• Title/Summary/Keyword: AC magnetic field

Search Result 213, Processing Time 0.017 seconds

Cerebrocortical Regions Associated with Implicit and Explicit Memory Retrieval Under the Conceptual Processing: BOLD Functional MR Imaging

  • Kim, Hyung-Joong;Kang, Hyung-Geun;Seo, Jung-Jin;Jung, Kwang-Woo;Eun, Sung-Jong;Park, Jin-Kyun;Yoon, Woong;Park, Tae-Jin
    • Proceedings of the KSMRM Conference
    • /
    • 2002.11a
    • /
    • pp.111-111
    • /
    • 2002
  • Purpose: This study is to compare the distinct brain activation between implicit and explicit memory retrieval tasks using a non-invasive blood-oxygenation-level-dependent (BOLD) functional magnetic resonance imaging(fMRI). Materials & Methods: We studied seven right-handed, healthy volunteers aged 21-25 years(mean;22 years) were scanned under a 1.5T Signa Horizon Echospeed MR imager(GE Medical Systems, Milwaukee, U.S.A.). During the implicit and explicit memory retrieval tasks of previously teamed words under the conceptual processing, we acquired fMRI data using gradient-echo EPI with 50ms TE, 3000ms TR, 26cm${\times}$26cm field-of-view, 128${\times}$128 matrix, and ten slices(6mm slice thickness, 1 mm gap) parallel to the AC-PC(anterior commissure and posterior commissure) line. By using the program of statistical parametric mapping(SPM99), functional activation maps were reconstructed and quantified.

  • PDF

Construction and Performance of Magnetically Shielded Room for Biomagnetic Applications (생체자기계측을 위한 자기차폐실의 설치 및 특성)

  • 이용호;권혁찬;김진목;임청무;이상길;박용기;박종철
    • Journal of the Korean Magnetics Society
    • /
    • v.6 no.4
    • /
    • pp.264-271
    • /
    • 1996
  • A magnetically shielded room has been constructed for biomagnetic applications. The room has internal dimensions of $2\;m(length){\times}2\;m(width){\times}2.5\;m(height)$ and it consists of high permeability Mumetal and high conductivity alummum, utilizing ferromagnetic shielding and eddy current shielding. The de shielding factor around the center of the room is above 60 dB, and the ac shielding factors at 1 and 10 Hz are larger than 60 and 80 dB, respectively. The internal magnetic field noise at 1 Hz is $500\;fT/{\sqrt}Hz$ and at 10 Hz is $100\;fT/{\sqrt}Hz$, and the field gradient noise at 1 Hz is below $7\;fT/cm{\sqrt}Hz$. Successful measurements of cardiomagnetic fields usmg SQUID magnetometer and neuromagnetic fields using SQUID gradiometer have been done.

  • PDF

Magnetic Properties of Superparamagnetic Ni-Zn Ferrite for Nano·Bio Fusion Applications (나노·바이오 융합응용을 위한 초상자성 Ni-Zn Ferrite의 자기적 특성연구)

  • Lee, Seung-Wha;Ryu, Yeon-Guk;Yang, Kea-Joon;An, Jung-Su;Kim, Chul-Sung
    • Journal of the Korean Magnetics Society
    • /
    • v.15 no.2
    • /
    • pp.100-105
    • /
    • 2005
  • $Ni_{0.9}Zn_{0.1}Fe_2O_4$ nanoparticles have been prepared by a sol-gel method. The structural and magnetic properties have been investigated by DTA/TGA, XRD, SEM, and $M\ddot{o}ssbauer$ spectroscopy, VSM. $Ni_{0.9}Zn_{0.1}Fe_2O_4$ powder that was annealed at $300^{\circ}C$ has spinel structure and behaved superparamagnetically. The estimated size of superparammagnetic Ni-Zn ferrite nanoparticle is around 10 nm. The hyperfine fields at 13 K for the A and B patterns were found to be 533 and 507 kOe, respectively. The blocking temperature ($T_B$) of superparammagnetic $Ni_{0.9}Zn_{0.1}Fe_2O_4$ nanoparticle is about 250 K. The magnetic anisotropy constant and relaxation time constant of $Ni_{0.9}Zn_{0.1}Fe_2O_4$ nanoparticle were calculated to be $1.6\times10^6\;ergs/cm^3$ and ${\tau}_0=5.0{\times}10^{-13}$ s, respectively. Also, Temperature increased up to $43^{\circ}C$ within 10 minutes under AC magnetic field of 7 MHz. It is considered that $Ni_{0.9}Zn_{0.1}Fe_2O_4$ powder that was annealed at $300^{\circ}C$ is available for biomedicine application such as hyperthermia, drug delivery system and contrast agents in MRI.