• Title/Summary/Keyword: 8.2MHz

Search Result 1,178, Processing Time 0.029 seconds

A study on the deposition of DLC films by magnetron PECVD (Magnetron PECVD에 의한 DLC 박막의 제작에 관한 연구)

  • Kim, Soung-Young;Lee, Jai-Sung;Park, Jin-Seok
    • Proceedings of the KIEE Conference
    • /
    • 1996.07c
    • /
    • pp.1446-1449
    • /
    • 1996
  • Thin films of diamond-like carbon(DLC) have been deposited using a magnetron plasma-enhanced chemical vapor deposition(PECVD) method with an rf(13.56 MHz) plasma of $C_{3}H_{8}$. From the Langmuir probe I-V characteristics, it can be observed that increasing the magnetic field yields an increase of the temperature($T_e$) and density($N_e$) of electron. At a magnetic field of 82 Gauss, the estimated values of $T_e$ and $N_e$ are approximately $1.5\;{\times}\;10^5$ K(13.5 eV) and $1.3\;{\times}\;10^{11}\;cm^{-3}$, respectively. Such a highly dense plasma can be attributed to the enhanced ionization caused by the cyclotron motion of electrons in the presence of a magnetic field. On the other hand, the negative dc self-bias voltage($-V_{sb}$) decreases with an increasing magnetic field, which is irrespective of gas pressure in the range of $1{\sim}7$ mTorr. This result is well explained by a theoretical model considering the variation of $T_e$. Deposition rates of DLC films increases with a magnetic field. This may be due to the increased mean free path of electrons in the magnetron plasma. Structures of DLC films are examined by using various techniques such as FTIR and Raman spectroscopy. Most of hydrocarbon bonds in DLC films prepared consist of $sp^3$ tetrahedral bonds. Increasing the rf power leads to an enhancement of cross-linking of carbon atoms in DLC films. At approximately 140 W, the maximum film density obtained is about 2.4 $g/cm^3$.

  • PDF

Analysis of Partial Discharge Characteristics in SF6 Gas Insulation (SF6 가스절연에서 부분방전의 특성분석)

  • Kim, Sun-Jae;Wang, Guoming;Park, Seo-Jun;Kil, Gyung-Suk;An, Chang-Hwan
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.29 no.7
    • /
    • pp.429-434
    • /
    • 2016
  • This paper deals with the characteristics of partial discharge (PD) for the purpose of a condition based maintenance (CBM) of gas insulated switchgears (GIS) in power equipment. Four types of electrode systems such as a protrusion on enclosure (POE), a particle on spacer (POS), a free particle (FP) and a Floating were designed and fabricated. PD pulses were measured using UHF sensor with a frequency range of 300 MHz~1.4 GHz and a DAQ with a sampling rate of 250 MS/s. Discharge inception voltage (DIV), discharge extinction voltage (DEV), and phase resolved partial discharge (PRPD) were analyzed depending on electrode systems. The average DIV in the POS was 28.8 kV. It was about 1.7 times higher than that in the FP, which was the lowest value of 17.2 kV. The FP shuffled and jumped at the applied voltage of 23.5 kV. Over 95% of PD pulses in the POE were generated in the negative polarity ($181^{\circ}{\sim}360^{\circ}$) of applied voltage. The results showed the phase (${\Phi}$)-magnitude (dBm) of PD pulses by UHF sensor, a cluster was formed separately depending on electrode systems.

Effects of Therapeutic Ultrasound on Experimental Induced Rectal Sarcoma(CT-26) (실험적으로 유발된 직장종양에 대한 치료적 초음파의 효과)

