• 제목/요약/키워드: A1 Matrix

Search Result 6,982, Processing Time 0.039 seconds

Anti-tumor Effect of a Combination of Hongyoung Ethanol Extract and Cisplatinin YD-10B Oral Cancer Cells (YD-10B 구강암세포에서 홍영 에탄올 추출물과 시스플라틴 병용에 의한 항암 효과)

  • Eun-Jung Kim;Sung-Hee Hwang;Sangwook Park
    • Journal of Life Science
    • /
    • v.33 no.6
    • /
    • pp.498-505
    • /
    • 2023
  • Solanum tuberosum Linnaeus cv Hongyoung, which represents red potato, was developed in Korea. Hongyoung is known to have anti-oxidant, anti-inflammatory, anti-viral, and anti-tumor properties, but no research has been conducted on the growth inhibition and apoptosis effects of hongyoung in YD-10B oral cancer cells. In this study, the combined treatment of hongyoung ethanol extract (HEE) and cisplatin were examined to determine its ability to inhibit cancer cell growth, induce apoptosis, and inhibit matrix metalloproteinases (MMP)-2 and MMP-9 cancer metastasis. The cell viability was investigated using a 2-(2-methoxy-4-nitrophenyl)-3-(4-nitrophenyl)-5-(2,4-disulfophenyl)-2H- tetrazolium monosodium salt (MTS) assay, and the ability to induce apoptosis was analyzed using an FACS analyzer. The mRNA expression and protein activity of MMP-2 and MMP-9 were measured via RT-PCR and zymography. The YD-10B oral cancer cells showed an increase in growth inhibition as the concentration of HEE increased. The combination of 200 µM cisplatin and 500 ㎍/ml HEE reduced the growth of the YD-10B oral cancer cells by more than 50% compared to cisplatin alone. When phorbol 12-myristate 13-acetate (PMA)-treated YD-10B oral cancer cells were co-treated with 200 µM cisplatin and 500 ㎍/ml HEE, both the mRNA expression and protein activity of the MMP-2 and MMP-9 decreased. In addition, the percentage of the sub-G1 phase, which indicates apoptosis ability, more than doubled when treated in combination with 200 µM cisplatin and 500 ㎍/ml HEE than when cisplatin alone was used. The results of this study therefore suggest the possibility of using a combination of HEE and cisplatin in the development of effective drugs to treat oral cancer.

A Study on a Effect of Product Design and a Primary factor of Qualify Competitiveness (제품 디자인의 파급효과와 품질경쟁력의 결정요인에 관한 연구)

  • Lim, Chae-Suk;Yoon, Jong-Young
    • Archives of design research
    • /
    • v.18 no.4 s.62
    • /
    • pp.95-104
    • /
    • 2005
  • The purpose of this study is to estimate the determinants of product design and analyze the impacts of product design on quality competitiveness, product reliability, and consumer satisfaction in an attempt to provide a foundation for the theory of design management. For this empirical analysis, this study has derived the relevant measurement variables from a survey on 400 Korean manufacturing firms during the period of $August{\sim}October$ 2003. The empirical findings are summarized as follows: First, the determinants of product design are very significantly (at p<0.001) estimated to be the R&D capability, the level of R&D expenditure, the level of innovative activities(5S, TQM, 6Sigma, QC, etc.). This empirical result can support Pawar and Driva(1999)'s two principles by which the performance of product design and product development can be simultaneously evaluated in the context of CE(concurrent engineering) of NPD(newly product development) activities. Second, the hypothesis on the causality: product design${\rightarrow}$quality competitiveness${\rightarrow}$customer satisfaction${\rightarrow}$customer loyalty is very significantly (at p<0.001) accepted. This implies that product design positively affects consumer satisfaction, not directly but indirectly, by influencing quality competitiveness. This empirical result of this study can also support the studies of for example Flynn et al.(1994), Ahire et at.(1996), Afire and Dreyfus(2000) which conclude that design management is a significant determinant of product quality. The aforementioned empirical results are important in the following sense: the empirical result that quality competitiveness plays a bridging role between product design and consumer satisfaction can reconcile the traditional debate between QFD(quality function development) approach asserted by product developers and conjoint analysis maintained by marketers. The first empirical result is related to QFD approach whereas the second empirical result is related to conjoint analysis. At the same time, the empirical results of this study can support the rationale of design integration(DI) of Ettlie(1997), i.e., the coordination of the timing and substance of product development activities performed by the various disciplines and organizational functions of a product's life cycle. Finally, the policy implication (at the corporate level) from the empirical results is that successful design management(DM) requires not only the support of top management but also the removal of communication barriers, (i.e. the adoption of cross-functional teams) so that concurrent engineering(CE), the simultaneous development of product and process designs can assure product development speed, design quality, and market success.

