NO_3$ values are enriched in December suggesting that organic-animal manures should be one of the main N sources in those areas. The current study clarifies the reliability of denitrification bacteria method and the usefulness of stable isotopic techniques to trace the anthropogenic nitrogen source in freshwater ecosystem.

Embryo Transfer with Sex-Determined Hanwoo Embryos Produced by In-vitro Fertilization (성감별된 한우 체외수정란의 수정란 이식)

  • 김용준;이창민;정구남;이해리;조성우;김용수;신동수;홍유미;유일정
    • Journal of Embryo Transfer
    • /
    • v.18 no.2
    • /
    • pp.97-108
    • /
    • 2003
  • In-vitro fertilized Hanwoo embryos were biopsied for sex determination by PCR. Biopsied embryos were incubated for 1∼2 hours for the recovery. Those sexed Hanwoo embryos were transferred to 49 Hanwoo and 16 Holstein recipients from February 2000 to February 2001. Of 65 recipients, 14 cows(12 Hanwoo and 2 Holstein) delivered the same offspring as sex-determined by PCR, therefore the conception rate was 21.5%. 1. Total 65 embryos(male 35, female 30) were transferred to recipients, and 14 calves (male 6, female 8) were delivered. In comparison between sex by PCR method and sex of calves born after embryo transfer, the accuracy of sex determination was 100.0%. 2. The conception rate after transfer with biopsied embryo between Hanwoo and Holstein was 24.5% and 12.5% 3. The conception rate after transfer with biopsied embryo between fresh and frozen-thawed embryos was 23.5% and 14.3%. 4. The conception rate according to the season when embryo was transferred was 11.8, 29.4, 23.5 and 20.0% for spring, summer, autumn and winter, respectively. 5. The conception rate according to embryo quality after biopsy was 41.7, 30.0 and 0.0% for excellent, good and fair quality. 6. The conception rate according to thickness of uterine horn was 71.4, 18.9, 11.8 and 0.0% for 0, +, ++ and +++ thickness. 7. The conception rate according to the site in the uterine hem where embryo was put was 30.0, 20.0 and 10.0% for cranial, mid, and caudal part of uterine horn. 8. The conception rate according to the quality of corpus luteum ipsilateral to the uterine horn where embryos was transferred was 41.2, 14.3 and 15.4% for excellent, good and fair quality. 9. The conception rate according to the time required for embryo transfer was 18.2, 30.0, 30.0, 0.0 and 25.0% for 10, 15, 20, 25 and 30 minutes. 10. The conception rate according to parity of recipients was 26.5, 19.1, 14.3 and 0.0% for the primiparous, the 2nd parous, the 3rd parous and the 4th parous recipients. These results indicated that fresh embryos are more demanded than frozen-thawed embryos for good conception rate in embryo transfer with biopsied-sexed embryo. Also, it was indicated that we should consider embryo-recovering condition, recipient's uterine thickness, transfer site in uterine horn, quality of corpus luteum, time required for transfer and parity of recipient to achieve good conception rate in ET with biopsied-sexed embryos.

Monitoring of Malachite Green in Freshwater Fish using LC-MS/MS (LC-MS/MS를 이용한 담수 어류 중 말라카이트 그린 분석)

  • Choi, Hee-jin;Yuk, Dong-Hyun;Park, Young-Ae;Jung, Bo-Kyeng;Hong, Mi-Sun;Yoon, Yong-Tae;Yi, Hye-Jin;Kim, Youn-Cheon;Park, Sung-Kyu;Kim, Moo-Sang;Jung, Kweon
    • Journal of Food Hygiene and Safety
    • /
    • v.31 no.1
    • /
    • pp.15-20
    • /
    • 2016
  • Malachite green was measured in 200 freshwater fish collected from local markets in Seoul using HPLC-DAD and LC-MS/MS. LC-MS/MS method was validated by linearity, accuracy, precision and limits of detection and quantification according to the CODEX's recommendation and HPLC-DAD method was applied according to the Food Code. Malachite green levels above the quantification limit of the LC-MS/MS were determined 18.5% (37) but just 1 fish was shown to contain malachite green by HPLC-DAD. Of 83 domestic fish, 21 fish were detected malachite green (25.3%). Of 117 fish from China, just 16 fish were detected malachite green (13.4%). In detection rate by species carp (35.0%), Crucian carp (30.4%), cat fish (28.0%), Korean bull head (23.8%), snake head (20.0%), eel (10.5%) and loach (7.8%) were in order. Especially, fish collected at summer were shown to contain malachite green frequently; the detection rate was 54.8%.

