• Title/Summary/Keyword: AC/A

Search Result 6,714, Processing Time 0.031 seconds

Study on an Optimal Control Method for Energy Injection Resonant AC/AC High Frequency Converters

  • Su, Yu-Gang;Dai, Xin;Wang, Zhi-Hui;Tang, Chun-Sen;Sun, Yue
    • Journal of Power Electronics
    • /
    • v.13 no.2
    • /
    • pp.197-205
    • /
    • 2013
  • In energy injection resonant AC-AC converters, due to the low frequency effect of the AC input envelope and the low energy injection losses requirement, the constant and steady control of the high frequency AC output envelope is still a problem that has not been solved very well. With the aid of system modeling, this paper analyzes the mechanism of the envelope pit on the resonant AC current. The computing methods for the critical damping point, the falling time and the bottom value of the envelope pit are presented as well. Furthermore, this paper concludes the stability precondition of the system AC output. Accordingly, an optimal control method for the AC output envelope is put forward based on the envelope prediction model. This control method can predict system responses dynamically under different series of control decisions. In addition, this control method can select best series of control decisions to make the AC output envelope stable and constant. Simulation and experimental results for a contactless power transfer system verify the control method.

Switched Inductor Z-Source AC-DC Converter

  • Sedaghati, Farzad;Hosseini, Seyed Hossein;Sarhangzadeh, Mitra
    • Journal of international Conference on Electrical Machines and Systems
    • /
    • v.1 no.1
    • /
    • pp.67-76
    • /
    • 2012
  • Due to the increasing amount of applications of power electronic ac-dc converters, it is necessary to design a single-stage converter that can reliably perform both buck and boost operations. Traditionally, this can be achieved by double-stage conversion (ac/dc-dc/dc) which ultimately leads to less efficiency and a more complex control system. This paper discusses two types of modern ac-dc converters. First, the novel impedance-source ac-dc converter, abbreviated as custom Z-source rectifier, is analyzed; and then, switched inductor (SL) Z-source ac-dc converter is proposed. This paper describes the Z-source rectifiers' operating principles, the concepts behind them, and their superiorities. Analysis and simulation results show that the proposed custom Z-source rectifier can step up and step down voltage; and the main advantage of the SL Z-source ac-dc converter is its high step-up capability. Low ripple of the output dc voltage is the other advantage of the proposed converters. Finally, the SL Z-source ac-dc converter is compared with the custom Z-source ac-dc converter.

Analysis of the Effect of Alternating Current Ripple on Electrical State of Health Degradation of 21700 Lithium-ion Battery (교류 리플이 21700 리튬 이온 배터리의 전기적 건강 상태 열화에 미치는 영향 분석)

  • Bongwoo Kwak
    • Journal of IKEEE
    • /
    • v.27 no.4
    • /
    • pp.477-485
    • /
    • 2023
  • In this paper, the effect of AC ripple on the lifetime of lithium-ion batteries is experimentally analyzed. Bidirectional power conversion system(PCS) is used to increase the efficiency of energy storage systems (ESS). When connected to the grid, a current ripple with a frequency twice the grid frequency is applied to the battery due to its structure. Therefore, to analyze the effect of AC ripple on Li-ion battery aging, cycle life test are performed by applying charge/discharge profiles of DC current and DC+AC current ripple specifications. Based on the experimental results, direct current internal resistance (DCIR), incremental capacitance (IC), and surface temperature were analyzed. As a result, it is confirmed that AC ripple does not directly affect degradation and that battery degradation slows down after a certain cycle. These results can serve as a guideline for optimizing filters to reduce ripple on the battery side in applications where AC ripple occurs.