  • Cheong, Mee-Sun;Oh, Myoung-Hwa;Kim, Gye-Yeop;Kim, Chan-Kyu
    • Journal of Korean Physical Therapy Science
    • /
    • v.11 no.3
    • /
    • pp.5-13
    • /
    • 2004
  • The use of therapeutic ultrasound(US) in humans with malignant neoplasms has been contra-indicated in physical therapy practice. Some studies have shown the results after application of US inhibited of tumor growth but some studies have shown the results facilitated of tumor growth in mouse. The purpose of this study were to determine the effects of US on rectal sarcoma(CT-26) in mouse and to determine the histological change of tumor. Thirty-five female BALB/C mouse, age 6 to 8 weeks received subcutaneous injection of 0.1 105 tumor cells. When tumors grew to 5 mm in diameters, the mouse were randomly assigned to control group(n=7) and high powered continuous US group(n=7) and low powered continuous US group(n=7) and high powered pulsed US group(n=7) and low powered pulsed US group(n=7). The experimental group (four groups) received 10 treatments over a 10-day period of 3 MHz ultrasound. Tumor dimension were measured on days 1(start of treatment), 5(midtreatment), and 10(end of treatment, preexcision and postexcision). Tumors were weighed after excision and the mouse were observated histological change of tumor. All tumors grew larger over time. Mean tumor weights(in grams) and volumes(in cubic millimeters) were 2.063 g and $2729.313\;mm^3$ for the high powered continuous US group 1.881 g and $2428.002\;mm^3$ for the low powered continuous US group 1.730 g and $2381.002\;mm^3$ for the high powered pulsed US 1.673 g and $2289.562\;mm^3$ for the low powered pulsed US group 1.670 g and $2297.333\;mm^3$ for the control group. Ultrasound increased the weight and volume of subcutaneous tumor in mouse. We urge caution in the use of ultrasound in the areas of tumors.

  • PDF

Effect of Deep Breathing Exercise and Ankle Exercise on Blood Flow Velocity in the Femoral Vein (심호흡 운동과 발목관절 운동이 대퇴정맥의 혈류속도에 미치는 영향)

  • Jung, Do-Young;Kim, Young;Kwon, Oh-Yun
    • Physical Therapy Korea
    • /
    • v.9 no.2
    • /
    • pp.107-113
    • /
    • 2002
  • This study was conducted to determine the effects of deep breathing exercise and ankle exercise on blood flow velocity in the femoral vein. Sixteen healthy male students were recruited from Yonsei University, at Wonju. The blood flow velocities in the femoral vein were measured under three different conditions: resting, deep breathing, and ankle exercise. All subjects were given a 5-minute relaxing time in supine position prior to the study. Using a doppler ultrasound with a 8 MHz probe, the peak blood flow velocities were collected in a twenty-second-period at each condition. The subjects took a rest in between trials for the blood flow to return to its resting levels. The result showed a significant difference in peak blood flow velocities under those three conditions (p<.001). The peak blood flow velocity was highest in ankle exercise condition. The peak blood velocity was significantly higher in deep breathing condition compared with the resting condition. As a result, it is revealed that not only the muscular contractions but also the deep breathing exercises induced facilitating effects of venous return. Either of the exercise methods can be recommended to prevent blood stasis in patients with risk of deep vein thrombosis after cardiac or lower extremity surgery.

  • PDF

Preparation and Characterization of BCB Resin-BNT Composite Substrate Materials (BCB Resin-BNT 복합 기판 소재의 제조 및 특성 평가)

  • Kim, Un-Yong;Chun, Myoung-Pyo;Cho, Jung-Ho;Kim, Byung-Ik;Lee, Yong-Hyun;Myoung, Sung-Jae;Han, Ik-Hyun;Shin, Dong-Uk
    • Journal of the Korean Ceramic Society
    • /
    • v.44 no.5 s.300
    • /
    • pp.179-183
    • /
    • 2007
  • BCB $Resin-BaNd_2Ti_4O_{12}$(BNT) composites with BNT contents were prepared by tape casting method and epoxy resin-BNT composites were prepared by using heating press. Their dielectric properties and microstructures were investigated. The dielectric properties such as dielectric constant and dielectric loss at 1 MHz for epoxy resin-BNT composites and BCB resin-BNT composites are improved with an increase of BNT volume fraction. The dielectric constant of the Epoxy-BNT composite increased from 5.9 to 7.8 as the volume fraction of BNT increased from 15 to 25. The dielectric constant of the BCB-BNT composite increased from 9.1 to 15.5 as the volume fraction of BNT increased from 30 to 50. The dielectric behavior of BCB-BNT system can be explained by Lichtenecker's equation. The dielectric constant of epoxy resin-BNT composite is smaller than that of BCB resin-BNT composite. These results are considered to be related with the dispersion of BNT filler in polymer matrix from the result of SEM photograph.

