• Title/Summary/Keyword: 8.2MHz

Search Result 1,178, Processing Time 0.03 seconds

Quality Evaluation of Pork with Various Freezing and Thawing Methods

  • Ku, Su Kyung;Jeong, Ji Yun;Park, Jong Dae;Jeon, Ki Hong;Kim, Eun Mi;Kim, Young Boong
    • Food Science of Animal Resources
    • /
    • v.34 no.5
    • /
    • pp.597-603
    • /
    • 2014
  • In this study, the physicochemical and sensory quality characteristics due to the influence of various thawing methods on electro-magnetic and air blast frozen pork were examined. The packaged pork samples, which were frozen by air blast freezing at $-45^{\circ}C$ or electro-magnetic freezing at $-55^{\circ}C$, were thawed using 4 different methods: refrigeration ($4{\pm}1^{\circ}C$), room temperature (RT, $25^{\circ}C$), cold water ($15^{\circ}C$), and microwave (2450 MHz). Analyses were carried out to determine the drip and cooking loss, water holding capacity (WHC), moisture content and sensory evaluation. Frozen pork thawed in a microwave indicated relatively less thawing loss (0.63-1.24%) than the other thawing methods (0.68-1.38%). The cooking loss after electro-magnetic freezing indicated 37.4% by microwave thawing, compared with 32.9% by refrigeration, 36.5% by RT, and 37.2% by cold water in ham. The thawing of samples frozen by electro-magnetic freezing showed no significant differences between the methods used, while the moisture content was higher in belly thawed by microwave (62.0%) after electro-magnetic freezing than refrigeration (54.8%), RT (61.3%), and cold water (61.1%). The highest overall acceptability was shown for microwave thawing after electro-magnetic freezing but there were no significant differences compared to that of the other samples.

A Study on the Design of Ku-band Mixer Using a HEMT (HEMT를 이용한 Ku-band 혼합기의 설계에 관한 연구)

  • 성혁제;구자건
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.18 no.7
    • /
    • pp.944-950
    • /
    • 1993
  • Diodes and GaAs have been commonly used in a mixer design until recently. However, diodes are not preferred to use at the front-end of DBS receiver due to the conversion loss large noise. HEMT has larger conversion gain and better noise characteristics comparing with GaAs MESFET. This paper describes the design procedure, structure, and performance of a mixer, utilizaing HEMT designed by OKI Co. . A mixer configuration in which the local oscillator(LO) signal is applied to the gate is used. When the LO power is 0.01 dBm, the conversion gain of 3.7dB is obtained at IF and the 3 dB bandwidth is 400MMz.

  • PDF

Fuzzy Logic PID controller based on FPGA

  • Tipsuwanporn, V.;Runghimmawan, T.;Krongratana, V.;Suesut, T.;Jitnaknan, P.
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2003.10a
    • /
    • pp.1066-1070
    • /
    • 2003
  • Recently technologies have created new principle and theory but the PID control system remains its popularity as the PID controller contains simple structure, including maintenance and parameter adjustment being so simple. Thus, this paper proposes auto tune PID by fuzzy logic controller based on FPGA which to achieve real time and small size circuit board. The digital PID controller design to consist of analog to digital converter which use chip TDA8763AM/3 (10 bit high-speed low power ADC), digital to analog converter which use two chip DAC08 (8 bit digital to analog converters) and fuzzy logic tune digital PID processor embedded on chip FPGA XC2S50-5tq-144. The digital PID processor was designed by fundamental PID equation which architectures including multiplier, adder, subtracter and some other logic gate. The fuzzy logic tune digital PID was designed by look up table (LUT) method which data storage into ROM refer from trial and error process. The digital PID processor verified behavior by the application program ModelSimXE. The result of simulation when input is units step and vary controller gain ($K_p$, $K_i$ and $K_d$) are similarity with theory of PID and maximum execution time is 150 ns/action at frequency are 30 MHz. The fuzzy logic tune digital PID controller based on FPGA was verified by control model of level control system which can control level into model are correctly and rapidly. Finally, this design use small size circuit board and very faster than computer and microcontroller.

  • PDF

A Study on the Parallel Multiplier over $GF(3^m)$ Using AOTP (AOTP를 적용한 $GF(3^m)$ 상의 병렬승산기 설계에 관한 연구)

  • Han, Sung-Il;Hwang, Jong-Hak
    • Journal of IKEEE
    • /
    • v.8 no.2 s.15
    • /
    • pp.172-180
    • /
    • 2004
  • In this paper, a parallel Input/Output modulo multiplier, which is applied to AOTP(All One or Two Polynomials) multiplicative algorithm over $GF(3^m)$, has been proposed using neuron-MOS Down-literal circuit on voltage mode. The three-valued input of the proposed multiplier is modulated by using neuron-MOS Down-literal circuit and the multiplication and Addition gates are implemented by the selecting of the three-valued input signals transformed by the module. The proposed circuits are simulated with the electrical parameter of a standard $0.35{\mu}m$CMOS N-well doubly-poly four-metal technology and a single +3V supply voltage. In the simulation result, the multiplier shows 4 uW power consumption and 3 MHzsampling rate and maintains output voltage level in ${\pm}0.1V$.

