• 제목/요약/키워드: 9000

검색결과 397건 처리시간 0.026초

타코나이트 광산 공정에서의 실시간 질량측정기기와 실시간 수농도의 환산에 의한 질량농도와의 연관성 (Relationships between a Calculated Mass Concentration and a Measured Concentration of PM2.5 and Respirable Particle Matter Sampling Direct-Reading Instruments in Taconite Mines)

  • 정은교;장재길;송세욱;김정호
    • 한국산업보건학회지
    • /
    • 제24권1호
    • /
    • pp.65-73
    • /
    • 2014
  • Objectives: The purposes of this study are to investigate workers' exposures to respirable particles generated in taconite mines and to compare two metric methods for mass concentrations using direct-reading instruments. Methods: Air monitorings were conducted at six mines where subjects have been exposed primarily to particulate matters in crushing, concentrating, and pelletizing processes. Air samples were collected during 4 hours of the entire work shift for similarly exposure groups(SEGs) of nine jobs(N=37). Following instruments were employed to evaluate the workplace: a nanoparticle aerosol monitor(particle size range; 10-1000 nm, unit: ${\mu}m^2/cc$, Model 9000, TSI Inc.); DustTrak air monitors($PM_{10}$, $PM_{2.5}$, unit: $mg/m^3$, Model 8520, TSI Inc.); a condensation particle counter(size range; 20-1000 nm, unit: #/cc, P-Trak 8525, TSI Inc.); and an optical particle counter(particle number by size range $0.3-25{\mu}m$, unit: #/cc, Aerotrak 9306, TSI Inc.). Results: The highest airborne concentration among SEGs was for furnace operator followed by pelletizing maintenance workers in number of particle and surface area, but not in mass concentrations. The geometric means of $PM_{2.5}$ by the DustTrak and the Ptrak/Aerotrak were $0.04{\mu}m$(GSD 2.52) and $0.07{\mu}m$(GSD 2.60), respectively. Also, the geometric means of RPM by the DustTrak and the Ptrak/Aerotrak were $0.16{\mu}m$(GSD 2.24) and $0.32{\mu}m$(GSD 3.24), respectively. The Pearson correlation coefficient for DustTrak $PM_{2.5}$ and Ptrak/Aerotrak $PM_{2.5}$ was 0.56, and that of DustTrak RPM and Ptrak/Aerotrak RPM was 0.65, indicating a moderate positive association between the two sampling methods. Surface area and number concentration were highly correlated($R^2$ = 0.80), while $PM_{2.5}$ and RPM were also statistically correlated each other($R^2$ = 0.79). Conclusions: The results suggest that it is possible to measure airborne particulates by mass concentrations or particle number concentrations using real-time instruments instead of using the DustTrak Aerosol monitor that monitor mass concentrations only.

맥류미성숙 종자와 초기생육과의 관계 (Growth of Seedling from Immature Kernel Harvested at Different Days after Flowering in Rye, Triticale, Wheat and Oat Cultivars)

