• Title/Summary/Keyword: 99

검색결과 25,838건 처리시간 0.041초

Anti-inflammatory effects of Chamaecyparis obtusa (Siebold & Zucc.) Endl. Leaf Fractions (편백(Chamaecyparis obtusa (Siebold & Zucc.) Endl.) 잎 분획물의 항염증 효과)

  • Yong-Jin Kwon
    • Journal of the Korean Applied Science and Technology
    • /
    • 제40권6호
    • /
    • pp.1268-1277
    • /
    • 2023
  • In this study, to evaluate the possibility of utilizing Chamaecyparis obtusa (Siebold & Zucc.) Endl. (C. obtusa) leaf fractions as anti-inflammatory functional materials, C. obtusa extract extracted with 99% ethanol (CO99EL) was fractionated with hexane (CO99EL-H), chloroform (CO99EL-C), ethyl acetate (CO99EL-E), butanol (CO99EL-B) and distilled water (CO99EL-W). The anti-inflammatory effects of each fraction was performed using lipopolysaccharide (LPS)-induced RAW264.7 mouse macrophages. Cytotoxicity was highest in CO99EL-H and CO99EL-C and lowest in CO99EL-W. Interestingly, LPS-induced iNOS expression and NO production were significantly reduced by CO99EL-H and CO99EL-E, and COX-2 expression was significantly reduced by CO99EL-B and CO99EL-W. In addition, interleukin (IL)-1𝛽, an inflammatory cytokine increased by LPS, was significantly reduced by CO99EL-C, CO99EL-E, CO99EL-B and CO99EL-W, and IL-6 was significantly reduced by CO99EL-B and CO99EL-W. Therefore, the janus kinase (JAK)/signaling transducer and activator of transcription (STAT) signaling pathway activated by LPS was significantly reduced by CO99EL-H and CO99EL-C, and the mitogen-activated protein kinase (MAPK) signaling pathway was slightly reduced by CO99EL-H and CO99EL-C. However, nuclear factor (NF)-𝜅B activity was not reduced by any fractions. Based on the results of this study, it was confirmed that CO99EL fractions have different anti-inflammatory mechanisms depending on the solvent used for fractionation.

A Study of Gamma-ray Distribution around the $^{99}Mo-^{99m}TcO_4$ Generator ($^{99}Mo-^{99m}TcO_4$ Generator의 감마선량 분포에 관한 연구)

  • Park, Soung-Ock
    • Journal of radiological science and technology
    • /
    • 제24권1호
    • /
    • pp.49-53
    • /
    • 2001
  • A number of radionuclides of interest in nuclear medicine are short lived isotopes that emit only gamma ray. The most of all Dept. of Nuclear Medicine in the hospt. are using the $^{99}Mo-^{99m}Tc$ generator for elution of the short lived isotope $^{99m}TcO_4$. A $^{99}Mo-^{99m}Tc$ generator consists of an alumina column on which $^{99}Mo$ is bound. The parent isotope($^{99}Mo$ : half life 67 hr.) decays to its daughter $^{99m}TcO_4^-$ which is a different element with a shorter half-life. $^{99}Mo$ emitted 41-keV(1.3%), 141-keV(5.6%) 181-keV(6.6%) and 366-keV(1.5%) gamma rays. But $^{99m}TcO_4$ emitted only 140-keV gamma ray. We study about the gamma ray distribution around the $^{99}Mo$ generator. And obtained the result as follows ; 1. Total counted gamma ray from generator smaller in front side than back. 2. The gamma ray emitted from $^{99}Mo$ generator without $^{99m}TcO_4$ vial increased in the back side(Mo column posited side) 3. The gamma ray only from the $^{99m}TcO_4$ vial increased in the front side. 4. Apron can protect gamma ray above 60% of total radiation from the $^{99}Mo$ generator.

  • PDF

Recurrent Malignant Thymoma Detected by Tc-99m MIBI, Tc-99m Tetrofosmin and Tc-99m (V) DMSA Scan (Tc-99m MIBI, Tc-99m Tetrofosmin, 그리고 Tc-99m (V) DMSA 스캔에 의해 발견된 재발성 악성 흉선종)