Hardware Approach to Fuzzy Inference―ASIC and RISC―

  • Watanabe, Hiroyuki
    • Proceedings of the Korean Institute of Intelligent Systems Conference
    • /
    • 1993.06a
    • /
    • pp.975-976
    • /
    • 1993
  • This talk presents the overview of the author's research and development activities on fuzzy inference hardware. We involved it with two distinct approaches. The first approach is to use application specific integrated circuits (ASIC) technology. The fuzzy inference method is directly implemented in silicon. The second approach, which is in its preliminary stage, is to use more conventional microprocessor architecture. Here, we use a quantitative technique used by designer of reduced instruction set computer (RISC) to modify an architecture of a microprocessor. In the ASIC approach, we implemented the most widely used fuzzy inference mechanism directly on silicon. The mechanism is beaded on a max-min compositional rule of inference, and Mandami's method of fuzzy implication. The two VLSI fuzzy inference chips are designed, fabricated, and fully tested. Both used a full-custom CMOS technology. The second and more claborate chip was designed at the University of North Carolina(U C) in cooperation with MCNC. Both VLSI chips had muliple datapaths for rule digital fuzzy inference chips had multiple datapaths for rule evaluation, and they executed multiple fuzzy if-then rules in parallel. The AT & T chip is the first digital fuzzy inference chip in the world. It ran with a 20 MHz clock cycle and achieved an approximately 80.000 Fuzzy Logical inferences Per Second (FLIPS). It stored and executed 16 fuzzy if-then rules. Since it was designed as a proof of concept prototype chip, it had minimal amount of peripheral logic for system integration. UNC/MCNC chip consists of 688,131 transistors of which 476,160 are used for RAM memory. It ran with a 10 MHz clock cycle. The chip has a 3-staged pipeline and initiates a computation of new inference every 64 cycle. This chip achieved an approximately 160,000 FLIPS. The new architecture have the following important improvements from the AT & T chip: Programmable rule set memory (RAM). On-chip fuzzification operation by a table lookup method. On-chip defuzzification operation by a centroid method. Reconfigurable architecture for processing two rule formats. RAM/datapath redundancy for higher yield It can store and execute 51 if-then rule of the following format: IF A and B and C and D Then Do E, and Then Do F. With this format, the chip takes four inputs and produces two outputs. By software reconfiguration, it can store and execute 102 if-then rules of the following simpler format using the same datapath: IF A and B Then Do E. With this format the chip takes two inputs and produces one outputs. We have built two VME-bus board systems based on this chip for Oak Ridge National Laboratory (ORNL). The board is now installed in a robot at ORNL. Researchers uses this board for experiment in autonomous robot navigation. The Fuzzy Logic system board places the Fuzzy chip into a VMEbus environment. High level C language functions hide the operational details of the board from the applications programme . The programmer treats rule memories and fuzzification function memories as local structures passed as parameters to the C functions. ASIC fuzzy inference hardware is extremely fast, but they are limited in generality. Many aspects of the design are limited or fixed. We have proposed to designing a are limited or fixed. We have proposed to designing a fuzzy information processor as an application specific processor using a quantitative approach. The quantitative approach was developed by RISC designers. In effect, we are interested in evaluating the effectiveness of a specialized RISC processor for fuzzy information processing. As the first step, we measured the possible speed-up of a fuzzy inference program based on if-then rules by an introduction of specialized instructions, i.e., min and max instructions. The minimum and maximum operations are heavily used in fuzzy logic applications as fuzzy intersection and union. We performed measurements using a MIPS R3000 as a base micropro essor. The initial result is encouraging. We can achieve as high as a 2.5 increase in inference speed if the R3000 had min and max instructions. Also, they are useful for speeding up other fuzzy operations such as bounded product and bounded sum. The embedded processor's main task is to control some device or process. It usually runs a single or a embedded processer to create an embedded processor for fuzzy control is very effective. Table I shows the measured speed of the inference by a MIPS R3000 microprocessor, a fictitious MIPS R3000 microprocessor with min and max instructions, and a UNC/MCNC ASIC fuzzy inference chip. The software that used on microprocessors is a simulator of the ASIC chip. The first row is the computation time in seconds of 6000 inferences using 51 rules where each fuzzy set is represented by an array of 64 elements. The second row is the time required to perform a single inference. The last row is the fuzzy logical inferences per second (FLIPS) measured for ach device. There is a large gap in run time between the ASIC and software approaches even if we resort to a specialized fuzzy microprocessor. As for design time and cost, these two approaches represent two extremes. An ASIC approach is extremely expensive. It is, therefore, an important research topic to design a specialized computing architecture for fuzzy applications that falls between these two extremes both in run time and design time/cost. TABLEI INFERENCE TIME BY 51 RULES {{{{Time }}{{MIPS R3000 }}{{ASIC }}{{Regular }}{{With min/mix }}{{6000 inference 1 inference FLIPS }}{{125s 20.8ms 48 }}{{49s 8.2ms 122 }}{{0.0038s 6.4㎲ 156,250 }} }}

