• 제목/요약/키워드: AC permeability

검색결과 45건 처리시간 0.026초

Microstructural Change and Magnetic Properties of Nanocrystalline Fe-Si-B-Nb-Cu Based Alloys Containing Minor Elements

  • Nam, Seul-Ki;Moon, Sun-Gyu;Sohn, Keun Yong;Park, Won-Wook
    • Journal of Magnetics
    • /
    • 제19권4호
    • /
    • pp.327-332
    • /
    • 2014
  • The effect of minor element additions (Ca, Al) on microstructural change and magnetic properties of Fe-Nb-Cu-Si-B alloy has been investigated, in this paper. The Fe-Si-B-Nb-Cu(-Ca-Al) alloys were prepared by arc melting in argon gas atmosphere. The alloy ribbons were fabricated by melt-spinning, and heat-treated under a nitrogen atmosphere at $520-570^{\circ}C$ for 1 h. The soft magnetic properties of the ribbon core were analyzed using the AC B-H meter. A differential scanning calorimetry (DSC) was used to examine the crystallization behavior of the amorphous alloy ribbon. The microstructure was observed by X-ray diffraction (XRD), transmission electron microscope (TEM) and scanning electron microscope (SEM). The addition of Ca increased the electrical resistivity to reduce the eddy current loss. And the addition of Al decreased the intrinsic magnetocrystalline anisotropy $K_1$ resulting in the increased permeability. The reduction in the size of the ${\alpha}$-Fe precipitates was observed in the alloys containing of Ca and Al. Based on the results, it can be concluded that the additions of Ca and Al notably improved the soft magnetic properties such as permeability, coercivity and core loss in the Fe-Nb-Cu-Si-B base nanocrystalline alloys.

Nafion-Sulfonated Poly(arylene ether sulfone) Composite Membrane for Direct Methanol Fuel Cell

  • Choi Jisu;Kim II Tae;Kim Sung Chul;Hong Young Taik
    • Macromolecular Research
    • /
    • 제13권6호
    • /
    • pp.514-520
    • /
    • 2005
  • Composite membranes of Nafion and sulfonated poly(arylene ether sulfone) were prepared. Sulfonated poly(arylene ether sulfone)s with different degrees of sulfonation were blended with Nafion to reduce the methanol crossover. The morphology, proton conductivity and methanol permeability of the resulting composite membranes were investigated by SEM, EDAX, AC impedance spectroscopy and permeability measuring instrument. The cross­sections of the composite membranes showed a phase separated morphology. The morphology and phase separation mechanism could be controlled by varying the blend ratio and the degree of sulfonation of poly(arylene ether sulfone). These complex morphologies can be applied for reducing methanol crossover. The methanol permeability and proton conductivity of the composite membranes were lower than those of Nafion 117 membrane since the development of an ionic pathway in the blend membrane was more difficult than that in Nafion itself.

차폐재의 재료특성에 따른 60Hz ELF 자계차폐 효과분석 (Investigation of shielding effects of 60Hz ELF magnetic fields on shielding material property)

  • 민석원;송기현;명성호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 하계학술대회 논문집 C
    • /
    • pp.1960-1962
    • /
    • 2004
  • In this paper, we have studied shielding characteristics of high conductivity or high permeability materials on ELF magnetic fields generated from single or three phase AC line. Perm alloy has been selected as high permeability material and copper as high conductivity material. Four-plate shield (square section) was considered as a shielding shape. We found copper showed stable shielding effects more than perm alloy.

  • PDF

폴리머 시멘트 콘크리트의 배합조건이 투수성능과 역학적 성질에 미치는 영향 (Effect of Mix Proportions on the Permeability and Mechanical Properties of Polymer Cement Concrete)

  • 박응모;조영국;소양섭
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1998년도 가을 학술발표논문집(II)
    • /
    • pp.356-361
    • /
    • 1998
  • Permeable polymer cement concrete in this study is one of the invironment conscious concretes that can be applied at roads, side walks, parking lots, interlocking block and river embankment, etc. In this study, permeable polymer cement concretes using polymer dispersion(St/Ac) with water-cement ratios of 25, 30, 35 and 40%, polymer-cement ratios of 0, 5, 10, 15 and 20%, and a ratio of cement to aggregate (by weight), 1 : 3.5(about 415kg/㎥), 1 : 4.0(about 375 kg/㎥), and 1 : 4.5(about 345kg/㎥) are prepared, and tested for compressive, flexural and tensile strength, and permeability. From the test results, increase in the strengths of permeable polymer cement concrete are clearly observed with increasing polymer-cement ratio, we can obtain the maximum strengths at water-cement ratio of 35%. The optimum permeable polymer cement concrete according to application and location of work can be selected in various mix proportions.