  • 황종진;하용웅;연규복
    • 한국작물학회지
    • /
    • 제32권2호
    • /
    • pp.188-195
    • /
    • 1987
  • 입당호밀, 두루호밀, 신기호밀(트리티케일), 그루밀, 메귀리 등 5개 품종에 대하여 미성숙종자의 초기 생육(27일간)을 조사하기 위하여 1985년 10월부터 1987년 2월까지 수원지방에서 행한 시험결과를 요약하면 다음과 같다. 1. 미성숙 종자의 천립중은 성숙기까지 계속 증가를 나타냈는데 (r=0.9000 이상), 입당호밀과 두루호밀은 개화후 35 일 (각각 6월 19일, 6월 24 일), 신기호밀, 그루밀, 메귀리 등은 개화후 30일 (각각 6월 29일, 6월 19일, 7월 9 일)에 천립중이 거의 최대에 달하였다. 2. 미성숙 종자의 발아율은 종자의 천립중 증가와는 상관이 높지 않았으며, 메귀리에서 개화후 5일에 49 %의 발아를 보였고 개화후 10 일부터는 94% 이상을 보였다. 기타 품종들도 어느 일정 시기이후에는 90% 이상의 높은 발아율을 보였다. 3. 미성숙 종자에서 생육한 개체의 초장은 종실의 천립중과 고도의 정의 상관을 보였지만 신기호밀과 메귀리에서 개화후 20 일, 25 일, 30 일 (성숙기)에 수확한 종자의 유식물체간에 그루밀에서는 개화후 25일, 30 일 (성숙기) 간에 차이가 적었다. 4. 미성숙 종자에서 온 유식물체의 생체중과 건물중은 종실의 천립중과 고도의 정의 상관을 보였으나 신기호밀, 그루밀, 메귀리 등에서 개화후 25 일이나 30일에 수확한 종자의 유식물체들 간에 차이가 적었다. 5. 수원지방에서 청예용 종자로서 사용할 경우 입당호밀과 두루호밀은 개화후 35 일 (각각 6월 19일, 6월 24 일 ) 신기호밀, 그루밀, 메귀리 등은 개화후 25 일 (각각 6월 24 일, 6월 14 일, 7월 4 일) 에 수확하여도 청예수량이 크게 감소되지 않을 것으로 보인다.

  • PDF

하악 제3대구치와 하악관과의 위치관계에 대한 파노라마 방사선사진과 cone beam형 전산화단층촬영상의 비교 (Comparison of cone beam computed tomography and conventional panoramic radiography in assessing the topographic relationship between the mandibular canal and impacted third molars)

  • 최형수;김규태;최용석;황의환
    • Imaging Science in Dentistry
    • /
    • 제38권3호
    • /
    • pp.169-176
    • /
    • 2008
  • Purpose : To assess the diagnostic accuracy and value in an imaging technique field through the comparison of cone beam computed tomography and conventional panoramic radiography in assessing the topographic relationship between the mandibular canal and impacted third molars. Materials and Methods : Participants consisted of 100 patients offered the images through cone beam computed tomography and panoramic radiography. PSR-$9000^{TM}$ Dental CT system (Asahi Roentgen Ind. Co., Ltd, Japan) was used as the unit of cone beam computed tomography. CE-II (Asahi Roentgen Ind. Co., Ltd, Japan) and Pro Max (Planmeca Oy, Finland) were used as the unit of panoramic radiography. The images obtained through panoramic radiography were classified into 3 types according to the distance between mandibular canal and root of mandibular third molar. And they were classified into 4 types according to the proximity of radiographic feature. The images obtained through cone beam computed tomography based on the classification above were classified into 4 types according to the location between the mandibular canal and the root and were analyzed. And they were classified into buccal, inferior, lingual, and between roots, according to the location between mandibular canal and root. The data were statistically analyzed and estimated by $X^2$-test. Results : 1. There was no statistical significance according to 3 types (type I, type II, type III) through CBCT. 2. The results of 4 types (type A, type B, type C, type D) through CBCT were as high prevalence of CBCT 1 in type A, CBCT 2 in type B, CBCT 3 in type C, and CBCT1 in type D and those of which showed statistical significance (P value=0.03). 3. The results according to location between mandibular canal and root through CBCT recorded each 49, 25, 17, 9 as buccal, inferior, lingual, between roots. Conclusion : When estimating the mandibular canal and the roots through the panoramic radiography, it could be difficult to drive the views of which this estimation was considerable. Thus it is required to have an accurate diagnostic approaching through CBCT that could estimate the location between mandibular canal and roots.

