• 제목/요약/키워드: 97C9

검색결과 1,108건 처리시간 0.032초

수도(水稻)에 처리(處理)된 유기수은제(有機水銀劑)의 잔류성(殘留性)에 관(關)한 연구(硏究) -제1보(第1報) 침지용유기수은제(浸漬用有機水銀劑)로 처리(處理)된 수도종자중(水稻種子中)의 수은잔류량(水銀殘留量)에 관(關)하여- (Studies on the Organo-mercury Residues in Rice Grain -I. Mercury residues in rice seeds treated with organo-mercury fungicide-)

  • 이동석
    • Applied Biological Chemistry
    • /
    • 제8권
    • /
    • pp.87-93
    • /
    • 1967
  • acaricide로 알려진 phthalimidomethyl O,O-dimethyl phosphorodithioat (Imidan)을 수도(水稻)에 살포(撒布)했을 때 Imidan과 그 대사물질(代謝物質)이 식물(植物)의 생육(生育)에 미치는 영향(影響)을 연구(硏究)하기 위하여 본(本) 실험(實驗)을 하였으며 이의 결과(結果)를 요약(要約)해 보면 다음과 같다. (1) Imian의 대사물질(代謝物質)로 예상(豫想)되는 다음의 8가지 화합물(化合物)을 합성(合成) 또는 정제(精製)하여 공시약제(供試藥劑)로 사용(使用)하였다. (a) N-Hydroxy methyl phthalimide (b) Phalimide (c) Phthalamdic acid (d) Phthalic acid (e) Anthranilic acid (f) p-amino benzoic acid (g) p-hydroxu benzoic acid (h) Benzoic acid (2) 상기(上記) 물질중(物質中)에서 (a),(c),(d),(e)와 Imidan의 각(各) 10 ppm과 20 ppm 의 Buffer Solution 을 만들어 밀 종자(種子)를 가지고 coleoptile straight growth test를 해 본 결과(結果) Imidan 은 10 ppm 과 20 ppm에서 모두 control 보다 생장(生長)의 촉진효과(促進效果)를 보였으며 기중(其中) phthalamidic acid 10 ppm 이 가장 좋은 성적(成績)을 보였다. 이것으로 보아 Imidan 자체(自體)는 생장(生長) 억제(抑制)의 효과(效果)를f 보이나 이것이 일단(一但) 생체내(生體內)에서 가수분해(加水分解)를 비롯한 각종(各種) 대사작용(代謝作用)을 받으면 그 대사산물(代謝産物)이 식물생장(植物生長)을 촉진(促進)하는 효과(效果)를 보이는 것 같다. (Table 1, Fig. 1 참조(參照)) (3) xylene을 용매(溶媒)로 하여 Imidan 유제(乳劑)를 만들고 이것을 희석(稀釋)하여 20 ppm, 100 ppm 및 200 ppm 의 각(各) 농도(濃度) 유화액(乳化液)을 조제(調製)한 후 이것을 배지(培地)로 하여 수도종자(水稻種子)를 발아(發芽)시킨 후 12 일(日)에 shoot와 root의 길이를 측정(測定)하였다. 이의 결과(結果)를 보면 root는 Imidan 20 ppm에서, shoot 는 Imidan 100 ppm에서 모두 xylene만의 유제구(乳劑區)인 control 보다 좋은 효과(效果)를 보였으며 여기에서 흥미(興味)있는 것은 용매(溶媒)로 사용(使用)된 xylene은 수도종자(水稻種子) 뿌리의 발육(發育)에 심(甚)한 억제효과(抑制效果)를 보이는 것 같다. (Table 2, Table 5 참조(參照)) (4) 벼를 pot에 심고 2회(回)에 걸쳐 control, Imidan, N-hydroxy methyl phthalimide, anthranilic acid 및 phthalimide의 10, 25, 50, 100 ppm 농도(濃度)의 각(各) 유제(乳劑)를 살포하고 일정기간후(一定期間後) 생육상(生育相)을 조사(調査)하였더니 Imidan 구(區)와 N-hydroxy methyl phthalimide 구(區)가 control 보다 좋은 성적(成績)을 보였다. (5) Imidan 250 ppm 유제(乳劑)를 수도엽면(水稻葉面)에 살포(撒布)하고 3 일(日), 5 일(日), 7 일(日) 및 14일후(日後)에 일정량(一定量)의 엽경(葉莖)을 채취(採取)하여 acetone으로 추출(抽出)k고 acetonitrile을 가지고 prechromatographic piriication 을 거쳐 paper chromatography에 의(依)하여 다음과 같은 대사물질(代謝物質)을 검출(檢出)하였다. Imidan $(Rf:\;0.97{\sim}0.98)$, N-hydroxy methyl phthalimide (Rf: 0.87), phthalimide $(Rf:\;0.86{\sim}0.87)$, phthalamidic acid $(Rf:\;0.13{\sim}0.14)$, phthalic acid $(Rf:\;0.02{\sim}0.03)$, benzoic acid $(Rf:\;0.42{\sim}0.43)$ 및 p-amino benzoic acid 또는 p-hydroxy benzoic acid $(Rf:\;0.08{\sim}0.09)$와 Rf=0.73, 0.59, 0.33, 0.23, 0.07의 미지물질(未知物質)을 검출(檢出)하였다. 또한 3일(日), 5일(日) 등(等) 초기(初期)에서는 미분해(未分解)의 Imidan과 최초(最初)의 가수분해(加水分解) 산물(産物)인 N-hydroxy methyl phthalimide등(等)이 비교적(比較的) 다량(多量)으로 검출(檢出)되었으나 7일(日), 14일(日) 등(等) 후기(後期)에는 생체내(生體內)에서 더 많은 분해(分解)를 받아 상기(上記) 이성분(二成分)은 양(量)이 감소(減少)되고 phthalic acid, phthalamidic acid benzoic acid 및 p-hydroxy benzoic acid 또는 p-amino benzoic acid등(等)의 양(量)이 증가(增加)되는 것을 볼 수있었으며 도체상(稻體上)에 살포(撒布)된 Imidan 은 체내(體內)에 흡수(吸收)되어 14일(日)이 경과(經過)되면 대부분(大部分)이 분해(分解)를 받는 것으로 보여진다. 이상(以上)의 결과(結果)로 보아 Imidan은 자체(自體)로서는 식물생장(植物生長) 촉진작용(促進作用)이 없으나 식물체내(植物體內)에서 여러 가지 대사작용(代謝作用)(enzyme의 작용(作用))을 맡아서 각종(各種) phthaloyl 영향(影響)을 주는 것으로 생각(生覺)된다.

