• Title/Summary/Keyword: AC Power Source

Search Result 524, Processing Time 0.024 seconds

Characteristic PCS of Inverter by Boost Converter of PV Generation (태양광 발전 부스트 컨버터를 이용한 인버터 PCS 특성)

  • Hwang, Lark-Hoon;Na, Seung-kwon;Oh, Sang-hak
    • Journal of Advanced Navigation Technology
    • /
    • v.22 no.6
    • /
    • pp.654-664
    • /
    • 2018
  • In this paper, this system is operated by PCS that is driven by being synchronized voltage fed inverter and AC source, and in the steady state of power source charge battery connected to DC side with solar cell using a photovoltaic (PV) that it was so called constant voltage charge. it can cause the effect of energy saving of electric power, from 10 to 20%. and through a normal operation of electric energy storage system (EESS). In addition, better output waveform was generated because of pulse width modulation (PWM) method, and it was Proved to test by experiment maintained constant output voltage regardless of AC source disconnection, load variation, and voltage variation of AC power source.

Design of High Efficiency Power Amplifier for Parametric Array Transducer using Variable Output Voltage AC/DC Converter (가변출력전압 AC/DC 컨버터를 이용한 파라메트릭 어레이 트랜스듀서용 고효율 전력증폭기의 설계)

  • Shim, Jae-Hyeok;Lee, Chang-Yeol;Kim, Seul-Gi;Kim, In-Dong;Moon, Won-Kyu;Lee, Jong-Hyeon;Kim, Won-Ho
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.19 no.4
    • /
    • pp.364-375
    • /
    • 2014
  • Parametric array transducers are used for long-range and highly directional communication in an underwater environments. The power amplifiers for parametric array transducers should have sufficient linear output characteristic and high efficiency to avoid communication errors, system heating, and fuel problems. But the conventional power amplifier with fixed source voltage is very low efficient due to large power loss by the big difference between the fixed source voltage and the amplifier output voltage. Thus to solve the problems this paper proposes the high efficiency power amplifier for parametric array transducers. The proposed power amplifier ensures high linearity of output characteristic by utilizing the push-pull class B type amplifier and furthermore gets high efficiency by applying the envelope tracking technique that variable source voltage tracks the envelope of the amplified signal. Also the paper suggests the detailed circuit topology and design guideline of class B push-pull type amplifier and variable output voltage AC/DC converter. Its characteristics are verified by the detailed simulation and experimental results.

Low Voltage Current Controlled Driving Method for AC PDP

  • Lee, Yang-Keun;Um, Jong-Sik;Kim, Joon-Yub
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2002.08a
    • /
    • pp.207-210
    • /
    • 2002
  • This paper presents a new driving method that can drive AC PDPs with low voltage and controlled-current for the sustaining period. The discharge current flowing into the AC PDP is limited in this method. Thus, the power consumption for the discharge is reduced and the discharge input power to output luminance efficiency is improved. Experimental results using this driving method showed that we could drive an AC PDP with a voltage source as low as 146 V and that luminous efficiency of 1.33 lm/W can be achieved.

  • PDF

A Study on Battery Charger Reliability Improvement of Nuclear Power Plants DC Distribution System (원자력발전소 직류 전력계통의 충전기 신뢰도 향상방안 연구)

  • Lim, Hyuk-Soon;Kim, Doo-Hyun
    • Journal of the Korean Society of Safety
    • /
    • v.25 no.2
    • /
    • pp.24-28
    • /
    • 2010
  • The nuclear power Plant onsite AC electrical power sources are required to supply power to the engineering safety facility buses if the offsite power source is lost. Typically, Diesel Generators are used as the onsite power source. The 125 VAC buses are part of the onsite Class 1E AC and DC electrical power distribution system. The DC power distribution system ensure the availability of DC electrical power for system required to shutdown the reactor and maintain it in a safety condition after an anticipated operational occurrence or a postulated Design Base Accident. Recently, onsite DC power supply system trip occurs the loss of system function. To obtain the performance such as reliability and availability, we analyzed the cause of battery charger trip and described the improvement of DC power supply system reliability. Finally, we provide reliability performance criteria of charger in order to ensure the probabilistic goals for the safety of the nuclear power plants.

A Single-Phase Quasi Z-Source Dynamic Voltage Restorer(DVR) (단상 Quasi Z-소스 동적전압보상기(DVR))

  • Lee, Ki-Taeg;Jung, Young-Gook;Lim, Young-Cheol
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.15 no.4
    • /
    • pp.327-334
    • /
    • 2010
  • This paper deals with a single-phase dynamic voltage restorer(DVR) with a quasi Z-source topology. The proposed system based on a single-phase quasi Z-source PWM ac-ac converter which have features such as the input voltage and output voltage are sharing ground, and input current operates in continuous current mode(CCM). For the detection of voltage sag-swell, peak voltage detection method is applied. Also, the circuit principles of the proposed system are described. During the 60% severe voltage sag and 30% voltage swell, the proposed system controls the adding or missing voltage and maintains the rated voltage of sinusoidal waveform at the terminals of the critical loads. Finally, PSIM simulation and experimental results are presented to verify the proposed concept and theoretical analysis.