  • PDF

Fluctuation in Plasma Nanofabrication

  • Shiratani, Masaharu
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2016.02a
    • /
    • pp.96-96
    • /
    • 2016
  • Nanotechnology mostly employs nano-materials and nano-structures with distinctive properties based on their size, structure, and composition. It is quite difficult to produce nano-materials and nano-structures with identical sizes, structures, and compositions in large quantities, because of spatiotemporal fluctuation of production processes. In other words, fluctuation is the bottleneck in nanotechnology. We propose three strategies to suppress such fluctuations: employing 1) difference between linear and nonlinear phenomena, 2) difference in time constants, and 3) nucleation as a bottleneck phenomenon. We are also developing nano- and micro-scale guided assembly using plasmas as a plasma nanofabrication.1-5) We manipulate nano- and micro-objects using electrostatic, electromagnetic, ion drag, neutral drag, and optical forces. The accuracy of positioning the objects depends on fluctuation of position and energy of an object in plasmas. Here we evaluate such fluctuations and discuss the mechanism behind them. We conducted in-situ evaluation of local plasma potential fluctuation using tracking analysis of fine particles (=objects) in plasmas. Experiments were carried out with a radio frequency low-pressure plasma reactor, where we set two quartz windows at the top and bottom of the reactor. Ar plasmas were generated at 200 Pa by applying 13.56MHz, 450V peak-to-peak voltage. The injected fine particles were monodisperse methyl methacrylate-polymer spheres of $10{\mu}m$ in diameter. Fine particles were injected into the reactor and were suspended around the plasma/sheath boundary near the powered electrode. We observed binary collision of fine particles with a high-speed camera. The frame rate was 1000-10000 fps. Time evolution of their distance from the center of mass was measured by tracking analysis of the two particles. Kinetic energy during the collision was obtained from the result. Potential energy formed between the two particles was deduced by assuming the potential energy plus the kinetic energy is constant. The interaction potential is fluctuated during the collision. Maximum amplitude of the fluctuation is 25eV, and the average is 8eV. The fluctuation can be caused by neutral molecule collisions, ion collisions, and fluctuation of electrostatic force. Among theses possible causes, fluctuation of electrostatic force may be main one, because the fine particle has a large negative charge of -17000e and the corresponding electrostatic force is large compared to other forces.

  • PDF

Study of the Dependency of the Specific Power Absorption Rate on Several Characteristics of the Excitation Magnetic Signal when Irradiating a SPION-containing Ferrofluid

  • Rosales, Alejandra Mina;Aznar, Elena;Coll, Carmen;Mendoza, Ruben A. Garcia;Bojorge, A. Lorena Urbano;Gonzalez, Nazario Felix;Martinez-Manez, Ramon;del Pozo Guerrero, Francisco;Olmedo, Jose Javier Serrano
    • Journal of Magnetics
    • /
    • v.21 no.3
    • /
    • pp.460-467
    • /
    • 2016
  • Magnetic hyperthermia mediated by superparamagnetic particles is mainly based in sinusoidal waveforms as excitation signals. Temperature changes are conventionally explained by rotation of the particles in the surrounding medium. This is a hypothesis quite questionable since habitual experimental setups only produce changes in the magnetic module, not in the field lines trajectories. Theoretical results were tested by changing the waveform of the exciting signal in order to compare non-sinusoidal signals against sinusoidal signals. Experiments were done at different frequencies: 200 KHz, 400 KHz, 600 KHz, 800 KHz and 1 MHz. Superparamagnetic Iron Oxide samples (SPION), made of magnetite ($Fe_3O_4$) and suspended in water (100 mg/ml), were used. Magnetic field strength varies from $0.1{\pm}0.015KA/m$ to $0.6{\pm}0.015KA/m$. In this study was observed that the power loss depends on the applied frequency: for 1 to 2.5 RMS current the responses for each signal are part of the higher section of the exponential function, and for 3.5 to 8 RMS current the response is clearly the decrement exponential function's tale (under $1{\times}10^3LER/gr$).

The Creation of Dental Radiology Multimedia Electronic Textbook (멀티미디어기술을 이용한 치과방사선학 전자 교과서 제작에 관한 연구)

