Determination of Maintenance Period Considering Reliability Function and Mission Reliability of Electromagnetic Valves of EMU Doors Considering Air Leakage Failure (전동차 출입문 전자변 누기고장의 신뢰도 함수와 임무 신뢰도를 고려한 정비 주기 결정)

  • Park, Heuiseop;Koo, Jeongseo;Kim, Gildong
    • Journal of the Korean Society for Railway
    • /
    • v.20 no.5
    • /
    • pp.569-576
    • /
    • 2017
  • The electromagnetic valve of pneumatic doors of EMUs has a high failure rate due to air leakage because it supplies air on and off to operate the doors repeatedly. The electromagnetic valve is a very important safety component for which a very high reliability is required because failure makes it impossible to operate the passenger cars. However, domestic urban railway operators maintain electronic valves of the EMU door under a fixed cycle with a spare period according to the full overhaul cycle of the EMU. An improvement of the current maintenance cycle was suggested based on the reliability function and mission reliability. Using the statistical program MINITAB for the operational data of EMU line 6, we analyzed the characteristics of the fault distribution and derived the shape and scale parameters of the reliability function. If we limit the specific reliability probability to under a certain failure rate and calculate its statistical parameters, we can calculate the allowable inspection period with mission reliability. Through this study, we suggested a maintenance period based on RCM (reliability centered-maintenance) to improve the reliability of electromagnetic valves from 68% to 95%.