• Title/Summary/Keyword: A/D board

Search Result 786, Processing Time 0.026 seconds

IIR Filter Design of HRTF for Implementation of 3D Sound (입체음향 구현을 위한 머리전달함수의 IIR필터 설계)

  • Kim Pan-Gon;Park Jang-Sik;Kim Hyun-Tae
    • Proceedings of the Korea Contents Association Conference
    • /
    • 2005.05a
    • /
    • pp.341-345
    • /
    • 2005
  • In this paper, we propose an algorithm for the approximation of FIR filters by IIR filters. The algorithm is based on a concept of the balanced model reduction. Head-related transfer functions(HRTFs) of dummy-head are approximated by 32-order IIR filters. The binaural sounds using the approximated HRTFs are reproduced by headphone, and serves as a cue of sound image localization. Experiment of sound image are carried out for 10 participants with computer simulation and DSP board respectively. The results of the experiments show that the localization using the approximated HRTFs by IIR filters is the same accuracy as the case of FIR filters that simulate the HRTFs.

  • PDF

A Study on Optimal Hydrophone Arrangement for The Direction Finding of High Speed Moving Target in Underwater (수중에서 고속 기동하는 표적의 방위 탐지를 위한 최적의 청음기 배치 연구)

  • Han, Min-Su;Choi, Jae-Yong;Kang, Dong-Seok;Son, Kweon;Lee, Phil-ho
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.20 no.3
    • /
    • pp.369-375
    • /
    • 2017
  • One of good DF(Direction Finding) methods is based on TDOA(Time Difference of Arrival) estimation when finding underwater moving target. For small DF error, high time resolution A/D(Analog-to-digital) conversion board and long baseline are needed. But the result of sea trial about close-range and high speed moving target, spatial correlation coefficient and appeared poor properties below 0.3 when hydrophone arrangement are separated over 6 ${\lambda}$ because of underwater fading channel. And we also find out that the distance between hydrophone should be under 4 ${\lambda}$ apart to take advantage of spatial correlation coefficient gain and performance of DF in underwater moving channel environments.

PlV Measurement of Channel Cavity Flow with Bottom Heat surface of Constant Heat Flux (일정 열유속의 하부 가열면을 갖는 채널캐비티 내부유동의 PIV 계측)

  • 조대환;김진구
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.21 no.4
    • /
    • pp.437-442
    • /
    • 1997
  • An experimental study was carried out in a channel cavity with square heat surface by visual¬ization equipment with Mach - Zehnder interferometer and laser apparatus. The image processing system consists of one commercial image board slit into a personal computer and 2-dimensional sheet light by Argon-Ion Laser with cylindrical lens and flow picture recording system. Instant simultaneous velocity vectors at whole field were measured by 2-D PIV system which adopted two¬frame grey-level cross correlation algorithm. Heat source was uniform heat flux(o.4W/cm$^2$, , O.8W/cm$^2$, 1.2W/cm$^2$). Obtained result showed various flow patterns such as kinetic energy distribution. Severe unsteady flow fluctuation within the cavity are remarkable and sheared mixing layer phenomena are also found at the region where inlet flow is collided with the counter-clockwise rotating main primary vortex. Photographs of Mach ~ Zehnder are also compared in terms of constant heat flux.

  • PDF

Impact of SAPHIR Data Assimilation in the KIAPS Global Numerical Weather Prediction System (KIAPS 전지구 수치예보모델 시스템에서 SAPHIR 자료동화 효과)

  • Lee, Sihye;Chun, Hyoung-Wook;Song, Hyo-Jong
    • Atmosphere
    • /
    • v.28 no.2
    • /
    • pp.141-151
    • /
    • 2018
  • The KIAPS global model and data assimilation system were extended to assimilate brightness temperature from the Sondeur $Atmosph{\acute{e}}rique$ du Profil $d^{\prime}Humidit{\acute{e}}$ Intertropicale par $Radiom{\acute{e}}trie$ (SAPHIR) passive microwave water vapor sounder on board the Megha-Tropiques satellite. Quality control procedures were developed to assess the SAPHIR data quality for assimilating clear-sky observations over the ocean, and to characterize observation biases and errors. In the global cycle, additional assimilation of SAPHIR observation shows globally significant benefits for 1.5% reduction of the humidity root-mean-square difference (RMSD) against European Centre for Medium-Range Weather Forecasts (ECMWF) Integrated Forecast System (IFS) analysis. The positive forecast impacts for the humidity and temperature in the experiment assimilating SAPHIR were predominant at later lead times between 96- and 168-hour. Even though its spatial coverage is confined to lower latitudes of $30^{\circ}S-30^{\circ}N$ and the observable variable is humidity, the assimilation of SAPHIR has a positive impact on the other variables over the mid-latitude domain. Verification showed a 3% reduction of the humidity RMSD with assimilating SAPHIR, and moreover temperature, zonal wind and surface pressure RMSDs were reduced up to 3%, 5% and 7% near the tropical and mid-latitude regions, respectively.

A Study on Noise Control and Verification of High Pressure Steam System Using Experimental Method (실험적 방법을 이용한 고압증기 시스템의 방음설계 및 검증에 관한 연구)

  • Seok, H.I.;Lee, D.K.;Jeong, T.S.;Heo, J.H.
    • Special Issue of the Society of Naval Architects of Korea
    • /
    • 2011.09a
    • /
    • pp.112-116
    • /
    • 2011
  • The noise analysis is usually carried out in the early structure design stage for the main areas in a vessel such as an accommodation, an engine room, HVAC System and etc. If the analysis results are higher than the noise limits based on guideline, appropriate countermeasures are established to reduce noise levels and applied to the vessel. But excessive noise induced the main or auxiliary equipment and high pressure steam system is very difficult to check in the initial design stage, and local noise problems frequently appear in actual vessels. This paper deals with excessive noise of the engine control room on LNG carrier. It includes the cause analysis of excessive noise, the countermeasure, and verification. Also, it proves suitability of the countermeasure through the on-board test.

