The Usefulness of a Wearable Smart Insole for Gait and Balance Analyses After Surgery for Adult Degenerative Scoliosis: Immediate and Delayed Effects (척추측만증 환자의 수술 효과 평가 수단으로서 웨어러블 스마트 깔창을 이용한 보행분석의 유용성)

  • Seo, Min Seok;Shin, Myung Jun;Kwon, Ae Ran;Park, Tae Sung;Nam, Kyoung Hyup
    • Journal of Convergence for Information Technology
    • /
    • v.10 no.2
    • /
    • pp.184-192
    • /
    • 2020
  • This study presents a gait analysis method (including time series analysis) using a smart insole as an objective and quantitative evaluating method after lumbar scoliosis surgery. The participant is a degenerative lumbar scoliosis patient. She took 3-min-gait-test four times(before and 8, 16, and 204-days after surgery) and 6-min-gait-test once(204-days after surgery) with smart-insoles in her shoes. Each insole has 8-pressure sensors, an accelerometer, and a gyroscope. The measured values were used to compare the characteristics of gait before and after surgery. The analysis showed that all of the patient's gait parameters improved after surgery. And after 6 months, the gait was more stable. However, after long walk, the swing duration of one leg was slightly shorter than that of the other again. It was a preclinical problem that could not be found in the visual examination by the practitioner. With this analysis method we could evaluate the improvement of patient quantitatively and objectively. And we could find a preclinical problem. This analysis method will lead to the studies that define and distinguish gait patterns of certain diseases, helping to determine appropriate treatments.

The Validity of a Combined High Saphenous Division and Sclerotherapy for Varicose Vein (하지정맥류의 치료에 있어서 복재정맥 분리 결찰 및 혈관 경화요법 병용의 유용성)

  • Choi Se-Yong;Yang In-Suk;Won Tae-Hee
    • Journal of Chest Surgery
    • /
    • v.39 no.7 s.264
    • /
    • pp.544-548
    • /
    • 2006
  • Background: The purpose of this study is to evaluate the validity of a combined high saphenous vein division and sclerotherapy without sacrificing saphenous vein for varicose vein. Material and Method: Between August 2004 and October 2005, 70 limbs in 50 patients were treated by a combined high saphenous vein division and sclero-therapy. The operative indication is valvular incompetence of femoral-saphenous or popliteal-saphenous junction. Patients received local anesthesia and were treated by a combined high saphenous vein division, ligation of incompetent perforating vein and $1{\sim}3%$ sclerosant. Patients received 1 day hospitalization and applied in com-pression stocking for 6 weeks. Patients followed after 1 week, 1 and 3 months. Result: Mean age of patients was $50{\pm}11$. The female was more common. 8 patients was no symptom, another 42 patients complained of pain, heaviness and fatigue of limbs. The symptoms of varicose vein disappeared 1 month after the procedure in all symptomatic patients. 8 patients needed a adjuvant sclerotherapy for residual varicose vein on 1 week after the procedure. There were only minor complications such as hematoma (1), wound infection (1), thrombophlebitis (20), skin blister (10), hyper-pigmentation (1), and skin ulcer (1). Conclusion: We concluded that a combined high saphenous vein division and sclerotherapy without sacrificing saphenous vein for varicose vein is simple, less invasive, economical, and effective treatment for primary varicose vein, and it has a special advantage that saphenous vein can be used as a bypass conduit later. The method was selective in old aged patients.

Assessment of Wicking and Fast Dry Properties According to Moisture Transport Measurement Method of Knit and Woven Fabrics for Garment (의류소재용 직·편물의 수분이동 특성 측정 방법에 따른 흡한속건성 평가)

  • Kim, Hyun-ah;Kim, Seung-jin
    • Science of Emotion and Sensibility
    • /
    • v.20 no.2
    • /
    • pp.117-126
    • /
    • 2017
  • In this study, moisture transport characteristics for the woven and knitted fabrics made of 8 kinds of fiber materials using MMT (moisture management tester) were measured and discussed with the Bireck bt MMT and water evaporating rate (WER) measuring methods, which are vertical moisture transport methods. In addition, the drying property by MMT of the eight kinds of specimens was compared and discussed with the results measured by the vertical drying measurement. MMT experimental result which is horizental moisture transport appeared to be similar to the result of the Bireck method, which is the vertical moisture transport experiment. Absortion time measured from drip method of the fabrics made of the bamboo, linen, and cotton/nylon composite fabrics was short and thus they showed best wicking property, which was attributed to the low contact angle on the fabric surface and high porosity of the fabrics due to the staple yarn structure composed of the hydrophilic staple fibers. In drying property of the fabric specimens by MMT, maximum absorption radius of the dry-zone knit and bamboo woven fabrics were the highest and they showed the best drying property, which was a little different result compared with vertical drying measurement method. Half time of the drying rate in the MMT method was highly correlated with the fabric thickness and saturated moisture absortion rate and their regression coefficients were 0.9 and 0.88, respectively. This means that the knitted and woven fabric design technology for retaining good wicking and drying properties of the fabrics with thin fabric thickness is very important for obtaining high functional wear comfort fabrics. In addition, wicking and drying properties of the fabrics made of different fiber materials and with different yarns and fabric structures showed different results according to the measuring methods.