  • PDF

Relation between Chemical Properties of Soil and Tree Growth (토양(土壤)의 화학적(化學的) 성질(性質)과 임목생장(林木生長)과의 관계(關係))

  • Chung, Young Gwan;Hong, Byung Wha;Kim, Jong Man
    • Journal of Korean Society of Forest Science
    • /
    • v.46 no.1
    • /
    • pp.10-20
    • /
    • 1980
  • This experiment was carried out to investigate the effects of physico-chemical properties of soil on the growth of Chamaecyparis obtusa and to apply the results to such rational forest management as yield forecast and selection of suitable species for a given forest stand. The soil properties observed in this experiment were soil pH, exchangeable pH organic matter, total nitrogen, available $P_2O_5$, cation exchange capacity, exchangeable $H^+$, total base and base saturation. Diameter at breast height (DBH), height and volume growth of C. obtusa were observed at 78 sampling sites. Data were processed into the following series for the analysis of multivariates : inner correlation matrix, multiple correlation coefficients, regression coefficients and partial correlation coefficients. The results are summerized as follows : 1. Multiple correlation coefficients between soil properties and DBH of C. obtusa were .364 for 20-year trees, resulting less efficient for estimating the growth of C. obtusa. However, total base, soil pH and base saturation were considerable characters for better estimation. 2. More efficient multiple correlation coefficients were observed between soil properties and height growth than those between soil properties and DBH, showing .443 for 20-year trees and factors affecting the height growth were similar to those of DBH. 3. Extremely low values of multiple correlation coefficients were estimated between physico-chemical properties of soil and volume growth of C. obtusa resulting low efficient estimation. However, total base contributed highly to volume growth of C. obtusa. Accordingly the most contributable factor for estimating the growth of C. obtusa were total base, soil pH and base saturation. Consequently, these results can be effective for selecting of the reforesting site, and less effective for estimating the growth of C. obtusa.

  • PDF

Development of Simultaneous Analytical Method of Veterinary Antibiotics in Manure using Liquid Chromatography Coupled with Tandem Mass Spectrometry (LC-MS/MS를 이용한 퇴비 및 액비 중 항생제 동시 분석법 개발)

  • Chung, Hyung Suk;Lee, Young Jun;Lee, Han Sol;Rahman, Md. Musfiqur;Kabir, Md. Humayun;Park, Byung-Jun;Kim, Jang-Eok;Shim, Jae-Han
    • Korean Journal of Environmental Agriculture
    • /
    • v.36 no.3
    • /
    • pp.201-210
    • /
    • 2017
  • BACKGROUND: The current study was to monitor of 9 veterinary antibiotics (ceftiofur, clopidol, florfenicol, sulfamethazine, sulfamethoxazole, sulfathiazole, tetracycline, tiamulin, and tylosin) in manure using liquid chromatography-tandem mass spectrometry (LC-MS/MS) in positive and negative electrospray ionization mode. METHODS AND RESULTS: Sample preparation was carried out using Mcllvaine buffer and citrate salts to adjust the pH of the sample followed by purification with dispersive solid phase extraction (d-SPE). Separation of analytes during LC-MS/MS analysis was conducted using an Eclipse Plus $C_{18}$ column and the mobile phase was in gradient mode with, 0.1% formic acid and 5 mM ammonium formate in methanol (A) and 0.1% formic acid and 5 mM ammonium formate in distilled water (B). The linearity of the matrix-matched calibrations of all tested antibiotics was good, with $R^2$ determination coefficients ${\geq}0.9920$. The limit of detection (LOD) and quantifications (LOQ) were $0.1-67.0{\mu}g/kg$ and $0.4-200.0{\mu}g/kg$, respectively. Analysis of 13 solid and liquid manure samples taken from the Republic of Korea revealed concentrations less than $0.7{\mu}g/kg$ for tiamulin, $1497.6{\mu}g/kg$ for sulfamethazine. CONCLUSION: To monitor 9 veterinary antibiotics from manure samples in 13 provincial areas throughout the Republic of Korea, an analytical method was developed. The developed method was fully validated and successfully applied for monitoring various veterinary antibiotics in manure samples.

