• Title/Summary/Keyword: AC7A

Search Result 872, Processing Time 0.028 seconds

Expression of a Fusion Protein with Cry1Ac Protein and a Scorpion Insect Toxin in Acrystalliferous Bacillus thuringiensis Strain

  • Roh, Jong-Yul;Li, Ming-Shun;Chang, Jin-Hee;Park, Jae-Young;Shim, Hee-Jin;Shin, Sang-Chul;Boo, Kyung-Saeng;Je, Yeon-Ho
    • International Journal of Industrial Entomology and Biomaterials
    • /
    • v.8 no.1
    • /
    • pp.89-93
    • /
    • 2004
  • Expression of a fusion protein between B. thuringiensis crystal protein, Cry1Ac1 and a scorpion insect toxin (AaIT, Androctonus australis Hector insect toxin) in acrystalliferous B. thuringiensis strain (Cry-B strain) was examined. The cry 1Ac1 gene was cloned in B. thuringiensis-E coli shuttle vector, pHT3101, under the control of the native cry 1Ac1 gene promoter (pProAc) and a gene encoding AaIT was inserted in XhoI site in the middle of the cry 1Ac1 gene (pProAc-ScoR). B. thuringiensis Cry-B strain carrying pProAc-ScoR (PyoAc-ScoR/CB) produced an inclusion body of irregular shape and the expressed fusion protein is approximately 65 kDa in size. Sporulated cells and spore-crystal mixtures of ProAc-ScoR/CB had insecticidal activity against Plutella xylostella larvae, showing $LT_50$ of ProAc-ScoR/CB (22.59 hrs) lower than that of ProAc/CB (30.06 hrs) at $1{\times}{10^7} {CEU/cm^2}$. These results suggest that the fusion protein including a B. thuringiensis crystal protein and an AaIT may be functionally expressed in B. thupingiensis. Moreover, we verified the additive toxicity of AaIT, which is a new feasible candidate for insect control.

As(III) Oxidation and Phenol Adsorption by the Activated Carbon Impregnated with Mn Oxide (망간산화물이 첨착된 활성탄에 의한 페놀흡착 및 비소(III) 산화)

  • Yu, Mok-Ryun;Yang, Jae-Kyu;Chang, Yoon-Young
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.30 no.4
    • /
    • pp.423-429
    • /
    • 2008
  • Application of manganese-impregnated activated carbon(Mn-AC) in the treatment of synthetic wastewater containing both organic and inorganic contaminants was investigated. Phenol and As(III) was used as representative organic and inorganic contaminants, respectively. When the stability of Mn-AC at acidic condition was evaluated with variation of solution pH ranging from 2 to 4, Mn-AC was unstable below pH 3, while negligible dissolution of Mn was observed above pH 4. This stability test suggests a plausible applicability of Mn-AC in the treatment of wastewater above pH 4. Compared to AC-alone, the adsorption rates of phenol as well as adsorbed amounts of phenol by Mn-AC were slightly decreased due to the decrease of the surface area by impregnation. The maximum adsorbed amount of phenol by Mn-AC was corresponds to 75% of that by AC-alone from the adsorption isotherm study. The oxidation efficiency of As(III) by Mn-AC was greater than that by AC-alone at lower pHs while reverse trend was observed as pH increased above 7. From this work, it was found that Mn-AC could be used in the simultaneous treatment of both phenol and As(III).

Production of the Eggs with Abnormal Shape from the Domestic Silkworm, Bombyx mori, Infected with Autographa californica Nuclear Polyhedrosis Virus

  • Lee, Sang-Mong;Park, Nam-Sook;Park, Hye-Jin;Yun, Eun-Young;Kang, Seok-Woo;Kim, Keun-Young;Sohn, Hung-Dae;Jin, Byung-Rae
    • International Journal of Industrial Entomology and Biomaterials
    • /
    • v.1 no.2
    • /
    • pp.111-114
    • /
    • 2000
  • The female pupae of the silkworms Bombyx mori, were injected with recombinant Autographa californica nuclear polyhedrosis virus (AcNPV) expressing green fluorescent protein (GFP) by percutaneous inoculation. When the 4 day-old female pupae were injected with 1x10$^{7}$ or 2${\times}$10$^{7}$ plaque forming units (pfu) of the recombinant AcNPV, oviposited number and egg weight were significantly decreased. Furthermore, the shape of the eggs was obviously divides into normal and abnormal shapes. The percentage of the eggs with an abnormal shape was 7.8% and 57.1% at 1${\times}$10$^{7}$ and 2${\times}$10$^{7}$ pfu inoculation, respectively. PCR analysis of the genomic DNA extracted from the eggs revealed that gfp and AcNPV ecdysteroid UDP-glucosyltransferase genes were amplified from both types of eggs with normal and abnormal shapes. The results demonstrate that AcNPV DNA, and gfp gene cloned into the AcNPV genome, injected in pupal stage were transmitted to eggs and remained stable through at least next generation.