  • PDF

스테인레스 제강분진을 함유한 순철 압분코아의 자기특성 (Magnetic Properties of Powdered Fe Cores Containing Stainless Steel-making Dusts)

  • 김상원
    • 한국재료학회지
    • /
    • 제15권2호
    • /
    • pp.106-111
    • /
    • 2005
  • Effects of stainless steel-making dusts and binder content on compacting $density(\rho)$ and magnetic properties were evaluated. Cores compacted with the mixture of pure Fe powders, $5wt.\%$ dusts and $0.25wt.\%$ binder showed good AC magnetic properties. For example, permeability$({\mu}a)$ and core loss(P) of the cores containing $5wt.\%$ dusts at 500 kHz were 62 and $4008\;{\mu}W/cm^3$, respectively. These properties are almost equivalent to those of competitor's products (i.e, Ancorsteel TC 80 produced by $H\ddot{o}gan\ddot{a}s$ Corp.). The powdered cores obtained from the present work are expected to apply for high-performance soft magnetic components such as normal mode choke filter and pulse transformer.

예비성형체 및 금속복합재료에 미치는 바인더의 영향에 관한 연구 (Effects of Binder on the Mechanical Properties of Preform and MMCs)

  • 남현욱;민병렬;이종해;한경섭
    • 대한기계학회논문집A
    • /
    • 제23권6호
    • /
    • pp.952-960
    • /
    • 1999
  • The effects of binder on the mechanical properties of the preforms and metal matrix composites (MMCs) were studied. Fibers were $9Al_2O_3{\cdot}2B_2O_3(Alborex)$, HTZ and $Al_2O_3$ fibers(Saffil) and binders were organic binder, inorganic binder, polyacrylamide under various PH conditions. Compressive strength of the preform increased with the addition of inorganic binder. The polyacrylamide did not improve the permeability of the preforms. PH of the slurry should be controlled because it affects the viscosity of the slurry. Good preforms were obtained under following conditions : 3 wt% inorganic binder, 0.1 wt% organic binder, 0.1 wt% polyacrylamide and PH 9. Tensile tests of MMCs were conducted at $20^{\circ}C,\;150^{\circ}C,\;250^{\circ}C,\;350^{\circ}C$ using MTS(100KN USA). Wear tests were conducted under various sliding speeds. High temperature($250^{\circ}C$) tensile strengths of Alborex/Saffil/AC8A and HTZ/AC8A are 80% and 75% of the room temperature tensile strengths respectively. The tensile and wear properties of the Alborex/Saffil/AC8A are superior to that of the HTZ/AC8A. The wear behavior of HTZ/AC8A shows more orthotropic characteristic than that of Alborex/Saffil/AC8A.

교류 아크용접기를 사용하는 작업자의 이중 차폐복 자계저감 특성검토 (Magnetic Fields Reduction Characteristics of Multi-layer Shielding Wear for a Worker Using AC Arc Welder)

  • 민석원;박준형;이승호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2009년도 제40회 하계학술대회
    • /
    • pp.1465_1466
    • /
    • 2009
  • Power cable of an AC arc welder can surround a body of worker at the moment of welding. Applying the boundary element method, we calculated current densities induced in organs inside a worker in case he weared a multi-layer shielding cloth. We know these were lowest when high permeability materials such as silicon and permalloy were applied to the interior of a suit and high conductivity materials such as copper were to the exterior.

