• Title/Summary/Keyword: 99mTc

Search Result 1,350, Processing Time 0.023 seconds

The Usefulness of Tc-99m MIBI SPECT in the Localization and the Assessment of Radiotherapy in Non-Small Cell Lung Cancer (비소세포 폐암의 국소화 및 방사선치료 판정에 있어 Tc-99m MIBI SPECT의 유용성)

  • Bom, Hee-Seung;Song, Ho-Chun;Kim, Ji-Yeul;Nam, Taek-Keum;Ahn, Sung-Ja;Chung, Woong-Ki;Nah, Byung-Sik
    • The Korean Journal of Nuclear Medicine
    • /
    • v.28 no.2
    • /
    • pp.186-191
    • /
    • 1994
  • Tc-99m MIBI, a lipophilic cation, was reported as a useful agent for localization of lung cancer. The effect of radiation therapy on the uptake of Tc-99m MIBI in lung cancer, however, was not well evaluated. The aim of the present study was to elucidate the usefulness of Tc-99m MIBI SPECT in the localization and the assessment of radiotherapy in non-small cell lung cancer. Twenty patients(19 males and 1 female, mean age 59, 16 squamous cell ca and 4 adenoca) were studied with Tc-99m MIBI SPECT before radiation therapy. Eleven patients(10 males and 1 female, mean age 59, 8 squamous cell ca and 3 adenoca) were repeated the study 1 month after the completion of radiation therapy(mean dose 6453cGy). All patients showed positive uptakes of Tc-99m MIBI in their tumors. One patient showed a hot uptake in atelectatic area. There was no difference of Tc-99m MIBI uptakes between squamous cell ca and adenoca either on planar or tomographic images. Tc-99m MIBI uptake ratios of squamous cell ca and adenoca were $1.50{\pm}0.16$ and $1.45{\pm}0.15$ on planar images, and $2.73{\pm}0.46$ and $2.54{\pm}0.37$ on tomographic images, respectively. The concordance between radiological change(chest x-ray and CT) and change of Tc-99m MIBI uptakes was 9/11 (81.8% ). In conclusion, Tc-99m MIBI SPECT was useful in the localization of tumor and the assessment of radiation therapy in non-small cell lung cancer.

  • PDF

[ $^{99m}Tc$ ] Generator Safety Simulation Based on GEANT4 (GEANT4를 이용한 $^{99m}Tc$ Generator 안전성 시뮬레이션)

  • Kang, Sang-Koo;Han, Dong-Hyun;Kim, Chong-Yeal
    • Progress in Medical Physics
    • /
    • v.19 no.1
    • /
    • pp.1-8
    • /
    • 2008
  • Technisium $(^{99m}Tc)$ is one of the most widely used radioactive isotopes for diagnosis in nuclear medicine. In general, technisium is produced inside the so called $^{99m}Tc$ generator which is usually made out of lead to shield relatively high energy radiation from $^{99}Mo$ and its daughter nuclide $^{99m}Tc$. In this paper, a GEANT4 simulation is carried out to test the safety of the $^{99m}Tc$ generator, taking the Daiichi product with radioactivity of 500 mCi as an example. According to the domestic regulation on radiation safety, the dose at 10 cm and 100 cm away from the surface of shielding container should not exceed 2.0 mSv/h and 0.02 mSv/h, respectively. The simulated dose turned out to be less than the limit, satisfying the domestic regulation.

  • PDF

Detection for Residual Thyroid Tissue and Metastatic Lesion after Total Thyroidectomy in Patients with Differentiated Thyroid Cancer: Comparison between Tc-99m Pertechnetate Sean and High Dose I-131 Therapy Sean (분화 갑상선암 환자의 수술후 잔여갑상선조직 및 전이병소의 진단: Tc-99m Pertechnetate 스캔과 고용량 옥소 치료 후 I-131 스캔의 비교)

