• Title/Summary/Keyword: AC over-current

Search Result 120, Processing Time 0.031 seconds

절연층을 고려한 Bi-2223/Ag 선재의 교류 과전류 특성 (AC over-current characteristics of Bi-2223/Ag tape considering insulating layers)

  • 두호익;임성우;박충렬;최병환;한병성
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2007년도 하계학술대회 논문집 Vol.8
    • /
    • pp.249-250
    • /
    • 2007
  • Applying the AC over-currents over the critical current to Bi-2223/Ag tape having 56 A Ie, resistance increase with the duration of current application was measured and analyzed. In addition, the influence of the tape's electrical insulation on the over-current characteristics was investigated and compared with each other. From the results, we will establish the safe operating condition against the AC over-currents and the protection of the tape for the practical power application such as cable and transformer.

  • PDF

Corrosion Rate of Buried Pipeline by Alternating Current

  • Song, H.S.;Kim, Y.G.;Lee, S.M.;Kho, Y.T.;Park, Y.S.
    • Corrosion Science and Technology
    • /
    • 제4권1호
    • /
    • pp.1-7
    • /
    • 2005
  • An alternating current (AC) corrosion on buried pipeline has been studied using coupon and ER probe. Coupons and ER probes were applied to the sites from high value of AC voltage to low value based on the survey of AC voltages on buried gas transmission pipeline over the country. Parameters such as AC current density of coupon, AC voltage, cathodic protection potential, soil resistivity and frequency were monitored continually. Corrosion induced by AC was observed even under cathodically protected condition that met cathodic protection criterion (; below -850 mV vs. CSE). Corrosion rate was affected mainly not by AC voltage but by both of frequency and AC current density. An experimental corrosion rate relation could be obtained according to effective AC current density, in which AC corrosion rate increased linearly with effective AC current density, and its slope was 0.619 in coupon method and 0.885 in ER probes.

교류가 유도되는 매설배관에서의 교류 부식속도 측정에 관한 연구 (Corrosion Rate of Buried Pipeline by Induced Alternating Current)

  • 송홍석;김영근;이성민;고영태;박용수
    • 한국가스학회:학술대회논문집
    • /
    • 한국가스학회 2001년도 추계학술발표회 논문집
    • /
    • pp.45-57
    • /
    • 2001
  • An alternating current (AC) corrosion using coupon has been studied. Coupons were applied in terms of AC voltage from high value to low value through the survey of AC voltages on buried gas transmission pipeline over the country. Parameters such as AC current density of coupon, AC voltage, cathodic protection potential, soil resistivity and frequency were monitored continually. Corrosion induced by AC was observed even under cathodically protected condition that met cathodic protection criterion(: below -850mv vs. CSE). Corrosion rate was affected mainly not by AC voltage but by both of frequency and AC current density. An experimental corrosion rate relationship could be obtained statistically, in which AC corrosion rate increased linearly with effective AC current density and its slope was 0.619.

  • PDF

임펄스전류에 의한 배전용 ZnO 피뢰기 소자의 열화특성 (Deterioration Characteristics of ZnO Surge Arrester Blocks for Power Distribution Systems Due to Impulse Currents)

  • 이복희;조성철;양순만
    • 조명전기설비학회논문지
    • /
    • 제27권3호
    • /
    • pp.79-86
    • /
    • 2013
  • In order to analyze the electrical performance of ZnO surge arresters stressed by the combined DC and AC voltages that are generated in DC/AC converter systems, the leakage current properties of ZnO surge arrester blocks deteriorated by impulse currents were investigated. The test specimens were deteriorated by the 8/$20{\mu}s$ impulse current of 2.5kA and the leakage currents flowing into the deteriorated zinc oxide(ZnO) arrester blocks subjected to the combined DC and power frequency AC voltages are measured. As a result, the leakage currents flowing through deteriorated ZnO surge arrester blocks were higher than those flowing through the fine ZnO surge arrester blocks and the larger the injection number of 8/$20{\mu}s$ impulse current of 2.5kA is, the greater the leakage current is. The leakage current-voltage curves(I-V curves) of the fine and deteriorated ZnO surge arrester blocks stressed by the combined DC and AC voltages show significant difference in the low conduction region. Also the cross-over phenomenon is observed at the voltage close to the knee of conduction on plots of I-V curves.

고온초전도 선재의 과전류 통전 특성 (Over critical current characteristics of HTS tapes)

  • 임성우;황시돌;최용선;최효상;현옥배;유재무
    • 한국초전도저온공학회:학술대회논문집
    • /
    • 한국초전도저온공학회 2002년도 학술대회 논문집
    • /
    • pp.241-244
    • /
    • 2002
  • We investigated over critical current characteristics of HTS tapes fabricated by KIMM. The critical current (Ic) of the HTS tapes was 68A/cm. In order to acquire over current I-V characteristics of HTS tapes, we applied AC that is 2-7 times of Ic to these tapes. When applied AC whose peak value is twice of Ic, we found out that total resistance of HTS tapes aid not change. In case of 3 times of Ic, resistances of HTS tapes began to increase slowly. However, superconducting regions of them were maintained stably in this condition. In addition, 280 $A_{peak}$was applied, superconducting regions began to be decreased gradually. Finally, 0.62m$\Omega$ of resistance was measured in HTS tapes which was applied AC correspond to 7 times of Ic at first cycle.