  • PDF

규산 및 삼요소 시비수준이 도체내 성분함량과 도열병 발생에 미치는 영향 (The Effects of Silicate Nitrogen, Phosphorus and Potassium Fertilizers on the Chemical Components of Rice Plants and on the Incidence of Blast Disease of Rice Caused by Pyricularia oryzae Cavara)

  • 백수봉
    • 한국응용곤충학회지
    • /
    • 제14권3호
    • /
    • pp.97-109
    • /
    • 1975
  • 수도 도열병의 종합적 방제체계 확립의 일환으로서 합리적인 비료 시용에 의한 효과적 방제 가능성을 알고다 규산, 질소, 인산 및 가리 등 여러 비료를 시용하여 이들이 도체내 성분함량과 도열병 발생에 미치는 영향을 검토하고 나아가 수도품종 및 균주간의 상호관계를 구명하기 위하여 1971년과 1973년에 수도묘에 도열병균을 인공접종 및 자연발병시켜 실험을 실시하였던 바 다음과 같은 결과를 얻었다. 1) 규산을 시용하면 수도 엽신내 규산함량은 크게 증가하고 전당함량과 가리함량도 증가하나 전질소 및 인산함량은 감소되었다. 2) 규산의 시용으로 도체내 C/N 율과 $SiO_2/N$율 및 $K_2O/N$율은 향상되었으며 이들과 도열병 발병지수와는 고도의 부의 상관이 있었다. 3) 규산시용으로 도열병 발병지수는 저하되었다. 4) 도체내 규산함량은 질소질비료를 과용하면 감소되고 전질소함량은 증가되며 전당함량은 감소하여 도열병 저항성을 크게 저하시켰다. 5) 규산함량은 인산질비료를 많이 시용하거나 도체내 인산함량이 증가하면 감소되어 도열병에 대한 저항성을 저하시켰다. 6) 가리질비료를 다시용하면 규산함량은 증가되었고 전질소함량은 감소되었으며 $K_2O/N$율은 증가되는 경향이었다. 그리고 가리함량이 비교적 낮은 상태에서는 도열병에 대한 저항성이 향상되었으나 비교적 높은 수준에서는 도열병에 대한 저항성과 유의적인 상관이 보이지 않았다. 7) 도열병 발병지수는 공시된 균주범위내에서 진흥이 적었고 풍옥이 가장 컸으며 풍광 팔달은 비슷한 정도였다. 도열병균의 병원성은 $P_1,\;P_2,\;and\;P_3$의 순으로 강하였으나 풍옥에 있어서는 일정한 경향을 찾아볼 수 없었다. 엽위별로는 5-6엽기의 묘에서 상위 제2엽이 발병이 많았고 제1엽과 제3엽은 비슷한 정도였다.품종이기 때문인 것 같다. (4) 벼의 수량은 무처리 5,814kg/ha에 비하여 Carbofuran 6,649kg, Cytrolane 6,340kg, BPMC 6,315kg, Chlorphenamidine 6,265kg, Cartap 6,164kg, Diazinon 5,944kg, Diazinon 입제 수면시용 6,102kg로서 Carbofuran 처리구에서 벼의 수량이 가장 높았다. (5) Carbofuran 처리구에서 높은 수량을 보인 것은 Carbofuran 처리구에서 멸구, 매미충류의 밀도가 낮았고 오갈병의 발병율이 낮은데서 온 결과인 것 같다.화안정성은 없었다. 포말성은 87.5$\pm$$2.5\%$였고 용해도는 산성영역 (pH 2와 4)에서 약 83$\~$$84\%$로 높았으나 pH 6이상에서는 44$\~$$50\%$로 낮았다. 보였다.이 한국어와는 다른 것이라거나, 한국어 음성학을 공부하지 않고 한국어를 연구할 수 있다는 뜻은 아닙니다. 의학에도 분야마다 전문의가 있듯이, 언어학도 이제 복잡하고 광범한 학문이 되었으므로 분야별로 전문가가 나오게 된 것뿐입니다. 따라서 "나는 통사론에 관심이 있으므로 소리말에는 관심이 없다"고 말하는 언어학자가 있다면, 이 것은 크게 잘못된 것입니다. 마찬가지로 "나는 소리에만 관심이 있으므로 통사론에는 관심이 없다"고 말하는 음성학자가 있다면, 이 또한 안되는 일입니다. 문의 구성과 어휘 요소와 아무 관련이 없는 말소리의 차이가 무슨 소용이 있으며, 통사 구조를 표현하고 저달하는 말소리를 연구하지 않고 어떻게 통사론을 연구할 수 있겠습니까? 다시 간추리면, 언어는 본질적으로 소리말이고, 언어의 특성과 사용 및 습득도 모두 소리말 형태로 나타납니다. 따라서, 영국의 대학은