  • Lee, Joo-Ryung;Ahn, Byeong-Cheol;Jeong, Shin-Young;Lee, Jae-Tae;Lee, Kyu-Bo
    • The Korean Journal of Nuclear Medicine
    • /
    • v.37 no.2
    • /
    • pp.120-127
    • /
    • 2003
  • Purpose: To evaluate diagnostic sensitivity of nuclear imaging in the detection of residual thyroid tissue and metastatic lesion, we have compared neck scintigrams with Tc-99m pertechnetate (Tc-99m scan) and high dose I-131 iodide (I-131 scan) in patients with differentiated thyroid cancer. Subjects and Methods: One hundred thirty-five thyroidectomized patients for differentiated thyroid cancer were enrolled in this study. Twenty-three had a previous history of radioiodine therapy. Planar and pin-hole images of anterior neck with Tc-99m were acquired at 20 minutes after injection, followed by I-131 scan three days after high-dose radioiodine therapy within 7 days interval. Patients were asked to discontinue thyroid hormone replacement more than 4 weeks. Results: All subjects were in hypothyroid state. Seventy out of 135 patients (51.9%) showed concordant findings between Tc-99m and I-131 scans. I-131 scan showed higher number of uptake foci in all of 65 patients showing discordant finding. Tc-99m scan showed no thyroid bed uptake in 34 patients, whereas 23 of them (67.6%) showed bed uptake in I-131 scan. Tc-99m scan did not show any uptake in thyroid bed in 11 of 112 patients without previous history of radioiodine therapy, but 9 of them showed bed uptake in I-131 scan. Tc-99m scan showed no bed uptake in all of the 23 patients with previous history of radioiodine therapy, in contrast 14 of them (60.9%) showed bed uptake in I-131 scan. Conclusion: These results suggest that Tc-99m scan has poor detectability for residual thyroid tissue or metastatic lesion in thyroidectomized differentiated thyroid cancer patients, compared to high dose I-131 therapy scan. Tc-99m scan could not detect any remnant tissue or metastatic lesion in patients with previous history of radioiodine treatment, especially.

Usefulness and Comparison of $^{201}TI$-chloride, $^{99}mTc$-MIBI, $^{99}mTc(V)$-DMSA Single Photon Emission Computed Tomography in Distinguishing Lung Cancer from Benign Lesion (폐암과 양성질환의 감별에 $^{201}TI$-chloride, $^{99}mTc$-MIBI, $^{99}mTc(V)$-DMSA 단일광자전산화단층촬영술의 비교 및 가치)

  • Kim, Chang Ho;Chae, Sang Cheol;Park, Jae Yong;Jung, Tae Hoon;Ahn, Byeong Cheol;Lee, Jae Tae
    • Tuberculosis and Respiratory Diseases
    • /
    • v.43 no.5
    • /
    • pp.720-727
    • /
    • 1996
  • Objectives: $^{201}TI$ - chloride, $^{99m}Tc$ - MIBI, $^{99m}Tc$(V) - DMSA SPECT has been used in distinguishing lung cancer from benign lesion. To compare the diagnostic efficacy of SPECT with these tumor - seeking agents, we perfonned three consecutive SPECT using $^{201}TI$, $^{99m}Tc$ - MIBI, $^{99m}Tc$(V) - DMSA in same subjects with a solitary pulmonary lesion. Methods: SPECT was carried out at 10min and 3hr for $^{201}TI$ after injection of 20mCi, and 2hr for $^{99m}Tc$ - MIBI and $^{99m}Tc$(V) - DMSA after injection of 20mCi, respectively, in 37 patients with a solitary pulmonary lesion(27 lung cancer and 10 benign diseases). In patients showing visual uptake on lesion site, we obtained the lesion - to - background(target lesion/contralateral normal lung) uptake ratio from transverse slice for each radionuclide and also calculated the retention index for $^{201}TI$. Results: The diagnostic sensitivity of $^{201}TI$, $^{99m}Tc$ - MIBI and $^{99m}Tc$(V) - DMSA SPECT to lung cancer was 100%, 96% and 73%, and the specificity was 40%, 70% and 70%, respectively. The low specificities for these agents were mainly due to high positive uptake in patients with active pulmonary tuberculosis. There were no significant differences in uptake ratios and retention index between malignant and benign lesions, and among the histologic types of lung cancer. Conclusion : $^{201}TI$ and $^{99m}Tc$ - MIBI showed higher sensitivity than $^{99m}Tc$(V) - DMSA for detecting lung cancer, but was of limited usefulness in distinguishing lung cancer from benign lesion due to low specificity, especially in area with a high prevalence of active pulmonary tuberculosis.

