• Title/Summary/Keyword: 95%25 distribution

Search Result 247, Processing Time 0.034 seconds

A Statistical Study on the Fatigue Behaviors of Nitro-Carburized SCM415 (침탄질화 처리된 SCM415재의 피로거동에 대한 통계적 연구)

  • Song, Sam-Hong;Lee, Sang-Hoon;Lim, Se-Hyuck
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.14 no.5
    • /
    • pp.128-133
    • /
    • 1997
  • Due to their high strength and good wear resistance, nitro-carburizing materials have been used for many machine components. However, the nitro-carburizing materials are found to have one disadvantage ; that is, their strength and fatigue life show larger scatter than those of non-heated metals. In this paper, therfore, the statistical chracteristics of non-heated and nitro-carburized specimens for SCM415 are investi- gated under two different of stress levels 1.15 .sigma. /sub .omega. / .leq. / .sigma. / sub .alpha. / .leq. / 1.25 .sigma. /sub .omega. /. Seven specimens at each stress level are tested by using rotating bending fatigue tester. The relation between a crack length and fatigue cycles can be arranged for Weibull distribution, and S-N curve using 95% reliability function is obtalined for nitro-carburized specimen.

  • PDF

SPRAY STRUCTURE OF HIGH PRESSURE GASOLINE INJECTOR IN A GASOLINE DIRECT INJECTION ENGINE

  • Lee, Chang Sik;Chon, Mun Soo;Park, Young Cheol
    • International Journal of Automotive Technology
    • /
    • v.2 no.4
    • /
    • pp.165-170
    • /
    • 2001
  • This study is focussed on the investigation of spray characteristics from the high pressure gasoline injector for the application of gasoline direct injection engine. For the analysis of spray structure of high pressure gasoline injector; the laser scattering method with a Nd-Yag laser and the Phase Doppler particle analyzer system were applied to observe the spray development and the measurement of the droplet size and velocity of the spray, respectively. Also spatial velocity distribution of the spray droplet was measured by use of the particle image velocity system. Experimental results show that high pressure gasoline injector shapes the hollow-cone spray, and produce the upward ring shaped vortex on the spray surface region. This upward ring shaped vortex promotes the secondary atomization of fuel droplets and contributes to a uniform distribution of fuel droplets. Most of fuel droplets are distributed under 31$\mu m$ of the mean droplet size (SMD) and the frequency distribution of the droplet size under 25$\mu m$ is over 95% at 7 MPa of injection pressure. According to the experimental results of PIV system, the flow patterns of the droplets velocity distribution in spray region are in good agreement with the spray macroscopic behaviors obtained from the visualization investigation.

  • PDF

THE EVOLUTION OF A SPIRAL GALAXY: THE GALAXY

  • Lee, See-Woo;Park, Byeong-Gon;Kang, Yong-Hee;Ann, Hong-Bae
    • Journal of The Korean Astronomical Society
    • /
    • v.24 no.1
    • /
    • pp.25-53
    • /
    • 1991
  • The evolution of the Galaxy is examined by the halo-disk model, using the time-dependent bimodal IMF and contraints such as cumulative metallicity distribution, differential metallicity distribution and PDMF of main sequence stars. The time scale of the Galactic halo formation is about 3Gyr during which the most of halo stars and metal abundance are formed and ${\sim}95%$ of the initial halo mass falls to the disk. The G-dwarf problem could be explained by the time-dependent bimodal IMF which is suppressed for low mass stars at the early phase (t < 1Gyr) of the disk evolution. However, the importance of this problem is much weakened by the Pagel's differential metallicity distribution which leads to less initial metal enrichment and many long-lived metal-poor stars with Z < $1/3Z_{\odot}$ The observational distribution of abundance ratios of C, N, O elements with respect to [Fe/H] could be reproduced by the halo-disk model, including the contribution of iron product by SNIs of intermediate mass stars. The initial enrichment of elements in the disk could be explained by the halo-disk model, resulting in the slight decrease and then the increase in the slopes of the [N/Fe]- and [C/Fe]-distributions with increasing [Fe/H] in the range of [Fe/H] < -1.