  • PDF

Streptococcus faecium의 급여가 육계의 성장과 장내 세균총 변화에 미치는 영향 (Effect of Dietary Streptococcus faecium on the Performances and the Changes of Intestinal Microflora of Broiler Chicks)

  • 김경수;지규만;이상진;조성근;김삼수;이웅
    • 한국가금학회지
    • /
    • 제18권2호
    • /
    • pp.97-119
    • /
    • 1991
  • 본 실험은 육계에서 생균제 Streptococcus faecium C-68(SF)과 항생제 colistin (Col)의 단독 또는 혼합 급여가 증체율과 장내 세균총 변화에 미치는 영향을 조사하기 위하여 실시하였다. 암수 동수의 초생추 252수를 공시하여 Col과 SF를 첨가하지 않은 기초사료구(대조구), 기초사료+Col 10ppm첨가구, SF 0.04%구, SF 0.04%+col 10ppm구, SF 0.08%구, SF 0.08%+col 10ppm구 등 6개 처리구를 두었다. SF 0.04%구와 SF 0.08%구의 Streptococcus faecium 생균수는 사료 g당 각각 7$\times$10난, 1.4$\times$10개가 되도록 하였고, 사료는 옥수수와 대두학을 주원료로 하여 7주간 급여하였다. 사양실험이 진행되는 동안 처리구별로 분내 세균총의 변화를 알아보기 위하여 매주 말 신선한 분을 사료로 무균적으로 채취하여 조사하였고, 장내 세균총의 변화를 조사하기 위해 4주와 7주말에 처리당 9수씩 희생시켜 대장부분의 내용물을 채취하여 세균총의 분포를 조사하였다. 각 처리구 실험사료의 영양소 이용률을 조사하기 위하여 3주와 6주말 전분 채취법에 의하여 대사실험을 실시하였고, 7주말 각 처리구 별로 9수씩 희생시켜 소장의 길이와 무게를 측정하였다. 평균 증체량은 SF 0.08%(2.37kg)와 SF 0.08%+col (2.34kg)을 첨가한 처리구가 대조구(2.18kg)보다 유의적으로 높았으나 (P<0.05), 다른 처리구의 증체량은 대조구에 비하여 통계적인 차이가 없었다. 사료요구율은 SF 0.04%구를 제외한 모든 첨가구들이 대조구보다 더 개선되었고(P<0.05), 건물, 조단백질, 조지방, 총 탄수화물 등과 같은 영양소의 소화율은 전 기간 내내 SF나 Col의 첨가에 의한 변화를 볼 수 없었다. 예상했던 대로 SF첨가구의 분 중 Streptococci는 유의성 있게 증가되었는데 SF 0.04%구와 SF 0.08%구, SF 0.08%+col구에서는 통계적인 유의성이 인정되었다(P<0.05). 그러나 colistin의 단독첨가에 의한 Streptococci의 변화는 볼 수 없었고 Col과 SF와의 혼합 첨가구에서도 Col첨가가 Streptococci수의 변화에 미치는 영향은 볼 수 없었다. 분 중의 coliforms수는 SF와 Col의 첨가된 사료의 급여에 의해 현저히 감소되었다(P<0.05) 그러나 SF와 Col의 혼용효과는 관찰할 수 없었다. 장내 세균총의 분포 변화도 분중의 세인총 변화와 같은 양식을 나타냈다. 소장의 길이는 SF 0.08%구와 SF 0.08%+col 10ppm구에서 SF를 급여하지 않은 처리구보다 10%정도 유의하게 긴 것으로 나타났다(P<0.05). 그러나 소장의 무게(empty weight)는 대조구에 비하여 SF 0.08%구와 SF 0.08%+col구에서 가벼워졌고, Col과 SF를 단독 또는 혼용 급여한 모든 처리구의 단위길이 당 소장무게는 유의성 있게 감소된 것을 볼 수 있었다(P<0.05). 전체적인 결과를 볼 때 SF가 0.08%첨가된 구에서 육계의 증체량 개선효과가 가장 좋은 것으로 나타났다. 10ppm의 colistin첨가는 SF와 혼용했을 때나 10ppm 그 자체만으로는 육계의 증체효과 또는 양내 세란총 변화의 관점에서 볼 때 유익하지 못했고, SF와 Col은 소장의 벽 두께를 않게 변화시키는 효능이 있다고 추측된다.

