• Title/Summary/Keyword: A-KRS

Search Result 60, Processing Time 0.032 seconds

Korean Reference Disposal System for High-level Radioactive Wastes

  • Choi Heui-Joo;Choi Jongwon;Lee Jong Youl
    • Proceedings of the Korean Radioactive Waste Society Conference
    • /
    • 2005.11b
    • /
    • pp.225-235
    • /
    • 2005
  • This paper outlined the status of the development of Korean Reference Disposal (KRS­1) system for high-level radioactive wastes. The repository concept was based on the engineering barrier system which KAERI has developed through a long-term research and development program. The design requirements were prepared for the conceptual design of the repository. The amount of PWR and CANDU spent fuels were projected with the current nuclear power plan. The disposal rates of PWR and CANDU spent fuels were analyzed. The reference geologic characteristics including classification of fracture zones were set for the KRS. The disposal concepts and the layout of the repository were described.

  • PDF

A Study on Certification Procedure of Railway Supplies (철도용품의 품질인증을 위한 절차 고찰)

  • Chang, Seok-Gahk;Baek, Seung-Koo;Kwon, Sung-Tae
    • Proceedings of the KSR Conference
    • /
    • 2006.11b
    • /
    • pp.1097-1102
    • /
    • 2006
  • Under the necessity certification of railway supplies, an applicant should check the procedure of urban railway law and the new railway safety law. Currently, the Korean railway standards (KRS), formerly managed by Korea Railroad, have been managed by the Korean Ministry of Construction and Transportation. According to Korean railway safety law and its ordinances, which were committed to Korea Railroad Research Institute. It were established for the guarantee of railway safety, the management of KRS including enactment and revision of technical standards for railway vehicle and components. In this investigation, the detailed management procedure will be introduced for the effective management of Certification of Railway Supplies.

  • PDF

Conformity Assessment of Vertical Static Stiffness Test Method for Rail Pad (레일패드 정적 수직강성 시험방법의 적합성 평가)

  • Bae, Young-Hoon;Kim, Man-Cheol
    • Journal of the Korean Society for Railway
    • /
    • v.18 no.1
    • /
    • pp.33-42
    • /
    • 2015
  • The vertical static stiffness of rail pads or baseplate pads, which are important components in rail fastening systems for track safety, is a key factor to determine the total track stiffness and a guideline of quality control in the manufacturing process. The vertical static stiffness can be checked by laboratory testing: test methods are EN 13146-9 and KRS TR 0014, which are widely used in the railway field. In this paper, to correct some problems, namely the preloading step, the unloading level, and the holding time in the loading program in the vertical static stiffness test of EN 13146-9 and KRS TR 0014, domestic and foreign test standards of pads were analyzed and then certain schemes for a vertical static stiffness test were proposed. To assess the reliability of the proposed schemes, the vertical static stiffness tests were performed with 4 pads and the validity of the test results was estimated.

A Numerical Study of the Performance Assessment of Coupled Thermo-Hydro-Mechanical (THM) Processes in Improved Korean Reference Disposal System (KRS+) for High-Level Radioactive Waste (수치해석을 활용한 향상된 한국형 기준 고준위방사성폐기물 처분시스템의 열-수리-역학적 복합거동 성능평가)