  • PDF

Terahertz Generation and Detection Using InGaAs/InAlAs Multi Quantum Well

  • 박동우;한임식;노삼규;지영빈;오승재;서진석;전태인;김진수;김종수
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2013년도 제45회 하계 정기학술대회 초록집
    • /
    • pp.205-205
    • /
    • 2013
  • 테라헤르쯔(terahertz: THz)파는 0.1~10 THz 의 범위로 적외선과 방송파 사이에 광대역 주파수 스펙트럼을 차지하고 있으며 직진성, 투과성, 그리고 낮은 에너지 (meV)를 가지고 있어 비 파괴적이고 무해한 장점을 지니고 있다. Ti:sapphire laser와 같은 femto-pulse source 등이 많은 발전이 되어 현재 많은 연구와 발전이 이루어지고 있다. femto-pulse source를 이용한 THz 응용에서는 높은 저항, 큰 전자 이동도, 그리고 아주 짧은 전하수명의 기판을 요구하는데 저온에서 성장한 (low-temperature grown : LT) GaAs는 격자 내에 Gallium 자리에 Arsenic이 치환 하면서 AsGa antisite가 발생하여 전하수명을 짧아지는 것을 응용하여 가장 많이 이용되고 있다. 현재 THz 응용분야에서 보다 작고 가격경쟁력이 있는 광통신을 이용한 THz photomixer등이 활발히 연구 하고 있다. 광섬유 내에서 손실과 분산이 최소값을 가지는 부분이 1.55 ${\mu}m$ 부근이고 In0.53Ga0.47As 기판을 이용하였을 때 여기에 완벽하게 만족하게 된다. 하지만 LT-InGaAs 의 경우 AsGa antisite로 인하여 carrier lifetime은 짧아지지만 높은 n-type 전하밀도를 가지게 된다. 이때 Be을 doping하여 전하밀도를 보상하여 높은 저항을 유지해야 하는데 Be의 활성화를 위해서는 열처리를 필요로 한다. 하지만 열처리를 하면 carrier lifetime이 길어지기 때문에 carrier lifetime과 저항을 적절히 조율해야 한다. 이는 물질자체의 특성이기 때문에 InGaAs는 GaAs보다 낮은 amplitude와 짧은 cut-off frequency를 가진다. 본 연구에서는 보다 높은 저항을 얻기 위하여 molecular beam epitaxy를 이용하여 semi-insulating InP:Fe 기판위에 격자 정합된 InGaAs:Be/InAlAs multi quantum well (MQW)를 온도별 ($250{\sim}400^{\circ}C$), 주기별 (50~150)로 성장을 하였고 이때 InGaAs layer의 Be doping level은 $2{\times}1018\;cm^{-3}$, Ex-situ annealing은 $550^{\circ}C$에서 10분으로 고정 하였다. THz 발생 실험에서는 InGaAs/InAlAs MQW은 4000 pA로 1,000 pA를 가지는 InGaAs epilayer보다 4배 높은 전류 신호를 얻을 수 있었고 모든 샘플이 2 THz에서 cut-off frequency를 가지고 있었다. THz 검출 실험에서는 LT-InGaAs:Be epilayer LT-InGaAs:Be/InAlAs, HT-InGaAs/InAlAs 샘플이 각각 180, 9000, 12000 pA의 전류신호를 가지고 있었고 모든 샘플이 2 THz에서 cut-off frequency를 가지고 있었다. HT-InGaAs/InAlAs MQW를 이용한 검출실험에서는 InGaAs layer가 defect free이지만 LT-InGaAs:Be/ InAlAs MQW 보다 높은 전류 신호를 얻을 수 있었다. 이는 InAlAs layer가 저항만 높이는 것뿐만 아니라 carrier trapping layer로써의 역할도 하는 것으로 사료된다.