  • PDF

논벼재배에 있어서의 노동력 절감에 관한 연구 (A Study on Labor Saving in Paddy Rice Cultivation)

  • 장영철
    • 한국작물학회지
    • /
    • 제11권
    • /
    • pp.81-97
    • /
    • 1972
  • 논벼농사의 노동력을 덜기 위하여 이중 가장 중요한 호미질에 의한 중경제초의 노력을 살초제에 의한 것으로 전환시키고자 기초적인 면과 실제적인 면으로 시험조사를 하였다. 건국대학교에서 1m평방 안높이 21cm 및 36cm의 두 형의 concrete tank를 각 4개씩 만들고 그 안에 채수관장치를 한 뒤 양토작토로 논벼를 심어 수도물로 관수하고 투수속도와 산소침투 정도와 수량과의 관계를 보았다. 농림부 자재 검사소 내에서 투수가 심한 사질답전포장에 전면적으로 살초제 Stam F-34를 살포하여 제초하고 제 1구는 중경을 하지 않고, 제 2구는 중경 1회, 그리고 제 3구는 중경 2회하여 중경의 효과를 비교하였다. 이리 호남시험장내 건답보통논과 습답에 무중경, 중경 1회 중경 2회의 구와 살초제 Pamcon을 살포한 것들 중, 무중경, 중경 1회 제초 2회, 중경 2회 제초 1회, 중경 3회 제초 2회의 구와 그리고 관행구를 설치하여 중경제초의 비용과 살초제에 의한 비용을 비교하였던바 그 결과를 요약하면 다음과 같다. (1) 투수속도와 산소침투와 수량과의 관계는 일당(24시간당) 투수속도 4cm이상 될 때 지표 2cm하에 산소가 조금 들어가며 3cm보다 적을 때는 산소가 지표하의 매우 옅은 층에만 내려가는 것으로 나타나며 그리고 경심 15cm구에는 일당 투수속도의 0cm(무투수) 1.5cm에서 수량이 많고 2.5cm와 3.4cm에는 감수되며, 경심 30cm구에는 투수속도 1.5cm 및 30cm구에서 수량이 많고 무투수와 투수속도 4cm구에는 수량이 떨어졌다. (2) 투수가 심한 농림부 자재검사소 사질토양에서는 중경의 효과가 없었다. (3) 호남작물시험장내 건답에서는 살초제 Pamcon 처리 무중경구 수량에 대해서 유의성이 보이는 증수구는 없었다. 그리고 습답에서는 무중경구에 있어서 중경제초 및 관행구가 유의성 있게 증수되었다. (4) 논매기 호미질에 의한 10a당 노동력은 정미 37.1시간 식사와 휴식시간 포함하여 53.5시간이고, 노임은 2,346원인데 대하여 살초제 사용에의 한제 초노력은 수동식으로 0.5일 즉 약 5시간 제비용과 감수추정량을 추정할 때 1,130원이고 습답을 제외하면 750원이 되는 것으로 추정 되었다.

  • PDF

Sensory Information Processing

  • Yoshimoto, Chiyoshi
    • 대한의용생체공학회:의공학회지
    • /
    • 제6권2호
    • /
    • pp.1-8
    • /
    • 1985
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70$\pm$1.32mmHg/min)compared to CF dialyzers(4.32$\pm$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500, 550, 570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500, 550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100, 300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3, 000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.SpO2 with Plethysmograph.

  • PDF

High Resolution HC$_3$N Observations toward the Central Region of Sagittarius B2

  • H.S-Ching;Oh, M.ishi;M.Morimoto
    • 한국우주과학회:학술대회논문집(한국우주과학회보)
    • /
    • 한국우주과학회 1993년도 한국우주과학회보 제2권2호
    • /
    • pp.17-17
    • /
    • 1993
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70${\pm}$1.32mmHg/min)compared to CF dialyzers(4.32${\pm}$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500,550,570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500,550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100,300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3,000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.