Hazards of Chloroprene and the Workplace Management (클로로프렌의 유해성과 작업환경 관리)

  • Kim, Hyeon-Yeong;Lim, Cheol-Hong
    • Journal of the Korean Institute of Gas
    • /
    • v.19 no.3
    • /
    • pp.1-8
    • /
    • 2015
  • In this study, we performed risk assessment of chloroprene by hazard evaluation and workplace investigation. The chemical is used to manufacture of shoes, tires, adhesives, and classified as IARC category 2B (possibly carcinogenic to humans) and target organ systemic toxicity. It is used about 1,300 tons per year in 27 sites. It was calculated the risk of carcinogenesis with chloroprene by Monte-carlo simulation that the averages are 2,199 and 26,404 in each case of working less than 15 minutes per day with local exhaust ventilation and over 4 hours per day without local exhaust ventilation. The risk of target organ systemic toxicity are 4.10 and 169.06 with high correlation with working time to be longer and with ventilation system. Therefore, it is recommended that the local exhaust ventilation and respirators to prevent occupational cancer and target organ systemic toxicity with chloroprene. Especially it is determined that there is a need to strengthen the workplace exposure limit (TWA 10 ppm) in Korea since it is managed with TWA less than 5 ppm ($18mg/m^3$) by the United States Occupational Safety and Health Administration (OSHA) as well as it has carcinogenicity, reproductive toxicity.

Effect of Golf Shoe Design on Kinematic Variables During Driver Swing (골프화의 구조적 특성 및 내부형태에 따른 스윙의 운동학적 변인에 미치는 영향)

  • Park, Jong-Jin
    • Korean Journal of Applied Biomechanics
    • /
    • v.19 no.1
    • /
    • pp.167-177
    • /
    • 2009
  • The purpose of this study was to investigate effect of golf shoe design on kinematic variables during golf swing. Five professional male golfers with shoe size 270mm were recruited for the study. Swing motion was collected using 8 high speed camera motion analysis at a sampling of 180Hz. Kinematic variables were calculated by EVaRT 4.2 software. Driver swing was divided into four events; El(adress), E2(top), E3(impact) and E4(finish). Time, peak velocity, velocity of center of mass, velocity of the foot and ankle angle during Phase 1(El-E2), Phase 2(E2-E3), and Phase 3(E3-E4) were analyzed in order to investigate the relationship between golf shoe design and swing performance. The findings indicated that type C golf shoes would be beneficial for stability and control of movement during address and swing performance. Furthermore, faster speed of golf shoes, center of mass, and both feet were observed with Type C golf shoes. It is expected that golfers with Type C golf Shoes provide greater force as they control the center of mass faster and increase rotational force during impact compared to other golf shoes.

A Study on the Tannin Weighting of Silk (견의 탄닌가공에 관한 연구)

  • Jeong, In-Mo;Lee, Yong-U;Lee, Gi-Won
    • Journal of Sericultural and Entomological Science
    • /
    • v.28 no.1
    • /
    • pp.72-78
    • /
    • 1986
  • The studies were performed to investigate the optimum conditions for tannic processing of silk by use Chinese Gallotannin and synthesized tannic acid, which are aimed at weighting, dyeing and physical properties of tannin treated silk. 1. It was reasonable that the concentration of tannin solution is 30 grams per liter of Chinese Gallotannin, 15 grams per liter of tannic acid for the efficient weighting of processed silk. The temperature and time for tannin treatment was optimum at 80$^{\circ}C$, 60 minutes and the acidity of tannin solution at pH 2 to 3. 2. In dyeing the tannintreated silk by Acid dye Orange II, the temperature and time was reasonable at 60$^{\circ}C$, 90 minutes to control the desorption of tannin components weighted onto silk. 3. The colour differences ($\Delta$E) of dyed silk fabric by soaping could be remarkably narrowed by tannin treatment, resulting in improving the washing fastness of tannin treated silk by two grades more than that of untreated one. 4. The light fastness of tannin treated silk could be drastically improved by reducing the dye-loss of dyed silk fabric which was coused from the Ultra-violet ray irrdiation. 5. The rubbing fastness and water repellency of tannin treated silk was at the same level with that of untreated one. However, the Drape coefficient of tannin treated silk was decreased more than that of untreated one, which is closely related with fabric softness and dressing appearence.