Measurement and Numerical Analysis of AC Loss in the HTS Pancake Coil and the HTS Solenid Coil (고온초전도 팬케이크 코일과 솔레노이드 코일의 교류손실 측정 및 수치해석)

  • Park Myung-Jin;Lee Sang-Soo;Lee Seung-Wook;Cha Guee-Soo;Lee Ji-Kwang
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.53 no.12
    • /
    • pp.732-738
    • /
    • 2004
  • In this paper, we constructed 13 turns pancake coil and solenoid coil with HTS tape and measured AC losses of the pancake coil. The critical current of the pancake coil and the solenoid coil were 80A and 109A, respectively. To compare measured AC losses of the two coils, we carried out numerical analysis using 2-D FEM program for manufactured coils. This paper presents current density distribution, flux density distribution and AC losses of the pancake coil and the solenoid. As a result, we obtained that current density distribution was closely related to the orientation of magnetic field and distribution of AC losses were also closely related to the perpendicular component of flux density distribution in coil. The calculated AC losses of the two coils showed good agreement with measured AC losses and AC losses of the pancake coil was about 9 times bigger than that of the solenoid coil under the same turns and length.

Electroluminescent Characteristics of Fluorescent OLED with Alternating Current Negative Voltage (교류 음 전압에 따른 형광 OLED의 전계 발광 특성)

  • Seo, Jung-Hyun;Yang, Jae-Woong;Paek, Kyeong-Kap;Ju, Sung-Hoo
    • Journal of the Korean institute of surface engineering
    • /
    • v.52 no.2
    • /
    • pp.72-77
    • /
    • 2019
  • To study the characteristics of AC driven OLED, we fabricated the fluorescent OLEDs and analyzed the electroluminescence characteristics of OLEDs with AC negative voltage. The luminance and the current density of the OLED decreased, and the number and size of the dark spots increased in proportion to the duration time and level of the applied AC negative voltage. The current efficiency of the OLED was improved when high AC negative voltage was applied within a short time. When the AC negative voltage of 10 V was applied for 1 minute, the efficiency was improved by 12.4%. Also, the degradation of luminance and current efficiency due to the duration of light emission was improved in the case of OLED applied for 1 minute with 10 V AC negative voltage. These are expected as a result of the improvement of the leakage current characteristics by eliminating the short-circuit region formed by the defect of the OLED at the AC negative high voltage. As a result, the continuous application of AC negative voltage reduced the luminance and the current density of OLED, but the temporary application of AC negative voltage with the proper time and voltage could improve the efficiency and lifetime of OLED.

Implementation and Control of AC-DC-AC Power Converter in a Grid-Connected Variable Speed Wind Turbine System with Synchronous Generator (동기기를 사용한 계통연계형 가변속 풍력발전 시스템의 AC-DC-AC 컨버터 구현 및 제어)

  • Song Seung-Ho;Kim Sung-Ju;Hahm Nyon-Kun
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.54 no.12
    • /
    • pp.609-615
    • /
    • 2005
  • A 30kW electrical power conversion system is developed for a variable speed wind turbine. In the wind energy conversion system(WECS) a synchronous generator with field current excitation converts the mechanical energy into electrical energy. As the voltage and the frequency of the generator output vary according to the wind speed, a 6-bridge diode rectifier and a PWM boost chopper is utilized as an ac-dc converter maintaining the constant dc-link voltage with only single switch control. An input current control algorithm for maximum power generation during the variable speed operation is proposed without any usage of speed sensor. Grid connection type PWM inverter converts dc input power to ac output currents into the grid. The active power to the grid is controlled by q-axis current and the reactive power is controlled by d-axis current with appropriate decoupling. The phase angle of utility voltage is detected using software PLL(Phased Locked Loop) in d-q synchronous reference frame. Experimental results from the test of 30kW prototype wind turbine system show that the generator power can be controlled effectively during the variable speed operation without any speed sensor.