  • PDF

동력경운기(動力耕耘機) 이용실태(利用實態) 조사분석(調査分析)(II) -고장(故障) 및 수리(修理)에 관(關)하여- (A Survey on the Break-down and Repair of the Power Tillers in Korea)

  • 홍종호;이채식
    • Journal of Biosystems Engineering
    • /
    • 제6권1호
    • /
    • pp.28-38
    • /
    • 1981
  • 동력경운기(動力耕耘機)의 효율적(效率的)인 이용(利用)과 고장(故障)으로 인(因)한 문제점(問題點)과 그에 따른 대책(對策)을 강구(講究)하기 위(爲)한 기초자료(基礎資料)를 제시(提示)코저 전국(全國) 8개도 278농가(農家)를 대상(對象)으로 동력경운기(動力耕耘機)의 각종(各種) 고장(故障) 및 수리실태(修理實態)를 조사분석(調査分析)한 결과(結果)는 다음과 같다. 가. 고장빈도(故障頻度) 동력경운기(動力耕耘機)의 대당(臺當) 년간(年間) 고장발생(故障發生) 빈도(頻度)는 9.05회(回)이었으며 평균(平均) 39.1시간(時間) 작업(作業)에 1회(回)의 고장(故障)이 발생(發生)되었다. 고장빈도(故障頻度)가 가장 높았던 곳은 점화연료공급계통(點火燃料供給系統)으로서 2.02회(回)로 전체고장(全體故障)의 22.3%를 차지하였고, 그 다음이 부속작업기(附屬作業機) 시린더계통(系統), 주행장치등(走行裝置等)의 순서(順序)로 나타났다. (2) 동력경운기(動力耕耘機) 사용년수별(使用年水別) 고장(故障) 발생빈도(發生頻度)는 구입후(購入後) 6년(年) 이하(以下) 경과(經過)된 기계(機械)에서 37.7시간(時間) 사용(使用)에 1회(回)의 고장(故障)이 발생(發生)된 것으로 나타나 가장 높았고 그 다음이 구입후(購入後) 2년(年) 미만(未滿)된 기계(機械)로서 38.6시간(時間) 작업(作業)에 1회(回)이 고장(故障)이 발생(發生)되었다. (3) 동력경운기(動力耕耘機) 기종별(機種別) 고장(故障) 발생빈도(發生頻度)는 석유(石油)엔진이 36.3시간(時間) 작업(作業)에 1회(回)의 고장(故障)이 발생(發生)되어 디젤엔진의 42.8시간(時間)보다 높았고 마력별(馬力別)로는 석유(石油)엔진의 경우(境遇) 8마력(馬力)이 10마력(馬力)보다 고장(故障) 발생빈도(發生頻度)가 높게 나타났다. (4) 동력경운기(動力耕耘機) 월별(月別) 고장(故障) 발생빈도(發生頻度)는 10월(月)에 가장 낮아 51.5시간(時間) 작업(作業)에 1회(回)의 고장(故障)이 발생(發生)되었고 그 다음이 6월로 49.7시간(時間) 작업(作業)에 1회(回)의 고장(故障)이 발생(發生)된 것으로 나타나 작업시간(作業時間)이 많았을 때 고장(故障) 발생빈도(發生頻度)는 상대적(相對的)으로 적었던 것으로 나타났다. 나. 수리장소(修理場所) (1) 동력경운기(動力耕耘機) 고장시(故障時)의 수리장소(修理場所)는 자가수리(自家修理)가 평균(平均) 45.3%이었고 공장수리(工場修理)가 54.7%로 나타나 공장수리(工場修理)가 자가수리(自家修理)보다 많았다. (2) 동력경운기(動力耕耘機) 사용년수별(使用年數別) 수리장소(修理場所)는 구입후(購入後) 경과년수(經過年數)가 길어질수록 공장수리(工場修理)보다 자가수리(自家修理)가 많아지는 것으로 나타났다. (3) 동력경운기(動力耕耘機) 자가수리율(自家修理率)은 디젤엔진이 석유(石油)엔진보다 높았으며 석유(石油)엔진에서는 10마력(魔力)이 디젤엔진에서는 8마력(魔力)이 높았다. (4) 고장부위별(故障部位別) 자가수리(自家修理) 비율(比率)은 조향장치(操向裝置)가 가장 높아 66.7%였으며 그 다음이 점화연료계통(點火燃料系統)인 것으로 나타났고 자가수리비율(自家修理比率)이 가장 낮는 곳은 부속작업기(附屬作業機)로서 26.5%에 불과(不過)하였다. 다. 