• Title/Summary/Keyword: AC/A

Search Result 6,730, Processing Time 0.036 seconds

AC/DC Resonant Piezo-Powered Boost Converter for Piezoelectric Energy Harvesting (압전에너지 수확을 위한 AC/DC 공진형 자려 부스트 컨버터)

  • Kim, Hyeok-Jin;Chung, Gyo-Bum
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.14 no.6
    • /
    • pp.488-495
    • /
    • 2009
  • This paper proposes a new AC/DC RPPB(Resonant Piezo-Powered Boost) converter for energy harvesting using a piezoelectric device which converts mechanical vibration energy to electrical energy. The AC/DC RPPB converter can operate with only the harvested energy without an additional power conversion circuit for switching circuit and transfer energy to a load of which the voltage is higher than piezoelectric voltage. With the review of published topologies of the converter for energy harvesting, the operation principle of the AC/DC RPPB converter, and the results of PSPICE simulation and experiment are presented to prove the feasibility of the new converter for the energy harvesting.

Involvement of Board Chairmen in Audit Committees and Earnings Management: Evidence from Malaysia

  • AL-ABSY, Mujeeb Saif Mohsen;ISMAIL, Ku Nor Izah Ku;CHANDREN, Sitraselvi;AL-DUBAI, Shehabaddin Abdullah A.
    • The Journal of Asian Finance, Economics and Business
    • /
    • v.7 no.8
    • /
    • pp.233-246
    • /
    • 2020
  • This paper investigates the effect of the involvement of the board chairman in the audit committee (AC) on earnings management (EM). It examines Bursa Malaysia-listed companies with the lowest positive earnings for the years 2013 to 2015. The Modified Jones Model by Kasznik (1999) was used to determine discretionary accruals. An AC that includes its board chairman as an ordinary member is associated with greater discretionary accruals. However, a board chairman who is also the chairman of the AC does not seem to influence discretionary accruals. This paper supports the agency theory and policy-makers' efforts to prevent board chairmen from sitting on ACs. It is the first study that uses the agency theory to describe the association between the board chairman's involvement in the both AC and EM. This study alerts policy-makers, stakeholders and researchers to the influence of a board chairman serving on the AC in curbing EM. Furthermore, it provides empirical evidence that the majority of Malaysian companies whose board chairmen are involved in the AC appoint the chairman as an ordinary member of the AC. This indicates that executive directors may affect such actions. Hence, more policies are needed to improve AC independence.

Comparison of Binocular Function and Surgical Outcomes of Tenacious Proximal Fusion and High Accommodative Convergence/Accommodation Ratio Types of Intermittent Exotropia

  • Park, Jun Woo;Lee, Soo Jung
    • Korean Journal of Ophthalmology
    • /
    • v.32 no.6
    • /
    • pp.483-487
    • /
    • 2018
  • Purpose: To compare the characteristics and surgical outcomes in patients with tenacious proximal fusion (TPF) and high accommodative convergence/accommodation ratio (AC/A) types of intermittent exotropia. Methods: This study retrospectively enrolled 40 patients with intermittent exotropia, 23 with TPF and 17 with high AC/A. Binocular function was evaluated by Worth's 4-dot test. Patients underwent lateral rectus recession, and surgical outcomes were compared. Surgical success was defined as less than ${\pm}10$ prism diopters (PD) at 12 months postoperatively. Results: The proportion of diplopia at near, evaluated by Worth's 4-dot test, was significantly higher in patients with high AC/A than in those with TPF (35.3% vs. 4.3%, p = 0.029). The mean preoperative angles of deviation in TPF and high AC/A types were $28.3{\pm}4.4$ and $28.8{\pm}4.5PD$ at distances, and $14.7{\pm}4.2$ and $15.1{\pm}4.1PD$ at near. Twelve months after surgery, the mean angles of deviation in TPF and high AC/A types were $2.9{\pm}9.8$ and $1.2{\pm}9.6PD$, respectively, at distance and $1.7{\pm}7.7$ and $-1.3{\pm}11.3PD$ at near. The surgical success rates were similar in the TPF and high AC/A types (74.0% vs. 64.7%). Five (21.7%) patients with TPF and 2 (11.8%) with high AC/A type experienced recurrence, with consecutive esotropia occurring in 1 (4.3%) patient with TPF and 4 (23.5%) patients with high AC/A. Conclusions: The proportion of diplopia at near was higher in patients with high AC/A type than in those with TPF intermittent exotropia. However, the surgical success rates were not significantly different between the types.

A Study on the Enhanced Time Domain Aliasing Cancellation Transform of the AC-3 Algorithm (AC-3오디오 알고리듬의 시간축 영역 에일리어징 제거 변환부 성능향상에 관한 연구)

  • 김준성;강현철;변윤식
    • The Journal of the Acoustical Society of Korea
    • /
    • v.19 no.2
    • /
    • pp.13-18
    • /
    • 2000
  • This paper presents the result of a technique to enhance TDAC in the AC-3 algorithm. To reduce block boundary noise without decreasing the performance of transform coding, We propose new special windows which improve the defect of the AC-3 algorithm that could not properly cancel aliasing in the transient period. In addition, a fast MDCT calculation algorithm based on a fast Fourier transform, is adopted.