Estimation of river discharge using satellite-derived flow signals and artificial neural network model: application to imjin river (Satellite-derived flow 시그널 및 인공신경망 모형을 활용한 임진강 유역 유출량 산정)

  • Li, Li;Kim, Hyunglok;Jun, Kyungsoo;Choi, Minha
    • Journal of Korea Water Resources Association
    • /
    • v.49 no.7
    • /
    • pp.589-597
    • /
    • 2016
  • In this study, we investigated the use of satellite-derived flow (SDF) signals and a data-based model for the estimation of outflow for the river reach where in situ measurements are either completely unavailable or are difficult to access for hydraulic and hydrology analysis such as the upper basin of Imjin River. It has been demonstrated by many studies that the SDF signals can be used as the river width estimates and the correlation between SDF signals and river width is related to the shape of cross sections. To extract the nonlinear relationship between SDF signals and river outflow, Artificial Neural Network (ANN) model with SDF signals as its inputs were applied for the computation of flow discharge at Imjin Bridge located in Imjin River. 15 pixels were considered to extract SDF signals and Partial Mutual Information (PMI) algorithm was applied to identify the most relevant input variables among 150 candidate SDF signals (including 0~10 day lagged observations). The estimated discharges by ANN model were compared with the measured ones at Imjin Bridge gauging station and correlation coefficients of the training and validation were 0.86 and 0.72, respectively. It was found that if the 1 day previous discharge at Imjin bridge is considered as an input variable for ANN model, the correlation coefficients were improved to 0.90 and 0.83, respectively. Based on the results in this study, SDF signals along with some local measured data can play an useful role in river flow estimation and especially in flood forecasting for data-scarce regions as it can simulate the peak discharge and peak time of flood events with satisfactory accuracy.

An Analysis of Soil Pressure Gauge Result from KHC Test Road (시험도로 토압계 계측결과 분석)

  • In Byeong-Eock;Kim Ji-Won;Kim Kyong-Ha;Lee Kwang-Ho
    • International Journal of Highway Engineering
    • /
    • v.8 no.3 s.29
    • /
    • pp.129-141
    • /
    • 2006
  • The vertical soil pressure developed in the granular layer of asphalt pavement system is influenced by various factors, including the wheel load magnitude, the loading speed, and asphalt pavement temperature. This research observed the distribution of vertical soil pressure in pavement supporting layer by investigating measured data from soil pressure gage in the KHC Test Road. The existing specification of subbase and subgrade compaction was also evaluated with measured vertical pressure. The finite element analysis was conducted to verify the accuracy of results with measured data because it can maximize research capacity without significant field test. The test data was collected from A5, A7, A14, and A15 test sections at August, September, and November 2004 and August 2005. Those test sections and test data were selected because they had best quality. The size of influence area was evaluated and the vertical pressure variation was investigated with respect to load level, load speed, and pavement temperature. The lower speed, higher load level, and higher pavement temperature increased the vertical pressure and reduced the area of influence. The finite element result showed the similar trend of vertical pressure variation in comparison with measured data. The specification of compaction quality for subbase and subgrade is higher than the level of vertical pressure measured with truck load so that it should be lurker investigated.

  • PDF

Measurement of Image Quality According to the Time of Computed Radiography System (시간에 따르는 CR장비의 영상의 질평가)