  • Kim, Kwang-Il;Lee, Changsoo;Kim, Jin-Seop
    • Tunnel and Underground Space
    • /
    • v.31 no.4
    • /
    • pp.221-242
    • /
    • 2021
  • A numerical study of the performance assesment of coupled thermo-hydro-mechanical (THM) processes in improved Korean reference disposal system (KRS+) for high-level radioactive waste is conducted using TOUGH2-MP/FLAC3D simulator. Decay heat from high-level radioactive waste increases the temperature of the repository, and it decreases as decay heat is reduced. The maximum temperature of the repository is below a maximum temperature criterion of 100℃. Saturation of bentonite buffer adjacent to the canister is initially reduced due to pore water evaporation induced by temperature increase. Bentonite buffer is saturated 250 years after the disposal of high-level radioactive waste by inflow of groundwater from the surrounding rock mass. Initial saturation of rock mass decreases as groundwater in rock mass is moved to bentnonite buffer by suction, but rock mass is saturated after inflow of groundwater from the far-field area. Stress changes at rock mass are compared to the Mohr-Coulomb failure criterion and the spalling strength in order to investigate the potential rock failure by thermal stress and swelling pressure. Additional simulations are conducted with the reduced spacing of deposition holes. The maximum temperature of bentonite buffer exceeds 100℃ as deposition hole spacing is smaller than 5.5 m. However, temperature of about 56.1% volume of bentonite buffer is below 90℃. The methodology of numerical modeling used in this study can be applied to the performance assessment of coupled THM processes for high-level radioactive waste repositories with various input parameters and geological conditions such as site-specific stress models and geothermal gradients.

A Study of Testing Procedure Temperature of Electronic Equipment for Railway Environments (Cold and Heat) (철도용 전자기기의 온도환경(내한성, 내열성)에 대한 시험검사 절차에 대한 분석연구)

  • Kim, Jin-Hwan;Yang, Doh-Chul
    • Proceedings of the KSR Conference
    • /
    • 2011.10a
    • /
    • pp.748-753
    • /
    • 2011
  • Generally, in the temperature and environment test of railway electronics, cold and heat resistant tests are involved. Relevant KRS standards describe "There is no problem" as acceptance criteria for function check during the temperature and environment tests. According to this requirement, testers perform some function and performance tests which are easy to perform during test procedure using temperature chamber. This paper reviews the limit of current check method for cold and heat resistant tests and proposes an alternative. An alternative is the application of data sheet. Using data sheet, the temperature of equipped components is checked whether this temperature meet acceptance criteria or not. Also, this paper suggests temperature test range guidelines comparing temperature standards for general IC component. For the example in real field, this method uses the lowest temperature and the highest temperature in major domestic cities.

  • PDF

Research on Design of DDS-based Conventional Railway Signal Data Specification for Real-time Railway Safety Monitoring and Control (실시간 철도 안전관제를 위한 DDS 기반의 일반철도 신호 데이터 규격 설계 연구)

  • Park, Yunjung;Lim, Damsub;Min, Dugki;Kim, Sang Ahm
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.20 no.4
    • /
    • pp.739-746
    • /
    • 2016
  • The real-time railway safety monitoring and control system is for prevention of safety accidents, and this system adopts DDS (Data Distribution Service) standard based data transmission method to support integrated management of data from existing on-site safety detection devices. In this paper, we introduce the design of DDS-based data specification from on-site signal equipment on the conventional railway. For this, we (1) design UML data model of KRS SG 0062 standard which defines existing data specification, (2) define DDS Topics for DDS transmission and map KRS model to DDS Topic model, (3) suggest data transformation rules and (4) design network control QoS polices. In addition, we analysis actual on-site log data and validate our data specification design. DDS-based data transmission enables data compatibility among on-site devices and the real-time railway safety monitoring and control system, and allows efficient network management for a large amount of data transfer.

Identification of Novel Bioactive Hexapeptides Against Phytopathogenic Bacteria Through Rapid Screening of a Synthetic Combinatorial Library

  • Choi, Jae-Hyuk;Moon, Eun-Pyo
    • Journal of Microbiology and Biotechnology
    • /
    • v.19 no.8
    • /
    • pp.792-802
    • /
    • 2009
  • Antimicrobial peptides (AMPs) are considered to be a promising alternative to conventional antibiotics for future generations. We identified four novel hexapeptides with antimicrobial activity: KCM11 (TWWRWW-$NH_2$), KCM12 (KWRWlW-$NH_2$), KCM21 (KWWWRW-$NH_2$), and KRS22 (WRWFIH-$NH_2$), through positional scanning of a synthetic peptide combinatorial library (PS-SCL). The ability of these peptides to inhibit the growth of a variety of bacteria and unicellular fungi was evaluated. KCM11 and KRS22 preferentially inhibited the normal growth of fungal strains, whereas KCM12 and KCM21 were more active against bacterial strains. Bactericidal activity was addressed in a clear zone assay against phytopathogenic bacteria, including Pectobacterium spp., Xanthomonas spp., Pseudomonas spp., etc. KCM21 showed the highest activity and was effective against a wide range of target organisms. Application of KCM21 with inoculation of Pectobacterium carotovorum subsp. carotovorum on detached cabbage leaves resulted in an immune phenotype or a significant reduction in symptom development, depending on the peptide concentration. Cytotoxicity of the four hexapeptides was evaluated in mouse and human epithelial cell lines using an MTT test. The results revealed a lack of cytotoxic effects.