  • Seok, Ju-Won;Kim, Seong-Jang;Kim, In-Ju;Kim, Yong-Ki
    • The Korean Journal of Nuclear Medicine
    • /
    • 제35권4호
    • /
    • pp.268-273
    • /
    • 2001
  • Thymoma is the most common primary tumor of anterior mediastinum, accounting for 20% to 30% of all mediastinal tumors. The recurrence rate after total resection of the thymoma ranges 8% to 18%. We reported one patient of recurrent malignant thymoma imaged with Tc-99m MIBI, Tc-99m Tetrofosmin and Tc-99m (V) DMSA. Early and delayed Tc-99m MIBI and Tc-99m Tetrofosmin scintigraphies showed an increased uptake in the mediastinal area. Also, Tc-99m (V) DMSA scintigraphy revealed an increased uptake tn the corresponding area. Coronal SPECT images of Tc-99m MIBI, Tc-99m Tetrofosmin and Tc-99m (V) DMSA revealed increased uptake of each radiopharmaceutical in the tumor lesion corresponding to the mediastinal lesion on the chest CT. However, the normal blood pool activities of the heart and great vessels of Tc-99m (V) DMSA obscured the recurrent malignant thymoma. Although Tc-99m (V) DMSA is a useful tumor seeking agent, we recommend Tc-99m MIBI and Tc-99m Tetrofosmin SPECT rather than Tc-99m (V) DMSA to detect primary and recurrent malignant thymoma.

  • PDF

A Convenient Method on the Methyl-Ethyl-Ketone Extraction of $^{99m}TcO^-{_4}$ ($^{99m}TcO^-{_4}$의 메틸-에틸-케톤-간편 추출법)

  • Lee, Jong-Du;Lee, Byung-Hyn
    • Journal of Radiation Protection and Research
    • /
    • 제9권2호
    • /
    • pp.103-111
    • /
    • 1984
  • A convenient method of $^{99m}Tc$-methyl-ethyl-ketone (MEK) extraction technique was developed and a mobile $^{99m}Tc$-extraction generator was designed. The MEK extraction and the phase separation of $^{99m}TcO^-{_4}$ were carried out with a simple procedure in the same container. The shielding of $^{99}Mo$ radioactivity was made with one lead container. The system was simplified by shielding $^{99m}TcO_4{^-}({\gamma}_e=0.14\;MeV)$ separately. $^{99m}TcO^-{_4}\;in\;^{99m}Tc-MEK$ extract was recovered by adsorption and elution only, and therefore, the possibility of volatilization was reduced. The volume of $^{99m}TcO^{-}{_4}$-saline product was reduced to 1 ml by using a small alumina column and the column operation time was shortened. The separation time of $^{99m}Tc$ was reduced to 30 minutes, and the operation was carried out at the outside of the shielding. The system was designed to operate under the condition of bacteria-free.

  • PDF

$^{99m}Tc$-Tetrofosmin Scintimammography in Suspected Breast Cancer Patients: Comparison with $^{99m}Tc$-MIBI (유방암이 의심되는 환자에서 $^{99m}Tc$-Tetrofosmin을 이용한 유방스캔: $^{99m}Tc$-MIBI와 비교)

  • Kim, Seong-Jang;Kim, In-Ju;Kim, Yong-Ki;Bae, Young-Tae
    • The Korean Journal of Nuclear Medicine
    • /
    • 제34권2호
    • /
    • pp.119-128
    • /
    • 2000
  • Purpose: The aim of this study was to investigate the diagnostic role of $^{99m}Tc$-Tetrofosmin in detection of breast cancer and compared with that of $^{99m}Tc$-MIBI. Material and Methods: Forty-eight patients with a clinically palpable mass or abnormal mammographic or ultrasonographic findings had $^{99m}Tc-MIBI\;and\;^{99m}Tc$-Tetrofosmin scintimammographies after intravenous injection of 925 MBq of radiopharmaceuticals. The scintimammographs were correlated with histopathologic findings. Results: Thirty-three patients were diagnosed with breast cancer and 15 patients with benign breast diseases. The numbers of true positive, true negative, false positive, and false negative cases of $^{99m}Tc$-MIBI scintimammography were 29, 10, 5, and 4 respectively. The sensitivity, specificity, positive predictive value, and negative predictive value of $^{99m}Tc$-MIBI scintimammographies were 87.8%, 66.7%, 85.3%, and 71.4% respectively. The numbers of true positive, true negative, false positive, and false negative cases of $^{99m}Tc$-Tetrofosmin were 31,10, 5, and 2 respectively. The sensitivity, specificity, positive predictive value, negative predictive value of $^{99m}Tc$-Tetrofosmin were 93.9%, 66.7%, 86.1%, and 73.3% respectively. One patient was false negative in both $^{99m}Tc-MIBI\;and\;^{99m}Tc$-Tetrofosmin acintimammographies and its size was 0.5 cm. Conclusion: $^{99m}Tc-Tetrofosmin\;and\;^{99m}Tc-MIBI$ were non-invasive and useful in detection of breast cancer and $^{99m}Tc$-Tetrofosmin was comparable to the $^{99m}Tc$-MIBI in detection of primary breast cancer.

