• Title/Summary/Keyword: A-P compression ratio

Search Result 135, Processing Time 0.022 seconds

A Lossless Image Compression using Wavelet Transform with 9/7 Integer Coefficient Filter Bank (9/7텝을 갖는 정수 웨이브릿 변환을 이용한 무손실 정지영상 압축)

  • 추형석;서영천;이태호;전희성;안종구
    • Proceedings of the Korea Institute of Convergence Signal Processing
    • /
    • 2000.08a
    • /
    • pp.253-256
    • /
    • 2000
  • In this paper, we propose the lossless image compression algorithm using the integer wavelet transform. Recently, the S+P transform is widely used and computed with only integer addition and bit-shift operations, but not proper to remove the correlation of smooth images. then we compare the Harr wavelet of the S+P transform with various integer coefficient filter banks and apply 9/7 ICFB to the wavelet transform. In addition, we propose a entropy-coding method that exploits the multiresolution structure and the feedback of the prediction error, and can efficiently compress the transformed image for progressive transmission. Simulation results are compared to the compression ratio using the S+P transform with different types of images.

  • PDF

Evaluation of Physical Properties of Mucosal Adhesive Tablets (II):-Dissolution Rate- (점막 부착정제의 물성평가(II):- 용출속도-)

  • Park, Kwang-Sin;Chung, Bee-Hwan;Cha, Bong-Jin;Kwon, Jong-Won
    • Journal of Pharmaceutical Investigation
    • /
    • v.23 no.1
    • /
    • pp.55-59
    • /
    • 1993
  • Dissolution of mucosal adhesive tablets prepared with two polymers using hydroxypropylcellulose-H (HPC) and carbopol 934 (CP) was tested. Adhesive tablets containing HPC/CP and brilliant blue FCF (BB) were prepared from direct compression. Three factors of polymer ratio (HPC:CP), BB content and compression force were chosen as important factors of preparation and factorial analysis for these factors was carried out. Eight kinds of formulations from different combinations of three factors were prepared and dissolution test in pH 6.8 phosphate buffer solution was performed. Dissolution rate was significantly affected by HPC:CP ratio and BB content, but was not affected by compression force.

  • PDF

A Study on the Theoretical Analysis and Optimal Design Conditions for the $\alpha$ type Stirling Engine ($\alpha$형 스터링 엔진의 최적 설계 조건)

  • 강문규;이택희;유재환
    • Journal of the Korean Society of Safety
    • /
    • v.13 no.4
    • /
    • pp.142-154
    • /
    • 1998
  • A stirling engine is a mechanism used to convert heat to power and operates on a closed regenerative thermodynamic cycle with compression and expansion of the working fluid at different temperature. The performance of a stilting cycle machine is a function of six independent parameters, namely; (1) speed N(r.p.m), (2) pressure of the working fluid p(Pa), (3) ratio of the temperature in the compression and expansion space ${\tau}(=T_C/T_E)$ , (4) ratio of the swept volumes in these two spaces K, (5) phase angle $\alpha$ and (6) dead volume ratio X. This paper describes the procedure and presents the results of computations carried out to establish the optimum combinations of these six parameters for maximum engine output for the machine acting as a prime mover, over a combined temperature range from $300^{\circ}K$ to $1000^{\circ}K$ and dead volume ratio X ranging from 0.1 to 2.0. The output of a stilting cycle machine can be expressed in terms of nondimensional power in several different ways. Four methods were studied in detail, the parameters optimized and design charts and engine power charts prepared. The results of this paper may be useful as a guide to the likely effects on the performance of some of the important design parameters and regenerator design.

  • PDF

DIMENSIONAL CHANGE AND FLEXURAL STRENGTH IN COMPLETE DENTURES FABRICATED BY INJECTION MOLDING AND CONVENTIONAL COMPRESSION PROCESSING (의치상용 레진의 전입 방법에 따른 중합체적변화와 굴곡강도에 관한 연구)