  • PDF

한국인의 식이섭취와 암 유발의 관계에 관한 연구 -제 1 보 특히 ${\beta}-Carotene$ 섭취량과 혈청내 수준을 중심으로 - (A Study of Relation Between Dietary Vitamin A Intake and Serum Vitamin A Levels and Cancer Risk in Korea)

  • 이기열;이양자;박영심;윤교희;김병수
    • Journal of Nutrition and Health
    • /
    • 제18권4호
    • /
    • pp.301-311
    • /
    • 1985
  • Even though the anticarcinogenic effect of dietary factors especially beta - carotene has been reported by various investigators, the mechanism of the action of ${\beta}-carotene$ has not yet been identified. We carried out the present study to determine the possibilities of relative cancer risk related to dietary intake of vitamin A ( both ${\beta}-carotene$ and retinol ) and blood levels of vitamin A among Koreans. The subjects were divided into two groups; cancer patients and controls. Blood levels for ${\beta}-carotene$ and retinol were analyzed by alumina column chromatography and colorimetry. Dietary intake was examined by food profile and convenient method for evaluating nutritional status through recalling 10 years of food habits. The results obtained are as follows : 1 ) Calorie, protein, fat, and carbohydrate intakes of cancer patient were lower than those of control. Calorie and carbohydrate intakes showed no significant difference but protein and fat intakes were significantly lower in cancer patients. According to cancer sites, in stomach cancer only fat intake was significantly lower than that of control. In lung and larynx cancer calorie, protein, fat and carbohydrate intakes showed similar trend as in control. 2 ) Vitamin A intake of cancer patient was significantly lower than that of control. It was estimated that 83.6% of total Vitamin A intake were provided by ${\beta}-carotene$ for control and cancer patient respectively. 3 ) The mean intake of dietary ${\beta}-carotene$ in cancer patient was significantly lower than that in control ( $7002\;\mu}g/day$ versus $10326\;{\mu}g/day$ ) According to cancer sites in mean intake of dietary ${\beta}-carotene$ was significantly lower in all but stomach cancer compared with that of control. Lung and larynx cancer showed lowest ${\beta}-carotene$ intake with mean value of $5855{\mu}g/day$ and $5492{\mu}g/day$ respectively. 4 ) The mean intake of dietary retinol in cancer patient was significantly lower than that in control ( $245{\mu}g/day$ versus $338{\mu}g/day$ ), but the difference was not significant. 5 ) The relative risk of all cancers in the first (lowest) to the forth quartile level of ${\beta}-carotene$ consumption such as $0-5999{\mu}g/day$. $6000-8999{\mu}g/day$, $9000-11999{\mu}g/day$/ day and $12000-20000{\mu}g/day$ was 85 : 1.7 : 20 : 1.0. The relative risk of all cancers in the first (lowest) to the forth quartile level of retinol consumption, such as $0-299{\mu}g/day$, $300-599{\mu}g/day$, 600-899${\mu}g/day$, and $900-1200{\mu}g/day$, was 1.14 : 067 : 0.21 : 1.0. 6 ) The various food group consumption of cancer patient were significantly lower than those of control in green leafy vegetables, fruits, sea weeds, milk and cheese and eggs. But the Kimchie consumption in cancer patient was three fold higher than that of control ( $1840\;{\mu}g/day$ versus $562\;{\mu}g/day$ ) and in the stomach cancer, Kimchie consumption was the highest, ( $1890\;{\mu}g/day$) According to cancer sites, the consumption of green leafy vegetables was significantly lower in all but stomach cancer compared to control and other vegetables showed no difference between two. In lung and larynx cancer, green leafy vegetables consumption was lowest ( $6094{\mu}g/day$ $5921{\mu}g/day$) and milk and cheese consumption was also( $5\;{\mu}g/day$ and $11{\mu}g/day$) 7 ) The recovery of ${\beta}-carotene$ from human serum by alumina column chromatography was $94.4{\pm}2.3%$. 8 ) Cancer patients showed significantly lower serum retinol ($56.4{\pm}18.1\:{\mu}g/100ml$ versus $72.2{\pm}21.8\:{\mu}g/100ml$) and ${\beta}-carotene$ ($48.9{\pm}33.8\:{\mu}g/100ml$ versus $72.2{\pm}42.6\:{\mu}g/100ml$) concentrations than in controls. 9 ) But breast cancer patients were not significantly different from controls in their serum retinol and ${\beta}-carotene$ concentrations.