  • PDF

The Effect of Vestibular Sensory Integration on the Sensory Processing, Problem Behavior, and Auditory Behavior of Children With Cochlear Implants (전정감각 중심의 감각통합치료가 인공와우 수술 아동의 감각처리, 문제행동, 청각행동에 미치는 영향)

  • Park, Ye-Hyun;Kim, Hee
    • The Journal of Korean Academy of Sensory Integration
    • /
    • v.19 no.1
    • /
    • pp.13-23
    • /
    • 2021
  • Objective : This study examined the effects of vestibular sensory integration on the sensory processing, problem behavior, and auditory behavior in children who had cochlear Implants. Methods : This single-subject AB study was conducted for 11 weeks from August to November 2019 with three children with cochlear implants. A pre-test measure of each child's sensory processing and auditory behavior was recorded with the baseline on operationally defined behavioral problems as four incidents during 40 minutes of free play with an occupational therapist. The treatment period was 15 40-minute sessions of vestibular sensory integration. Behavioral problems were monitored and recorded during each treatment session. Once treatment was complete, a post-test was conducted on the children's sensory processing and auditory behavior. Results : The sensory processing and auditory behavior of all three participants improved after the vestibular-focused sensory integration, and diverse problem behaviors showed decreasing trends during the interventions. Conclusion : Vestibular sensory integration leads to positive changes in the sensory processing, problem behavior, and auditory behavior of children with cochlear implants.

Transilluminated Powered Phlebectomy Using Arthroscopic Equipment in Varicose Vein of Lower Extremities (하지정맥류에서 관절경 장비를 이용한 광투시 전동형 정맥적출술)

  • 박형주;이철세;이길노;이석열
    • Journal of Chest Surgery
    • /
    • v.36 no.6
    • /
    • pp.391-396
    • /
    • 2003
  • Background: Recently transilluminated powered phlebectomy was introduced and used as a method of surgical treatment for varicose vein in lower extremities. The advantage of transilluminated powered phlebectomy are minimal scar and good cosmetic effect. However, the disadvantages of transilluminated powered phlebectomy is that a high priced Trivex system must be used which increases the patient's expenses. Therefore, we performed a transilluminated powered phlebectomy using an existing arthroscopic equipment instead of Trivex system and observed the effect of treatment and efficiency of the treatment. Material and Method: From March, 2000 to February, 2003, 78 patients (113 limbs) underwent transilluminated powered phlebectomy with an arthroscopic equipment. Patient's disease history, the number of operative scars and complications were reviewed. Result: The operation was performed in 133 limbs of the 78 patients (34 men, 44 women) and the age of patients were ranged from 16 to 72 years with mean age of 41.8 years. Operative time ranged from 20 to 65 minutes (average 48.7 minutes) per limb. The number of operative scar per limb from 2 to 7 (average 4.9). Postoperative complications are transient ecchymosis (78 cases) that desappeared spontaneously, edema persisting longer than 3 weeks (6 cases), remnant varicose vein (4 cases), skin perforation during operative procedure (2 cases), and contact dermatitis due to compression stocking (4 cases) The mean hospitalization day was 3.09 days. Subjective mean satisfaction degree of operation by the patients using a visual analogue scale was 92.6%. Conclusion: Our findings demonstrated that transilluminated powered phleectomy using arthroscopic equipment was possible and had good cosmetic results with acceptable complications.

Studies on Seeding Mechanized Culture of Wheat in Paddy Field (답리작 소맥의 파종 기계화 재배에 관한 연구)

  • 박문수;장민식;이강세;박노풍
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.24 no.3
    • /
    • pp.35-42
    • /
    • 1979
  • Experiments were conducted to find out the labor saving efficiency and optimum seeding rate and fertilizer level when newly invented Barley Rotor Caster was used in wheat sowing on paddy field. It decreased the labor for sowing by 66~77% compared with conventional sowing method. And the optimum. seeding rate was considered to be approximately 20$\ell$Q per 10a in standard fertilizer level and optimum fertilizer level to be 18-12-12kg/10a, $N-P_2O_5-K_2O$ respectively.

  • PDF

Perfusion RRI of the Brain Using Oxygen Inhalation (산소 호흡을 이용한 뇌의 관류 자기공명영상)

  • 최순섭
    • Investigative Magnetic Resonance Imaging
    • /
    • v.4 no.2
    • /
    • pp.113-119
    • /
    • 2000
  • Purpose : To know the possibility of clinical application of MRI using oxygen inhalation as a perfusion MRI Materials and methods : Two healthy volunteers and three patients of one moyamoya disease, one acute infarction and one meningioma were studied using a 1.5 Tesla MRI unit. Oxygen (15 liters/min) mixed with room air was given using face mask from 8 second to 35 second during the study. Images were acquired 25 times (scan time per study were 1.6 seconds) using susceptibility contrast EPI (echo planar image) sequence. Difference maps were acquired by early (study 12-18), and late (study 19-25) O2 inhalation image groups minus pre-O2 inhalation image group (study 3-9) with a Z-score of 0.7-1.0 using VB31C program of Magneton Vision. The resulting perfusion images were created by superimposition of difference maps on corresponding T1 weighted anatomic images. On moyamoya patient, similar perfusion images were acquired after Gd-DTPA injection, and compared with O2 inhalation perfusion images. Results ; The author can get the perfusion images of the brain by oxygen inhalation with susceptibility contrast EPI sequence at the volunteers, and the patient of moyomoya disease, acute infarction and meningioma. On moyamoya patient, perfusion images with O2 inhalation are similar with perfusion images by Gd-DTPA injection. Conclusion 1 This study has demonstrated that the susceptibility contrast EPI by oxygen inhalation can be used as the clinically useful perfusion MRI technique

  • PDF