  • Son, Soon-Yong;Choi, Kwan-Woo;Kim, Jung-Min;Jeong, Hoi-Woun;Kwon, Kyung-Tae;Hwang, Sun-Kwang;Lee, Ik-Pyo;Kim, Ki-Won;Jung, Jae-Yong;Lee, Young-Ah;Son, Jin-Hyun;Min, Jung-Whan
    • Journal of radiological science and technology
    • /
    • v.38 no.4
    • /
    • pp.365-374
    • /
    • 2015
  • The regular quality assurance (RQA) of X-ray images is essential for maintaining a high accuracy of diagnosis. This study was to evaluate the modulation transfer function (MTF), the noise power spectrum (NPS), and the detective quantum efficiency (DQE) of a computed radiography (CR) system for various periods of use from 2006 to 2015. We measured the pre-sampling MTF using the edge method and RQA 5 based on commission standard international electro-technical commission (IEC). The spatial frequencies corresponding to the 50% MTF for the CR systems in 2006, 2009, 2012 and 2015 were 1.54, 1.14, 1.12, and $1.38mm^{-1}$, respectively and the10% MTF for 2006, 2009, 2012, and 2015 were 2.68, 2.44, 2.44, and $2.46mm^{-1}$, respectively. In the NPS results, the CR systems showed the best noise distribution in 2006, and with the quality of distributions in the order of 2015, 2009, and 2012. At peak DQE and DQE at $1mm^{-1}$, the CR systems showed the best efficiency in 2006, and showed better efficiency in order of 2015, 2009, and 2012. Because the eraser lamp in the CR systems was replaced, the image quality in 2015 was superior to those in 2009 and 2012. This study can be incorporated into used in clinical QA requiring performance and evaluation of the performance of the CR systems.

Consideration on Measured Patients Dose of Three-Dimensional and Four-Dimensional Computer Tomography when CT-Simulation to Radiation Therapy (방사선치료를 위한 CT 검사 시 3DCT와 4DCT에 대한 피폭선량 고찰)

  • Park, Ryeong-Hwang;Kim, Min-Jung;Lee, Sang-Kyu;Park, Kwang-Woo;Jeon, Byeong-Cheol;Cho, Jeong-Hee;Yoo, Beong-Gyu;Lee, Jong-Seok
    • Journal of radiological science and technology
    • /
    • v.34 no.4
    • /
    • pp.341-349
    • /
    • 2011
  • This study was to measure the patient dose difference between 3D treatment planning CT and 4D respiratory gating CT. Study was performed with each 10 patients who have lung and liver cancer for measured patient exposure dose by using SOMATON SENSATION OPEN(SIMENS, GERMANY). CTDIvol and DLP value was used to analyze patient dose, and actual dose was measured in the location of liver and kidney for abdominal examination and lung, heart and spinal cord for chest examination. Rando phantom were used for the experiment. OSLD was used for in-vitro and in-vivo dosimetry. Increasing overall actual dose in 4D respiratory gated CT-simulation using OSLD increase the dose by 5.5 times for liver cancer patients and 6 times for lung cancer patients. In CT simulation of 10 lung cancer patients, CTDIvol value was increased by 5.7 times and DLP 2.4 times. For liver cancer patients, CTDIvol was risen by 3.8 times and DLP 1.6 times. The accuracy of treatment volume could be increased in 4D CT planning for position change due to the breaths of patient in the radiation therapy. However, patients dose was increased in 4D CT than 3D CT. In conclusion, constant efforts is required to reduce patients dose by reducing scan time and scan range.

Determination of Sulfur Requirement to Adjust pH of Alkaline Soil by Buffer Curve Method (알칼리성 토양 pH 교정시 완충곡선법을 이용한 황 시용량 결정)

  • Lee, In-Bog;Lim, Jae-Hyun;Yiem, Myoung-Soon
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.33 no.6
    • /
    • pp.405-415
    • /
    • 2000
  • To determine application rate of elemental sulfur to adjust pH of alkaline soil, buffer curve method was investigated. The elemental sulfur required to control pH 8.3 to pH 6.3 by buffer curve calculation was treated in two soils of silty loam and sandy loam, and the sulfur-mixed soils were moistened with 50% of water holding capacity during incubation of 6 weeks at $30^{\circ}C$. Soil pH was lowered with incubation and reached to target point after 4 weeks of incubation, and elemental sulfur was oxidised entirely to sulfate. This means that buffer curve has the accuracy to determine sulfur application rate in alkaline soil. However it is estimated that application rate of sulfur should be carefully determined in the field scale. Excess application of elemental sulfur resulted in extremely low soil pH and caused the hinderance of lettuce growth by nutritional imbalance and ion toxicity. To simplify the determination procedure of sulfur requirement, buffer curve method by addition of 0.1N-HCl solution as unit of mL was developed, it was compared with theroutine methods which diluted $H_2SO_4$ solution and $Ca(OH)_2$ are added as cmolc per kg soil to adjust each pH step. Buffer capacities, cmolc kg $soil^{-1}$ $pH^{-1}$, calculated from two buffer curves were not significantly different. The result indicates that buffer curve method by 0.1N-HCl can be used to adjust high pH of alkaline soil.

  • PDF