  • PDF

Analysis of $^{99}Tc$ and Its Activity Level in the Korean Soil (한국 토양의 $^{99}Tc$ 분석 및 방사능 농도 준위)

  • Lee, Chang-Woo;Chung, Kun-Ho;Cho, Young-Hyun;Kang, Mun-Ja;Lee, Wan-No;Kim, Hee-Reyoung;Choi, Geun-Sik
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • 제7권1호
    • /
    • pp.25-31
    • /
    • 2009
  • An analytical method of $^{99}Tc$ concentration in soil was set up and discussed considering the $^{99}Tc$ concentration in Korean soil measured with its analytical method. A selective TEVA resin was used to separate and purify the $^{99}Tc$ in the soil sample. $^{99m}Tc$ from a commercial $^{99}Mo/^{99m}Tc$ generator was used as a yield tracer for the chemical separation of $^{99}Tc$ and its problem when using $^{99m}Tc$ as a tracer was discussed. The chemical recovery yield of $^{99}Tc$ was above 70%. The optimum conditions of inductively coupled plasma mass spectrometry system(ICP-MS) were set up to determine the $^{99}Tc$ after the separation process. The minimum detectable activity(MDA) was 15 mBq/kg-dry in this analytical procedure. The $^{99}Tc$ concentration in soils of Jeju and Kori were measured in the rage of 33.73-89.16 mBq/kg-dry. Those values were less than those reported in other countries and seemed to be originated from atmospheric fallout.

  • PDF

Excellent Strains Selection from Wild Cordyceps spp.(I) (야생동충하초로부터 우량균주선발 (I))

  • 방극소;조덕현
    • Korean Journal of Plant Resources
    • /
    • 제13권3호
    • /
    • pp.155-161
    • /
    • 2000
  • Many Cordyceps rpp were collected for excellent strains selection at Mts. Moak, Younsuk and Daea-ree herbarium near Wanju-kun from mid May to October,1999. They were identified as the resulting 2 genera and 5 species, 10 strains were got through 5 species culture. Among them 4 species used for induction of artifitial fruiting body and 6 strains of them were selected to excellent strains: Cordyceps militaris (99-0007), Isaria japonica (99-0001, 99-0002, 99-0003), Cordyceps soborifera (99-0008), Cordyceps kanzashiana(99-0009).

  • PDF

Camparison of the Efficiency for Tc-99m Tin-colloid and Tc-99m Phytate in Sentinel Node Detection in Breast Cancer Patients (유방암 환자의 전초림프절 검사에서 Tc-99m Tin-colloid와 Tc-99m Phytate의 효용성에 대한 비교)

  • Seok, Ju-Won;Kim, In-Ju
    • Nuclear Medicine and Molecular Imaging
    • /
    • 제42권6호
    • /
    • pp.451-455
    • /
    • 2008
  • Purpose: Lymphoscintigraphy and sentinel node biopsy has become a standard method for detection of axillary lymph node metastasis in breast cancer patients, but the standard radiopharmaceutical was not prepared. About detection of axillary lymph node metastasis by lymphoscintigraphy and sentinel node biopsy in breast cancer patient, we compared the results of Tc-99m Tin-colloid and Tc-99m Phytate by subareolar injection. Materials and Methods: This study included 382 breast cancer patients who were performed operation during 2001-2008. Three hundred forty nine patients was injected 0.8ml of Tc-99m Tin-colloid (37-185 MBq) by subareolar injection. Thirty three patients was injected 0.8ml of Tc-99m Phytate (37-185 MBq). Lymphoscintigraphy was performed in supine position and sentinel node localization was performed by hand-held gamma probe in operation. Result: Among 349 patients by Tc-99m Tin-colloid, 312 cases (89.4%) localized the sentinel node by lymphoscintigraphy, 304 cases (87.1%) localized by gamma probe. Among 33 patients by Tc-99m Phytate, 32 cases (97.0%) localized by lymphoscintigraphy, 33 cases (100%) localized by gamma probe. Detection rate by lymphoscintigraphy and gamma probe was superior for Tc-99m Phytate compared to that with Tc-99m Tin-colloid, with a statistically significant difference. (p<0.05, p<0.05) Conclusion: Tc-99m Phytate is a better choice for localization of sentinel node than Tc-99m Tin-colloid in breast cancer patients.