고장원인(故障原因) (1) 동력경운기(動力耕耘機) 고장원인(故障原因)은 기계(機械)의 노후(老朽)에 의(依)한 고장(故障)이 년간(年間) 대당(臺當) 5.18회(回)로 전체(全體)의 57.2%를 차지하여 가장 많았고 정비불량(整備不良)과 과부하(過負荷)로 인(因)한 고장(故障)이 전체(傳遞)의 37.7%이었다. (2) 동력경운기(動力耕耘機) 구입후(購入後) 2년(年) 미만(未滿)의 기종(機種)에서는 정비불량(整備不良)으로 인(因)한 고장(故障)이 많았던 반면(反面) 노후(老朽)로 인(因)한 고장(故障)이 적었다. (3) 동력경운기(動力耕耘機) 고장원인(故障原因)은 기종별(機種別) 마력별(馬力別) 공(共)히 노후(老朽)로 인(因)한 고장(故障)과 과부하(過負荷)로 인(因)한 고장(故障)이 대부분(大部分)이었으며 특히 석유(石油) 5마력(馬力)엔진에서는 과부하(過負荷)로 인(因)한 고장(故障)이 월등히 높았다. (4) 동력경운기(動力耕耘機) 부위별(部位別) 고장원인(故障原因)은 시린더 계통(系統)과 주행장소(走行場所)의 고장(故障)에서는 주(主)로 노후(老朽)에 의(衣)한 원인(原因)이 많았던 반면(反面) 점화연료계통(點火燃料系統)의 고장(故障)에서는 정비불량(整備不良)으로 인한 고장(故障)이 많았다. 라. 수리비율(修理(比率) (1) 동력경운기(動力耕耘機) 년간(年間) 대당(臺當) 수리비(修理費)는 34,509원이었고 동력경운기(動力耕耘機) 1시간(時間) 수업당(修業當) 평균(平均) 수리비(修理費)는 97원이었다. (2) 동력경운기(動力耕耘機) 기종별(機種別) 수리비(修理費)는 석유(石油)엔진이 40,697원으로 디젤엔진의 28,322원보다 훨씬 많았다. (3) 동력경운기(動力耕耘機) 기종별(機種別) 1시간(時間) 수업당(修業當) 평균(平均) 수리비(修理費)는 석유(石油)엔진이 108원으로 디젤엔진의 86원보다 많았으며 마력별(馬力別)로는 차이(差異)가 없었다. (4) 동력경운기(動力耕耘機) 고장부위별(故障部位別) 년간(年間) 수리비(修理費)는 시린더 계통(系統)이 13,036원으로 가장 많았으며 조향장치(操向裝置)가 362원으로 가장 적었다. (5) 동력경운기(動力耕耘機) 1회(回) 수리시(修理時)의 평균(平均) 수리비(修理費)는 3,713원이었으며 시린더계통(系統)이 10,598원으로 가장 많았고 조향장치(操向裝置)가 1,006원으로 가장 적었다. 마. 자가수리소요시간(自家修理所要時間) 및 고장(故障)으로 인(因)한 불가동시간(不稼動時間) (1) 동력경운기(動力耕耘機) 년간(年間) 대당(臺當) 자가수리(自家修理) 소요시간(所要時間)은 8.36시간(時間)이었고 고장(故障)때문에 작업(作業)하지 못한 시간(時間)은 년간(年間) 대당(臺當) 93.5시간(時間)이었다. (2) 동력경운기(動力耕耘機) 사용년수별(使用年水別) 자가수리시(自家修理時)의 1회수리당(回修理當) 소요시간(所要時間)은 6년이상(年以上) 경과(經過)된 기계(機械)에서 21.3시간(時間)으로 가장 높았고 고장(故障) 때문에 사용(使用)하지 못한 시간(時間)은 2년(年) 미만(未滿)된 기계(機械)에서 년간(年間) 대당(臺當) 127.13시간(時間)으로 나타나 가장 높았다. (3) 동력경운기(動力耕耘機) 기종별(機種別) 자가수리시(自家修理時)의 1회(回) 수리당(修理當) 소요시간(所要時間)은 디젤엔진이 10.66시간(時間)으로 석유(石油)엔진의 6.48시간(時間)보다 많았고 고장(故障)으로 인(因)하여 가동(稼動)하지 못한 시간(時間)은 석유(石油)엔진이 년간(年間) 대당(臺當) 99.4시간(時間)으로 디젤엔진의 88.67시간(時間)보다 많았다. (4) 동력경운기(動力耕耘機) 마력별(馬力別) 자가수리시(自家修理時)의 1회수리당(回修理當) 소요시간(所要時間)은 석유(石油)엔진 디젤엔진 공(共)히 8마력(馬力)이 가장 적어 석유(石油)엔진 3.78시간(時間)이었고 디젤엔진은 8.25시간(時間)이었다. (5) 동력경운기(動力耕耘機) 고장부위별(故障部位別) 자가수리시(自家修理時)의 1회수리당(回修理當) 소요시간(所要時間)은 시린더 계통(系統)이 가장 많은 32.02시간(時間)이었고 고장(故障)으로 인(因)하여 가동(稼動)하지 못한 시간(時間)은 시린더 계통(系統)이 가장 많아 년간(年間) 대당(臺當) 37.30시간(時間)이었다.

