• Title/Summary/Keyword: A Photovoltaic System

Search Result 1,629, Processing Time 0.034 seconds

Normal Operation Characteristics of 30kW Scale CVCF Inverter-Based Micro-grid System (30kW급 CVCF 인버터 기반의 Micro-grid의 정상상태 운용특성에 관한 연구)

  • Ferreira, Marito;Lee, Hu-Dong;Tae, Dong-Hyun;Rho, Dae-Seok
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.6
    • /
    • pp.662-671
    • /
    • 2020
  • Recently, for the purposes of reducing carbon dioxide(CO2) emissions in the island area, countermeasures to decrease the operation rate of diesel generator(DG) and to increase one of renewable energy sources(RES) is being studied. In particular, the demonstration and installation of stand-alone micro-grid(MG) system which is composed of DG, RES and energy storage system(ESS) has been implemented in some island areas such as Gapa-do, Gasa-do and Ulleung-do island. However, many power quality(PQ) problems may be occurred due to an intermittent output of RES including photovoltaic(PV) system and wind power(WP) system in a normal operating of constant voltage & constant frequency(CVCF) inverter-based MG system. Therefore, this paper presents a modeling of the 30kW scale MG system using PSCAD/EMTDC, and also implements a 30kW scale CVCF inverter-based MG system as test devices to analyze normal operating characteristics of MG system. From the simulation and test results, it is confirmed that the proposed methods are useful and practical tools to improve PQ problems such as under-voltage, over-voltage and unbalanced load in CVCF inverter-based MG system.

A study on effects and improvements following the amendment of Feed-In Tariff (발전차액 지원제도 변경 이후 영향 및 개선방향에 대한 연구)

  • Jeon, Byung-Kyu;Kim, Bum-Soo
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2008.05a
    • /
    • pp.83-86
    • /
    • 2008
  • 정부는 2006년 8월 기존의 발전차액 지원제도를 개정하여 발전차액 기준가격 지원대상 확대, 적용기간의 15년 단일화, 수력, 바이오에너지는 고정요금과 변동요금 중에서 선택할 수 있는 선택권 부여, 기술발전에 따라 태양광, 풍력, 연료전지는2-3년간의 유예기간 이후 매년 감소율을 적용하여 기준가격을 낮추는 등 많은 제도개선 내용을 반영하였다. 2006년 10월부터 개정된 발전차액 지원제도가 시행된 이후 태양광, 풍력의 신규진입이 대폭 증가하였고 수력, LFG, 바이오가스는 대부분 변동요금을 신청하였으며 2007년 집행된 신재생에너지 발전차액 기반기금의 55% 이상이 태양광발전에 지급되는 편중현상의 영향이 나타났다. 따라서 변동요금 설계시보다 SMP 평균이 22원 이상 높아져 변동요금의 재설계, 태양광 발전의 기반기금규모가 55% 이상을 점유하고 있으며 향후 더욱 심화될 예정이므로 특정전원의 기반기금 점유비중 제한 및 최근 수년간 준공된 신재생에너지의 운영실적을 분석하고 법적요건을 상세히 검토하여 투자비, 운영비, 이용률등을 재조정하여 기준가격을 합리적으로 개정하여 제2의 신재생에너지 도약기를 마련해야 할 것이다.

  • PDF

A comparative study on the characteristics of the dye-sensitized solar cell with different methods of manufacturing the counter electrode (상대전극 제작 방식에 따른 염료감응형 태양전지 특성 비교 연구)

  • Son, Min-Kyu;Seo, Hyun-Woong;Shin, In-Young;Kim, Jin-Kyoung;Hong, Ji-Tae;Chae, Won-Yong;Kim, Hee-Je
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.1338_1339
    • /
    • 2009
  • Dye-sensitized solar cell (DSC) consists of photo electrode, counter electrode and electrolyte. Photo electrode has titanium oxide layer with dye molecule to create electrons. And counter electrode is made of one layer that has catalytic ability for redox system such as the iodide/triiodide couple. Most DSC researchers use platinum as catalyst on counter electrode because platinum has good catalytic ability and conductivity. Platinum is doped on fluorine-doped tin oxide glass with different methods such as sputtering method, electrochemical method and so on. In this paper, we deposit platinum on counter electrode glass with two methods. One is the radio frequency (RF) sputtering method and the other is the chemical method with heating treatment. Finally, we compare the photovoltaic characteristics of DSCs that are assembled using two different counter electrodes.