  • PDF

Separation of Hydrogen-Nitrogen Gas Mixture by PTMSP-Silica-PEI Composite Membranes (PTMSP-Silica-PEI 복합막에 의한 수소-질소 혼합기체 분리)

  • Lee Hyun-Kyung;Choi Youn-Jung
    • Membrane Journal
    • /
    • v.14 no.4
    • /
    • pp.304-311
    • /
    • 2004
  • The poly(1-trimethylsilyl-1-propyne) (PTMSP) and silica-filled PTMSP membranes were prepared by casting from a toluene solution on porous polyetherimide (PEI). FT-IR spectrum, GPC and SEM pictures have been taken to characterize the membranes. The particle size of membrane decreases as silica content of the membrane increases from 23 to 60 wt%, and a uniform distribution of the silica is observed. The separation properties of the gas mixture (32 mol% $H_2$/ 68 mol% $N_2$) through the composite membranes were studies as a function of pressure and percentage of silica. Selectivity values of $H_2$/$N_2$ increased as the pressure of permeation cell and silica content of the membrane increased. The real separation factor($\alpha$), head separation factor($\beta$), and tail separation factor((equation omitted)) of PTMSP-PEI composite membrane were 2.28, 1.58, and 1.44 respectively at $\Delta$P 30 psi and $25^{\circ}C$. $\alpha$, $\beta$, and (equation omitted) of PTMSP-Silica-PEI composite membrane for 60 wt% silica were 3.34, 1.95, 1.72 at $\Delta$P 30 psi and $25^{\circ}C$.

Development and Verification of Prediction Model for Road Traffic Noise in the Apartment Complex (아파트단지에서 도로교통소음 예측식 개발 및 검증)

  • Lee, Nae-Hyun;Sun, Woo-Young;Cho, Il-Hyoung
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.28 no.1
    • /
    • pp.67-73
    • /
    • 2006
  • 10 sites in building development areas were selected and the noise level were measured by the apartment floors of apartment complex. With the fitted regression analysis, the distribution ratio($R^2$) and correction coefficient(r) was 25%(0.5) in the NIER('87) and 7.5%(0.274) in the NIER('99), respectively. The measured values of the noise level on the seventh floor of complex did not show a good agreement with the predicted noise level in the NIER('87, '99) formula. However, the developed formula demonstrated that the measured values were reasonably close to the predicted values, indicating the validity and adequacy of the predicted models with the fitted vs residual analysis in the 95% of confidence interval and 95% of predict interval. The results suggested that application of this development model obtained by the results according to the apartment floor can be improved in road traffic noise.

Distribution of the Scatter Ray in Fluoroscopy X-ray Room (투시 검사실 내 공간산란선 분포 측정)

  • Cho, Pyong-Kon
    • The Journal of the Korea Contents Association
    • /
    • v.11 no.10
    • /
    • pp.349-354
    • /
    • 2011
  • The results of the scattery distribution in the fluoroscopy X-ray room were as follows. When the measurement was done at the same height with the table, measured value was 0.78 mGy/min ~ 0.04 mGy/min (95%) within 50 cm and 250 cm. At 50 cm below the table, it was 0.17 mGy/min ~ 0.02mGy/min (86%) and at 50 cm above the table was 1.37 mGy/min ~ 0.05 mGy/min (96%), displaying a decrease. At the same time, the amount of rays were reduced in 50 ~ 60% at the same height with the table than the location 50 cm above the table, 90~95% of reduction rate was observed at 50 cm below the table. For the collimator, comparing to the case when it was completely open, the amount of ray was reduced from 0.78 mGy/min to 0.16 mGy/min at 50cm away and 0.04 mGy/min to 0.01 mGy/min at 250cm away thus approximately 80% on average was reduced when the collimator was reduced to 25%. Comparing with the case when there was a object on the table, the amount of scatter ray was reduced by 96.7% at every location when there is not a object on the table.