  • PDF

Wide Bandgap 박막 태양전지 제작을 위한 P-type a-$SiO_x$:H layer 최적화에 관한 연구

  • Yun, Gi-Chan;Kim, Yeong-Guk;Park, Seung-Man;Park, Jin-Ju;Lee, Seon-Hwa;An, Si-Hyeon;Lee, Jun-Sin
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2010.02a
    • /
    • pp.153-153
    • /
    • 2010
  • p-i-n 형 비정질 실리콘 박막 태양전지에서 p층은 창물질(window material)로서 전기 전도도가 크고, 빛 흡수가 적어야한다. p층의 두께가 얇으면 p층 전체가 depletion layer가 되고 충분한 diffusion potential을 얻을 수 없어 open-circuit voltage ($V_{oc}$)가 작아진다. 반대로 p층 두께가 두꺼워지면 빛 흡수가 증가하고, 표면 재결합이 문제가 되어 변환효율이 감소한다. 밴드갭이 큰 물질로 창층을 제작하게 되면 보다 짧은 파장의 입사광이 직접 i층을 비추므로 Short-circuit current ($I_{sc}$) 와 fill factor를 증가시킬 수 있다. 하여 본 연구에서는 기존의 창층으로 사용되는 Boron을 doping한 p-type a-Si:H 대신에 $N_2O$를 첨가한 p-type a-$SiO_x$:H의 $N_2O$ flow rate에 따른 밴드갭의 변화에 관한 연구를 수행하였다. p-type a-$SiO_x$:H Layer는 $SiH_4$, $H_2$, $N_2O$, $B_2H_6$ 가스를 혼합하여 증착하게 되는데 $SiH_4$, 가스와 $H_2$ 가스의 혼합비는 1:20, $B_2H_6$ 농도는 0.5%로 고정 하였으며 $N_2O$의 flow rate을 가변하며 증착하였다. $N_2O$의 가변조건은 5에서 50sccm으로 가변하여 증착하며 일반적으로 사용되는 RF-PECVD (13.56MHz)를 이용하였고 증착 온도는 175도, 전극간의 거리는 40mm, 파워와 압력은 30W, 700mTorr로 고정하여 진행하였다. 전기적 특성을 알아보기 위해 eagle 2000 Glass를 사용하였고 구조적 특성은 p-type wafer를 사용하여 각각 대략 200nm의 두께로 증착하였다. 증착 두께는 Ellipsometry를 이용하였으며 전기 전도도는 Agilent사의 4156c를 구조적특성은 FT-IR을 사용하여 측정하였다. Conductivity(${\sigma}_d$)는 $N_2O$가 증가함에 따라 $8.73\;{\times}\;10^{-6}$에서 $5.06\;{\times}\;10^{-7}$으로 감소하였고 optical bandgap ($E_{opt}$)은 1.71eV에서 2.0eV로 증가함을 알 수 있었다. 또한 reflective index(n)의 경우는 4.32에서 3.52로 감소함을 나타내었다. 기존의 p-type a-Si:H에 비해 상당한 $E_{opt}$을 가지므로 빛 흡수에 의한 손실을 줄임으로서 $V_oc$를 향상 시킬 수 있으며 동시에 짧은 파장에서의 입사광이 직접 i층을 비추므로 $I_{sc}$와 FF를 향상 시킬 수 있으리라 예상된다. 다소 낮은 전도도만 개선한다면 고효율의 박막 태양전지를 제작 할 수 있을 것으로 기대된다.