  • PDF

논벼 장.단간품종의 증발산제계수와 건물량과의 관계에 대한 연구(I) (Studies on Relations between Various Coeffcients of Evapo-Transpiration and Quantities of Dry Matters for Tall-and Short Statured Varieties of Paddy Rice)

  • 류한열;김철기
    • 한국농공학회지
    • /
    • 제16권2호
    • /
    • pp.3361-3394
    • /
    • 1974
  • The purpose of this thesis is to disclose some characteristics of water consumption in relation to the quantities of dry matters through the growing period for two statured varieties of paddy rice which are a tall statured variety and a short one, including the water consumption during seedling period, and to find out the various coefficients of evapotranspiration that are applicable for the water use of an expected yield of the two varieties. PAL-TAL, a tall statured variety, and TONG-lL, a short statured variety were chosen for this investigation. Experiments were performed in two consecutive periods, a seedling period and a paddy field period, In the investigation of seedling period, rectangular galvanized iron evapotranspirometers (91cm${\times}$85cm${\times}$65cm) were set up in a way of two levels (PAL-TAL and TONG-lL varieties) with two replications. A standard fertilization method was applied to all plots. In the experiment of paddy field period, evapotanspiration and evaporation were measured separately. For PAL-TAL variety, the evapotranspiration measurements of 43 plots of rectangular galvanized iron evapotranspirometer (91cm${\times}$85cm${\times}$65cm) and the evaporation measurements of 25 plots of rectangular galvanized iron evaporimeter (91cm${\times}$85cm${\times}$15cm) have been taken for seven years (1966 through 1972), and for TONG-IL variety, the evapotranspiration measurements of 19 plots and the evaporation measurements of 12 plots have been collected for two years (1971 through 1972) with five different fertilization levels. The results obtained from this investigation are summarized as follows: 1. Seedling period 1) The pan evaporation and evapotranspiration during seedling period were proved to have a highly significant correlation to solar radiation, sun shine hours and relative humidity. But they had no significant correlation to average temperature, wind velocity and atmospheric pressure, and were appeared to be negatively correlative to average temperature and wind velocity, and positively correlative to the atmospheric pressure, in a certain period. There was the highest significant correlation between the evapotranspiration and the pan evaporation, beyond all other meteorological factors considered. 2) The evapotranpiration and its coefficient for PAL-TAL variety were 194.5mm and 0.94∼1.21(1.05 in average) respectively, while those for TONG-lL variety were 182.8mm and 0.90∼1.10(0.99 in average) respectively. This indicates that the evapotranspiration for TONG-IL variety was 6.2% less than that for PAL-TAL variety during a seedling period. 3) The evapotranspiration ratio (the ratio of the evapotranspiration to the weight of dry matters) during the seedling period was 599 in average for PAL-TAL variety and 643 for TONG-IL variety. Therefore the ratio for TONG-IL was larger by 44 than that for PAL-TAL variety. 4) The K-values of Blaney and Criddle formula for PAL-TAL variety were 0.78∼1.06 (0.92 in average) and for TONG-lL variety 0.75∼0.97 (0.86 in average). 5) The evapotranspiration coefficient and the K-value of B1aney and Criddle formular for both PAL-TAL and TONG-lL varieties showed a tendency to be increasing, but the evapotranspiration ratio decreasing, with the increase in the weight of dry matters. 2. Paddy field period 1) Correlation between the pan evaporation and the meteorological factors and that between the evapotranspiration and the meteorological factors during paddy field period were almost same as that in case of the seedling period (Ref. to table IV-4 and table IV-5). 2) The plant height, in the same level of the weight of dry matters, for PAL-TAL variety was much larger than that for TONG-IL variety, and also the number of tillers per hill for PAL-TAL variety showed a trend to be larger than that for TONG-IL variety from about 40 days after transplanting. 3) Although there was a tendency that peak of leaf-area-index for TONG-IL variety was a little retarded than that for PAL-TAL variety, it appeared about 60∼80 days after transplanting. The peaks of the evapotranspiration coefficient and the weight of dry matters at each growth stage were overlapped at about the same time and especially in the later stage of growth, the leaf-area-index, the evapotranspiration coefficient and the weight of dry matters for TONG-IL variety showed a tendency to be larger then those for PAL-TAL variety. 4) The evaporation coefficient at each growth stage for TONG-IL and PAL-TALvarieties was decreased and increased with the increase and decrease in the leaf-area-index, and the evaporation coefficient of TONG-IL variety had a little larger value than that of PAL-TAL variety. 