Changes in the Occurrence of Rotavirus Gastroenteritis before and after the Introduction of Rotavirus Vaccine among Hospitalized Pediatric Patients and Estimates of Rotavirus Vaccine Effectiveness (로타바이러스 백신 도입 후 소아 입원 환자에서의 로타바이러스 위장관염 발생 변화 및 로타바이러스 백신 효과 추정)

  • Yoon, Jung Min;Han, Tae Hwan;Yoon, So Won;Kim, Yong Joo;Oh, Sung Hee
    • Pediatric Infection and Vaccine
    • /
    • v.25 no.1
    • /
    • pp.26-34
    • /
    • 2018
  • Purpose: This study aimed to investigate the changes in the occurrence of rotavirus gastroenteritis (RGE) after the introduction of rotavirus vaccine and estimate rotavirus vaccine effectiveness in hospitalized children. Methods: We compared the retrospective data of 671 patients with acute gastroenteritis (AGE) admitted to the Department of Pediatrics, Hanyang University Seoul Hospital from January 1, 2014, to December 31, 2015, with retrospective data of 1,243 patients admitted to the same institution with AGE from January 1, 2004, to December 31, 2005. The vaccine effectiveness was estimated using a case-positive control test-negative study. Results: The proportion of RGE in AGE was significantly lower in 2014 to 2015 (9.0%, 48/531) than in 2004 to 2005 (22.7%, 282/1,243) (P<0.001). In particular, there was a significant decrease in the 6- to 11-, 12- to 23-, and 24- to 35-month-old groups (P<0.001), whose rotavirus vaccination rates were higher than the remaining age groups. The monthly distribution of patients with RGE in 2004 to 2005 was higher from November to May, peaked in January, followed by December and February. In 2014 to 2015, the monthly distribution of patients with RGE slightly peaked in January. In 2014 to 2015 study, the complete rotavirus vaccination rate was 66.0% (332/503) and incomplete vaccination rate was 6.2% (31/503). Presumed rotavirus vaccine effectiveness was 83.3% (95% confidence interval [CI], 60.5% to 92.9%) in the complete vaccination group and 27.4% (95% CI, -163.7% to 80.0%) in the incomplete group. Conclusions: The proportion of RGE in AGE has markedly decreased since the introduction of rotavirus vaccines, and improving vaccination coverage will further reduce the burden of RGE in Korea.

Assessment of Dose Distributions According to Low Magnetic Field Effect for Prostate SABR

  • Son, Jaeman;An, Hyun Joon;Choi, Chang Heon;Chie, Eui Kyu;Kim, Jin Ho;Park, Jong Min;Kim, Jung-in
    • Journal of Radiation Protection and Research
    • /
    • v.44 no.1
    • /
    • pp.26-31
    • /
    • 2019
  • Background: Stereotactic ablative radiotherapy (SABR) plans in prostate cancer are compared and analyzed to investigate the low magnetic effect (0.35 T) on the dose distribution, with various dosimetric parameters according to low magnetic field. Materials and Methods: Twenty patients who received a 36.25 Gy in five fractions using the MR-IGRT system (ViewRay) were studied. For planning target volume (PTV), the point mean dose ($D_{mean}$), maximum dose ($D_{max}$), minimum dose ($D_{min}$) and volumes receiving 100% ($V_{100%}$), 95% ($V_{95%}$), and 90% ($V_{90%}$) of the total dose. For organs-at-risk (OARs), the differences compared using $D_{max}$, $V_{50%}$, $V_{80%}$, $V_{90%}$, and $V_{100%}$ of the rectum; $D_{max}$, $V_{50%}$, $V_{30Gy}$, $V_{100%}$ of the bladder; and $V_{30Gy}$ of both left and right femoral heads. For both the outer and inner shells near the skin, $D_{mean}$, $D_{min}$, and $D_{max}$ were compared. Results and Discussion: In PTV analysis, the maximum difference in volumes ($V_{100%}$, $V_{95%}$, and $V_{90%}$) according to low magnetic field was $0.54{\pm}0.63%$ in $V_{100%}$. For OAR, there was no significant difference of dose distribution on account of the low magnetic field. In results of the shells, although there were no noticeable differences in dose distribution, the average difference of dose distribution for the outer shell was $1.28{\pm}1.08Gy$ for $D_{max}$. Conclusion: In the PTV and OARs for prostate cancer, there are no statistically-significant differences between the plan calculated with and without a magnetic field. However, we confirm that the dose distribution significantly increases near the body shell when a magnetic field is applied.