  • PDF

Optimum Design for Frame Bracket of Electrical Panels for Improved Fatigue Strength (함정용 배전반의 피로강도 향상을 위한 프레임 브래킷의 최적설계)

  • Kim, Myung-Hyun;Choi, Jae-Young;Kang, Sung-Won;Chung, Ji-Young
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.43 no.2 s.146
    • /
    • pp.206-212
    • /
    • 2006
  • Structural reliability of electrical panels installed in naval vessels is of critical importance from structural performance viewpoint. The electrical panels may be exposed to vibration and fatigue loadings from internal and external sources as well as wave loadings which result into a crack and fracture due to the decrease of fatigue strength. It is also well known that welded joints including brackets within steel structures .such as vessels and bridges are vulnerable against such repeated loadings. This study introduces a preliminary result of the optimized shape of frame bracket consisting of electrical panels in navel vessels against fatigue loading and their fatigue life at brackets of electrical panels by means of hot spot stress and structural stress methods.

EMI Prediction of Slew-Rate Controlled I/O Buffers by Full-Wave and Circuit Co-Simulation

  • Kim, Namkyoung;Hwang, Jisoo;Kim, SoYoung
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.14 no.4
    • /
    • pp.471-477
    • /
    • 2014
  • In this paper, a modeling and co-simulation methodology is proposed to predict the radiated electromagnetic interference (EMI) from on-chip switching I/O buffers. The output waveforms of I/O buffers are simulated including the on-chip I/O buffer circuit and the RC extracted on-chip interconnect netlist, package, and printed circuit board (PCB). In order to accurately estimate the EMI, a full-wave 3D simulation is performed including the measurement environment. The simulation results are compared with near-field electromagnetic scan results and far-field measurements from an anechoic chamber, and the sources of emission peaks were analyzed. For accurate far-field EMI simulation, PCB power trace models considering IC switching current paths and external power cable models must be considered for accurate EMI prediction. With the proposed EMI simulation model and flow, the electromagnetic compatibility can be tested even before the IC is fabricated.

Composite Discharge Capacity Analysis of Vertical Drain Installed in Ground (연직배수재가 타설된 지반의 복합통수능 해석)

  • Kim, Chang-Young;Kwak, No-Kyung;Lee, Song
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2008.10a
    • /
    • pp.1167-1174
    • /
    • 2008
  • Vertical drain method, which is one of the soft ground improvement methods, shorten s drain path to accelerate consolidation process and is applied in many sites. At a recent, composite discharge capacity experiment that analyze discharge amount by consolidation behavior with overburden pressure of soft ground in laboratory, simulates similarly with actuality. Geotechnical engineering problems such a s soft ground improvement are solved by numerical analysis by development of computer and numerical analysis techniques. Numerical analysis does that result is contrary by user's inexperience for choice of constitution model and application of analysis method. Therefore, this thesis experiments on composite discharge capacity test and study discharge capacity of drain and consolidation behavior of soft ground installed prefabricated vertical drain boards. Also, This thesis studied reasonable input parameters and constitution model by compare results of composite discharge capacity test and numerical analysis using PLAXIS that is 2D finial element numerical analysis program.

  • PDF

State-of-the-Art mmWave Antenna Packaging Methodologies

  • Hong, Wonbin
    • The Proceeding of the Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.24 no.2
    • /
    • pp.15-22
    • /
    • 2013
  • Low-Temperature-cofired ceramics (LTCC) antenna packages have been extensively researched and utilized in recent years due to its excellent electrical properties and ease of implementing dense package integration topologies. This paper introduces some of the key research and development activities using LTCC packaging solutions for 60 GHz antennas at Samsung Electronics [1]. The LTCC 60 GHz antenna element topology is presented and its measured results are illustrated. However, despite its excellent performance, the high cost issues incurred with LTCC at millimeter wave (mmWave) frequencies for antenna packages remains one of the key impediments to mass market commercialization of mmWave antennas. To address this matter, for the first time to the author's best knowledge this paper alleviates the high cost of mmWave antenna packaging by devising a novel, broadband antenna package that is wholly based on low-cost, high volume FR4 Printed Circuit Board (PCB). The electrical properties of the FR4 substrate are first characterized to examine its feasibility at 60 GHz. Afterwards a compact multi-layer antenna package which exhibits more than 9 GHz measured bandwidth ($S_{11}{\leq}-10$ dB) from 57~66 GHz is devised. The measured normalized far-field radiation patterns and radiation efficiency are also presented and discussed.

Intrusion Sensor Using Fiber-Optic Mach-Zehnder Interferometer (광섬유 마하젠더 간섭계를 이용한 침입자 감지 센서)

  • Park, Hyoung-Jun;Song, Min-Ho
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.26 no.4
    • /
    • pp.255-259
    • /
    • 2006
  • For the intruder detection, a buried fiber-optic sensor based on fiber-optic Mach-Zehnder interferometer is demonstrated. We buried the sensor arm in a styrene board and exerted pressure on it. The pressure-induced deformation speed has almost linear relationship with the output frequencies of the interference signals, and about 4.25 Hz frequency change per 0.01m/s was obtained. Also it has been shown that the amplitude of frequency component increases according to the weight of mass.