  • PDF

Development of Micro Thermal Image Acquisition System (마이크로 열화상 계측 시스템의 IOT 모듈화 개발)

  • Lee, Jun-Yeob;Oh, Jong-woo;Lee, DongHoon
    • Proceedings of the Korean Society for Agricultural Machinery Conference
    • /
    • 2017.04a
    • /
    • pp.169-169
    • /
    • 2017
  • 스마트 돈사 내의 열환경 분석에 필수적으로 고려되어야 인자는 가축의 복사 에너지 변화로 볼 수 있다. 열환경 제어의 대상이기도 하지만 회귀적으로 열환경 변화의 인자이기도 하다. 이러한 가축의 복사 에너지 분석을 위하여 시설 내에 용이하게 배포가 가능한 열화상 계측 시스템을 개발하였다. 초소형 마이크로 열화상 계측 시스템에 부가적으로 IOT(Internet of Thing) 기반 기술을 이용한 모듈화 개발을 병행하였다. 열화상 계측 센서로 LWIR(Longwave infrared)영역에 해당하는 $8{\mu}m{\sim}4{\mu}m$의 영역에서 $0.05^{\circ}C$의 분해능을 보이는 $Lepton^{TM}$ (500-0690-00, FLIR, Goleta, CA)모델을 사용하였다. SPI(Serial Peripheral Interface) 속도 2 Mhz로 마이크로프로세서(NanoPi NEO Air, FrendlyArm, CA, USA)와 고속 통신을 수행하여 9 Hz의 계측이 가능하다. 열화상 센서와 마이컴으로 구성되는 단위 계측 시스템의 통신 기능 확장을 위하여 다음과 같이 세 단계의 정보 전달 시나리오를 설계하였다. 1) 단독적으로 열화상을 계측 하고 내장된 메모리에 저장하는 형식 2) 인접한 사용자 인터페이스에서 1번 단독 모듈에 접속하여 열화상을 실시간으로 전송하여 화면에 도시하는 형식 3) 2번 사용자 도시모듈과 병행적으로 Local WI-FI 통신을 이용한 모바일 기기에 화면을 도시하는 형식. 이와 같은 계층적이며 모듈화된 계측 시스템을 구성하기 위해서 1번 모듈에 공개 소프트웨어인 Hostapd 2.5(http://w1.fi/hostapd)버전을 설치하였다. 외부 인터넷 환경이 없는 상황에 1번 모듈 단독으로 AP(Access Point) 기능을 제공하여 지근 거리에 있는 2번 모듈과 3번 모바일 기기의 접속을 관리할 수 있다. 2번 모듈의 경우 화면 다수의 1번 모듈에 접속을 교차적으로 수행하는 방식과 2번 모듈 자체가 AP가 되어 1번 모듈의 접속을 허용하는 형태로 구성되어 있다. 계측 시스템의 계측 매트릭스 구성에 따라 선택적으로 결정할 수 있다. 1번 2번 모듈 공통적으로 TCP/IP Listener와 Client 서비스를 병렬적으로 수행할 수 있도록 개발을 하였다. 3번 모바일 기기에서 사용자 인터페이스 구현을 위하여 범용 Android 기반 GUI 프로그램과 Socket 통신을 연동시켰다. 1개의 열화상 Frame의 전송량은 9,600 Byte ($=80{\times}60{\times}2Byte$) 로 WI-FI 통신 전송 시 2회 ~ 6회 정도 내외로 가변적인 통신 수행 횟수를 나타내었다. 센서 계측 시스템과 정보 전송 시스템을 병렬적으로 구성한 모듈화 된 계측시스템의 전 요소에서 센서에서 제공하는 최대 계측 주기인 9 Hz 구현이 일반적으로 가능하였다. 이를 이용한 추후 연구를 통해 가축 객체의 열복사 정보와 돈사 내 열환경 간의 역학성을 연구할 것이다.