Development of Simultaneous Analytical Method for Determination of Isoxaflutole and its Metabolite (Diketonitrile) residues in Agricultural Commodities Using LC-MS/MS (LC-MS/MS를 이용한 농산물 중 Isoxaflutole과 대사산물(Diketonitrile)의 동시시험법 개발)

  • Ko, Ah-Young;Kim, Heejung;Do, Jung Ah;Jang, Jin;Lee, Eun-Hyang;Ju, Yunji;Kim, Ji Young;Chang, Moon-Ik;Rhee, Gyu-Seek
    • The Korean Journal of Pesticide Science
    • /
    • v.20 no.2
    • /
    • pp.93-103
    • /
    • 2016
  • A simultaneous analytical method was developed for the determination of isoxaflutole and metabolite (diketonitrile) in agricultural commodities. Samples were extracted with 0.1% acetic acid in water/acetonitrile (2/8, v/v) and partitioned with dichloromethane to remove the interference obtained from sample extracts, adjusting pH to 2 by 1 N hydrochloric acid. The analytes were quantified and confirmed via liquid chromatograph-tandem mass spectrometer (LC-MS/MS) in positive-ion mode using multiple reaction monitoring (MRM). Matrix matched calibration curves were linear over the calibration ranges ($0.02-2.0{\mu}g/mL$) for all the analytes into blank extract with $r^2$ > 0.997. For validation purposes, recovery studies were carried out at three different concentration levels (LOQ, 10LOQ, and 50LOQ) performing five replicates at each level. The recoveries were ranged between 72.9 to 107.3%, with relative standard deviations (RSDs) less than 10% for all analytes. All values were consistent with the criteria ranges requested in the Codex guideline (CAC/GL40, 2003). Furthermore, inter-laboratory study was conducted to validate the method. The proposed analytical method was accurate, effective, and sensitive for isoxaflutole and diketonitrile determination in agricultural commodities.

Effect of Unilateral Renal Perfusion of Cyclosporine and Mitomycin on Rat's Kidney (Cyclosporine과 Mitomycin의 일측성 신관류로 초래되는 백서 신병변에 관한 연구)

  • Baek Seung In;Lim Hyun Suk;Shin Weon Hye;Ko Cheol Woo;Koo Ja Hoon;Kwak Jung Sik
    • Childhood Kidney Diseases
    • /
    • v.2 no.2
    • /
    • pp.138-144
    • /
    • 1998
  • Purpose : The use of cyclosporine and mitomycin in various immunologic or neoplastic disorders has been known to cause wide-ranged nephrotoxic effects including thrombotic microangiopathy. However, the mechanism of nephrotoxicity of these drugs has not been studied adequately, so that present experimental study has been undertaken to find out whether these drugs can cause direct damage to the kidney and to clarify the pathogenetic mechanism of nephrotoxic effect of these drugs. Materials and methods : Sprague-Dawley rats weighing 250-300 gm were used for experimental animals and unilateral renal perfusion technique, modified from the method described by Hoyer et al was used. Isolation of left kidney from systemic circulation was made by clamping aorta and left renal vein and a hole was punctured in the anterior wall of the left renal vein. Cyclosporine (2.5 mg in 4 ml solution) and mitomycin (1.6 mg in 4ml solution) were infused through left renal artery and normal saline was used in control rats. Forty-eight hours after infusion of the drugs, animals were sacrificed and left kidney removed and processed for histologic examination. Total ischemic time of left kidney was less than 15 minutes: Results : Cyclosporine-perfused group showed severe swelling of glomerular endothelial ceil along with swelling of glomerular epithelial cell and interstitial vascular endothelial cell. Mitomycin-perfused group also showed severe swelling of glomerular endothelial and epithelial cells. And in addition to these findings, they demonstrated platelets aggregation, swelling and degranulation of platelets and fibrin accumulation in some of the capillaries, indicating occurrance of thrombotic microangiopathy. Conclusion : present experiment indicates that cyclosporine and mitomycin can cause direct toxic injury to renal endothelial cell. And this direct toxic damage to endothelial cell seems to be an important initiating event for the development of thrombotic microangiopathy.