  • PDF

Electromagnetic Analysis of a Shading Ring Type AC Solenoid (쉐이딩 링 타입 교류 솔레노이드의 전자기적 해석)

  • Yang, Hyong-Yeol
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.58 no.2
    • /
    • pp.158-163
    • /
    • 2009
  • A shading ring in an AC solenoid plays an important role in reducing vibration and humming sound. Estimation of performance of the shading ring placed in a stator pole of the AC solenoid is not an easy task due to the difficulty in measurement of the current and flux linkage of the shading ring. In this paper, dynamic performance of an AC solenoid with a shading ring is analyzed through the simulation using electromagnetic analysis software and the results are verified by simple AC and DC voltage tests. Both the simulation and experimental results show that the shading ring in the AC solenoid not only increases pull force, but also reduces operation time, vibration and humming sound.

Proposed Distribution Voltage Control Method for Connected Cluster PV Systems

  • Lee, Kyung-Soo;Yamaguchi, Kenichiro;Kurokawa, Kosuke
    • Journal of Power Electronics
    • /
    • v.7 no.4
    • /
    • pp.286-293
    • /
    • 2007
  • This paper proposes a distribution voltage control method when a voltage increase condition occurs due to reverse power flow from the clustered photovoltaic (PV) system. This proposed distribution voltage control is performed a by distribution-unified power flow controller (D-UPFC). D-UPFC consists of a hi-directional ac-ac converter and transformer. It does not use any energy storage component or rectifier circuit, but it directly converts ac to ac. The distribution model and D-UPFC voltage control using the ATP-EMTP program were simulated and the results show the voltage increase control in the distribution system.

Traceable AC Voltage and Current Measurements Using Digital Sampling Technique (디지털 샘플링 방법을 사용한 교류전압과 전류의)

  • Wijesinghe, W.M.S.;Park, Young-Tae
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.686_687
    • /
    • 2009
  • The traceability maintenance system for the AC voltage and current has been developed at the frequency range of 20 Hz to 100 Hz without using any compensation technique which is used at thermal converter (TC) ac-dc transfer system at low frequencies. The system uses a digital voltmeter (DVM) as a data acquisition system of the input waveform and stored data in memory. The developed algorithm acquires and processes the sampling data to calculate the root mean square (rms) value of the input voltage of DVM which operates at DC 10 V range for better accuracy. The best uncertainty of the AC voltage measurements is $3 {\mu}V/V$ within the frequency range. The best uncertainty of the AC current measurements is better than the $5 {\mu}A/A$ and mainly depend on the current to voltage converter, ac-dc current shunt or Current Transformer (CT), used for the measurement

  • PDF

Identification of DC-Link Capacitance for Single-Phase AC/DC PWM Converters

  • Pu, Xing-Si;Nguyen, Thanh Hai;Lee, Dong-Choon;Lee, Suk-Gyu
    • Journal of Power Electronics
    • /
    • v.10 no.3
    • /
    • pp.270-276
    • /
    • 2010
  • In this paper, a capacitance estimation scheme for DC-link capacitors for single-phase AC/DC PWM converters is proposed. Under the no-load condition, a controlled AC current (30[Hz]) is injected into the input side, which then causes AC voltage ripples at the DC output side. Or, a controlled AC voltage can be directly injected into the DC output side. By extracting the AC voltage/current and power components on the DC output side using digital filters, the capacitance value can be calculated, where the recursive least squares (RLS) algorithm is used. The proposed methods can be simply implemented with software only and additional hardware is not required. From the experiment results, a high accuracy estimation of capacitances less than 0.85% has been obtained.

Design of a Fuzzy-Tuning High Gain Observer for Speed-Sensorless Control of an AC Servo Motor (교류 서보 전동기 속도센서리스 제어를 위한 퍼지 동조 고이득 관측기 설계)

  • Kim, Sang-Hoon;Kim, Lark-Kyo
    • The Transactions of the Korean Institute of Electrical Engineers D
    • /
    • v.54 no.12
    • /
    • pp.705-712
    • /
    • 2005
  • This paper deals with speed-sensorless control of an AC servo motor using Fuzzy-Tuning High Gain Observer(FTHGO). Resolver or encoder can be used to measure a rotor speed, but it has a limit to detect motor speed precisely. To solve this problem, it is studied to measure a speed of an AC servo motor without sensor. In this paper, the gain of an observer to estimate motor speed is properly set up and designed using the fuzzy control theory. It calculates the differentiation of the rotor current of the AC motor and estimates the rotor speed using it. Proposed speed sensorless control is performed using the estimated speed as the control variable. Designed FTHGO is applied to AC servo motor to verify the feasibility of the proposed observer. Feasibility of the FTHGO proposed in this paper is proven comparing the experimental results with/without the speed sensor.

Implementation of Voltage Sag/Swell Compensator using Direct Power Conversion (직접전력변환 방식을 이용한 전압 강하/상승 보상기의 구현)

  • Lee, Sang-Hoey;Cha, Han-Ju;Han, Byung-Moon
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.8
    • /
    • pp.1544-1550
    • /
    • 2009
  • In this paper, a new single phase voltage sag/swell compensator using direct power conversion is proposed. A new compensator consists of input/output filter, series transformer and direct ac-ac converter, which is a single-phase back-to-back PWM converter without dc-link capacitors. Advantages of the proposed compensator include: simple power circuit by eliminating dc link electrolytic capacitors and thereby, improved reliability and increased life time of the entire compensator; simple PWM strategy or compensating voltage sag/swell at the same time and reduced switching losses in the ac-ac converter. Further, the proposed scheme is able to adopt simple switch commutation method without requiring complex four-step commutation method that is commonly employed in the direct power conversion. Simulation and experimental results are shown to demonstrate the advantages of the new compensator and PWM strategy. A 220V, 3kVA single-phase compensator based on the digital signal processor controller is built and tested.