• Title/Summary/Keyword: AC current

Search Result 2,316, Processing Time 0.027 seconds

Deterioration Characteristics of ZnO Surge Arrester Blocks for Power Distribution Systems Due to Impulse Currents (임펄스전류에 의한 배전용 ZnO 피뢰기 소자의 열화특성)

  • Lee, Bok-Hee;Cho, Sung-Chul;Yang, Soon-Man
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.27 no.3
    • /
    • pp.79-86
    • /
    • 2013
  • In order to analyze the electrical performance of ZnO surge arresters stressed by the combined DC and AC voltages that are generated in DC/AC converter systems, the leakage current properties of ZnO surge arrester blocks deteriorated by impulse currents were investigated. The test specimens were deteriorated by the 8/$20{\mu}s$ impulse current of 2.5kA and the leakage currents flowing into the deteriorated zinc oxide(ZnO) arrester blocks subjected to the combined DC and power frequency AC voltages are measured. As a result, the leakage currents flowing through deteriorated ZnO surge arrester blocks were higher than those flowing through the fine ZnO surge arrester blocks and the larger the injection number of 8/$20{\mu}s$ impulse current of 2.5kA is, the greater the leakage current is. The leakage current-voltage curves(I-V curves) of the fine and deteriorated ZnO surge arrester blocks stressed by the combined DC and AC voltages show significant difference in the low conduction region. Also the cross-over phenomenon is observed at the voltage close to the knee of conduction on plots of I-V curves.

Three Phase PWM AC/DC Converter with Leading Current Compensation Control (AC Filter Capacitor 에 따른 진상 전류 보상 회로를 갖는 $3{\phi}$ PWM AC/DC 컨버터)

  • Kim, E.S.;Joe, K.Y.;Suh, K.Y.;Lee, H.W.;Kwon, S.K.
    • Proceedings of the KIEE Conference
    • /
    • 1995.07a
    • /
    • pp.268-270
    • /
    • 1995
  • This paper proposes a novel PWM technique for a three phase current fad type converters. A minor loop compensation method is introduced to compensate leading current and to minimize input line current (Iu) distortion resulting from the resonance between AC filter capacitor and source inductance of power system. This PWM converter has excellent characterics as next. The control system is simply designed, and the operation with unity power factor can be easily obtained by automatic compensating the leading current of the filter circuit. Also. the three phase sinusoidal input current can be obtained.

  • PDF

Switched discrete sliding mode control for ZCS series rosonant AC to DC converter (영전류 스위칭 방식의 직렬 공진형 AC/DC 컨버터를 위한 전환모드 이산 슬라이딩 제어)

  • 문건우;이정훈;이대식;윤명중
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1993.10a
    • /
    • pp.1219-1226
    • /
    • 1993
  • A buck-boost zero current switched(ZCS) series resonant AC to DC converter for the DC output voltage regulation together with high power factor is proposed. The proposed single phase AC to DC converter enables a zero current switching operation of all the power devices allowing the circuit to operate at high swtiching frequencies and high power levels. A dynamic model for this Ac to DC converter is developed and an analysis for the internal operational characteristics is explored. Based on this analysis, a switched discrete sliding mode control(SDSMC) technique is investigated and its advantages over the other types of current control techniques are discussed. With the proposed control technique, the unity power factor without a current overshoot and a wide range of output voltage can be obtained.

  • PDF

Optimum AC losses Determination for Duty Cycle of Superconductive Magnetic Energy Storage (초전도에너지 저장장치의 운전주기에 따른 최적교류손실 결정에 관한 연구)

  • Hwang, Seuk-Yong
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.39 no.7
    • /
    • pp.653-667
    • /
    • 1990
  • Superconductor is consolidated, for required current capacity, with proper numbers of basic strands which are multifilamentary composites. Althouth superconductors are perfectly loss-free under DC conditions of current and field, AC losses occur under time-varying condition of the current and field. The AC losses are a controllable inherent characteristics of supercondectors. The AC losses dependent on the changing rate of current and field can be reduced by reducing the filament diameter. On the other hand, finer filament results in manufacturing cost increase. Therefore, in this paper optimization technique of superconductor for SMES is proposed from the viewpoint of AC loss reduction and manufacturing cost increase. The case study shows that the technique can be effectively used for the design of superconductor for SMES, appreciating the influence of various parameters related to superconductor itself and operating condition of SMES. As a result of the case study, it is confirmed that the technique is more effective for the design of superconductor for SMES for electric power power system stabilization rather then SMES for energy storage.

  • PDF

A Study on PFC AC-DC Converter of High Efficiency added in Electric Isolation (절연형 고효율 PFC AC-DC 컨버터에 관한 연구)

  • Kwak, Dong-Kurl;Kim, Sang-Roan
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.7
    • /
    • pp.1349-1355
    • /
    • 2009
  • This paper is studied on a novel power factor correction (PFC) AC-DC converter of high efficiency by soft switching technique. The input current waveform in the proposed converter is got to be a sinusoidal form composed of many a discontinuous pulse in proportion to the magnitude of a ac input voltage under the constant switching frequency. Therefore, the input power factor is nearly unity and the control method is simple. The proposed converter adding an electric isolation operates with a discontinuous current mode (DCM) of the reactor in order to obtain some merits of simpler control, such as fixed switching frequency, without synchronization control circuit used in continuous current mode (CCM). To achieve the soft switching (ZCS or ZVS) of control devices, the converter is constructed with a new loss-less snubber for a partial resonant circuit. It is that the switching losses are very low and the efficiency of the converter is high, Particularly, the stored energy in a loss-less snubber capacitor recovers into input side and increases input current from a resonant operation. The result is that the input power factor of the proposed converter is higher than that of a conventional PFC converter. This paper deals mainly with the circuit operations, theoretical, simulated and experimental results of the proposed PFC AC-DC converter in comparison with a conventional PFC AC-DC converter.