5) Meteorological factors (especially pan evaporation) had a considerable influence to the evapotranspiration, the evaporation and the transpiration. Under the same meteorological conditions, the evapotranspiration (ET) showed a increasing logarithmic function of the weight of dry matters (x), while the evaporation (EV) a decreasing logarithmic function of the weight of dry matters; 800kg/10a x 2000kg/10a, ET=al+bl logl0x (bl>0) EV=a2+b2 log10x (a2>0 b2<0) At the base of the weight of total dry matters, the evapotranspiration and the evaporation for TONG-IL variety were larger as much as 0.3∼2.5% and 7.5∼8.3% respectively than those of PAL-TAL variety, while the transpiration for PAL-TAL variety was larger as much as 1.9∼2.4% than that for TONG-IL variety on the contrary. At the base of the weight of rough rices the evapotranspiration and the transpiration for TONG-IL variety were less as much as 3.5% and 8.l∼16.9% respectively than those for PAL-TAL variety and the evaporation for TONG-IL was much larger by 11.6∼14.8% than that for PAL-TAL variety. 6) The evapotranspiration coefficient, the evaporation coefficient and the transpiration coefficient and the transpiration coefficient were affected by the weight of dry matters much more than by the meteorological conditions. The evapotranspiratioa coefficient (ETC) and the evaporation coefficient (EVC) can be related to the weight of dry matters (x) by the following equations: 800kg/10a x 2000kg/10a, ETC=a3+b3 logl0x (b3>0) EVC=a4+b4 log10x (a4>0, b4>0) At the base of the weights of dry matters, 800kg/10a∼2000kg/10a, the evapotranspiration coefficients for TONG-IL variety were 0.968∼1.474 and those for PAL-TAL variety, 0.939∼1.470, the evaporation coefficients for TONG-IL variety were 0.504∼0.331 and those for PAL-TAL variety, 0.469∼0.308, and the transpiration coefficients for TONG-IL variety were 0.464∼1.143 and those for PAL-TAL variety, 0.470∼1.162. 7) The evapotranspiration ratio, the evaporation ratio (the ratio of the evaporation to the weight of dry matters) and the transpiration ratio were highly affected by the meteorological conditions. And under the same meteorological condition, both the evapotranspiration ratio (ETR) and the evaporation ratio (EVR) showed to be a decreasing logarithmic function of the weight of dry matters (x) as follows: 800kg/10a x 2000kg/10a, ETR=a5+b5 logl0x (a5>0, b5<0) EVR=a6+b6 log10x (a6>0 b6<0) In comparison between TONG-IL and PAL-TAL varieties, at the base of the pan evaporation of 343mm and the weight of dry matters of 800∼2000kg/10a, the evapotranspiration ratios for TONG-IL variety were 413∼247, while those for PAL-TAL variety, 404∼250, the evaporation ratios for TONG-IL variety were 197∼38 while those for PAL-TAL variety, 182∼34, and the transpiration ratios for TONG-IL variety were 216∼209 while those for PAL-TAL variety, 222∼216 (Ref. to table IV-23, table IV-25 and table IV-26) 8) The accumulative values of evapotranspiration intensity and transpiration intensity for both PAL-TAL and TONG-IL varieties were almost constant in every climatic year without the affection of the weight of dry matters. Furthermore the evapotranspiration intensity appeared to have more stable at each growth stage. The peaks of the evapotranspiration intensity and transpiration intensity, for both TONG-IL and PAL-TAL varieties, appeared about 60∼70 days after transplanting, and the peak value of the former was 128.8${\pm}$0.7, for TONG-IL variety while that for PAL-TAL variety, 122.8${\pm}$0.3, and the peak value of the latter was 152.2${\pm}$1.0 for TONG-IL variety while that for PAL-TAL variety, 152.7${\pm}$1.9 (Ref.to table IV-27 and table IV-28) 9) The K-value in Blaney & Criddle formula was changed considerably by the meteorological condition (pan evaporation) and related to be a increasing logarithmic function of the weight of dry matters (x) for both PAL-TAL and TONG-L varieties as follows; 800kg/10a x 2000kg/10a, K=a7+b7 logl0x (b7>0) The K-value for TONG-IL variety was a little larger than that for PAL-TAL variety. 10) The peak values of the evapotranspiration coefficient and k-value at each growth stage for both TONG-IL and PAL-TAL varieties showed up about 60∼70 days after transplanting. The peak values of the former at the base of the weights of total dry matters, 800∼2000kg/10a, were 1.14∼1.82 for TONG-IL variety and 1.12∼1.80, for PAL-TAL variety, and at the base of the weights of rough rices, 400∼1000 kg/10a, were 1.11∼1.79 for TONG-IL variety and 1.17∼1.85 for PAL-TAL variety. The peak values of the latter, at the base of the weights of total dry matters, 800∼2000kg/10a, were 0.83∼1.39 for TONG-IL variety and 0.86∼1.36 for PAL-TAL variety and at the base of the weights of rough rices, 400∼1000kg/10a, 0.85∼1.38 for TONG-IL variety and 0.87∼1.40 for PAL-TAL variety (Ref. to table IV-18 and table IV-32) 11) The reasonable and practicable methods that are applicable for calculating the evapotranspiration of paddy rice in our country are to be followed the following priority a) Using the evapotranspiration coefficients based on an expected yield (Ref. to table IV-13 and table IV-18 or Fig. IV-13). b) Making use of the combination method of seasonal evapotranspiration coefficient and evapotranspiration intensity (Ref. to table IV-13 and table IV-27) c) Adopting the combination method of evapotranspiration ratio and evapotranspiration intensity, under the conditions of paddy field having a higher level of expected yield (Ref. to table IV-23 and table IV-27). d) Applying the k-values calculated by Blaney-Criddle formula. only within the limits of the drought year having the pan evaporation of about 450mm during paddy field period as the design year (Ref. to table IV-32 or Fig. IV-22).

  • PDF