  • PDF

Kit Preparation and Biodistribution of $Bz-MAG_3$ (benzoylmercaptoacetylglycylglycylglycine) for Renal Imaging (신장기능영상용 방사성의 약품 $Bz-MAG_3$(Benzoylmercaptoacetylglycylglycylglycine) 의 키트화 및 체내분포)

  • Kim, Young-Ju;Jeong, Jae-Min;Cho, Jung-Hyuk;Chang, Young-Soo;Lee, Dong-Soo;Chung, June-Key;Lee, Myung-Chul;Koh, Chang-Soon
    • The Korean Journal of Nuclear Medicine
    • /
    • v.30 no.3
    • /
    • pp.367-371
    • /
    • 1996
  • The $MAG_3$ is a tubular excreting radiopharmaceutical for renal image. We synthesized benzoyl $MAG_3\;(Bz-MAG_3)$ and made a kit for labeling with $^{99m}Tc$. We checked the labeling efficieny of $^{99m}Tc$ labeled $MAG_3$ and biodistribution. Labeling efficieny was checked by TLC-SG (acetonitrile/$H_2O$=2/1). After injecting of 1 mCi of $^{99m}Tc-MAG_3$ to ICR-mice, $T_{max}(min),\;T_{1/2}(min)$ were obtained in the renogram. Sequential images (30sec, 2min, 5min, 10min, 15min, 20min) of $^{99m}Tc-MAG_3$ were compared with those of commercial $^{99m}Tc$-DTPA (Du Pont Merck Pharmaceutical Co.) kit. 1) The $R_f$ value of synthesized $^{99m}Tc-MAG_3$ was 0.78 and labeling efficiency was $97.5{\pm}1.9%$ (n=10). 2) The dynamic images of the $^{99m}Tc-MAG_3$ were better than those of the $^{99m}Tc$-DTPA. 3) The $T_{max}(min.)$ and $T_{1/2}(min.)$ of $^{99m}Tc-MAG_3$ (n=10) were $1.5{\pm}0.5$ (left), $1.4{\pm}0.4$ (right), and $4.3{\pm}1.4$ (left), $4.8{\pm}2.0$ (right), respectively. The $T_{max}(min.)$ and $T_{1/2}(min.)$ of $^{99m}Tc$-DTPA (n=7) were $2.7{\pm}1.6$ (left), $2.7{\pm}1.6$ (right), and $3.8{\pm}1.7$ (left), $4.5{\pm}2.7$ (right), respectively. The quaility of image and labeling efficiency of the synthesized $Bz-MAG_3$ kit were excellent, that it was supposed to be used in routine clinical work.

  • PDF

Synthesis and in vitro evaluation of 99mTc-labeled tetraiodothyroacetic acid for tumor angiogenesis imaging

  • Kim, Hyunjung;Koo, Hyun-Jung;Choe, Yearn Seong
    • Journal of Radiopharmaceuticals and Molecular Probes
    • /
    • v.6 no.1
    • /
    • pp.3-9
    • /
    • 2020
  • Tetraiodothyroacetic acid (tetrac) is a derivative of thyroid hormone T4 and causes anti-angiogenesis by blocking T4 binding to integrin αvβ3. In this study, we synthesized [99mTc]Tc-Cys-Asp-Gly(CDG)-tetrac and evaluated it in vitro as a tumor angiogenesis imaging ligand. The CDG was conjugated to tetrac as a chelator for technetium-99m labeling. The cold vial containing CDG-tetrac, sodium glucoheptonate, and reducing agent was completed under nitrogen-filled atmospheric glove bag. [99mTc]Tc-CDG-tetrac was synthesized in quantitative yield by heating the cold vial with [99mTc]TcO4- at 100℃ for 30 min. In vitro serum stability of [99mTc]Tc-CDG-tetrac was measured by incubating the radioligand in 50% fetal bovine serum at 37℃ and analyzing the incubation mixture by radio-TLC, which showed high stability over 6 h (≥ 98%). Cell binding study was carried out by incubating [99mTc]Tc-CDG-tetrac with human umbilical vein endothelial (HUVE) cells at 37℃ for 6 h. The cell binding of the radioligand increased from 100% at 0.5 h to 293.7% at 6 h in a time-dependent manner. For blocking study, the cells were incubated with the radioligand in the presence of either tetrac (20 μM) or cRGDyK (20 μM) at 37℃ for 4 h. The results demonstrated that the cell binding of the radioligand was inhibited by tetrac (19.1%) or cRGDyK (35.6%), indicating specific binding of the radioligand to integrin αvβ3. Thus, this study suggests that [99mTc]Tc-CDG-tetrac may be a potential radioligand for tumor angiogenesis imaging.

