• Title/Summary/Keyword: A type

Search Result 84,941, Processing Time 0.091 seconds

Separation Performance of Disc Plate and Frame Type Reverse Osmosis System (원판틀형 역삼투 시스템의 투과성능)

  • 노상호;이종일;김영채;배성렬;정건용
    • Membrane Journal
    • /
    • v.10 no.3
    • /
    • pp.155-162
    • /
    • 2000
  • The reverse osmosis membrane housing(HY) was developed for excellent distribution of a feed solution, and the separation performance was compared with the commercialized Rochem(RC) system. The permeation flux of HY system was a little lower than that of RC system. On the other hand, the NaCl rejection ra4io was generally higher. Also, the permeation flux and rejection ratio for type A, B and C modules(disc plate and frame type) were measured using NaCl, sucrose and butanol solutions. The separation performance of type C module for NaCL and sucrose solutions was the most effective, and then those of type A and B were followed, respectively. However, the separation performance for butanol solution was type B, C and A order. The flux improvement ratio of type B to A increased as butanol concentration decreased or operating pressure increased up to 28 bar.

  • PDF

Comparative of Energy-Saving by Green Roof Type on Urban Office Building (도심 오피스건물의 옥상녹화 조성 유형별 건물에너지 절감 비교 연구)

  • Kim, Jeong-Ho;Kwon, Ki-Uk;Joo, Chang-Hun;Yoon, Yong-Han
    • Journal of Environmental Science International
    • /
    • v.23 no.8
    • /
    • pp.1437-1446
    • /
    • 2014
  • This study, the urban energy used office building green roof type composition of the target by analyze building energy reductions. Green roof is total 6 types(type A~F) were selected, EnergyPlus the energy simulation programs were used. Top floor of green roof types evaluation, the reduction of the cooling peak load type E(1.26%), type D(1.30%), type C(1.37%), type B(1.45%), type F(1.49%), and heating peak load is type D(1.32%), type E(1.40%), type C(1.47%), type F(1.69%), type B(2.13%) order. Annual cooling load of heating load is reduced more than about 1% effect. The heating load reduction ratio for a maximum of 9% respectively. Cooling peak load of the building energy performance evaluation of type F > type B > type C > type D > type E in the order and in the case of peak loads heating type B > type F > type D > type E>type C order. Annual total energy use reduction of 1.07 to 1.22% and earn, type B in the best good. In primary energy use reductions in the presence of a green roof were in the 4249~4876 kWh/yr. Annual $CO_2$ emissions reductions of unapplied type A were analyzed on average 469.78 kg.

A Study on the Analysis of the View Target in an Apartment Unit (아파트 각 단위세대에서 보이는 조망 경관 대상 분석에 관한 연구)

  • Kwon, Young-Taek;Moon, Ji-Won;Ha, Jae-Myung
    • Proceeding of Spring/Autumn Annual Conference of KHA
    • /
    • 2004.11a
    • /
    • pp.221-226
    • /
    • 2004
  • View targets have been studied extensively in terms of an aesthetic value and a monetary asset. But there was actually deficient in the research about a variety of view targets. Therefore, the purpose of this paper was to classify systematically into diverse view targets in an apartment unit by the use of both the literature methods and the questionnaire-interview survey. In result, the view targets in an apartment unit were categorized by two large groups which are a natural-type and an artificial-type view. The former was subdivided into a pure natural-type and a man-made natural-type view, while the latter was subdivided into a building-type, a street-furniture-type, a road-type, a open-space-type, and a tower-type view. Consequently, this study might be applied to the understanding of the quality of residential environment as a basis.