  • Choi Hoon-Dal;Kwon Kung-Rock;Kim Hyeong-Seob;Choi Dae-Gyun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.43 no.4
    • /
    • pp.478-486
    • /
    • 2005
  • Statement of problem : Fracture and dimensional change of an acrylic resin denture are a rather common occurrence. Purpose : The purpose of this study was to compare differences in dimensional changes and flexural strength of separate maxillary complete dentures after immediate deflasking by injection molding and conventional compression processing. Material and method: To evaluate dimensional stability, the maxillary dentures were fabricated by using different materials and methods. Lucitone 199(Dentsply Trubyte. york, pennsylvania, USA) and Vertex(Dentimex, zeist, Netherlands) were used as materials. Compression and injection packing methods were used as processing methods. The impression surface of the dentures was measured by 3D Scann-ing System(PERCEPTRON USA) and overlapped original impression surface of the master cast. To evaluate flexural strength, resin specimens were made according to the different materials, powder/liquid ratio and processing methods. Flexural strength of the complete resin specimens (64mm$\times$10mm$\times$3.3mm) were measured by INSTRON 4467. (INSTRON, England) The data was analyzed by ANOVA, t-test and Tukey test. (p<.05 level of significance) Result: The results were as follows 1. There was no significant differences between master model and denture base for each group in overall dimensional changes. 2. Palatal area was more stable than flange or alveolar area in dimensional stability. but. there was no significant differences among each area. 3. Materials and power/liquid ratio had an effect on flexural strength. (P<.05) Especially materials was most effective. (P<.05) 4. Lucitone 199(powder/liquid ratio followed by manufacturer's direction) showed higher flexural strength than Vertex. Conclusion : Dimensional stability or flexural strength are affected by materials rather than packing techniques.

Secondary Compression Characteristics Caused by Particles Crushing of Sabkha Soil (입자파쇄 특성에 따른 Sabkha층의 이차압축 특성)

  • Kim, Seok-Ju;Bae, Kyung-Tae;Yi, Chang-Tok;Han, Heui-Soo
    • Journal of the Korean Geotechnical Society
    • /
    • v.29 no.11
    • /
    • pp.61-72
    • /
    • 2013
  • The consolidation tests are conducted to investigate the soil particle crushing stress for understanding the secondary compression characteristics of carbonate sandy sabkha soil caused by particle crushing under a high confining stress. The rate of secondary crushing compression ($C_{{\alpha}{\epsilon}}{^*}$) is introduced instead of the rate of secondary compression to define the characteristic of the particle crushing compression settlement ($S_s{^*}$). Void ratio ($e_p{^*}$) and settlement ($H_p{^*}$) in particle crushing are used as a reference point of secondary behavior, and the ratio of primary compression index ($C_c$) to secondary crushing compression ($C_{{\alpha}{\epsilon}}{^*}$), $C_{{\alpha}{\epsilon}}{^*}/C_c$ value was changed from 0.0105 to 0.0187. When comparing with quartz sands, secondary compression settlement of sabkha is very large due to particle crushing which is not usually observed in quartz sand. It is observed that as the depth of sabkha layer becomes deep, the $S_s{^*}$ and $C_{{\alpha}{\epsilon}}{^*}$ increase under the same stress level.

When do we need more than local compression to control intraoral haemorrhage?

  • Sohn, Jun-Bae;Lee, Ho;Han, Yoon-Sic;Jung, Da-Un;Sim, Hye-Young;Kim, Hee-Sun;Oh, Sohee
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.45 no.6
    • /
    • pp.343-350
    • /
    • 2019
  • Objectives: The aims of this study were to determine the effectiveness of local compression in patients presenting to the emergency room with intraoral bleeding and to identify when complex haemostatic measures may be required. Materials and Methods: Five hundred forty patients who had experienced intraoral haemorrhage were retrospectively reviewed. The outcome variable was the haemostasis method used, i.e., simple (local compression with gauze) or complex (an alternative method after local compression has failed). Predictor variables were sex, age, American Society of Anesthesiologists (ASA) class, hepatic cirrhosis, bleeding disorder, use of antithrombotic agents, and site/cause of haemorrhage. Results: The mean patient age was 48.9±23.9 years, 53.5% were male, 42.8% were ASA class II or higher, and 23.7% were taking antithrombotic agents. Local compression was used most often (68.1%), followed by local haemostatic agents, sutures, systemic tranexamic acid or blood products, and electrocautery. The most common site of bleeding was the gingiva (91.7%), and the most common cause was tooth extraction (45.7%). Risk factors for needing a complex haemostasis method were use of antithrombotic agents (odds ratio 2.047, P=0.009) and minor oral surgery (excluding extraction and implant procedures; odds ratio 6.081, P=0.001). Conclusion: A haemostasis method other than local compression may be needed in patients taking antithrombotic agents or having undergone minor oral surgery.

Comparison of Turkish Steel Building Specifications, TS 648 and SDCCSS 2018

  • Bozkurt, Mehmet Bakir;Ergut, Abdulkerim;Ozkilic, Yasin Onuralp
    • Steel and Composite Structures
    • /
    • v.45 no.4
    • /
    • pp.513-533
    • /
    • 2022
  • This study presents similarities and differences between Turkish Building Code for Steel Structures, which are TS 648 and SDCCSS (Specification for Design, Calculation and Construction of Steel Structures) in terms of the design of the members. Hot-rolled I-shaped steel sections for symmetrical and U-shaped steel sections (i.e., channels) for monosymmetric sections were elaborated in detail. The design strength of tension members under tensile load, compression members under axial load and flexural members under flexure and shear were examined separately. Connection details for tension members, slenderness for compression members and distance between lateral supports for flexural members were considered as prime variables. Analysis results revealed the design strength of the tension members where at least one of the cross-sectional parts is not connected to the connection plates, I-shaped compression members where a slenderness ratio is below 39 (𝛌<39), U-shaped compression members and flexural members where Lb is between Lp and Lr (Lpb≤Lr) designed based on TS 648 are greater than those designed based on SDCCSS 2018. Strength differences between the specification can reach 79% for tensile members, 13% for compression members and 9% for flexural members.