An Approach to a Speed Estimation Method to Remove Speed Sensor of Underwater Robot's AC Drive Systems (수중로봇용 AC구동시스템의 속도센서 제거를 위한 속도추정법 연구)

  • 전봉환;임용곤;이판묵
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 1998.05a
    • /
    • pp.371-376
    • /
    • 1998
  • This paper describes an approach to a speed estimation method to remove speed sensor of underwater robot's AC drive systems. AC motors have been widely used in the field of underwater robot's manipulator or propulsion system. Most of these AC motors for underwater use have usually filled oil to compensate the high pressure in deep-sea operation, where a resolver is adopted to feed back the speed of rotor But this kind of speed feedback devices gives rise to some defects arising from their mechanical complexity and numerous signal lines; a resolver needs 6 or 7 signal lines for proper operation. This paper presents a speed estimation method to improve these problems of induction motor, which is adopted as a prototype of AC motor. The proposed speed estimation method is based on the RFO(rotor flux orientation) vector control method of voltage-fed AC drives. Using the controller of voltage-fed AC drives, it is unnecessary to measure the voltage for the estimation of rotor speed, which reduces the effects of measurement error Numerical simulation is carried out to investigate the validity of the method and the effects of rotors resistance variation.

  • PDF

A study on the development of 50W AC direct type engine with integrated reflector starting (리플렉터 일체형 50W급 AC 직결형 엔진개발에 관한 연구)

  • Son, Seok-Geum
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.11 no.4
    • /
    • pp.388-393
    • /
    • 2018
  • In this paper, We developed a high efficiency reflector integrated type 50W AC direct connection type engine to realize miniaturization and weight reduction of product without using SMPS and to design a multistage varistor circuit Reduced costs by reducing the number of parts High reliability is achieved by using a circuit structure that does not use an electrolytic capacitor, thus increasing the lifetime of the LED. In addition, it is possible to manufacture an AC direct-coupled type driving device by using an IC semiconductor and apply an AC direct-coupled type driving device integrated with a reflector so that the lifetime of the device can be fully utilized for the lifetime of the LED, A light source having a plurality of light emitting diode channels including a plurality of light emitting diode channels arranged in series is driven with a rectified voltage.

Survey of Activated Charcoal Administration for Poisoning Patients Visited in Emergency Medical Centers and Emergency Staff's Perception in Korea (국내 응급의료센터의 중독 환자에 있어 활성탄 투여 현황과 응급실 의료진의 인식)

  • Bae, Sung Jin;Choi, Yoon Hee;Lee, Duk Hee
    • Journal of The Korean Society of Clinical Toxicology
    • /
    • v.15 no.1
    • /
    • pp.17-23
    • /
    • 2017
  • Purpose: Activated charcoal (AC) has been widely used as a universal antidote. Currently, emergency medical centers in Korea cannot administer AC due to discontinuation of the supply of commercial ready-mixed AC suspension. This study was conducted to investigate the proportion of emergency medical centers that administer AC to poisoning patients and provide basic information for emergency physicians and toxicologists. Methods: A prospective telephone survey of all of the included emergency medical institutions was conducted. The type of emergency medical institution, average annual number of patients admitted to the emergency department, annual average number of patients who were poisoned and whether the hospital currently utilizes gastric lavage and administration of AC were determined. Results: AC was administered to poisoning patients in 40% of regional emergency medical centers, 59.3% of local emergency medical centers, and 45.9% of local emergency medical rooms. Overall, 37% of total emergency medical institutions did not administer AC due to discontinuation of the commercial ready-mixed AC suspension. Additionally, 77% of emergency physicians in institutions without AC knew AC is necessary for poisoning patients. The rate of vomiting experienced by the medical staff according to types of charcoal showed that the average rate of vomiting was 33% for commercial ready-mixed activated charcoal suspension and 51% for self-prepared charcoal powder (p=0.02). Conclusion: AC should be secured promptly in emergency medical institutions. Before the supply of commercial ready-mixed AC suspension becomes again it is essential to develop a standardized regimen for self-preparation of charcoal powder and to educate emergency physicians and toxicologists to its use.