  • PDF

Properties of ZnO:Al thin film on variation of substrate temperature for display application

  • Keum, M.J.;Kim, H.W.;Cho, B.J.;Son, I.H.;Choi, M.G.;Lee, W.J.;Jang, K.W.;Kim, K.H.
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2005.07b
    • /
    • pp.1474-1476
    • /
    • 2005
  • ZnO:Al(AZO) has been investigated for the photovoltaic cell or TCO(Transparent Conductive Oxide) of the display, because it has good electrical and optical properties. In this study, the ZnO:Al(AZO) thin film prepared on variation of substrate temperature by FTS(Facing Targets Sputtering) system. In case of TCO, because resistivity and roughness values affect the lighting of the OLED, their factors are very important. Therefore, in this paper, the electrical and optical properties of the AZO thin film were investigated with the deposition conditions and its roughness was investigated on variation of the substrate temperature. In results, AZO thin film deposited with the transmittance over 80% and the resistivity was reduced from $1.36{\times}10^{-3}$ [O-cm] to $4{\times}10^{-4}$ [O-cm] with increasing the substrate temperature from R.T to $200[^{\circ}C]$. Especially, we could obtain the resistivity $4{\times}10^{-4}$ [O-cm] of AZO thin film prepared at working pressure 1[mTorr], input current 0.4[A] and substrate temperature $200[^{\circ}C]$.

  • PDF

Active Frequency Drift Positive Feedback Method for Anti-islanding applied Digital Phase-Locked-Loop (Digital PLL을 이용한 Active Frequency Drift Positive Feedback에 관한 연구)

  • Lee, K.O.;Choi, J.Y.;Choy, I.;Jung, Y.S.;Yu, G.Y.;Song, S.H.
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2007.11a
    • /
    • pp.250-254
    • /
    • 2007
  • As photovoltaic(PV) power generation systems become more common, it will be necessary to investigate islanding detection method for PV systems. Islanding of PV systems can cause a variety of problems and must be prevented. However, if the real and reactive powers of the load and PV system are closely matched, islanding detection by passive methods becomes difficult. Also, most active methods lose effectiveness when there are several PV systems feeding the same island. The active frequency drift positive feedback method(AFDPF) enables islanding detection by forcing the frequency of the voltage in the island to drift up or down. In this paper the research for the minimum value of chopping fraction gain applied digital phase-locked-loop (DPLL) to AFDPF considering output power quality and islanding prevention performance are performed by simulation and experiment according to IEEE Std 929-2000 islanding test.

  • PDF

A Study on the Remote Control of Photovoltaic/Solar Heating System according to Seasonal and Regional (계절 및 지역적 특성을 고려한 태양광발전 태양열시스템의 원격제어에 관한 연구)

  • Yoon H.S.;Kang B.B.;Lim J.Y.;Yoon P.H.;Cha I.S.
    • Proceedings of the KIPE Conference
    • /
    • 2003.07b
    • /
    • pp.938-941
    • /
    • 2003
  • 본 시스템은 나주 생물자원산업화센터에 설치된 태양광 및 태양열 시스템에 대한 운전결과특성으로써 특용작물배양의 전원 및 온수공급을 위한 것이다 태양광발전은 10kWP이고, 태양열시스템은 500l 로 구성되어 있다. 태양광발전시스템의 인버터는 10kW급 계통연계형으로써 상용전원과 연계해서 사용할 수 있도록 하였으며 태양열시스템은 생물자원산업화센터의 실험용 급탕으로 사용된다. 본 논문에서는 태양광발전과 태양열시스템이 설치된 생물자원산업화센터에 상주 근무인원을 대체하기 위해서 원격 모니터링 시스템을 구성하였고, 모니터링에 의해 축적된 데이터를 통해 그 특성을 비교하고자 한다.