  • PDF

CR 시스템의 종류와 I.P 크기에 따른 정량적 영상특성평가 (Imaging Characteristics of Computed Radiography Systems)

  • 정지영;박혜숙;조효민;이창래;남소라;이영진;김희중
    • 한국의학물리학회지:의학물리
    • /
    • 제19권1호
    • /
    • pp.63-72
    • /
    • 2008
  • 최근 의료영상저장 및 전송 시스템(Picture Archiving and Communication System, PACS)의 발전과 함께 디지털 영상의 발전이 가속화되면서, 특히 기존의 아날로그 시스템을 활용할 수 있는 컴퓨터 X-선 촬영(Computed Radiography, CR)의 활용도가 높아졌다. 본 연구에서는 실제 임상에서 사용되고 있는 Agfa CR system (Agfa CR 2.5; Agfa, Belgium)과 Fuji CR system (FCR 9000C; Full, Japan)을 이용하여 영상의 정량적 평가에 널리 사용되고 있는 변조전달함수(Modulation Transfer Function, MTF), 잡음력 스펙트럼(Noise Power Spectrum, NPS), 양자검출효율(Detective Quantum Efficiency, DQE)를 통해 시스템간의 성능 비교 및 I.P (Imaging Plate) 크기별 픽셀 크기 차이 및 선량의 변화에 의한 화질영향을 정량적으로 평가하였다. X-선 영상 획득실험을 위하여 국제표준인 IEC 61267에서 제공하는 RQA5의 선질(Additional Filter $0.7+21Al[mm],\;71[kV_p])$을 사용하였다. 실험 결과 Agfa CR 시스템의 경우 10% 응답의 MTF는 $8{\times}10$ inch와 $14{\times}17$ inch I.P에서 각각 3.9, 2.8 cycles/mm으로 측정되었으며, Fuji CR 시스템의 경우 각각 3.4, 3.2 cycles/mm로 측정되었다 선량의 변화에 따른 MTF도 측정결과는, 두 시스템 모두 선량변화에 따른 MTF의 차이는 크지 않았으며, MTF 10% 응답 주파수 영역도 거의 같은 것을 확인하였다. 이러한 결과를 통하여 선량은 영상의 해상력 및 MTF에는 큰 영향을 미치지 않는 것을 확인하였다. NPS의 경우 Agfa CR 시스템의 $100{\mu}m$ 픽셀 크기를 갖는 $8{\times}10$ inch I.P와 $150{\mu}m$ 픽셀 크기를 갖는 $14{\times}17$ inch I.P사이에 큰 차이가 없었다. 또한 두 시스템 모두 선량이 증가할수록 NPS가 좋아지는 결과를 나타내었다. 진단가능영역인 1.5 cycles/mm 주파수 영역에서 DQE의 효율 측정결과 Agfa CR 시스템의 $8{\times}10$ inch I.P가 11%로 측정되었으며, $14{\times}17\;inch\;I.P$는 8.8%로 측정되었다. Agfa CR 시스템의 DQE 효율 차이는 고주파수 영역에서 두드러지게 나타났다. Fuji CR 시스템의 경우 I.P 크기별 픽셀 크기는 $100{\mu}m$로 동일하였기 때문에 DQE 효율 측정결과 큰 차이를 보이지 않았다. 또한 두 시스템 모두 선량이 증가할수록 DQE 효율은 감소함을 나타내었다. 화질평가의 복합적인 요소를 담고 있는 DQE 측정은 장치의 성능을 점검하고, 환자의 피폭선량을 개선시키는데 중요한 역할을 한다. 본 연구에서는 Agfa CR 시스템과 Fuji CR 시스템의 픽셀 크기별, 선량별 DQE를 측정함으로써 CR 시스템의 임상적 응용의 최적화를 위한 기초 자료로서 이용될 것으로 판단된다.