  • PDF

An Approach to a Speed Estimation Method to Remove Speed Sensor of Underwater Robot's AC Drive Systems (수중로봇용 AC구동시스템의 속도센서 제거를 위한 속도추정법 연구)

  • 전봉환;임용곤;이판묵
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 1998.05a
    • /
    • pp.371-376
    • /
    • 1998
  • This paper describes an approach to a speed estimation method to remove speed sensor of underwater robot's AC drive systems. AC motors have been widely used in the field of underwater robot's manipulator or propulsion system. Most of these AC motors for underwater use have usually filled oil to compensate the high pressure in deep-sea operation, where a resolver is adopted to feed back the speed of rotor But this kind of speed feedback devices gives rise to some defects arising from their mechanical complexity and numerous signal lines; a resolver needs 6 or 7 signal lines for proper operation. This paper presents a speed estimation method to improve these problems of induction motor, which is adopted as a prototype of AC motor. The proposed speed estimation method is based on the RFO(rotor flux orientation) vector control method of voltage-fed AC drives. Using the controller of voltage-fed AC drives, it is unnecessary to measure the voltage for the estimation of rotor speed, which reduces the effects of measurement error Numerical simulation is carried out to investigate the validity of the method and the effects of rotors resistance variation.

  • PDF

A Study on the Development of Low Frequency Electronic Ignition Trans for Large Combustors (대형연소기에 적용되는 저주파 전자식 점화 트랜스 개발에 관한 연구)

  • Lee, Ho-kyun;Park, Jung-cheul
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.15 no.4
    • /
    • pp.223-229
    • /
    • 2022
  • In this paper, the ignition trans used in boilers was studied. Regardless of the change in the ignition rod length and the ignition rod gap, the output frequency was measured between 59.5 and 61.3 Hz, and it was found that the low frequency circuit operated normally. When the ignition rod gap changed by 2 to 10 mm, the ignition rod length was measured from 2.8A to 3.45A at 30cm. The ignition rod length was measured from 9.37 A to 14.5 A at 500 cm and from 13.2 A to 32.6 A at 1000 cm. As the ignition rod length and the ignition rod gap increased, the current increased. As a result of measuring the secondary coil output voltage. The ignition rod length was measured from AC 0.84 kV to AC 1.75 kV at 30 cm, AC 1.17 kV to AC 1.944 at 500 cm, and AC 1.4 kV to AC 7.18 kV at 1000 cm. As the ignition rod length and the ignition rod gap increased, the output voltage of the secondary coil also increased. As a result of measuring the output voltage of the ignition trans, the ignition rod length was measured from DC 1.11 kV to DC 1.57 kV at 30cm, DC 2.49 kV to DC 3.72 kV at 500cm, and DC 3.78 kV to DC 9.42 kV at 1000cm, and the power voltage increased as the ignition rod length and interval increased.

Effects of PNF Technique on Delayed Onset Muscle Soreness After Eccentric Exercise

  • Lee, Su-Young;Yi, Chung-Hwi;Choi, Mun-Suk
    • Physical Therapy Korea
    • /
    • v.14 no.4
    • /
    • pp.1-6
    • /
    • 2007
  • This study examined the effects of hold-relax with agonist contraction (HR-AC) on the symptoms of delayed onset muscle soreness (DOMS) induced by intensive eccentric exercise of the non-dominant biceps brachii. Ten men (mean age=26.7 yrs, mean height=172.1 cm, mean weight=66.2 kg) and ten women (mean age=27.4 yrs, mean height=165.9 cm, mean weight=60.7 kg) who had not participated in a regular exercise program for the upper extremities in the previous six months were randomly assigned to one of two experimental groups: the HR-AC group, or the control group. We measured joint range of motion (ROM), maximal voluntary isometric contraction (MVIC), and muscle soreness before eccentric exercise, and 24, 48, and 72 hours after eccentric exercise. The subjects in the HR-AC group received the HR-AC technique in the non-dominant biceps brachii. The HR-AC technique was applied 24 and 48 hours after eccentric exercise. There was no significant difference between the HR-AC and the control group. However, the HR-AC group, compared to the control group, had a significant difference between the time points of the various parameters. Increased ROM (p<.05), decreased muscle soreness (p<.05), and reduced MVIC (p<.05) were found in the HR-AC group after 72 hours. Decreased ROM (p<.05) and MVIC (p<.05), and increased muscle soreness (p<.05) were observed in the control group. These findings suggest that the HR-AC technique effectively reduces muscle soreness and increases ROM 72 hours after eccentric exercise.