  • PDF

Anti-Reflection Thin Film For Photoelectric Conversion Efficiency Enhanced of Dye-Sensitized Solar Cells (염료감응형 태양전지의 광전변환효율 향상을 위한 무반사 박막)

  • Jung, Haeng-Yun;Ki, Hyun-Chul;Hong, Kyung-Jin
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.29 no.12
    • /
    • pp.814-818
    • /
    • 2016
  • DSSCs (dye-sensitized solar cells) based on $TiO_2/SiO_2$ multi layer AR (anti-reflection) coating on the outer glass FTO (fluorine-doped tin oxide) substrate are investigated. We have coated an AR layer on the surface of a DSSCs device by using an IAD (ion beam-assisted deposition) system and investigated the effects of the AR layer by measuring photovoltaic performance. Compared to the pure FTO substrate, the multi layer AR coating increased the total transmittance from 67.4 to 72.9% at 530 nm of wavelength. The main enhancement of solar conversion efficiency is attributed to the reduction of light reflection at the FTO substrate surface. This leads to the increase of Jsc and the efficiency improvement of DSSCs.

Research of DC-DC Converter for Ocean Buoy (해상용 브이에 적합한 DC-DC 컨버터 연구)

  • Oh, Jin-Seok
    • Journal of Navigation and Port Research
    • /
    • v.31 no.10
    • /
    • pp.839-844
    • /
    • 2007
  • This paper describes the performance of DC-DC converters for buoy such as buck, boost, and buck-boost. The operating characteristic and charging efficiency with battery, which has a considerable properties about converters with PV(photovoltaic) system, is analyzed in this paper. It is performed by using the MPPT(Maximum Power Point Tracker) algorithm The basic equations of switching operation for converter are described, and the equations are analyzed with according to switch state. Whereas this analysis is directed toward the selection of converter for buoy, it also provides the insight into the behaviour of converter and performance of the proposed algorithm Finally, the suitable DC-DC converter is proposed for buoy, and the characteristic experiment is performed with the buck converter.

An Experimental Study of Performance Improvement of Air Type PV/T Collector Units (실험에 의한 공기식 태양광·열 복합 유닛의 성능 비교)

  • Kim, Jin-Hee;Yang, Yeon-Won;Kim, Jun-Tae
    • KIEAE Journal
    • /
    • v.7 no.6
    • /
    • pp.17-22
    • /
    • 2007
  • The integration of PV modules into building facades or roof could raise their temperature that results in the reduction of PV system's electrical power generation. Hot air can be extracted from the space between PV modules and building envelope, and used for heating in buildings. The extraction of hot air from the space will enhance the performance of BIPV systems. The solar collector utilizing these two aspects is called PV/T(photovoltaic/thermal) solar collector. This paper compares the experimental performance of two different types of air type PV/T collector units: the base case of a collector unit with 10cm gap for forced ventilation and the other unit with copper pin attached to PV module to enhance its thermal performance. The experimental results shows that the base case unit had the overall efficiency of 41.9% and the improved unit with copper pin attached to PV module had 50.1% efficiency. For these air type PV/T units, the forced ventilation of the air space improved the electrical performance as well as the thermal performance.

Active Frequency Drift Positive Feedback Method for Anti-islanding (단독운전검출을 위한 능동적 주파수 변화 정궤환기법)

  • So, J.H.;Jung, Y.S.;Yu, G.J.;Yu, B.G.;Lee, K.O.;Choi, J.Y.
    • Proceedings of the KIEE Conference
    • /
    • 2005.07b
    • /
    • pp.1684-1686
    • /
    • 2005
  • As photovoltaic(PV) power generation systems become more common, it will be necessary to investigate islanding detection method for PV systems. Islanding of PV systems can cause a variety of problems and must be prevented. However, if the real and reactive power of load and PV system are closely matched, islanding detection by passive methods becomes difficult. Also, most active methods lose effectiveness when there are several PV systems feeding the same island. The active frequency drift positive feedback method(AFDPF) enables islanding detection by forcing the frequency of the voltage in the island to drift up or down. In this paper the research for the minimum value of chopping fraction gain applied digital phase-locked-loop(DPLL) to AFDPF considering output power quality and islanding prevention performance are performed by simulation and experiment in IEEE Std 929-2000 islanding test.

  • PDF