  • PDF

Effects of Various Thawing Methods on the Quality Characteristics of Frozen Beef

  • Kim, Young Boong;Jeong, Ji Yun;Ku, Su Kyung;Kim, Eun Mi;Park, Kee Jae;Jang, Aera
    • Food Science of Animal Resources
    • /
    • v.33 no.6
    • /
    • pp.723-729
    • /
    • 2013
  • In this study, the quality characteristics due to the influence of various thawing methods on electro-magnetic and air blast frozen beef were examined. The loin and round of second grade Hanwoo were sliced into 5-7 cm thickness and packed with aerobic packaging. The packaged beef samples, which were frozen by air blast freezing at $-45^{\circ}C$ and electro-magnetic freezing at $-55^{\circ}C$, were thawed by 4 thawing methods with refrigeration ($4{\pm}1^{\circ}C$), room temperature (RT, $25^{\circ}C$), cold water ($15^{\circ}C$), and microwave (2450 MHz). These samples were thawed to the point, which were core temperature reached $0^{\circ}C$. Analyses were carried out to determine drip and cooking loss, water holding capacity (WHC), moisture contents and sensory evaluation. Frozen beef thawed by microwave indicated a lower drip loss (0.66-2.01%) than the other thawing methods (0.80-2.50%). Cooking loss after electro-magnetic freezing indicated 52.0% by microwave thawing for round compared with 41.8% by refrigeration, 50.1% by RT, and 50.8% by cold water. WHC thawing by microwave with electro-magnetic freezing didn't showed any difference depending on the thawing methods, while moisture contents was higher thawing by microwave with electro-magnetic freezing than refrigeration (71.9%), RT (75.0%), and cold water (74.9%) for round. The texture of sensory evaluation for round thawed by microwave result was the highest than refrigeration (4.7 point), RT (6.4 point) and cold water (6.6 point), while sensory evaluation was no significant difference. Therefore, it was shown that microwave thawing is an appropriate way to reduce the deterioration of meat quality due to freezing.

A UHF-band Passive Temperature Sensor Tag Chip Fabricated in $0.18-{\mu}m$ CMOS Process ($0.18-{\mu}m$ CMOS 공정으로 제작된 UHF 대역 수동형 온도 센서 태그 칩)

  • Pham, Duy-Dong;Hwang, Sang-Kyun;Chung, Jin-Yong;Lee, Jong-Wook
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.45 no.10
    • /
    • pp.45-52
    • /
    • 2008
  • We investigated the design of an RF-powered, wireless temperature sensor tag chip using $0.18-{\mu}m$ CMOS technology. The transponder generates its own power supply from small incident RF signal using Schottky diodes in voltage multiplier. Ambient temperature is measured using a new low-power temperature-to-voltage converter, and an 8-bit single-slope ADC converts the measured voltage to digital data. ASK demodulator and digital control are combined to identify unique transponder (ID) sent by base station for multi-transponder applications. The measurement of the temperature sensor tag chip showed a resolution of $0.64^{\circ}C/LSB$ in the range from $20^{\circ}C$ to $100^{\circ}C$, which is suitable for environmental temperature monitoring. The chip size is $1.1{\times}0.34mm^2$, and operates at clock frequency of 100 kHz while consuming $64{\mu}W$ power. The temperature sensor required a -11 dBm RF input power, supported a conversion rate of 12.5 k-samples/sec, and a maximum error of $0.5^{\circ}C$.