  • PDF

Usefulness Evaluation of Artifacts by Bone Cement of Percutaneous Vertebroplasty Performed Patients and CT Correction Method in Spine SPECT/CT Examinations (척추 뼈 SPECT/CT검사에서 경피적 척추성형술 시행 환자의 골 시멘트로 인한 인공물과 CT보정방법의 유용성 평가)

  • Kim, Ji-Hyeon;Park, Hoon-Hee;Lee, Juyoung;Nam-Kung, Sik;Son, Hyeon-Soo;Park, Sang-Ryoon
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.18 no.1
    • /
    • pp.49-61
    • /
    • 2014
  • Purpose: With the aging of the population, the attack rate of osteoporotic vertebral compression fracture is in the increasing trend, and percutaneous vertebroplasty (PVP) is the most commonly performed standardized treatment. Although there is a research report of the excellence of usefulness of the SPECT/CT examination in terns of the exact diagnosis before and after the procedure, the bone cement material used in the procedure influences the image quality by forming an artifact in the CT image. Therefore, the objective of the research lies on evaluating the effect the bone cement gives to a SPECT/CT image. Materials and Methods: The images were acquired by inserting a model cement to each cylinder, after setting the background (3.6 kBq/mL), hot cylinder (29.6 kBq/mL) and cold cylinder (water) to the NEMA-1994 phantom. It was reconstructed with Astonish (Iterative: 4 Subset: 16), and non attenuation correction (NAC), attenuation correction (AC+SC-) and attenuation and scatter correction (AC+SC+) were used for the CT correction method. The mean count by each correction method and the count change ratio by the existence of the cement material were compared and the contrast recovery coefficient (CRC) was obtained. Additionally, the bone/soft tissue ratio (B/S ratio) was obtained after measuring the mean count of the 4 places including the soft tissue(spine erector muscle) after dividing the vertebral body into fracture region, normal region and cement by selecting the 20 patients those have performed PVP from the 107 patients diagnosed of compression fracture. Results: The mean count by the existence of a cement material showed the rate of increase of 12.4%, 6.5%, 1.5% at the hot cylinder of the phantom by NAC, AC+SC- and AC+SC+ when cement existed, 75.2%, 85.4%, 102.9% at the cold cylinder, 13.6%, 18.2%, 9.1% at the background, 33.1%, 41.4%, 63.5% at the fracture region of the clinical image, 53.1%, 61.6%, 67.7% at the normal region and 10.0%, 4.7%, 3.6% at the soft tissue. Meanwhile, a relative count reduction could be verified at the cement adjacent part at the inside of the cylinder, and the phantom image on the lesion and the count increase ratio of the clinical image showed a contrary phase. CRC implying the contrast ratio and B/S ratio was improved in the order of NAC, AC+SC-, AC+SC+, and was constant without a big change in the cold cylinder of the phantom. AC+SC- for the quantitative count, and AC+SC+ for the contrast ratio was analyzed to be the highest. Conclusion: It is considered to be useful in a clinical diagnosis if the application of AC+SC+ that improves the contrast ratio is combined, as it increases the noise count of the soft tissue and the scatter region as well along with the effect of the bone cement in contrast to the fact that the use of AC+SC- in the spine SPECT/CT examination of a PVP performed patient drastically increases the image count and enables a high density of image of the lesion(fracture).

  • PDF

The Stability Constant of Transition and Lanthanide Metal Ions Complexes with 15 Membered Macrocyclic Azacrown Ligands (거대고리 아자크라운화합물과 전이금속 및 란탄족금속이온의 착물의 안정도)