  • PDF

Finite Element Analysis of Windmill Type Ultrasonic Motors Depend on the Shape of Ceramics (세라믹 형상에 따른 풍차형 초음파 모터의 유한요소해석)

  • Lee, Jae-Hyung;Park, Tae-Gone;Kim, Myung-Ho
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.07b
    • /
    • pp.674-677
    • /
    • 2002
  • In this paper, two kinds of windmill type motors which have a disk shape and a ring shape piezoelectric ceramics were studied. And characteristics of two models were compared with each others. A windmill type ultrasonic motor is composed of a stator, a rotor, and a ball bearing. The stator is made of a piezoelectric ceramics and two metals endcaps. When the piezoelectric ceramics vibrate, displacement of torsonal vibration appear at metal endcaps. The motor with 11.0[mm] diameter was studied by finite element analysis. The voltage of 100[V] was supplied at each model. Resonance frequency of 206.875[KHz] was obtained at the disk type, but ring type was 137.562[KHz]. The maximum torsonal displacement of $1.112[{\mu}m]$ was obtained at the disk type, but ring type was $1.698[{\mu}m]$.

  • PDF

A Study on the Connection Type in e-Marketplace (e-마켓플레이스의 연계유형에 관한 연구)

  • 최형림;박남규;황성원;이창섭;박민선
    • Proceedings of the CALSEC Conference
    • /
    • 2003.09a
    • /
    • pp.172-177
    • /
    • 2003
  • As the electronic commerce in industry is spreading rapidly, the invitation and investment of e-marketplace is becoming a necessary condition for the industry's competition power insurance and existence. The successful conditions of e-marketplace are many supplier, many buyer, a globalism through the association and cooperation of a foreign marketplace. For that, the connection action inter industries and marketplaces is very necessary, In a condition of the study about the systematic connection type's classification is not exist, the paper aims at classifying the connection type that influences of e-marketplace playing a leading role. So, the connection type classifies into the list offering type, the trade mediation type, the supplementation type, the collaboration type, the information linking type. When we go ahead with a e-marketplace's plan, the paper will guide how to approach and analyze it.

  • PDF

Effects of Vine Induction Method on the Growth and Fruit Yield in Korean Schisandra (오미자 덩굴 유인방법이 생육 및 과실 수량에 미치는 영향)

  • Kim, Ju Ho;Lee, Beom Gyun;Choi, Eun Young
    • Korean Journal of Medicinal Crop Science
    • /
    • v.25 no.2
    • /
    • pp.83-88
    • /
    • 2017
  • Background: This study was aimed to determine the optimal vine induction method for growing of Korean schisandra (Schisandra chinensis), by comparing plant growth and fruit yields between plants grown with either fence-type (U-type) or A-type induction. Methods and Results: Plants were transplanted on August 17, 2014, and the plant height, stem node number and weight were measured every two weeks, six times from June 17, 2016. The plant height, stem node number, and leaf length and width were higher with the A-type than with the U-type induction, by approximately 37.0%, 49.1%, 27.6%, and 12.7%, respectively. Although there was no significant difference between the photosynthesis rates of plants grown with the two vine induction method, the leaf area and leaf number per plant were higher in the plants grown with the A-type than the U-type, by approximately 23.7% and 46.0%, respectively. The number of green-color pixels, in a defined area of digital camera images of creeper leaves from the inducted vines, was significantly higher in the plants grown with the A-type than the U-type. The number of fruit clusters per plant was approximately 26 and 36, under the U-type and A-type, respectively. A two fold higher total fruit weight per plant was observed in the plants grown under the A-type (250 g/plant) than the U-type (120 g/plant). Conclusions: The A-type vine induction method is optimal for cultivation of Korean schisandra.

A Study on the Classification by the Spatial Index of the University Campuses (대학 캠퍼스 공간적 지표에 의한 유형화에 관한 연구)