Fibrous Dysplasia Associated with Primary Hyperparathyroidism Absent of McCune-Albright Syndrome: Tc-99m MIBI and Tc-99m MDP Findings

  • Kim, Seong-Jang;Seok, Ju-Won;Kim, In-Ju;Kim, Yong-Ki;Kim, Dong-Soo
    • The Korean Journal of Nuclear Medicine
    • /
    • 제37권2호
    • /
    • pp.128-134
    • /
    • 2003
  • 섬유성 골이형성증은 비정상적인 섬유성 골조직으로 대체되며 느리게 진행하는 골병변이다. 섬유성 골이형성증과 부갑상선기능항진증은 흔하게 관찰되는 질환이나 McCune-Albright 증후군 없이 일차성 부갑상선기능항진증에 동반된 섬유성 골 이형성증은 거의 보고된바가 없다. Tc-99m MDP 골스캔이 섬유성 골이형성증의 진단에 유용하다고 알려져 있으나, Tc-99m MIBI 영상은 아직 보고된 바가 없다. 저자들은 McCune-Albright 증후군이 없이 부갑상선기능항진증에 동반된 섬유성 골 이형성증의 Tc-99m MIBI 스캔과 Tc-99m MDP 골스캔의 영상을 비교하였다. Tc-99m MDP 골스캔상 병변 부위에서 증가된 섭취 소견을 보였으며, Tc-99m MIBI 조기영상에서도 동일한 위치에서 섭취증가가 관찰되었다. 2시간 지연 Tc-99m MIBI 영상에서는 Tc-99m MIBI의 섭취가 배출되는 소견을 보였다. 섬유성 골이형성증 병변에서 Tc-99m MIBI 스캔이 유용할 것이라고 생각하며, 섬유성 골이형성증 병변에서 Tc-99m MIBI의 섭취를 증가시키는 인자에 대한 더 많은 연구가 필요할 것으로 생각한다.

Effect of $Al^{3+}$ on Labeling Efficiency and Biodistribution of $^{99m}Tc$-MDP ($Al^{3+}$ 존재가 $^{99m}Tc$-MDP의 표지효율과 생체내 분포에 미치는 영향)

  • Chang, Young-Soo;Jeong, Jae-Min;Kim, Young-Ju;Kwark, Cheol-Eun;Lee, Dong-Soo;Chung, June-Key;Lee, Myung-Chul;Koh, Chang-Soon
    • The Korean Journal of Nuclear Medicine
    • /
    • 제30권3호
    • /
    • pp.361-366
    • /
    • 1996
  • This study was to determine the effect of $Al^{3+}$ in $^{99m}Tc$ eluate from $^{99}Mo-^{99m}Tc$ generator on labeling efficiency and biodistribution of $^{99m}Tc$-MDP. The chromatographic analysis of $^{99m}Tc$-MDP preparations containing $Al^{3+}(0-62.5{\mu}g/ml)$ showed decreased labeling efficiency $^{99m}Tc$ pertechnetate and hydrolyzed reduced $^{99m}Tc$ fraction increased with increasing concentrations of aluminum. However, the chromatography system could not discern between hydrolyzed reduced $^{99m}Tc$ and $^{99m}Tc$ labeled colloid. $^{99m}Tc$-MDP preparations containing aluminum were relatively stable. Chromatographic analysis also confirmed that no significant differences were observed in the radiochemical purity of the filtered and the unfiltered $^{99m}Tc$-MDP preparations containing aluminum by $0.22{\mu}m$ syringe filter. In biodistribution data of ICR-mice, blood and heart uptake were increasing with increasing concentrations of aluminum, because of decreasing labeling efficiency of $^{99m}Tc$-MDP and increasing of $^{99m}Tc$ pertechnetate. However, liver and bone uptake were not significantly increased. In rat images no difference were observed at $5{\mu}g/ml\;Al^{3+}$ compare with at $0{\mu}g/ml\;Al^{3+}$, but at $10{\mu}g/ml\;Al^{3+}$ lumbar uptake was increased. As a practical conclusion, a concentration below $10{\mu}g/ml\;Al^{3+}$($10{\mu}g/ml\;Al^{3+}$ is the maximum allowed in pertechnetate eluate from $^{99}Mo-^{99m}Tc$ generator by USP.) in $^{99m}Tc$-MDP radiopharmaceutical result in low labeling efficiency. Radiochemical purity 90% of $^{99m}Tc$-MDP is the minimum allowed by USP. Therefore, when soft tissue uptake is observed in $^{99m}Tc$-MDP bone scan and labeling efficiency is above 90%, we can expect that $Al^{3+}$ in pertechnetated eluate is not the cause of soft tissue uptake.

  • PDF