Voltage Control Strategy of new 3-phase Line-Interactive UPS System using AC Line Reactor and Parallel-Serise Active Filter (AC 라인 리액터와 병렬 및 직렬 능동필터를 가지는 새로운 3상 Line-Interactive UPS 시스템의 전압제어 방식)

  • Ji, Jun-Keun
    • Proceedings of the KIPE Conference
    • /
    • 2005.07a
    • /
    • pp.201-203
    • /
    • 2005
  • A new 3-phase line-interactive UPS(Uninterruptible Power Supply) system with parallel-series active power-line conditioning capability using AC line reactor and two four-leg PWM VSCs(Voltage Source Converters) was introduced recently, In this paper, the strategy of voltage control in suggested UPS system is explained. The objective of proposed voltage controllers in parallel(shunt) and series PWM VSC is to guarantee satisfactory characteristics in steady state and transient state.

  • PDF

A study of residential solar airconditioning system using bidirectional PWM converter (양방향성 PWM컨버터를 이용한 가정용 태양광 에어컨 시스템에 관한 연구)

  • 유권종;송진수;황인호;김홍성;고재석;최규하;김한성
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.45 no.3
    • /
    • pp.358-364
    • /
    • 1996
  • Recently, much power demand from domestic power consumer is weakening the allowable power reserve margin in summer, especially at midday for one day due to a steep increase of air cooling loads such as air conditioner. Therefore solar airconditioning system can'be considered as one of the best remedies to meet the increase of peak power. Generally in solar air conditioning system, the diode rectifier is used to build up DC link voltage from AC source. The diode rectifier is simple and cheap but it brings out the problems of low power factor and plentiful harmonics at the AC source. Also It can derate the utilization rate of solar energy because the reverse of power flow cannot be made. Hence, in this paper to overcome the peak power problem in summer and to endure good AC input characteristics, solar air conditioning system using the PWM converter is proposed. As results, obtained are the characteristics of the PWM converter such as low distorted current waveform, high power factor and bidirectional power control. And also the stability of proposed system is verified by examining the dynamics of step load change and power reversal testing. (author). refs., figs., tabs.

  • PDF

The Control of Single Phase Power Factor PWM converter using Reduced-Order Luenberger Observer (축소차원 Luenberger 관측기를 이용한 단산 PWM 컨버터의 고역률 제어)

  • 양이우;이용근;김영석
    • Proceedings of the KIPE Conference
    • /
    • 1999.07a
    • /
    • pp.485-488
    • /
    • 1999
  • In this paper, a current control system for single phase PWM AC/DC converter without the source voltage sensors is proposed. The sinusoidal input current and unity effective power factor are realised based on the estimated source voltage in the controller. The estimation of source voltage is performed by the reduced-order Luenberger observer using actual currents. The estimated source voltage is used to accomplish unity power factor. The proposed method is proved by experiments.

  • PDF

The Control of Single Phase High Power Factor PWM converter using Reduced-order Luenberger Observer (축소차원 Luenberger 관측기를 이용한 단상 PWM 컨버터의 고역율 제어)

  • 양이우;유지용;김영석
    • Proceedings of the KIPE Conference
    • /
    • 1998.11a
    • /
    • pp.78-82
    • /
    • 1998
  • In this paper, the authors propose a current control system of single phase PWM AC/DC converter without the source voltage sensors. The sinusoidal input current and unity effective power factor are realised based on the estimated source voltage in the controller. The estimations of source voltage are performed based on the reduced-order Luenberger observer using actual currents. The estimated source voltage is used to accomplish unity power factor. The proposed method is proved by simulations

  • PDF

Applications of Current Limiting Diode to Chip on Board Type Light Source and Lighting Equipment Circuits (정전류다이오드를 이용한 COB 타입 LED 광원 및 조명기기 회로)

  • Park, Hwa Jin;Yu, S.J.;Park, Jong Min;Kim, Y.J.
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.26 no.6
    • /
    • pp.488-492
    • /
    • 2013
  • Current limiting diode (CLD) was fabricated using junction field effect transistor (JFET) structured two small cells and eight large cells. Two small cells and eight large cells were connected in parallel and the obtained constant current was 110 mA. The application of CLD in each of the parallel circuits on chip on board (COB) type LED lighting source, could significantly reduce the current deviation within the parallel circuits. The applications of CLD on AC power small lighting source, battery power low voltage parallel lighting source and AC flat lighting source were investigated.