  • PDF

Biot 음향 전파 이론을 이용한 실내 사질 시료의 투수계수 산정 (Laboratory Evaluation of Soil Permeability for Sand Using Biot's Acoustic Wave Propagation Theory)

  • 김진원;송정락
    • 한국지반공학회논문집
    • /
    • 제24권8호
    • /
    • pp.5-12
    • /
    • 2008
  • Biot는 균질하며 등방성인 포화된 물질에서의 혼합체 연동이론(coupled theory mixtures)을 이용하여 탄성파 전파의 진동수 의존성에 관한 이론을 제시하였다. Biot의 이론에 의하면 포화된 지반을 전파하는 탄성파의 진동수는 지반의 투수계수에 관한 정보를 가지고 있음을 보여주고 있다. 지반의 투수계수 산정에 사용되는 특정 진동수는 '특성 진동수 (characteristic frequency)'라 불리며, 특성 진동수는 진동수의 연속변화를 통한 I/Q(inverse quality factor)와 진동수의 관계도에 의하여 구할 수 있으며, 지반의 투수계수는 Biot의 식을 이용하여 산정할 수 있다. 본 연구에서는 시험상자 (test box)를 이용한 실내 시험을 미시시피 주립대학에서 수행함으로써 특성 진동수를 측정하였으며, 또 이를 이용하여 투수계수를 계산하였다. 모르타르 모래 시료에 대하여 시험한 결과 특성 진동수는 3500Hz에서 나타났으며 이를 Biot 식을 이용하여 시료의 투수계수를 산정한 결과 투수계수는 2.01 $10^{-4}m/sec$로 나타났다. 이는 실내 정 수두 투수계수 시험 값인 1.49 $10^{-4}m/sec$ 와 비교했을 때 다소 크게 나타났다 그러나 이 차이는 투수계수의 통상적인 오차범위를 고려할 때 매우 합리적인 것으로 나타났다. 따라서, 본 연구는 음파를 이용하여 보다 쉽고 빠른게 지반의 투수계수를 산정할 수 있는 가능성이 있음을 보여 주었다. 본 논문에서는 특별히 고안된 장치를 통하여 시료의 특성 진동수를 실험적으로 결정하는 세부적인 방법과 그 이론적인 배경을 기술하였다.

가스분무법으로 제조한 MPP 분말코어의 자기적 특성에 미치는 열처리 효과 (The Effects of Heat-treatment on Magnetic Properties for Gas-atomized MPP Dust Cores)

  • 노태환;김구현;김광윤;정인범;최광보
    • 한국자기학회지
    • /
    • 제11권4호
    • /
    • pp.173-178
    • /
    • 2001
  • 가스분무법으로 만든 MPP 압분자심을 무자장 및 자장중에서 열처리한 후 냉각속도를 달리할 때 얻어지는 자기적 특성의 변화를 조사하였다. 무자장중에서 열처리시 냉각속도가 증가하면 교류투자율 및 자심손실이 감소하였으며, 이는 각각 빠른 냉각속도에서의 불균일한 내부음력의 발생과 이상 와전류손실의 감소에 기인하는 것으로 해석되었다. 한편 MPP 압분체를 무자장 열처리 후 냉각속도를 달리하여도 Ni-Fe 합금에서 전형적으로 나타나는 규칙상의 형성에 따른 자기적 특성의 변화는 보이지 않았으나, 느린 냉각속도의 조건하에서 자장열처리를 하면 용이하게 구성원자의 방향성 규칙화에 의해 유도자기이방성이 생성되며 상당한 투자율 및 자심손실의 변화가 얻어지는 것으로 관찰되었다.

  • PDF

Transport Properties of Polymer Blend Membranes of Sulfonated and Nonsulfonated Polysulfones for Direct Methanol Fuel Cell Application

  • Kim, Dong-Hwee;Kim, Sung-Chul
    • Macromolecular Research
    • /
    • 제16권5호
    • /
    • pp.457-466
    • /
    • 2008
  • The relation between the phase separated morphologies and their transport properties in the polymer blend membrane for direct methanol fuel cell application was studied. In order to enhance the proton conductivity and reduce the methanol crossover, sulfonated poly(arylene ether sulfone) copolymer, with a sulfonation of 60 mol% (sPAES-60), was blended with nonsulfonated poly(ether sulfone) copolymer (RH-2000, Solvay). Various morphologies were obtained by varying the drying condition and the concentration of the casting solution (10, 15, 20 wt%). The transport properties of proton and methanol molecule through the polymer blend membranes were studied according to the absorbed water. AC impedance spectroscopy was used to measure the proton conductivity and a liquid permeability measuring instrument was designed to measure the methanol permeability. The state of water in the blend membranes was confirmed by differential scanning calorimetry and was used to correlate the morphology of the membrane with the membrane transport properties.