The Ignition Characteristics of Dead Leaves and Living Leaves of Various Trees in Young Dong Forest Areas (영동지역 주요 수종별 낙엽과 생엽의 착화특성에 관한 연구)

  • Park, Young-Ju;Lee, Si-Young;Sin, Young-Ju;Kim, Su-Young;Kim, Young-Tak;Lee, Hae-Pyeong
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2008.04a
    • /
    • pp.298-302
    • /
    • 2008
  • In this study, we have carried out the test to examine the ignition characteristics, such as a relation of moisture content and combustibility, and ignition temperature using KRS-RG-9000 tester, living leaves and dead leaves of significant 7 species of Young Dong Provinces of Korea after and before the rainfall. After 144 hours at normal temperature, the percentage of water content of the needle-shaped leaves was less than 10%. So it is suppose to be ignite easily. On the other hand, the self-temperature to ignite of broadleaf is higher. So the retard time at lower temperature is more long than needle-shaped leaf. Consequently, the fire-resistant qualities of broadleaf is higher than needle-shaped leaf.

  • PDF

Numerical Analysis of Coupled Thermo-Hydro-Mechanical (THM) Behavior at Korean Reference Disposal System (KRS) Using TOUGH2-MP/FLAC3D Simulator (TOUGH2-MP/FLAC3D를 이용한 한국형 기준 처분시스템에서의 열-수리-역학적 복합거동 특성 평가)

  • Lee, Changsoo;Cho, Won-Jin;Lee, Jaewon;Kim, Geon Young
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.17 no.2
    • /
    • pp.183-202
    • /
    • 2019
  • For design and performance assessment of a high-level radioactive waste (HLW) disposal system, it is necessary to understand the characteristics of coupled thermo-hydro-mechanical (THM) behavior. However, in previous studies for the Korean Reference HLW Disposal System (KRS), thermal analysis was performed to determine the spacing of disposal tunnels and interval of disposition holes without consideration of the coupled THM behavior. Therefore, in this study, TOUGH2-MP/FLAC3D is used to conduct THM modeling for performance assessment of the Korean Reference HLW Disposal System (KRS). The peak temperature remains below the temperature limit of $100^{\circ}C$ for the whole period. A rapid rise of temperature caused by decay heat occurs in the early years, and then temperature begins to decrease as decay heat from the waste decreases. The peak temperature at the bentonite buffer is around $96.2^{\circ}C$ after about 3 years, and peak temperature at the rockmass is $68.2^{\circ}C$ after about 17 years. Saturation of the bentonite block near the canister decreases in the early stage, because water evaporation occurs owing to temperature increase. Then, saturation of the bentonite buffer and backfill increases because of water intake from the rockmass, and bentonite buffer and backfill are fully saturated after about 266 years. The stress is calculated to investigate the effect of thermal stress and swelling pressure on the mechanical behavior of the rockmass. The calculated stress is compared to a spalling criterion and the Mohr-Coulumb criterion for investigation of potential failure. The stress at the rockmass remains below the spalling strength and Mohr-Coulumb criterion for the whole period. The methodology of using the TOUGH2-MP/FLAC3D simulator can be applied to predict the long-term behavior of the KRS under various conditions; these methods will be useful for the design and performance assessment of alternative concepts such as multi-layer and multi-canister concepts for geological spent fuel repositories.