  • Kim Eun-Kyung;Cha Sang-Yun;Han Won-Jeong;Hong Byeong-Hee
    • Imaging Science in Dentistry
    • /
    • v.30 no.1
    • /
    • pp.55-62
    • /
    • 2000
  • Purpose: This study was performed to develop the electronic textbook (CD-rom title) about preclinical practice of oral and maxillofacial radiology, using multimedia technology with interactive environment. Materials and Methods: After comparing the three authoring methods of multimedia, i.e. programming language, multimedia authoring tool and web authoring tool, we determined the web authoring tool as an authoring method of our electronic textbook. Intel Pentium II 350 MHz IBM-compatible personal computer with 128 Megabyte RAM, Umax Powerlook flatbed scanner with transparency unit, Olympus Camedia l400L digital camera, ESS 1686 sound card, Sony 8 mm Handycam, PC Vision 97 pro capture board, Namo web editor 3.0, Photoshop 3.0, ThumbNailer, RealPlayer 7 basic and RealProducer G2 were used for creating the text document, diagram, figure, X-ray image, video and sound files. We made use of javascripts for tree menu structure, moving text bar, link button and spread list menu and image map etc. After creating all files and hyperlinking them, we burned out the CD-rom title with all of the above multimedia data, Netscape communicator and plug in program as a prototype. Results and Conclusions : We developed the dental radiology electronic textbook which has 9 chapters and consists of 155 text documents, 26 figures, 150 X-ray image files, 20 video files, 20 sound files and 50 questions with answers. We expect that this CD-rom title can be used at the intranet and internet environments and continuous updates will be performed easily.

  • PDF

Ultrasound Guided Shoulder Joint Injection through Rotator Cuff Interval (초음파를 활용한 회전근개 간격으로 접근한 견관절 주사법)

  • Lim, Jong Bum;Kim, Young Ki;Kim, Sung Woo;Sung, Kyu Wan;Jung, Il;Lee, Chung
    • The Korean Journal of Pain
    • /
    • v.21 no.1
    • /
    • pp.57-61
    • /
    • 2008
  • Background: Shoulder joint injection is currently performed under fluoroscopic or computed tomography scan guidance. We performed this study to determine if an ultrasound guided shoulder joint injection through rotator cuff interval would have clinical usefulness. Methods: A total of 17 volunteers [12 women, 5 men; mean age 28 yr (23-32 yr)] received shoulder joint injection under multilinear ultrasound (5-10 MHz). Volunteers were positioned supinely on a table with their arm in a neutral position. The anterior shoulder region of the patient was sterilized using povidone iodine. A 24 gauge needle was introduced and directly visualized in real time as it passed obliquely from the skin surface to the inferior space of the biceps tendon. If there was little or no resistance to the injection, a contrast media (omnipaque) was injected and checked fluoroscopically. Results: Ultrasound guided shoulder joint injection through rotator cuff interval was successful in all cases. The average time taken for the procedure was $27.5{\pm}16.5sec$. The vertical distance from skin to the inferior space of the biceps tendon was $1.6{\pm}0.4cm$ and the distance of needle from the skin to the inferior space of biceps tendon was $2.8{\pm}0.6cm$. The procedure was well tolerated by all volunteers. Conclusions: Ultrasound guided shoulder joint injection through rotator cuff interval is an effective, rapid, and easy-to-perform injection technique. Ultrasound guided injection enables exact needle placement and avoids the use of both ionizing radiation and iodinated contrast material.

Cramer-Rao Lower Bound of Effective Carrier-to-noise Power Ratio Estimation for a GPS L1 C/A Signal under Band-limited White Noise Jamming Environments (대역제한 백색잡음 재밍환경에서 GPS L1 C/A 신호를 위한 유효 반송파 대 잡음 전력비 추정치의 CRLB)

  • Yoo, Seungsoo;Yeom, Dong-Jin;Jee, Gyu-In;Kim, Sun Yong
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.20 no.8
    • /
    • pp.890-894
    • /
    • 2014
  • In this paper, we derive the CRLB (Cramer-Rao Lower Bound) of effective carrier-to-noise power ratio ($C/N_0$) estimation for a GPS (Global Positioning System) L1 C/A (Coarse/Acquisition) signal under band-limited white noise jamming environments. The quality of a received GPS signal is commonly described in terms of its $C/N_0$, implying that the noise is white and thus can be described by scalar noise density. However, if some intentional interference is received to a victim GPS receiver, then the $C/N_0$ is no longer the efficacious performance indicator. The correct and straightforward measurement to analyze the receiving situation is the effective $C/N_0$. In this paper, we consider a band-limited white noise jamming whose bandwidth is 2MHz and is the same as one of the first null-to-null bandwidth of the GPS L1 C/A signal.

A Solar Stationary Type IV Radio Burst and Its Radiation Mechanism

  • Liu, Hongyu;Chen, Yao;Cho, Kyungsuk;Feng, Shiwei;Vasanth, Veluchamy;Koval, Artem;Du, Guohui;Wu, Zhao;Li, Chuanyang
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.43 no.1
    • /
    • pp.52.2-53
    • /
    • 2018
  • A stationary Type IV (IVs) radio burst was observed on September 24, 2011. Observations from the Nançay RadioHeliograph (NRH) show that the brightness temperature (TB ) of this burst is extremely high, over 10^11K at 150 MHz and over 10^8K in general. The degree of circular polarization (q ) is between -60%~-100%, which means that it is highly left-handed circularly polarized. The flux-frequency spectrum follows a power-law distribution, and the spectral index is considered to be roughly -3~-4 throughout the IVs. Radio sources of this event are located in the wake of the coronal mass ejection and are spatially dispersed. They line up to present a formation in which lower-frequency sources are higher. Based on these observations, it is suggested that the IVs was generated through electron cyclotron maser emission.

  • PDF