AC loss Characteristics under Critical Current Degradation of HTS Tapes (고온 초전도 tape의 임계전류 저하에 따른 교류손실 특성)

  • Kim H. J.;Cho J. W.;Kim J. H.;Sim K. D.;Kwag D. S.;Bae J. H.;Kim H. J.;Seong K. S.
    • Progress in Superconductivity and Cryogenics
    • /
    • v.7 no.3
    • /
    • pp.29-33
    • /
    • 2005
  • Critical current$(I_c)$ degradation of High $T_c$ Superconducting(HTS) tapes and AC loss under mechanical load is one of the hottest issues in HTS development and application. Mechanical load reduces the critical current of superconducting wire, and the $I_c$ degradation affects the AC loss of the wire. We measured the $I_c$ degradation and AC loss under tension and bending of Bi-2223 tapes made by 'Powder-in-Tube' technique at 77K with self-field. Also, we have studied the frequency characteristics on self-field AC loss in multi-filamentary Bi-2223/Ag tape at 77K. The measurement results and discussions on the relationship between $I_c$ degradation and AC loss are presented.

Ac Loss Characteristics under Critical Current Degradation of HTS Tapes (고온 초전도체의 임계전류 저하에 따른 교류 손실 특성)

  • Kim, Hae-Joon;Kim, Jae-Ho;Sim, Ki-Deok;Cho, Jeon-Wook;Kwag, Dong-Soon;Kim, Hae-Jong;Seong, Ki-Chul
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2005.07a
    • /
    • pp.286-287
    • /
    • 2005
  • Critical current(Ic) degradation of HTS tapes and AC loss under mechanical load is one of the hottest issues in HTS development and application. Mechanical load reduces the critical current of superconducting wire, and the Ie degradation affects the AC loss of the wire. We measured the Ie degradation and AC loss under tension and bending of Bi-2223 tapes processed by "Powder-in-Tube" technique at 17K with self-field. And we have studied the frequency dependence of self-field AC loss in multi-filamentary Bi-2223/Ag tape at 77K. The measurement results and discussions on the relationship between Ic degradation and AC loss are presented.

  • PDF

Analysis of AC losses in HTS coils by temperature variations

  • Kim, Yungil;Lee, Ji-Kwang;Lee, Seyeon;Kim, Woo-Seok;Lee, Siyoung;Choi, Kyeongdal
    • Progress in Superconductivity and Cryogenics
    • /
    • v.20 no.4
    • /
    • pp.50-54
    • /
    • 2018
  • We analyzed the temperature dependency of the AC losses in high temperature superconducting (HTS) coils. In the case of a short sample of an HTS tape, the magnetization loss at 4.2 K could be higher than the one at 77 K for a same transport current. It happens when the perpendicular magnetic field is above a certain magnitude. The AC loss characteristics of solenoidal coils have been analyzed at the temperatures of 65 K and 77 K. They were categorized by the aspect ratios. The operating current of a solenoid was normally set about 70 % of the critical current. An HTS solenoid with the same operating current of 77 K causes larger AC losses at 65 K in the most cases of the HTS solenoids. We also analyzed the AC loss characteristics due to the temperature variations for three types of superconducting magnetic energy storages. Two of them were solenoidal types and the other was toroidal type. The results showed the tendency for the coils to have higher AC losses at lower temperature with the same operating currents and scenarios.

Measurement and Numerical Analysis of AC Loss in the HTS Pancake Coil and the HTS Solenid Coil (고온초전도 팬케이크 코일과 솔레노이드 코일의 교류손실 측정 및 수치해석)

  • Park Myung-Jin;Lee Sang-Soo;Lee Seung-Wook;Cha Guee-Soo;Lee Ji-Kwang
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.53 no.12
    • /
    • pp.732-738
    • /
    • 2004
  • In this paper, we constructed 13 turns pancake coil and solenoid coil with HTS tape and measured AC losses of the pancake coil. The critical current of the pancake coil and the solenoid coil were 80A and 109A, respectively. To compare measured AC losses of the two coils, we carried out numerical analysis using 2-D FEM program for manufactured coils. This paper presents current density distribution, flux density distribution and AC losses of the pancake coil and the solenoid. As a result, we obtained that current density distribution was closely related to the orientation of magnetic field and distribution of AC losses were also closely related to the perpendicular component of flux density distribution in coil. The calculated AC losses of the two coils showed good agreement with measured AC losses and AC losses of the pancake coil was about 9 times bigger than that of the solenoid coil under the same turns and length.

Single Phase Multi-Level AC-DC Converter (단상 Multi-Level AC-DC 컨버터)

  • 안일매;전중함;이영호;박성우;서기영;이현우
    • Proceedings of the KIPE Conference
    • /
    • 1999.07a
    • /
    • pp.354-357
    • /
    • 1999
  • This paper is proposed Single phase Multi-Level AC-DC Converter. This is consist of diode bridge and switches. The number of the supply current levels depends on the number of the individual converter's current level. In this converter circuit the number of the levels is equal to 2(M+1) -1, where M is the number of Switching-Leg's number. In this paper is introduced converter with 31 current Level. If the number of current level is increased, smoother sinusoidal waveform can be obtained. The feasibility of the circuit is verified by computer simulation using PSIM

  • PDF