Effect of Multidrug Resistance Gene-1 (mdr1) Overexpression on In-Vitro Uptake of $^{99m}Tc$-sestaMIBl in Murine L1210 Leukemia Cells (백혈병 세포에서 Multidrug Resistance Gene-1 (mdr1)의 과발현이 $^{99m}Tc$-sestaMIBl 섭취에 미치는 영향)

  • Chun, Kyung-Ah;Lee, Jae-Tae;Lee, Sang-Woo;Kang, Do-Young;Sohn, Sang-Kyun;Lee, Jong-Kee;Chung, June-Key;Jun, Soo-Han;Lee, Kyu-Bo
    • The Korean Journal of Nuclear Medicine
    • /
    • v.33 no.2
    • /
    • pp.152-162
    • /
    • 1999
  • Purpose: To determine whether $^{99m}Tc$-MIBI is recognized by the multidrug resistant P-glycoprotein (Pgp), we have measured quantitatively $^{99m}Tc$-MIBI uptake in cancer cells. The effects of various Pgp reversing agents on cellular $^{99m}Tc$-MIBI uptake were also investigated in the presence of multidrug resistance gene-1 (mdr1 gene) overexpression. Materials and Methods: We measured percentage uptake of $^{99m}Tc$-MIBI at different incubation temperatures both in mdr1 positive and negative cells. The effects of verapamil, cyclosporin, and dipyridamole on cellular uptake of $^{99m}Tc$-MIBI were also evaluated with or without overex-pression of mdr1 gene in cultured murine leukemia Ll210 cells. Results: The mdr1 gene expressing cell lines were effectively induced in in vitro with continuous application of low-dose adriamycin or vincristine. Cellular uptake of $^{99m}Tc$-MIBI was higher in mdr1 negative Ll210 cells than those of mdr1 positive cells, and higher when incubated in $37^{\circ}C$ than $4^{\circ}C$. In the presence of verapamil, cyclosporin or dipyridamole, $^{99m}Tc$-MIBI uptake was increased upto 604% in mdr1 positive cells. Conclusion: Cellular uptake of $^{99m}Tc$-MIBI is lower in leukemia cells over-expressing mdr1 gene, and MBR-reversing agents increase cellular uptake. These results suggest that $^{99m}Tc$-MIBI can be used for characterizing Pgp expression and developing MDR-reversing agents in vitro.

  • PDF

Thallium-201 Scan in Bone and Softtissue Sarcoma - Comparison with Tc-99m-MIBI and Tc-99m-MDP Scan - (악성 골 및 연부조직 종양에서 Tl-201 SCAN의 진단적 효능 - Tc-99m-MIBI 및 Tc-99m-MDP scan과의 비교 -)

  • Shin, Duk-Seop;Cho, Ihn-Ho;Ahn, Jong-Chul;Ahn, Myun-Hwan;Lee, Sang-Ho
    • The Journal of the Korean bone and joint tumor society
    • /
    • v.2 no.1
    • /
    • pp.1-7
    • /
    • 1996
  • PURPOSE : The purpose of this study is to know the ability of detecting malignant tumor tissue by Tl-201 scan, and to compare with that of Tc-99m-MIBI and Tc-99m-MDP scan. MATERIAL AND METHODS : Between February 1994 and December 1995,38 unselected patients with various bone pathologies were studied prospectively. Eighteen had malignant bone and soft tissue pathologies, while twenty had benign. All patients were studied with Tl-201, Tc-99mMIBI and Tc-99m-MDP scan prior to surgical biopsy. PICKER Prism 2000 gamma camera with high resolution parallel hole collimator was used for scanning. To avoid the interaction of isotope, the early(30min.) and delayed phase(3hrs.) of Tl-20l scan was performed first and Tc-99m-MIBI scan was performed after 30 minutes, and then Tc-99m-MDP scan 48 hours later. The scan images were visually evaluated by a blinded nuclear medicine physician. We could find true positive, true negative, false positive and false negative by the comparison of results with those of biopsy. We calculated positive and negative predictive value(%), sensitivity(%), specificity(%) and diagnostic accuracy(%) of each scan. RESULT : The results of each scan were 85.7, 100, 100, 85, 92.1% in Tl-201, 81, 94.1, 94.4, 80, 86.8% in Tc-99m-MIBI and 50, 66.7, 88.9, 20, 52.6% in Tc-99m-MDP scan. As a conclusion, Tl-201 scan was the most specific and accurate method for detecting malignant tumor tissue. Tc-99m-MIBI scan was also good for malignant tumor searching. CONCLUSION : With our results, we can use Tl-201 scan to differentiate benign from malignant tumor, and to evaluate the response of preoperative chemotherapy or radiotherapy, and to determine the residual tumor or local recurrence. For the better result, we need to have a more detail information about false positive cases and a more objective and quantitative reading technique.