Monitoring of Perfluorinated Compounds (PFCs) in the Seawater of the East and West Coast in Korea (동·서해안지역 해수에서 과불화 화합물의 모니터링)

  • Son, Jun-ho;Chung, Seon-Yong;Kwon, Bum Gun
    • Journal of the Korean GEO-environmental Society
    • /
    • v.18 no.11
    • /
    • pp.5-12
    • /
    • 2017
  • Perfluorinated compounds (PFCs) as environmental pollutants are an important environmental issue. However, little is known on the PFCs monitoring of sea waters around estuaries on the East and West Coasts of Korea. This study shows the monitoring results of PFCs in sea waters in these Coasts. Among 10 PFCs selected in this study, concentrations of perfluorooctanesulfonate (PFOS), perfluorooctanoate (PFOA), perfluorobutane sulfonate (PFBS), and perfluorohexane sulfonate (PFHxS) in the East Coast were 9.6-50.7 ng/L (total mean${\pm}$standard deviation: $26.14{\pm}12.66ng/L$), 13.79-44.58 ng/L ($27.95{\pm}11.41ng/L$), limit of quantification (LOQ)-2.6 ng/L ($0.96{\pm}1.15ng/L$), and 2.95-11.05 ng/L ($4.25{\pm}2.57ng/L$), respectively. In the West Coast, concentrations of PFOS, PFOA, PFBS, and PFHxS were 27.66-51.71 ng/L ($36.27{\pm}7.79ng/L$), 8.97-22.53 ng/L ($14.47{\pm}4.25ng/L$), LOQ-2.27 ng/L ($1.63{\pm}0.93ng/L$), and 3.0-7.66 ng/L ($4.27{\pm}1.49ng/L$), respectly. Other PFCs were below LOQ. The result of this study provides the distribution pattern of PFCs for assessing environmental pollution in two coastal areas of Korea.

Modeling and Application of Chlorine Bulk Decay in Drinking Water Distribution System (배급수계통에서 잔류염소 감소 특성 및 적용연구)

  • Ahn, Jae-Chan;Park, Chang-Min;Koo, Ja-Yong
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.19 no.4
    • /
    • pp.487-496
    • /
    • 2005
  • Chlorine bulk decay tests were carried out by bottle test under controlled conditions in a laboratory. Experiments were performed at different temperatures: $5^{\circ}C$, $15^{\circ}C$, $25^{\circ}C$, and the water temperatures when samples were taken from the effluent just before entering to its distribution system. 38 bulk tests were performed for water of Al (water treatment plant), 4 bulk tests for A2 (large service reservoir), and A3(pumping station). Residual chlorine concentrations in the amber bottles were measured over time till about 100 hours and bulk decay coefficients were evaluated by assuming first-order, parallel first-order, second-order. and $n^{th}-order$ reaction. The $n^{th}-order$ coefficients were obtained using Fourth-order Runge-Kutta Method. A good-fit by the average coefficient of determination ($R^2$) was first-order ($R^2=0.90$) < parallel first-order ($R^2{_{fast}}=0.92$, $R^2{_{slow}}=0.95$) < second-order ($R^2=0.95$) < $n^{th}-order$ ($R^2=0.99$). But if fast reaction of parallel first-order bulk decay were applied to the effluent of large service reservoir with ca. 20 hours of travel time and slow reaction in the water distribution system following the first 20 hours, parallel first-order bulk decay would be best and easy for application of water quality modeling technique.