• Title/Summary/Keyword: 85% Anodizing

Search Result 4, Processing Time 0.019 seconds

Study on Hardness and Corrosion Resistance of Magnesium by Anodizing and Sealing Treatment With Nano-diamond Powder (양극산화와 나노 다이아몬드 분말 봉공처리에 의한 마그네슘의 경도와 부식에 관한 연구)

  • Kang, Soo Young;Lee, Dae Won
    • Journal of Powder Materials
    • /
    • v.21 no.4
    • /
    • pp.260-265
    • /
    • 2014
  • In this study, in order to increase surface ability of hardness and corrosion of magnesium alloy, anodizing and sealing with nano-diamond powder was conducted. A porous oxide layer on the magnesium alloy was successfully made at $85^{\circ}C$ through anodizing. It was found to be significantly more difficult to make a porous oxide layer in the magnesium alloy compared to an aluminum alloy. The oxide layer made below $73^{\circ}C$ by anodizing had no porous layer. The electrolyte used in this study is DOW 17 solution. The surface morphology of the magnesium oxide layer was investigated by a scanning electron microscope. The pores made by anodizing were sealed by water and aqueous nano-diamond powder respectively. The hardness and corrosion resistance of the magnesium alloy was increased by the anodizing and sealing treatment with nano-diamond powder.

Experimental Study on Performances and Economic Evaluations of the Qualify of the Material for Light Path (광도파로(光導波路)를 위한 재질의 성능과 경제적 평가를 위한 실험적 연구)

  • Pak, Ee-Tong;Lee, Kang-Ju;Park, Hae-Sung
    • Journal of the Korean Solar Energy Society
    • /
    • v.27 no.3
    • /
    • pp.175-179
    • /
    • 2007
  • This experimental demonstration has successfully shown that it is possible to use direct sunlight for the illumination of deeper building zones using the material for light path system(light duct). Three kinds of reflectors which were 95% Silver vaporizing fixed, 85% Anodized and 85% Hot melted applied to evaluate and compare their performances each others. Also, these three kind of reflectors were compared in view point of economics. The most high performance was obtained in 95% Silver vaporizing fixed reflector hater than another reflectors of 85% Anodized reflector and 85% Hot melted reflector even though more high production cost in 95% Silver vaporizing fixed reflector. The rest two reflectors of 85% Anodized and 85% Hot melted $10{sim}15%$ less performance than 95% Silver vaporizing fixed reflector but their production cost were low than the production cost of 95% Silver vaporizing fixed reflector which identified very weak and light yellow color in the light.

Template-Based Carbon Nanotubes Field Emitter

  • Jeong, Soo-Hwan;Lee, Ok-Joo;Hwang, Sun-Kyu;Lee, Kun-Hong
    • Journal of Information Display
    • /
    • v.2 no.3
    • /
    • pp.78-85
    • /
    • 2001
  • The growth of carbon nanotubes(CNTs) in anodic aluminum oxide(AAO) template and their application to a field emitter are described. AAO templates were fabricated by anodizing bulk aluminum and sputtered thin Al film on Nb-coated Si wafers. After Co catalyst had been electrochemically deposited into the bottom of the pores in AAO template, CNTs were grown by pyrolyzing $C_2H_2$. Depending on the reaction conditions, CNTs grew up to or over the top of the pores in AAO template with different structures. The morphology and structure of CNTs were observed with a scanning electron microscope and a transmission electron microscope. The diameter of CNTs strongly depended on the size of the pores in AAO template and the growing conditions. The electron field emission measurement of the samples resulted in the turn-on field of 1.9-2.2 $V/{\mu}m$ and the field enhancement factor of 2450-5200. The observation of high field enhancement factors is explained in terms of low field screening effect.

  • PDF

SURFACE CHARACTERISTICS AND BIOACTIVITY OF ANODICALLY OXIDIZED TITANIUM SURFACES (양극산화에 의한 티타늄 산화막의 표면 특성 및 생체 활성에 관한 연구)

  • Lee, Sang-Han;Cho, In-Ho
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.45 no.1
    • /
    • pp.85-97
    • /
    • 2007
  • Statement of problem: Recently, anodic oxidation of cp-titanium is a popular method for treatment of titanium implant surfaces. It is a relatively easy process, and the thickness, structure, composition, and the microstructure of the oxide layer can be variably modified. Moreover the biological properties of the oxide layer can be controlled. Purpose: In this study, the roughness, microstructure, crystal structure of the variously treated groups (current, voltage, frequency, electrolyte, thermal treatment) were evaluated. And the specimens were soaked in simulated body fluid (SBF) to evaluate the effects of the surface characteristics and the oxide layers on the bioactivity of the specimens which were directly related to bone formation and integration. Materials and methods: Surface treatments consisted of either anodization or anodization followed thermal treatment. Specimens were divided into seven groups, depending on their anodizing treatment conditions: constant current mode (350V for group 2), constant voltage mode (155V for group 3), 60 Hz pulse series (230V for group 4, 300V for group 5), and 1000 Hz pulse series (400V for group 6, 460V for group 7). Non-treated native surfaces were used as controls (group 1). In addition, for the purpose of evaluating the effects of thermal treatment, each group was heat treated by elevating the temperature by $5^{\circ}C$ per minute until $600^{\circ}C$ for 1 hour, and then bench cured. Using scanning electron microscope (SEM), porous oxide layers were observed on treated surfaces. The crystal structures and phases of titania were identified by thin-film x-ray diffractmeter (TF-XRD). Atomic force microscope (AFM) was used for roughness measurement (Sa, Sq). To evaluate bioactivity of modified titanium surfaces, each group was soaked in SBF for 168 hours (1 week), and then changed surface characteristics were analyzed by SEM and TF-XRD. Results: On basis of our findings, we concluded the following results. 1. Most groups showed morphologically porous structures. Except group 2, all groups showed fine to coarse convex structures, and the groups with superior quantity of oxide products showed superior morphology. 2. As a result of combined anodization and thermal treatment, there were no effects on composition of crystalline structure. But, heat treatment influenced the quantity of formation of the oxide products (rutile / anatase). 3. Roughness decreased in the order of groups 7,5,2,3,6,4,1 and there was statistical difference between group 7 and the others (p<0.05), but group 7 did not show any bioactivity within a week. 4. In groups that implanted ions (Ca/P) on the oxide layer through current and voltage control, showed superior morphology, and oxide products, but did not express any bioactivity within a week. 5. In group 3, the oxide layer was uniformly organized with rutile, with almost no titanium peak. And there were abnormally more [101] orientations of rutile crystalline structure, and bonelike apatite formation could be seen around these crystalline structures. Conclusion: As a result of control of various factors in anodization (current, voltage, frequency, electrolytes, thermal treatment), the surface morphology, micro-porosity, the 2nd phase formation, crystalline structure, thickness of the oxide layer could be modified. And even more, the bioactivity of the specimens in vitro could be induced. Thus anodic oxidation can be considered as an excellent surface treatment method that will able to not only control the physical properties but enhance the biological characteristics of the oxide layer. Furthermore, it is recommended in near future animal research to prove these results.