  • Hong, Choon-Pyo;Choi, Yong-Gu;Choppin, G.R.
    • Journal of the Korean Chemical Society
    • /
    • v.48 no.6
    • /
    • pp.577-582
    • /
    • 2004
  • The azacrown compounds, 1,4-dioxa-7,10,13-triazacyclopentadecane-N,N',N''-triacetic acid, $N-ac_3[15]aneN_3O_2(II_a)$ and 1,4-dioxa-7,10,13-triazacyclopentadecane-N,N',N''-tripropioc acid, $N-pr_3[15]aneN_3O_2(II_b)$ were synthesized by modified methods. Potentiometry was used to determine the protonation constant of the $N-ac_3[15]aneN_3O_2\;and\;N-pr_3[15]aneN_3O_2$. The stability constants of complexes of the trivalent metal ions of $Ce^{3+},\;Eu^{3+},Gd^{3+},and\;Yb^{3+}$ and divalent metal ions of $Co^{2+},\;Ni^{2+},\;Cu^{2+},\;and\;Zn^{2+}$ with the ligands $N-ac_3[15]aneN_3O_2\;and\;N-pr_3[15]aneN_3O_2$ have been determined at $25{\pm}0.1^{\circ}C$ in 0.1 M $NaClO_4$ solution by potentiometric methods. The metal ion affinities of the two triazamacrocyclic ligands with three pendant acetate or propionate groups are compared to those obtained for the similar ligands, 1,7-dioxa-4,10,13-triazacyclopentadecane-N,N',N''-triacetic acid, and 1,7-dioxa-4,10,13- triazacyclopentadecane-N,N',N''-tripropioc acid. The trends in stability of complexes for different metal ions due to changes in the nitrogen position of the donor atoms of the ligand are discussed.

A Study on PFC AC-DC Converter of High Efficiency added in Electric Isolation (절연형 고효율 PFC AC-DC 컨버터에 관한 연구)

  • Kwak, Dong-Kurl;Kim, Sang-Roan
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.7
    • /
    • pp.1349-1355
    • /
    • 2009
  • This paper is studied on a novel power factor correction (PFC) AC-DC converter of high efficiency by soft switching technique. The input current waveform in the proposed converter is got to be a sinusoidal form composed of many a discontinuous pulse in proportion to the magnitude of a ac input voltage under the constant switching frequency. Therefore, the input power factor is nearly unity and the control method is simple. The proposed converter adding an electric isolation operates with a discontinuous current mode (DCM) of the reactor in order to obtain some merits of simpler control, such as fixed switching frequency, without synchronization control circuit used in continuous current mode (CCM). To achieve the soft switching (ZCS or ZVS) of control devices, the converter is constructed with a new loss-less snubber for a partial resonant circuit. It is that the switching losses are very low and the efficiency of the converter is high, Particularly, the stored energy in a loss-less snubber capacitor recovers into input side and increases input current from a resonant operation. The result is that the input power factor of the proposed converter is higher than that of a conventional PFC converter. This paper deals mainly with the circuit operations, theoretical, simulated and experimental results of the proposed PFC AC-DC converter in comparison with a conventional PFC AC-DC converter.

Two-Switch Auxiliary Resonant DC Link Snubber-Assisted Three-Phase Soft Switching PWM Sinewave Power Conversion System with Minimized Commutation Power Losses

  • Nagai, Shinichiro;Sato, Shinji;Ahmed, Tarek;Nakaoka, Mutsuo
    • Journal of Power Electronics
    • /
    • v.3 no.4
    • /
    • pp.249-258
    • /
    • 2003
  • This paper presents a high-efficient and cost effective three-phase AC/DC-DC/AC power conversion system with a single two-switch type active Auxiliary Resonant DC Link (ARDCL) snubber circuit, which can minimize the total power dissipation. The active ARDCL snubber circuit is proposed in this paper and its unique features are described. Its operation principle in steady-state is discussed for the three phase AC/DC-DC/AC converter, which is composed of PWM rectifier as power factor correction (PFC) converter, sinewave PWM inverter. In the presented power converter system not only three-phase AC/DC PWM rectifier but also three-phase DC/AC inverter can achieve the stable ZVS commutation for all the power semiconductor devices. It is proved that the proposed three-phase AC/DC-DC/AC converter system is more effective and acceptable than the previous from the cost viewpoint and high efficient consideration. In addition, the proposed two-switch type active auxiliary ARDCL snubber circuit can reduce the peak value of the resonant inductor injection current in order to maximize total system actual efficiency by using the improved DSP based control scheme. Moreover the proposed active auxiliary two-switch ARDCL snubber circuit has the merit so that there is no need to use any sensing devices to detect the voltage and current in the ARDCL sunbber circuit for realizing soft-switching operation. This three-phase AC/DC-DC/AC converter system developed for UPS can achieve the 1.8% higher efficiency and 20dB lower conduction noise than those of the conventional three-phase hard-switching PWM AC/DC-DC/AC converter system. It is proved that actual efficiency of the proposed three-phase AC/DC-DC/AC converter system operating under a condition of soft switching is 88.7% under 10kw output power.