  • Kim, Cheon-Il;Shin, So-Young;Kim, Ick-Hwan
    • Journal of the Korean Institute of Educational Facilities
    • /
    • v.23 no.4
    • /
    • pp.3-10
    • /
    • 2016
  • This paper presents the investigation results on the classification of the university campuses. For the classification, we selected the spatial index as the evaluation indicator since the environmental factors and maintenance methods vary from university campus to university campus. For the study, we used eight spatial indices of the 30 national universities. This paper provides the spatial characteristics of different campus types, presents campus classification analysis as a future research approach to campus maintenance, and provides the data for the future study of comparison among universities. The results are as follows. 1) The classification investigation categorized the university campuses into three groups. Type 1 is a large-scale type, located near downtown. Type 2 is a medium-scale type, located at a remote site from downtown. Type 3 is a small-scale type, which is located comparatively near downtown. 2) Type 1 is a large-scale mixed area type, and 13 universities belong to this group. Type 2 is a medium-scale suburban area type, and six universities are in this group. Finally, Type 3 is a small-scale downtown area type, and 11 universities belong to this group.

Girder Section of Continuous Bridges Spliced by Partial Post-Tensioning (부분 포스트텐션닝 방법에 의해 연속화된 교량의 주형단면)

  • 이환우;곽효경;송영용
    • Journal of the Korea Concrete Institute
    • /
    • v.12 no.6
    • /
    • pp.43-50
    • /
    • 2000
  • In this paper, a new splicing method was applied to design the girder section of bridges with the span length of 25m, 30m, 35m, 40m and 45m. A U-type precast prestressed section was also determined for each bridge. Additionally, the sectional area, beam depth and Guyon's efficiency factor of the spliced U-type sections in each span were analyzed in comparison with the present I-type PSC bridges. As a result, in spite of an increase of 31%∼50% in the sectional areas compared with the I-type precast girders, the spliced U-type the beam depth of the spliced U-type girder was designed as 2,050 mm compared with the I-type precast girder of 2,600mm in a 40m span bridge. The sectional efficiency factors of the spliced U-type sections were analyzed as 0.76∼0.99. It shows that the spliced U-type sections ar of a superior structural efficiency in contrast to the average sectional efficiency factor of 0.66 value in the I-type girders.

Development of Battery Type Powered Handpiece Drive System for Surgical Operation (Battery type 외과수술용 핸드피스 구동 드라이브 시스템)

  • Ha, Jung-Jun;Yoon, Yong-Ho
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.57 no.4
    • /
    • pp.388-394
    • /
    • 2008
  • The purpose of this paper is concerned with a battery type powered handpiece drive system for surgical operation. Battery type powered surgical handpiece is suitable for delicate surgical operating. The conventional air-type handpiece has a mechanical noise, a strong oscillation and a danger of infection. And the conventional contact switching type handpiece has problems that is restricted by surroundings. By reason of this kind, we studied noncontact switching type surgical handpiece to change conventional air type surgical handpiece and contact switching type. Also in this paper we develop the battery type power handpiece drive system for surgical operation using controller IC UC3625 of UNITRODE CO. Finally some experimental and simulation results are provided to demonstrate the validity of the proposed battery type power handpiece drive system.

A Study on The Performance of Ventilation and Thermal Environment for a Combined Type Diffuser in a Residential Space (거주공간에 대한 급·배기 일체형 디퓨저의 환기 및 온열환경 유지성능에 대한 연구)

  • Lim, Seok-Young;Chang, Hyun-Jae
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.29 no.2
    • /
    • pp.74-81
    • /
    • 2017
  • In this study, the combined-type diffuser developed by the Authors, in a previous study, was applied to a residential space. The performance of a ventilation and thermal environment, created by the use of a combined-type diffuser was compared to the pan-type diffuser widely used in apartment houses. In cooling conditions, because of the relatively high air flow rate of ceiling cassette-type air conditioners, the characteristics of airflow distribution in a room were governed by the air conditioner's airflow. In heating conditions, because of the low air flow rate of the diffuser, the characteristics of airflow distribution were governed by the buoyancy effect created by cold external walls and a hot floor. In terms of the Air Diffusion Performance Index (ADPI), which is a thermal environmental index, the result of a combined-type diffuser was greater than a pan-type diffuser in both of cooling and heating conditions. Consequently, the combined-type diffuser showed equal or superior ventilation and thermal environment performance compared to a pan-type diffuser.