  • PDF

A study of 99mTc-sestamibi labeling condition using radio-chromatography

  • Moon, Sung-Hyun;Lee, Yun-Sang;Lee, Dong Soo;Chung, June-Key;Jeong, Jae Min
    • Journal of Radiopharmaceuticals and Molecular Probes
    • /
    • v.3 no.1
    • /
    • pp.38-43
    • /
    • 2017
  • Tc-99m labeled sestamibi ($^{99m}Tc$-MIBI) is one of most widely used radiopharmaceuticals for myocardial SPECT imaging. Radiolabeling of $^{99m}Tc$-MIBI is recommended by heating in $100^{\circ}C$ water bath for 15 min. However, the water bath might be a source of contamination. Thus, if radiolabeling of $^{99m}Tc$-sestamibi can be performed at room temperature, then it would be more convenient to use in clinical application. In this study, we performed the radiolabeling of $^{99m}Tc$-MIBI in different temperature conditions or using different instruments to find out the efficient labeling condition. We studied the $^{99m}Tc$-MIBI labeling at room temperature or $100^{\circ}C$ heating block, and checked the labelling yields every 1 min for 10 min using radio-TLC with 2 different eluents-saline and acetone. From the experiment, we confirmed that the $^{99m}Tc$-MIBI can be labeled over 90% yield but not completed at room temperature. However, the $^{99m}Tc$-MIBI labeling was completed when it was performed in the $100^{\circ}C$ heating block. Finally, we proved that heating is essential for complete $^{99m}Tc$-MIBI labelling, furthermore using heating block is also possible instead of water bath.

Effect of the Bifunctional Chelate on the Biodistribution of 99mTc-labeled Cyclic RGD Peptide

  • Lee, Dong-Eun;Choi, Kang-Hyuk
    • Journal of Radiation Industry
    • /
    • v.12 no.4
    • /
    • pp.355-363
    • /
    • 2018
  • A novel $N_3S_1$ chelate, Pro-Lys-Cys (PKC) to cyclic RGD to radiolabel with $^{99m}Tc$ was conjugated in an effort to decrease the high intestinal accumulation observed for $^{99m}Tc$-labeled PGC-RGD. The target specificity of the resulting PKC-RGD was similar to that of PGC-RGD as determined by a cell binding assay and a competition binding assay. The $^{99m}Tc$ radiolabeling of PKC-RGD resulted in radiochemical yields of 98% under mild conditions at high specific activities. Biodistribution data in normal mice clearly showed a significant decrease in intestinal uptake at 2 h postinjection for the $^{99m}Tc-PKC-c$ (RGDyK) compared to the $^{99m}Tc-GC-c$ (RGDyK) (from $19.65%ID{\cdot}g^{-1}$ to $7.31%ID{\cdot}g^{-1}$ for the GI tract). The $^{99m}Tc-PKC-c$ (RGDyK) biodistribution was also shown by a higher retention of radioactivity in the whole body, but with kidney accumulation over 8-fold higher than observed with $^{99m}Tc-PGC-c$ (RGDyK) at 2 h ($12.62%ID{\cdot}g^{-1}$ for PKC-RGD and $1.54%ID{\cdot}g^{-1}$ for PGC-RGD, respectively). These results show that the biodistribution may be altered especially concerning lipophilicity resulting in renal rather than hepatobiliary excretion. This comparative study made it possible to explore the effects of lipophilicity on the biodistribution of $^{99m}Tc$-labeled c (RGDyK) through the use of different tripeptide $N_3S_1$ chelators. Therefore, $^{99m}Tc-PKC-c$ (RGDyK) may be an attractive alternative for the in vivo imaging of integrin receptors.