• Title/Summary/Keyword: A-, D-최적계획

Search Result 163, Processing Time 0.021 seconds

Image Evaluation for Optimization of Radiological Protection in CBCT during Image-Guided Radiation Therapy (영상유도 방사선 치료 시 CBCT에서 방사선 방호최적화를 위한 영상평가)

  • Min-Ho Choi;Kyung-Wan Kim;Dong-Yeon Lee
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.3
    • /
    • pp.305-314
    • /
    • 2023
  • With the development of medical technology and radiation treatment equipment, the frequency of high-precision radiation therapy such as intensity modulation radiation therapy has increased. Image-guided radiation therapy has become essential for radiation therapy in precise and complex treatment plans. In particular, with the introduction of imaging equipment for diagnosis in a linear accelerator, CBCT scanning became possible, which made it possible to calibrate and correct the patient's posture through 3D images. Although more precise reproduction of the patient's posture has become possible, the exposure dose delivered to the patient during the image acquisition process cannot be ignored. Radiation optimization is necessary in the field of radiation therapy, and efforts to reduce exposure are necessary. However, when acquiring 3D CBCT images by changing the imaging conditions to reduce exposure, there should be no image quality or artefacts that would make it impossible to align the patient's position. In this study, Rando phantom was used to scan and evaluate images for each shooting condition. The highest SNR was obtained at 100 kV 80 mA 25 ms F1 filter 180°. As the tube voltage and tube current increased, the noise decreased, and the bowtie filter showed the optimal effect at high tube current. Based on the actual scanned images, it was confirmed that patient alignment was possible under all imaging conditions, and that image-guided radiation therapy for patient alignment was possible under the condition of 70 kV 10 mA 20 ms F0 filter 180°, which showed the lowest SNR. In this study, image evaluation was conducted according to the imaging conditions, and low tube voltage, tube current, and small rotation angle scan are expected to be effective in reducing radiation exposure. Based on this, the patient's exposure dose should be kept as low as possible during CBCT imaging.

Within Field Distribution Pattern and Design of a Sampling Plan for Damaged Onions by the Onion maggot, Hylemya antiqua Meigen(Diptera: Anthomyiidae) (고자리파리에 의한 양파피해(被害)의 포장내(圃場內) 분포양식(分布樣式)과 피해량(被害量) 추정(推定)을 위한 표본추출(標本抽出) 계획(計劃))

  • Park, C.G.;Hyun, J.S.;Cho, D.J.;Lee, K.S.;Hah, J.K.
    • Korean journal of applied entomology
    • /
    • v.24 no.1 s.62
    • /
    • pp.29-33
    • /
    • 1985
  • Every plant in $990m^2$ onion field was inspected for damages by the onion maggot. Maps were constructed every ten days to show which plants were infested and which were not from April 11 to May 21, 1984. The maps were sectioned into squares one of which contains 80 onion plants and the counts of damaged onions in each square were fitted to poisson and negative binomial distribution and tested by chi-square. We argue that the satisfactory fitness of the expected negative binomial $[P(x^2)>0.05]$ provided a useful description of the spatial distribution patterns of the damaged onions. Edge effect was tested by the differences of damage ratio and variance/mean ratio (${\sigma}^2/m$) between edge and center part. The result showed that the damage ratioes and variances of all the periods, ${\sigma}^2/m$ values after May 1 were greater in edge part than in center part. Again, the maps were sectioned into four blocks and the squares (sample units) were sectioned into quadrants. By application of the variance component technique, it was suggested that $2{\sim}8$ sample units for 5% sampling error and $1{\sim}2$ sample units for 10% error should be sampled randomly to estimate the damage ratio when $2{\sim}3$ quadrants were inspected.

  • PDF

Genetic Diversity of Korean Native Chicken Populations in DAD-IS Database Using 25 Microsatellite Markers (초위성체 마커를 활용한 가축다양성정보시스템(DAD-IS) 등재 재래닭 집단의 유전적 다양성 분석)

  • Roh, Hee-Jong;Kim, Kwan-Woo;Lee, Jinwook;Jeon, Dayeon;Kim, Seung-Chang;Ko, Yeoung-Gyu;Mun, Seong-Sil;Lee, Hyun-Jung;Lee, Jun-Heon;Oh, Dong-Yep;Byeon, Jae-Hyun;Cho, Chang-Yeon
    • Korean Journal of Poultry Science
    • /
    • v.46 no.2
    • /
    • pp.65-75
    • /
    • 2019
  • A number of Korean native chicken(KNC) populations were registered in FAO (Food and Agriculture Organization) DAD-IS (Domestic Animal Diversity Information Systems, http://www.fao.org/dad-is). But there is a lack of scientific basis to prove that they are unique population of Korea. For this reason, this study was conducted to prove KNC's uniqueness using 25 Microsatellite markers. A total of 548 chickens from 11 KNC populations (KNG, KNB, KNR, KNW, KNY, KNO, HIC, HYD, HBC, JJC, LTC) and 7 introduced populations (ARA: Araucana, RRC and RRD: Rhode Island Red C and D, LGF and LGK: White Leghorn F and K, COS and COH: Cornish brown and Cornish black) were used. Allele size per locus was decided using GeneMapper Software (v 5.0). A total of 195 alleles were observed and the range was 3 to 14 per locus. The MNA, $H_{\exp}$, $H_{obs}$, PIC value within population were the highest in KNY (4.60, 0.627, 0.648, 0.563 respectively) and the lowest in HYD (1.84, 0.297, 0.286, 0.236 respectively). The results of genetic uniformity analysis suggested 15 cluster (${\Delta}K=66.22$). Excluding JJC, the others were grouped in certain cluster with high genetic uniformity. JJC was not grouped in certain cluster but grouped in cluster 2 (44.3%), cluster 3 (17.7%) and cluster8 (19.1%). As a results of this study, we can secure a scientific basis about KNC's uniqueness and these results can be use to basic data for the genetic evaluation and management of KNC breeds.