Compressibility and hydraulic conductivity of calcium bentonite treated with pH-responsive polymer

  • Choo, Hyunwook;Choi, Youngmin;Kim, Young-Uk;Lee, Woojin;Lee, Changho
    • Geomechanics and Engineering
    • /
    • v.22 no.4
    • /
    • pp.329-337
    • /
    • 2020
  • Polyacrylamide (PAM) possesses high water absorption capacity and a unique pH-dependent behavior that confer large potential to enhance the engineering performance of clays. In this study, calcium bentonite was treated with a nonionic PAM. Flexible-wall permeability test and the consolidation test were performed at different pH values to evaluate the effects of PAM treatment on the hydraulic and consolidation properties. Test results demonstrate that index properties are affected by the adsorbed PAM on clay surface: a decrease in specific gravity, a decrease in net zeta potential, and an increase in liquid limit are observed due to the PAM treatment. At a given pH, the compressibility of the treated clay is greater than that of the untreated clay. However, the compression indices of untreated and treated clays can be expressed as a single function of the initial void ratio, regardless of pH. Hydraulic conductivity is reduced by PAM treatment about 5 times at both neutral and alkaline pH conditions under similar void ratios, because of the reduction in size of the water flow channel by PAM expansion. However, at acidic pH, the hydraulic conductivity of the treated clay is slightly higher than the untreated clay. This reflects that the treated bentonite with PAM can be beneficially used in barrier system for highly alkaline residues.

A Study on Evolutionary Computation of Fractal Image Compression (프랙탈 영상 압축의 진화적인 계산에 관한 연구)

  • Yoo, Hwan-Young;Choi, Bong-Han
    • The Transactions of the Korea Information Processing Society
    • /
    • v.7 no.2
    • /
    • pp.365-372
    • /
    • 2000
  • he paper introduces evolutionary computing to Fractal Image Compression(FIC). In Fractal Image Compression(FIC) a partitioning of the image into ranges is required. As a solution to this problem there is a propose that evolution computation should be applied in image partitionings. Here ranges are connected sets of small square image blocks. Populations consist of $N_p$ configurations, each of which is a partitioning with a fractal code. In the evolution each configuration produces $\sigma$ children who inherit their parent partitionings except for two random neighboring ranges which are merged. From the offspring the best ones are selected for the next generation population based on a fitness criterion Collage Theorem. As the optimum image includes duplication in image data, it gets smaller in saving space more efficient in speed and more capable in image quality than any other technique in which other coding is used. Fractal Image Compression(FIC) using evolution computation in multimedia image processing applies to such fields as recovery of image and animation which needs a high-quality image and a high image-compression ratio.

  • PDF

Compression of time-varying volume data using Daubechies D4 filter (Daubechies D4 필터를 사용한 시간가변(time-varying) 볼륨 데이터의 압축)

  • Hur, Young-Ju;Lee, Joong-Youn;Koo, Gee-Bum
    • 한국HCI학회:학술대회논문집
    • /
    • 2007.02a
    • /
    • pp.982-987
    • /
    • 2007
  • The necessity of data compression scheme for volume data has been increased because of the increase of data capacity and the amount of network uses. Now we have various kinds of compression schemes, and we can choose one of them depending on the data types, application fields, the preferences, etc. However, the capacity of data which is produced by application scientists has been excessively increased, and the format of most scientific data is 3D volume. For 2D image or 3D moving pictures, many kinds of standards are established and widely used, but for 3D volume data, specially time-varying volume data, it is very difficult to find any applicable compression schemes. In this paper, we present a compression scheme for encoding time-varying volume data. This scheme is aimed to encoding time-varying volume data for visualization. This scheme uses MPEG's I- and P-frame concept for raising compression ratio. Also, it transforms volume data using Daubechies D4 filter before encoding, so that the image quality is better than other wavelet-based compression schemes. This encoding scheme encodes time-varying volume data composed of single precision floating-point data. In addition, this scheme provides the random reconstruction accessibility for an unit, and can be used for compressing large time-varying volume data using correlation between frames while preserving image qualities.

  • PDF