  • PDF

Comparison of Collimator Choice on Image Quality of I-131 in SPECT/CT (I-131 SPECT/CT 검사의 에서 조준기 종류에 따른 영상 비교 평가)

  • Kim, Jung Yul;Kim, Joo Yeon;Nam-Koong, Hyuk;Kang, Chun Goo;Kim, Jae Sam
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.18 no.1
    • /
    • pp.33-42
    • /
    • 2014
  • Purpose: I-131 scan using High Energy (HE) collimator is generally used. While, Medium Energy (ME) collimator is not suggested to use in result of an excessive septal penetration effects, it is used to improve the sensitivities of count rate on lower dose of I-131. This research aims to evaluate I-131 SPECT/CT image quality using by HE and ME collimator and also find out the possibility of ME collimator clinical application. Materials and Methods: ME and HE collimator are substituted as Siemens symbia T16 SPECT/CT, using I-131 point source and NEMA NU-2 IQ phantom. Single Energy Window (SEW) and Triple Energy Windows (TEW) are applied for image acquisition and images with CTAC and Scatter correction application or not, applied different number of iteration and sub set are reconstructed by IR method, flash 3D. By analysis of acquired image, the comparison on sensitivities, contrast, noise and aspect ratio of two collimators are able to be evaluated. Results: ME Collimator is ahead of HE collimator in terms of sensitivity (ME collimator: 188.18 cps/MBq, HE collimator: 46.31 cps/MBq). For contrast, reconstruction image used by HE collimator with TEW, 16 subset 8 iteration applied CTAC is shown the highest contrast (TCQI=190.64). In same condition, ME collimator has lower contrast than HE collimator (TCQI=66.05). The lowest aspect ratio for ME collimator and HE collimator are 1.065 with SEW, CTAC (+) and 1.024 with TEW, CTAC (+) respectively. Conclusion: Selecting a proper collimator is important factor for image quality. This research finding tells that HE collimator, which is generally used for I-131 scan emitted high energy ${\gamma}$-ray is the most recommendable collimator for image quality. However, ME collimator is also applicable in condition of lower dose, lower sensitive if utilizing energy window, matrix size, IR parameter, CTAC and scatter correction appropriately.

  • PDF

Clinical Utility of Turbo Contrase-Enhanced MR Angiography for the Major Branches of the Aortic Arch (대동맥궁 주요 분지들의 고속 조영증강 자기공명혈관조영술의 임상적 유용성)

  • Su Ok Seong
    • Investigative Magnetic Resonance Imaging
    • /
    • v.2 no.1
    • /
    • pp.96-103
    • /
    • 1998
  • Purpose : To assess the clinical utility of turbo contrast-enhanced magnetic resonance angiography(CE MRA) in the evaluation of the aortic arch and its major branches and to compare the image quality of CE MRA among different coils used. Materials and Methods : Turbo three-phase dynamic CE MRA encompassing aortic arch and its major branches was prospectively performed after manual bolus IV injection of contrast material in 29 patients with suspected cerebrovascular diseases at 1.0T MR unit. the raw data were obtained with 3-D FISH sequence (TR 5.4ms, TE 2.3ms, flip angle 30, slab thickness 80nm, effective slice thickness 4.0mm, matrix size $100{\times}256$, FOV 280mm). Total data acquisition time was 4. to 60 seconds. We subjectively evaluated the imge quality with three-rating scheme : "good" for unequivocal normal finding, "fair" for relatively satisfactory quality to diagnose 'normal' despite intravascular low signal, and "poor" for equivocal diagnosis or non-visualization of the origin or segment of the vessels due to low signal or artifacts which needs catheter angiography. At the level of the carotid bifurcation, it was compared with conventional 2D-TOF MRA image. Overall image quality was also compared visually and quantitatively by measuring signal-to-noise ratios (SNRs) of the ascending aorta, the innominate artery and both common carotid arteries among the three different coils used(CP body array(n=12), CP neck array(n=9), and head-and-neck(n=8). Results : Demonstration of the aortic arch and its major branches was rated as "good" in 55% (16/29) and "fair" in 34%(10/29). At the level of the carotid bifurcation, image quality of turbo CE MRA was same as or better than conventional 2D-TOF MRA in 65% (17/26). Overall image quality and SNR were significantlygreater with CP body array coil than with CP neck array or head-and-neck coil. Conclusions : Turbo CE MRA can be used as a screening exam in the evaluation of the major branches of the aortic arch from their origin to the skull base. Overall imagequality appears to be better with CP body array coil than with CP neck array coil or head-and-neck coil.