  • PDF

치과용 초소형 X-선 튜브의 선량평가 (Dosimetric Evaluation of a Small Intraoral X-ray Tube for Dental Imaging)

  • 지윤서;김연우;이레나
    • 한국의학물리학회지:의학물리
    • /
    • 제26권3호
    • /
    • pp.160-167
    • /
    • 2015
  • 의료용 x선 촬영 장치에 있어서 환자에게 피폭되는 선량이 가장 중요한 관심사 중의 하나이다. 본 연구팀에서는 전 세계 최초로 입안에 삽입이 가능한 초소형 x-선 영상 장치가 개발되었는데 이러한 영상장치를 임상에서 사용하기 위해서는 피폭 선량의 평가가 필수적이다. 따라서 본 연구에서는 신개념 치과용 영상장치의 선량을 평가하기 위하여 1) 돼지 턱뼈 팬텀을 직접 제작하여 영상의 질을 평가 하였고, 2) 실제 임상에서 사용가능한 촬영 조건을 결정하였으며, 3) 결정된 촬영 조건에서의 선량을 평가 하였다. 한국 식약처에서 제시하는 치근단 촬영에 대한 환자 선량 권고량(DRLs) 기준에 근거하여 새 개발 장비의 입사표면선량(ESD)와 면적선량(DAP) 측정 방법을 고안하고 각각의 선량 값을 측정하였다. 관전압이 45~55 kV, 관전류가 300 mA 까지 사용 가능한 xoft 사의 초소형 x선 튜브를 사용하였다. 사용된 검출기는 active area가 $72{\times}72mm$ 이고 픽셀 사이즈는 $48{\mu}m$ 이다. 제작된 돼지턱뼈 팬텀은 1 frame/sec의 조건하에 영상을 획득 하였으며, 촬영 조건 최적화를 위하여 관전류를 $20{\sim}80{\mu}A$로 변화시키면서 50 frame씩 영상을 획득하였다. 또한, 상용화 치과용 영상시스템(모델명: CS 2100, 제조사: Carestream Dental LLC 및 모델명: EXARO, 제조사: HIOSSEN)을 이용하여 돼지턱뼈 팬텀의 비교영상 평가를 시행하였다. CS 2100는 60 kV, 7 mA (노출시간:0.125 s)로 하였으며, EXARO는 60 kV, 2 mA로 설정하였다. 선량 평가는 광자극 형광 선량계를 이용하여 입사표면선량을 측정하였으며, 팬텀은 PMMA 재질의 제작된 원통형 팬텀을 이용하였다. 선량계는 팬텀 표면상의 조사야 내부에 2개 및 소스와의 5 cm 거리상에 1개를 위치하여 측정하였다. 빔 조사 조건은 51, 101, 141, $196{\mu}As$로 설정하였다. 면적선량은 소스와 검출기간의 거리가 5 cm 위치에 배치하여 측정하였으며, 이 때 촬영조건은, 관전류 41, 99, 144, 207, $276{\mu}As$의 조건하에서 측정하였다. 임상에서 적용 가능한 관전압과 관전류는 X-선 세기 8000~9000인 지점에서의 관전류 값인 0.051 mAs 이다. 상용화 장비와 영상비교를 한 결과, 개발 장비의 조사야가 훨씬 작음에도 불구하고 치아 및 치아 주위 조직의 영상이 더 우수함을 확인하였다. 또한, 영상 최적화 조사조건인 $51{\mu}As$에서 입사표면선량(ESD)은 식약처 및 IAEA의 권고치보다 훨씬 낮은 1.369 mGy 이다. 조사야 내부의 선량 분포는 표준편차 5~10% 내외로 균일성이 우수 하였다. 측정된 면적선량(DAP)은 $82.4mGy*cm^2$으로 상용화 장비보다 조사야가 훨씬 작음에도 불구하고 식약처의 권고치보다 낮은 값을 보였다. 이러한 연구를 통해서 새 개발 장비의 영상의 우수성과 기존 장비 대비 방사선량에 대한 저감 효과를 확인 할 수 있었으며 치과 장비 개발에 있어서 X선 특성 연구에 대한 기술과 노하우를 축적할 수 있었다.