  • PDF

영전류 스위칭 방식의 직렬 공진형 AC/DC 컨버터를 위한 전환모드 이산 슬라이딩 제어 (Switched discrete sliding mode control for ZCS series rosonant AC to DC converter)

  • 문건우;이정훈;이대식;윤명중
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1993년도 한국자동제어학술회의논문집(국내학술편); Seoul National University, Seoul; 20-22 Oct. 1993
    • /
    • pp.1219-1226
    • /
    • 1993
  • A buck-boost zero current switched(ZCS) series resonant AC to DC converter for the DC output voltage regulation together with high power factor is proposed. The proposed single phase AC to DC converter enables a zero current switching operation of all the power devices allowing the circuit to operate at high swtiching frequencies and high power levels. A dynamic model for this Ac to DC converter is developed and an analysis for the internal operational characteristics is explored. Based on this analysis, a switched discrete sliding mode control(SDSMC) technique is investigated and its advantages over the other types of current control techniques are discussed. With the proposed control technique, the unity power factor without a current overshoot and a wide range of output voltage can be obtained.

  • PDF

Electrical Behaviors of ZnO Elements under Combined Direct and Alternating Voltages

  • Yang, Soon-Man;Lee, Bok-Hee;Paek, Seung-Kwon
    • Journal of Electrical Engineering and Technology
    • /
    • 제4권1호
    • /
    • pp.111-117
    • /
    • 2009
  • This paper presents the characteristics of leakage currents flowing through zinc oxide (ZnO) surge arrester elements under the combined direct-current (DC) and 60 Hz alternating-current (AC) voltages. The current-voltage characteristic curves (I-V curves) of the commercial ZnO surge arrester elements were obtained as a function of the voltage ratio a. At constant peak value of the combined DC and AC voltage, the resistive leakage current of the ZnO blocks was significantly increased as the voltage ratio $\alpha$ increased. The I-V curves under the combined DC and AC voltages were placed between the pure DC and AC characteristics, and the cross-over phenomenon in both the I-V curves and R-V curves was observed at the low current region. The ZnO power dissipation for DC voltages was less than that for AC voltage in the pre-breakdown region and reversed at higher voltages.

고온초전도 선재의 과전류 통전 특성에 대한 피치의 영향 (Influence of pitch on over-current characteristics of HTS tapes)

  • 임성우;황시돌;최효상;김헤림;한병성
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2002년도 하계학술대회 논문집
    • /
    • pp.507-510
    • /
    • 2002
  • In economical points of view, AC loss of high temperature superconducting devices is considered as a serious problem that must be solved. Expecially, in case of HTS cables, HTS tapes are wound helically on the former to reduce AC loss. Critical characteristics of HTS tapes, however, are influenced by mechanical stress as well as electrical, temperature, and magnetical factors. The purpose of this study is to investigate the over current characteristics of HTS tapes given mechanical stress when they are wound on the former. We prepared HTS tapes with the pitch angle 20$^{\circ}$, length 25cm as well as tapes with pitch angle 0$^{\circ}$. When current of over 200A$\_$rms/ was applied, we found out that there are differences to the rate of resistance increase between the case of pitch angle 20$^{\circ}$and that of 0$^{\circ}$. The rate of resistance variation in HTS tapes of pitch angle 20$^{\circ}$increased more slowly than that of pitch angle 0$^{\circ}$. As a result, we concluded that if critical characteristics of HTS tapes are degraded by any external factor, when over current is applied, the current limiting characteristics in HTS tapes won't be able to be expected any more.

  • PDF

과전류에 의한 동 전선의 용단 아크 특성 및 금속조직 분석 (The Analysis of Metallurgical Structure and Arc Properties of Copper Wire Due to Over-current)

  • 김영석;송길목;김동욱;이기연;최충석
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2005년도 하계학술대회 논문집 Vol.6
    • /
    • pp.554-555
    • /
    • 2005
  • In this paper, we analyzed a metallurgical structure and arc properties of copper wire when the over-current flows on electric wire. From the results, The fusing current was related to the fusing time(current rising rate per second). In case of the shorter the fusing time, the fusing current was high, and the fusing time of ac type was larger than that of dc type. The copper wire was bent by the increase of current and heated, the beads were scattered around wire with a flash. We could observed the dendrite structure in 'molten wire at ac and dc current type. According as the current rising rate per second is short, the dendrite structure is distributed in surface of wire.

  • PDF

교류가 유도되는 매설배관에서의 교류 부식속도 측정에 관한 연구 (Corrosion Rate of Buried Pipeline by Induced Alternating Current)

  • 송홍석;김영근;이성민;고영태;박용수
    • 한국가스학회지
    • /
    • 제5권3호
    • /
    • pp.63-72
    • /
    • 2001
  • 천연가스 공급용 고압 지하 매설배관에 교류가 유도될 때 쿠폰과 전기저항형 박막센서를 이용하여 교류에 의한 부식속도를 평가하고 주요한 인자를 규명하고자 하였다. 전국에 걸쳐 조사된 교류전압 측정결과를 바탕으로 쿠폰과 전기저항형 박막센서를 설치하고, 주요인자를 고찰하기 위하여 다양한 인자들 (교류전압, 교류전류, 토양 비저항, 주파수, 방식전위)을 정기적으로 기록하였다. 황산동 전극기준 -850mV의 방식전위를 충분히 만족하는 상황에서도 교류에 의한 부식이 진행하였으며, 교류에 의한 부식속도는 교류전압과는 관계없이 교류전류밀도와 주파수에 의존하는 것으로 나타났다. 교류에 의한 부식속도는 유효교류전류밀도에 따라 직선적으로 증가하였으며, 쿠폰에 의한 평가결과 직선의 기울기는 0.619, 전기저항형 센서에 의한 직선의 기울기는 0.885로 나타났다.

  • PDF