  • PDF

Development of Dose Planning System for Brachytherapy with High Dose Rate Using Ir-192 Source (고선량률 강내조사선원을 이용한 근접조사선량계획전산화 개발)

  • Choi Tae Jin;Yei Ji Won;Kim Jin Hee;Kim OK;Lee Ho Joon;Han Hyun Soo
    • Radiation Oncology Journal
    • /
    • v.20 no.3
    • /
    • pp.283-293
    • /
    • 2002
  • Purpose : A PC based brachytherapy planning system was developed to display dose distributions on simulation images by 2D isodose curve including the dose profiles, dose-volume histogram and 30 dose distributions. Materials and Methods : Brachytherapy dose planning software was developed especially for the Ir-192 source, which had been developed by KAERI as a substitute for the Co-60 source. The dose computation was achieved by searching for a pre-computed dose matrix which was tabulated as a function of radial and axial distance from a source. In the computation process, the effects of the tissue scattering correction factor and anisotropic dose distributions were included. The computed dose distributions were displayed in 2D film image including the profile dose, 3D isodose curves with wire frame forms and dosevolume histogram. Results : The brachytherapy dose plan was initiated by obtaining source positions on the principal plane of the source axis. The dose distributions in tissue were computed on a $200\times200\;(mm^2)$ plane on which the source axis was located at the center of the plane. The point doses along the longitudinal axis of the source were $4.5\~9.0\%$ smaller than those on the radial axis of the plane, due to the anisotropy created by the cylindrical shape of the source. When compared to manual calculation, the point doses showed $1\~5\%$ discrepancies from the benchmarking plan. The 2D dose distributions of different planes were matched to the same administered isodose level in order to analyze the shape of the optimized dose level. The accumulated dose-volume histogram, displayed as a function of the percentage volume of administered minimum dose level, was used to guide the volume analysis. Conclusion : This study evaluated the developed computerized dose planning system of brachytherapy. The dose distribution was displayed on the coronal, sagittal and axial planes with the dose histogram. The accumulated DVH and 3D dose distributions provided by the developed system may be useful tools for dose analysis in comparison with orthogonal dose planning.

A CF-based Health Functional Recommender System using Extended User Similarity Measure (확장된 사용자 유사도를 이용한 CF-기반 건강기능식품 추천 시스템)

  • Sein Hong;Euiju Jeong;Jaekyeong Kim
    • Journal of Intelligence and Information Systems
    • /
    • v.29 no.3
    • /
    • pp.1-17
    • /
    • 2023
  • With the recent rapid development of ICT(Information and Communication Technology) and the popularization of digital devices, the size of the online market continues to grow. As a result, we live in a flood of information. Thus, customers are facing information overload problems that require a lot of time and money to select products. Therefore, a personalized recommender system has become an essential methodology to address such issues. Collaborative Filtering(CF) is the most widely used recommender system. Traditional recommender systems mainly utilize quantitative data such as rating values, resulting in poor recommendation accuracy. Quantitative data cannot fully reflect the user's preference. To solve such a problem, studies that reflect qualitative data, such as review contents, are being actively conducted these days. To quantify user review contents, text mining was used in this study. The general CF consists of the following three steps: user-item matrix generation, Top-N neighborhood group search, and Top-K recommendation list generation. In this study, we propose a recommendation algorithm that applies an extended similarity measure, which utilize quantified review contents in addition to user rating values. After calculating review similarity by applying TF-IDF, Word2Vec, and Doc2Vec techniques to review content, extended similarity is created by combining user rating similarity and quantified review contents. To verify this, we used user ratings and review data from the e-commerce site Amazon's "Health and Personal Care". The proposed recommendation model using extended similarity measure showed superior performance to the traditional recommendation model using only user rating value-based similarity measure. In addition, among the various text mining techniques, the similarity obtained using the TF-IDF technique showed the best performance when used in the neighbor group search and recommendation list generation step.